Technical specifications Main theatre. Sound

Similar documents
Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Technical Specification

DEREHAM MEMORIAL HALL

Technical Specification for the Alley Theatre, Strabane

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Theatre Technical Specifications

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Technical Specification

New Theatre Royal Lincoln Technical Information

INFORMATION FOR VISITING COMPANIES

Dr JOHN GALLAGHER CONCERT CHAMBER

2017 TECHNICAL SPECIFICATIONS

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Lighthouse Theatre Technical Specification

ISLAND HALL TECHNICAL INFORMATION

The Haymarket Basingstoke Technical Specifications

HIRE AND TECHNICAL INFORMATION

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Technical Information

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Technical Specification

Matt Dann Cultural Centre

Main House Technical Specification

Project manager (PM): Pamela Næss Mail: Phone:

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Project manager (PM): Pamela Næss Mail: Phone:

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

THEATRE EQUIPMENT DECEMBER 2017

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Arlington Arts Tech Spec 2018

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

Technical Specifications Nov 2016

T1 National Theater. Auditorium (Basement 1): 324 Under Balcony (Ground floor): 388 Royal Circle (Level 1): 161 Level 2: 316 Level 3: 422

A red velvet front of house curtain closes off the main stage leaving only the apron visible to the audience.

The Lights Technical Guide June 2017

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

Dr. Fred Speckeen Theatre. Information and Technical Specifications

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

UNIVERSITY CONCERT HALL. Technical Specification

RPAC REDLANDS PERFORMING ARTS CENTRE

Pleasance London Main House Visiting Company Information Pack May 2017

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Technical Director of Production Andrew Quick Ext 252

CHELSEA THEATRE. Technical Specifications

Theatre Technical Specification

Marjorie S. Deane Little Theater

Technical Specification Pavilion Dance

Dugdale Centre Technical Specification

Latrobe Performing Arts Centre

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

Shouson Theatre Venue Specifications (updated Jan 2017)

TECHNICAL RIDER. STAGE 32 m wide x 13 m deep (from setting line / mid point)

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Technical Specification. Updated: April 2016

Facility Information

Source 4 Junior Zoom Profile 575W 14 part of universal rig

Main House Technical Specifications

TECHNICAL SPECIFICATIONS

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Technical Specifications. Taylor Little Theater

Technical Rider. STAGE 32 m wide x 13 m deep (from the prompt)

There are 10 dressing rooms in Theatre Kerkrade.

Technical Specifications

Technical Specifications Updated 01/10/2017. Stage

Technical Information

THE CLASSIC GRAND 18 JAMAICA STREET GLASGOW G1 4QD

Technical Pack. Attenborough Arts Centre

Stage. Get In & Parking

Technical Information

TECHNICAL SPECIFICATION

Compass Theatre - Technical Information Pack

TECHNICAL SPECIFICATIONS

Technical Services and Specification

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Technical Specifications

Technical Specification Ardhowen Theatre

Esso BHP Billiton Wellington Entertainment Centre

Technical Specifications

FOX THEATRE ST. LOUIS

Stephen Roy s. Black & White. On-Site Requirements Stage Setup. Ideal Performance Space Set-up Other Practical Considerations Load In Show Control

THE STREET THEATRE. Technical Specifications

GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16

Hopgood Theatre NOARLUNGA CENTRE

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Technical Data Sheet

TECHNICAL RIDER KOMEDIE

John Leslie Theatre. Technical Specifications. Updated July 2018

Arcadia Performing Arts Center Technical Specifications and Information

Transcription:

