J/POE-CF-01 User s Guide

Similar documents
User s Guide F-SM-MM-02 Stand-Alone Media Converter Fast Ethernet or ATM Singlemode to Multimode

User s Guide TN-J48xxx HP Compatible Small Form Factor Pluggables (SFPs) Transceiver Module

User s Guide J/GE-CF-01(SX) Stand-Alone Media Converter Gigabit Ethernet Copper to Fiber 1000Base-T to 1000Base-SX/LX

USER S GUIDE F-SM-MM-06 Stand-Alone Media Converter OC-12 ATM / SONET Singlemode to Multimode

User s Guide J/RS232-xx-01 Stand-Alone Media Converter Just Convert-It RS-232 to Fiber

User s Guide SSETF10xx-205 Stand-Alone Media Converter Ethernet and Fast Ethernet 10/100Base-TX to 10/100Base-SX

SPOEB10xx-100 User s Guide

USER S GUIDE SRS4Fxxxx-10x Stand-Alone Media Converter RS485/422 Copper to Fiber

USER S GUIDE SRS4Fxxxx-10x Stand-Alone Media Converter RS485/422 Copper to Fiber

User s Guide CSETF10xx-205 Slide-in-Module Media Converter Ethernet and Fast Ethernet 10/100Base-TX to 10/100Base-SX

USER S GUIDE CRS4Fxxxx-10x Slide-in-Module Media Converter RS485/422 Copper to Fiber

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

User s Guide SGETF10xx-10x Stand-Alone Media Converter Gigabit Ethernet Copper to Fiber 1000Base-T to 1000Base-SX/LX

Port 2 - Duplex Fiber-Optic. 10/100/1000-Base-TX SGFEB

User s Guide CRS2F31xx-100 Slide-in-Module Media Converter RS-232 to Fiber

User s Guide SGETF10xx-1xx Stand-Alone Media Converter Gigabit Ethernet Copper to Fiber 1000Base-T to 1000Base-SX/LX

User s Guide TN-GB-SM512. Gigabit Interface Converter (GBIC) Transceiver Modules

User s Guide CETTF * Slide-in-Module Media Converter Ethernet Copper to Fiber 10Base-T to 10Base-FL

User s Guide M/E-ISW-FX-01(xxx) Series Stand-Alone Industrial Media Converters Copper to Fiber 10/100Base-TX to 100Base-FX

User s Guide SRS2F Stand-Alone Media Converter RS-232 to Fiber

Standard Temperature Models: media converters that can be used in a standard temperature environment from 0 C to 50 C (32 F to 122 F)

USER S GUIDE NEC-FXE-xx-01, 100Base-FX Express Card

User s Guide E-100BTX-FX-05(XLW) Stand-Alone Media Converter Fast Ethernet Copper to Fiber 100Base-TX to 100Base-FX Extended Temperature

User s Guide SBFTF10xx-10x Stand Alone Media Converter Copper to Fiber 10/100 Bridging (2 Ports) 10/100Base-TX to 100Base-FX

SVIDF201x-100. SVIDF201x-110

USER S GUIDE N-FXE-xxx-02, 100Base-FX Fiber Adaptor NIC Cards

E-100BTX-FX-05 IN THE NETWORK

User s Guide SPSVT26xx-10x Stand Alone Device High-Speed Serial V.35/X.21/RS449/RS530/RS232 Copper to Fiber

M/E ISW FX 01 Series. User Guide. Contents. Introduction

User Guide SBFTF10xx-1xx Stand-Alone Media Converters

T1/E1 Twisted-Pair Copper to Fiber Media Converters USER S GUIDE COMPLIANCE INFORMATION. SSDTF10xx*-100

ST, 850 nm multimode 2 km (1.2 miles)* SSDTF RJ-45. ST, 1310 nm single mode 8 km (4.8 miles)* SSDTF RJ km (5,000 feet) *

33415 Rev. B Page 1 of 22

User s Guide C3110: Gigabit Ethernet Copper & Fiber Ports 1000Base-T to 1000Base-SX/LX Connectivity

USER S GUIDE NEC-GXE-xx Base-X Fiber ExpressCard

User s Guide CGETF10xx-1xx Slide-in-Module Media Converter Gigabit Ethernet Copper to Fiber 1000Base-T to 1000Base-SX/LX

Part Number Port One - Copper Port Two - Duplex Fiber-Optic CSDTF ST, 850 nm multimode 2 km (1.2 miles)* CSDTF RJ-45 RJ-45

M/E ISW FX 02 Series. Industrial Stand Alone Media Converters User Guide. Table of Contents

Compliance Information

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

User s Guide CMEFG10xx-1xx - Slide-in-Module SMEFG10xx-1xx - Stand-Alone Media Converters

M/GE-ISW-xx-01 User Guide. Contents. Introduction. Hardened Mini Gigabit Stand-Alone Media Converters

CAPTF33xx-1xx POTS to Fiber Optic Slide-In Card (SIC) User s Guide

Perle Fast Ethernet Media Converters

Perle Fast Ethernet Media Converters

Access Converter/ 3. Operation Manual. International Headquarters. European Headquarters. B&B Electronics. 707 Dayton Road Ottawa, IL USA

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

2-Port Hub Type 1 2-Port Hub Type 3 Unshielded 2-Port Hub Type 3 Shielded

User Guide CPSVT26xx-10x Slide-in-Module Device

FIBER OPTIC A/B SWITCH (Non-latching)

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual

Synchronous Fiber Optic Modem

RGBS Video Splitters MARCH 1994 AC063A AC063AE AC064A AC064AE AC065A AC065AE AC066A AC066AE

HD-One DX/DX500 HDMI Extender

43-MILLIMETER COMPATIBLE SWIPE READER TECHNICAL REFERENCE MANUAL

E3/DS3 Fibre Extender

CrystalView DVI Micro-DL Extender

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

IMC-21A Series. Industrial 10/100BaseT(X) to 100BaseFX media converters. Introduction. Specifications. Ethernet Media Converters and Extenders

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

MONOPRICE. BitPath AV HDMI Extender over Single Cat6 Cable, 120m. User's Manual P/N 16228

100-MILLIMETER COMPATIBLE SWIPE READER TECHNICAL REFERENCE MANUAL

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

RS-232 Line Booster SERIAL CABLE BOOSTER CHASSIS GROUND TX DATA RX DATA RTS CTS DSR SIGNAL GROUND

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

MONOPRICE. BitPath AV VGA Extender over Single Cat6 Cable, 120m. User's Manual P/N 16226

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

AW900mT. User s Manual. Point-to-multipoint. Industrial-grade, ultra-long-range 900 MHz non-line-of-sight wireless Ethernet systems

Ethernet Media Converters

USB-0100TX USB Fast Ethernet Converter. User s Guide

MONOPRICE. BitPath AV SDI Extender over Single Cat6 Cable, 120m. User's Manual P/N 16227

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Owner s Manual. 10/100 Media Converters. Models: N SC-MM (850nm), N SC-15 (1310nm) 10/100/1000 Media Converters

TOURNAMENT NOISE CANCELLING MICROPHONE*

Power Injector 1520 Series

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

twister Mbps Multimode-to-Singlemode Media Converter

OptEnet OC48 Regenerator Module User Manual

twister Mbps TX-to-FX Media Converter

MONOPRICE. Blackbird 4K HDMI Extender. User's Manual P/N 24281

Sync Genlock JULY 1993 AC083A. Sync Genlock

User Guide. TN-QSFP-40G-xx Cisco Compatible 40G QSFP+ Contents. Introduction

MODEL UV232-16X UTP VGA/RS PORT SENDER. UMA1135, Rev 2 CUSTOMER SUPPORT INFORMATION

MONOPRICE. Blackbird 4K HDBaseT Extender Kit. User's Manual P/N 21792

DA1931CT/ TP to Video + Audio Receiver

MONOPRICE. BitPath AV 4K 1X4 HDMI Splitter Extender over Single Cat6 with IR, 120m. User's Manual P/N 16286

4 x 4 VGA Matrix Switch

Copyright Black Box Corporation. All rights reserved.