Sound Console: Soundcraft Si Performer 3 32 mono mic inputs 4 stereo line inputs 4 stereo Lexicon effects engines Stagebox: Soundcraft Mini Stagebox 32R 32 analogue inputs 8 analogue outputs 4 AES Out Installed in half-height bay with space on top (and power outlets) for accessories such as radio mic receiver and IEM transmitters Loudspeakers FOH: Martin Audio AQ10 Subs: Martin Audio Blackline S18 Monitors: Proel TFLV10P and Mackie DLM12 Amplifiers QSC PLX2402 (FOH, Subs, Monitors) Behringer NX3000 (Monitors) Microphones Shure SM58 vocal mics Shure SM57 instrument mics Shure PGA drum kit Shure wireless hand-held microphone and receiver Numerous microphone stands DI Boxes Three dbx Di1 active Two dbx DJDI dual passive Control position Control room at rear with elevated position behind audience Part of back row auditorium seating can be removed for touring consoles ASL wired intercom system Fixed outlets located in control rooms (LX and sound) plus SM position (stage left) Temporary outlets can be provided on request. Cat5 runs Several Cat5 circuits joining stage areas to LX and SX control rooms Mains supply Numerous 13A sockets available side of stage, SL and SR 32A three phase socket available SL, 3m above stage level Distro to three single phase 32A outlets available Two 15m single phase 32A extensions 32A single phase to 6 x 13A stage box 32A single phase socket also available in control room at rear of auditorium Other items Extra microphones, outboard equipment and various other items may be available on request and subject to availability. There may be an additional hire charge for visiting/touring companies. Re-rigging, substitutions or alterations to the configuration of the standard in-house system are subject to prior arrangement.

Projection Projector 1 XGA resolution (1024 x 768 pixels) 4:3 aspect ratio. VGA input from DSL position. HDMI input from control room. Permanently focussed onto a motorised drop down screen, which is located roughly 2m from the front edge of the stage. Well suited for presentations that include textual content. Projector 2 Sanyo PLC-XT35 (5000 ANSI lumens). XGA resolution (1024 x 768 pixels) 4:3 aspect ratio. DVI-D input from control room, with HDMI and VGA adapters available. Remote signal sender can be moved from the control room down to back row of the auditorium for when shows are operated from there. Focussed onto the white cyc at the rear of the stage. Approximately 6.5m wide image. Due to the nature of the cyc material, this projector is not ideal for intricate textual content.

Lighting Desk: Zero 88 Solution XL 96 channel faders 30 submaster faders (x 20 pages) 4 DMX universes via 5-pin XLR ports (2 universes distributed to stage) Art-Net support via Ethernet port Dimming: Zero 88 Chilli inductive dimmers x 6 (roughly 60 operable channels) 15A outlets distributed throughout the stage and FOH areas DMX outlets: DMX infrastructure (9 x 5-pin XLR outlets) distributed throughout stage area (two universes) House lights: Controlled by separate dimmers, not linkable to the main LX desk Note: House lights have a fixed 2 second dim up and 7 second dim down time, not suitable for quick audience participation uses. Up/down/preset controls located at LX, sound and SM (stage left) positions LX control position: Control room at rear with elevated position behind audience Part of back row auditorium seating can be removed for touring consoles Haze: Unique 2.1 hazer with DMX control Cirro Micro oil cracker with DMX control Mirrorballs: Two 50cm diameter half mirrorballs located over downstage area with DMX rotation control. Can be illuminated using GLP Impression X4 wash lights. Intelligent fixtures: GLP Impression X4 LED wash lights x 12 Robe MMX Spot moving profiles x 6 Conventional fixtures: (FOH front cover) Selecon Arena 2kW fresnels x 6 Teatro 2kW profiles x 2 Selecon Pacific 650W profiles (18-24) degrees x 4 Strand T84 1kW profiles x 8 (Over stage) Strand Patt 743 1kW fresnels x 8 Par cans 1kW (CP62) x 12 QuartzColor Polaris 1kW fresnels x 8 Selecon 3 way LUI cyc lights x 4 (Additional fixtures) Selecon 1200W tungsten follow spots x 2 Strand Coda asymmetric 500W floods x 5 Strand Patt 813 650W profiles x 6 Strand Patt 823 650W profiles x 5 400W UV cannons x 2 2kW DMX controlled strobe x 1 (See the plan on next page for the standard fixture layout) A fairly wide range of Lee Filters gels (saturated colours and correction filters) are kept in stock.

1.2m 1.85m 1.8m 1.0m 0.7m Technical specifications LX Layout Our intention is to retain the lighting rig in this configuration most of the time. However, at certain times the layout (colours and/or fixture positions) may be very different to that shown here. 2m dropper post 1.5m 0.8m 2-153 2-191 37 38 36 40 40 36 38 39 241 (Juliette balcony level) 35 5 x x x 56 x x x x x x 56 x x x 101 121 141 49 28 2-77 2 43 44 45 42 31 41 221 41 32 42 29 3 Mid tabs Tab track 496 261 LX3 281 Half mirrorball Half mirrorball 8 7 6 5 4 3 2 1 301 51 2-1 1 161 43 46 47 48 52 44 53 45 13m 45 46 47 48 59 44 43 60 2-39 6 181 43 44 45 321 LX9 61 2-115 54 4 LX1 LX8 LX7 LX2 35 (Juliette balcony level) 2m dropper post LX5 SN Par Patt 743 LN Par Selecon Arena (2kW) Patt 813 (650W) Patt 823 (650W) QuartzColor Polaris Sel Pac (600W) 39 DMX channel 106 Gel number T84 Teatro (2kW) [2] [10] [6] [5] [4] [8] [2] [8] [6] [9] GLP Impression X4 [12] Robe MMX Spot [6] Grey area = grid level walkways = valances and legs 12 Maximum trim height is approximately 6m 25 7 9 13 24 9 7 15 16 17 18 19 20 21 22 6 5 5 6 Auditorium Important: Diagram is not to scale and all dimensions are approximate

Scale plan view showing all bars LX9 LX8 Cyc LX7 Blacks Mid blacks Tab track LX5 Blues LX3 8 7 6 5 4 3 2 1 LX1 LX2 Browns ORCHESTRA PIT Scale 10mm = 1m

Cyc Technical specifications Scale plan view showing usable central performance area Blacks Useable central stage area (9.85m wide x 9.5m deep) MSR Leg MSL Leg ORCHESTRA PIT Scale 10mm = 1m

Scale side view showing bars, drapes and projector locations CYC US Blacks LX9 LX8 LX7 Mid blacks Tab rail LX6 LX5 LX4 Projector 1 screen Blues LX3 LX2 Projector 2 LX1 Browns FOH bridge Projector 1 T84s Audience seating ORCHESTRA PIT Scale 10mm = 1m

Audience & Stage Auditorium 312 numbered seats (see seating plan below). Rear row seats can be removed in pairs to accommodate disabled guests, technical & video recording equipment, as required. Fixed raked seating (rising up from stage level). Stage area Performance area on stage is approximately 10m x 9m. No flying facilities. Proscenium opening approximately 12m wide (bordered by soft legs and a valance). Orchestra Pit 10.5m x 2.5, can accommodate 10 musicians + MD. Fully separated crossover / back passage behind stage. Venue access Scene dock doors approximately 1.8m wide and 7.6m high Double stage doors at rear, with loading area to accommodate two large vans or three cars. Free parking at rear of theatre for production crew / cast, this is shared as an overflow car park for audience members. Tabs and bars Motorised main tabs (aka blues ) with variable speed - track across upstage of the orchestra pit. Controls located at LX, sound and SM (stage left) positions Additional wide tabs (aka browns ) with manual winder handle - encompass the full downstage perimeter of the orchestra pit. Winder located on SL Juliette balcony. Mid-stage black tabs with manual pull cord (near to SM position, stage left) Various other bars available for hanging static or swipe cloths, although please note there is no fly tower - cloths cannot be taken up. Upstage perimeter has a white cyc plus black tabs that can be drawn across. One extendable tri-truss on two 250kg motorised winches, can be moved to numerous positions from DS to US with sufficient notice. Most bars have a total 150kg SWL. Mains supply Numerous 13A sockets available side of stage, SL and SR. Distributed 16A and 13A sockets available throughout the overstage rig. 32A three phase socket available SL, 3m above stage level. Distro to 3 x 1P 32A available plus 2 x 15m 1P 32A extensions and 32A 1P to 6 x 13A stage box. 32A single phase socket also available in control room at rear of auditorium.