Long Range Ethernet Extender

MultiView T4 / T5 Transmitter

ODW-621. RS-232 Point-to-point applications

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

Single mode 9/125µm, duplex

HTE Owner s Manual. HDMI, RS-232, IR & Ethernet Extender over HDBaseT with 3D, 4K, POE Support

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

TP /351 HDMI Over Coax with IR

User Guide. HDMI Fiber Optic Extender. DVI-7350a

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

Transcription:

J/POE-CF-0 User s Guide Stand-Alone Converter Power Over Ethernet (POE) 0/00Base-TX to 00Base-FX The J/POE-CF-0 Power over Ethernet (POE) is a two port 0/00Base-TX to 00Base-FX media converter capable of providing power to Data Terminal Equipment (DTE) Power s (PD) via the Dependent Interface (MDI) twisted pair cable. The J/POE-CF-0 emulates Power Sourcing Equipment (PSE) and provides power via the 0/00Base-TX interface for a remote PD device that complies with the IEEE80.af standard. Part Number Port One - Copper 0/00Base-TX J/POE-CF-0 RJ-45 00 m (8 ft.)* J/POE-CF-0 (SC) RJ-45 00 m (8 ft.)* J/POE-CF-0 (SM) RJ-45 00 m (8 ft.)* Port Two - Duplex Fiber-Optic 00Base-FX ST, 00 nm multimode km (. miles) SC, 00 nm multimode km (. miles) SC, 0 nm single mode 0 km (.4 miles) *Cable distances are the typical maximum cable distance. Actual distance is dependent upon the physical characteristics of the network installation. Optional Accessories (sold separately) Part Number Description WMBL Wall Mount Brackets Length: 4.0 in. (0 mm), Fits converter length: 4.7 in. (9 mm) WMBD WMBV DIN Rail Mount Bracket; Length: 5.0 in. (7 mm) Vertical Wall Mount Plate; Length: 5.0 in. (7 mm) Installation.............. Operation............... Cable Specifications.......7 Technical Specifications....8 Troubleshooting..........9 Contact Us............. Compliance Information...

J/POE-CF-0 Installation CAUTION: All installation and service must be performed by qualified service personnel. Read and follow all warning notices and instructions marked on the product or included in the manual. Product features AutoCross (always enabled) The AutoCross feature allows either straight-through (MDI) or crossover (MDI- X) cables to be used when connecting to 00Base-TX devices, such as wireless access point, VoIP phone, network camera, etc. AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up, regardless of the cable configuration devices. Automatic Link Restoration (always enabled) Transition Networks's converters will automatically re-establish link in all network conditions: Without a device reset, the converters will automatically re-establish the link when connected to switches after a link loss. With Auto-Negotiation enabled, automatic link restoration allows using Auto- Negotiation with Link Loss Notification. With Link Pass-Through enabled in both directions, automatic link restoration allows using Link Loss Notification in both directions. Auto-Negotiation (always enabled) The Auto-Negotiation feature allows the media converter to bring up the copper links to the highest speed and mode possible for all the attached network devices. Installation -- continued Product features -- continued Far-End Fault (always enabled) A troubleshooting feature generally used in conjunction with Link Pass Through to notify both end devices of a link loss. If the fiber RX signal is lost on the far end converter, the converter will automatically generate a far-end fault signal and send it on its TX fiber port to notify the near end converter of the fiber link loss. Link Pass Through will then disable the copper links on both ends, alerting both end devices of network trouble. See diagram below. Both end devices are notified automatically of the link loss Prevents loss of valuable data transmitted unknowingly over invalid link Allows quick diagnosis and resolution of network problem Transition Networks media converters that include the FEF feature will work with other network devices that support Far End Fault per IEEE standards. Near-End media converter A disables the copper link original fault on the fiber link Converter A 4 Far-End Fault signal is sent Link Pass-Through (always enabled) Converter B Far-End media converter B disables the copper link The Link Pass-Through allows the media converter to monitor both the fiber and copper RX (receive) ports for loss of signal. In the event of a loss of an RX signal on one media port, the media converter will automatically disable the TX (transmit) signal of the other media port, thus, passing through the link loss. The far-end device is automatically notified of the link loss, which prevents the loss of valuable data unknowingly transmitted over an invalid link. See diagram below. media converter A disables t he fiber TX link media converter B loses the fiber RX link Near-E nd original fault on the copper link Converter A Converter B 4 Fa r-e nd media converter B disa bles the copper link 4-hour Technical Support: -800-0- -- International: 00--95-94-700 techsupport@transition.com -- Click the Transition Now link for a live Web chat.

J/POE-CF-0 Installation -- continued CAUTION: Associated Ethernet wiring shall be limited to inside the building. Install the fiber cable. Locate or build 00Base-FX fiber cable with male, two-stranded TX to RX connectors installed at both ends. See Figure below.. Connect the fiber cables to the SFEPE0xx-xx media converter as described: Connect the male TX cable connector to the female TX port. Connect the male RX cable connector to the female RX port.. Connect the fiber cables to the other device (another media converter, hub, etc.) as described: Connect the male TX cable connector to the female RX port. Connect the male RX cable connector to the female TX port. Installation -- continued Connecting power. Connect the barrel connector, on the external power adapter, to the power port on the converter (on the back of the converter).. Connect the power adapter plug to AC power.. Verify that the converter is powered by observing the illuminated LED power indicator LED on the front panel Barrel-Connector Power Receptacle Chassis Rear Connect fiber cable to media converter as shown. Connect fiber cable to other device (media converter, hub, etc.) as shown RX TX RX TX Install the copper cable. Locate or build 00Base-TX copper cables with male, RJ-45 connectors installed at both ends. See Figure below.. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the media converter.. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on the other device (wireless access point, VoIP phone, network camera, etc.). RJ-45 port on the media converter RJ-45 port on the other device (switch, work station, etc.) 4 4-hour Technical Support: -800-0- -- International: 00--95-94-700 techsupport@transition.com -- Click the Transition Now link for a live Web chat. 5

J/POE-CF-0 Operation Status LEDs The J/POE-CF-0 media converter front panel is shown below. PWR LACT DPX TX RX LACT SPD DPX POE ON ERR 00Bas e-f X 0/00Bas e-tx LED Description PWR Green: Power ON Fiber LACT Green: ON = Link, Blinking = activity Fiber DPX Green: ON = Full, OFF = Half, Blinking = collision TP* LACT Green: ON = Link, Blinking = activity Cable Specifications The physical characteristics must meet or exceed IEEE 80. specifications. Copper cable Category 5: (Minimum Requirement) Gauge 4 to AWG Attenuation.0 db /00m @ 00 MHz Straight-through OR crossover twisted-pair cable may be used. Shielded twisted-pair (STP) OR unshielded Twisted-pair (UTP) may be used. Pins & and & are the two active pairs in an Ethernet network. RJ-45 Pin-out: Pin = TD+, Pin = TD-, Pin = RD+, Pin = RD- Use only dedicated wire pairs for the active pins: (e.g., blue/white & white/blue, orange/white & white/orange, etc.) Do not use flat or silver satin wire. Straight-Through Cable Twisted Pair # Twisted Pair # Twisted Pair # Twisted Pair # Crossover Cable TP SPD TP DPX TP ON (PSE) TP ERR (PSE) Green: ON = 00Mb/s, OFF = 0Mb/s Green: ON = Full, OFF = Half, Blinking = collision Green: ON = Enabled, OFF = Disable Yellow: OFF = no problems detected Faults: Yellow: ON solid = main power is over or under voltage Blink: times per sec - no signature detected Blink: times per sec - overload while applying power Blink: times per sec - short circuit detected Blink: 4 times per sec - multiple problems detected * TP means twisted pair Fiber cable Bit Error Rate: <0-9 Single mode fiber (recommended): 9 µm Multimode fiber (recommended):.5/5 µm Multimode fiber (optional): 00/40, 85/40, 50/5 µm J/POE-CF-0 00 nm multimode Fiber-optic Transmitter Power: min: -9.0 dbm max: -4.0 dbm Fiber-optic Receiver Sensitivity: min: -0.0 dbm max: -4.0 dbm Link Budget:.0 db J/POE-CF-0 (SC) 00 nm multimode Fiber-optic Transmitter Power: min: -9.0 dbm max: -4.0 dbm Fiber-optic Receiver Sensitivity: min: -0.0 dbm max: -4.0 dbm Link Budget:.0 db J/POE-CF-0 (SM) 0 nm single mode Fiber-optic Transmitter Power: min: -5.0 dbm max: -8.0 dbm Fiber-optic Receiver Sensitivity: min: -.0 dbm max: -8.0 dbm Link Budget:.0 db The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-85/CDRH standards and comply with CFR040.0 and CFR040.. 4-hour Technical Support: -800-0- -- International: 00--95-94-700 techsupport@transition.com -- Click the Transition Now link for a live Web chat. 7

J/POE-CF-0 Technical Specifications For use with Transition Networks Model J/POE-CF-0or equivalent Standards IEEE 80., IEEE 80.af Data Rate 0/00 Mb/s Packet Size (Max) 5 bytes Mac Address K Dimensions.5" x x 4.8" (8 mm x 5.4mm x 0mm) Weight 0.8 lbs. ( g) approximately Power Consumption 0 watts (maximum) Power Supply 48VDC, 0.7A external wall-mount adapter Output Voltage 0.5A @ 48VDC,.8W Environment Tmra*: 0 to 40 C ( to 04 F ) Storage Temp: -5 to 85 C (- to 85 F ) Humidity: 5 to 95%, non-condensing Altitude: 0 to 0,000 feet MTBF 49,98 MIL7F Hours,44 Bellcore Hours Warranty Lifetime *Manufacturer s rated ambient temperature. Note: The information in this user s guide is subject to change. For the most up-to-date information on the J/POE-CF-0 media converter, view the user s guide on-line at: www.transition.com. Product is certified by the manufacturer to comply with DHHS Rule /CFR, Subchapter J applicable at the date of manufacture. WARNING: Visible and invisible laser radiation when open. Do not stare into the beam or view the beam directly with optical instruments. Failure to observe this warning could result in an eye injury or blindness. WARNING: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure. WARNING: If the media converter is an IEEE80.-005 Powered (PD) capable of receiving power via the Dependent Interface (MDI) leads, the power source, connector, and cabling attached to the barrel power connector must meet the isolation requirement specified in IEEE80.-005. Failure to observe this warning could result in an electrical shock. Technical Specifications -- continued IMPORTANT Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS, RS4, RS485, DS, DS, Video Coax, etc., are intended to be connected to intra-building (inside plant) link segments that are not subject to lightening transients or power faults. Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS, RS4, RS485, DS, DS, Video Coax, etc., are T to be connected to inter-building (outside plant) link segments that are subject to lightening transients or power faults. Failure to observe this caution could result in damage to equipment. MTBF is estimated using the predictability method. This method is based on MIL- 7F at 5 C ambient temperature, typical enclosure heat rise of 0 C, and nominal operating conditions and parameters. Installation and configuration specific MTBF estimates are available upon request. Contact Technical Support. Troubleshooting If the media converter fails, isolate and correct the fault by determining the answers to the following questions and then take the indicated action:. Is the media converter power LED ON? : Is the barrel connector fully inserted into the media converter? Is the adapter plugged into an AC outlet; if not, plug it into the outlet. Is the AC outlet active; if not, check the outlet s circuit beaker? Contact Technical Support:.800.4.45, then press "." Proceed to step.. Is the POE LED ON? Is there an active (connected to anther device ) RJ-45 cable inserted into the media converter's TX port; if not, insert the cable accordingly. Is the power turned ON to the other device? Contact Technical Support:.800.4.45, then press "." Go to step. 8 4-hour Technical Support: -800-0- -- International: 00--95-94-700 techsupport@transition.com -- Click the Transition Now link for a live Web chat. 9

J/POE-CF-0 Troubleshooting -- continued. Is the TX LACT LED ON Check the twisted pair cables for proper installation in the device at both ends. Disconnect and reconnect the twisted pair cable to restart the initialization process. Restart the attached device to restart the initialization process.. Contact Tech Support: -800-0-. Go to step 4. 4. Is the FL LINK LED ON? Check the fiber cables for proper connection. Verify that the TX and RX cables on the media converter are connected to the RX and TX ports, respectively, on the other device. Disconnect and reconnect the fiber cable to restart the initialization process. Restart the attached device to restart the initialization process. Contact Tech Support: -800-0-. Proceed to step 5. 5. Is data being passed through the device? Ensure the Powered (PD) IEEE 80.af compliant. Ensure the load to the Powered (PD) is less than 0.4 amps. Is a data source connected; if not, connect a data source to the media converter. Is the data source active; if not, start sending data source. Are the FX and TX LACT LEDs flashing? Contact Technical Support:.800.4.45, then press "." Contact Technical Support:.800.4.45, then press "." Contact Us Technical support Technical support is available 4 hours a day. U.S.A. and Canada: -800-0- International: 00--95-94-700 Transition now Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link. Web-Based seminars Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link. E-Mail Ask a question anytime by sending an e-mail to our technical support staff. techsupport@transition.com Address Transition Networks 475 City West Parkway Minneapolis, MN 5544, U.S.A. telephone: 95-94-700 toll free: 800-5-97 fax: 95-94- Declaration of Conformity Name of Mfg: Transition Networks 475 City West Parkway, Minneapolis MN 5544 U.S.A. Model: J/POE-CF-0 Series Converters Part Number(s): J/POE-CF-0, J/POE-CF-0(SC), J/POE-CF-0(SM) Regulation: EMC Directive 89//EEC Purpose: To declare that the J/POE-CF-0 to which this declaration refers is in conformity with the following standards. CISPR:99; EN550:994+A:995+A:997 Class A; FCC Part 5 Subpart B; UL950; CFR Subpart J I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s). Stephen Anderson, Vice-President of Engineering April 7, 00 Date 0 4-hour Technical Support: -800-0- -- International: 00--95-94-700 techsupport@transition.com -- Click the Transition Now link for a live Web chat.

Compliance Information CISPR/EN550 Class A CE Mark FCC regulations This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 5 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense. Canadian regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. European regulations Warning This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für Gegenmaßnahmen verantwortlich. Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées. In accordance with European Union Directive 00/9/EC of the European Parliament and of the Council of 7 January 00, Transition Networks will accept post usage returns of this product for proper disposal. The contact information for this activity can be found in the 'Contact Us' portion of this document. CAUTION: RJ connectors are T INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network. Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG- Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 9//EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität. Trademark notice All registered trademarks and trademarks are the property of their respective owners. Copyright restrictions 004 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic, or mechanical - without written permission from Transition Networks. Printed in the U.S.A. 4.A