Hamamatsu R1584 PMT Modifications

Similar documents
LUDLUM MODEL 43-5 ALPHA SCINTILLATOR. March 2011

The hybrid photon detectors for the LHCb-RICH counters

arxiv: v1 [physics.ins-det] 1 Nov 2015

Mounting a Scintillation Detector

NewScope-7A Operating Manual

LUDLUM MODEL ALPHA-BETA SAMPLE COUNTER SERIAL NUMBER PR AND SUCCEEDING SERIAL NUMBERS. February 2016

GS1881, GS4881, GS4981 Monolithic Video Sync Separators

The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications

Connection Guide of the MOTOTRBO radio to the radioserver as a control station

Calibration of photomultiplier tubes for the large-angle beamstrahlung detector at CESR

Operating Instructions for PMT Tube P3

4.9 BEAM BLANKING AND PULSING OPTIONS

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

Front End Electronics

Development of an Abort Gap Monitor for High-Energy Proton Rings *

CX1725W Liquid Cooled, Hollow Anode Two-Gap Metal/Ceramic Thyratron

Section 5.0: Lab Equipment and Setup

The field cage for a large TPC prototype

Laboratory 11. Required Components: Objectives. Introduction. Digital Displays and Logic (modified from lab text by Alciatore)

Review of the CMS muon detector system

DATASHEET EL1883. Features. Applications. Ordering Information. Demo Board. Pinout. Sync Separator with Horizontal Output. FN7010 Rev 2.

These are used for producing a narrow and sharply focus beam of electrons.

E2V Technologies CX2668A, CX2668AX Air-Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

Requirements for the Beam Abort Magnet and Dump

PoS(PhotoDet 2012)018

First evaluation of the prototype 19-modules camera for the Large Size Telescope of the CTA

3 EXPERIMENTAL INVESTIGATIONS Caroline Robson. 3.1 Aims and Objectives. 3.2 Experimental Method Set Up of the Test Stand

PbSe photoconductive detectors

Laboratory 10. Required Components: Objectives. Introduction. Digital Circuits - Logic and Latching (modified from lab text by Alciatore)

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

FIRST SIMULTANEOUS TOP-UP OPERATION OF THREE DIFFERENT RINGS IN KEK INJECTOR LINAC

Christmas LED Snowflake Project

A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters TWEPP 2016, Karlsruhe HADES CBM

A fast and precise COME & KISS* QDC and TDC for diamond detectors and further applications

MCT photoconductive detectors

arxiv:hep-ex/ v1 27 Nov 2003

Connection Guide of the MOTOTRBO radio to the radioserver as a control station

Laboratory 9 Digital Circuits: Flip Flops, One-Shot, Shift Register, Ripple Counter

Driver circuit for MPPC

Large photocathode 20-inch PMT testing methods for the JUNO experiment

Technology White Paper Plasma Displays. NEC Technologies Visual Systems Division

Peak emission wavelength: 4.3 μm

HAPD and Electronics Updates

Signal processing circuit for 2-D PSD

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

InAsSb photovoltaic detector

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

InAsSb photovoltaic detector

Drift Tubes as Muon Detectors for ILC

RSH27 Nixie Tube Socket with LED


V6118 EM MICROELECTRONIC - MARIN SA. 2, 4 and 8 Mutiplex LCD Driver

PMT Gain & Resolution Measurements in High Magnetic Fields

GEKCO SUBCARRIER REFERENCE OSCILLATOR MODEL SRO10 OPERATION/SERVICE MANUAL

Tube Cricket Build Guide

Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

Tuning eye, or indicator, tubes

Signal processing circuit for 1-D PSD

INTEGRATED CIRCUITS DATA SHEET. TDA4510 PAL decoder. Product specification File under Integrated Circuits, IC02

Liquid Xenon Scintillation Detector with UV-SiPM Readout for MEG Upgrade

PKK PKK CHARACTERISTICS. Dimensions. Travel. Travel speed. Acceleration. Temperature. Special versions APPLICATION AREAS. PLE max.

Lab 7: Soldering - Traffic Light Controller ReadMeFirst

Digital Circuits I and II Nov. 17, 1999

Low output Magnetic types R1 or R7 High output Magnetic types R2 Crystal types R13

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Status of the CUORE Electronics and the LHCb RICH Upgrade photodetector chain

The Cornell/Purdue TPC

Peak emission wavelength: 3.9 μm

Design of a Gaussian Filter for the J-PARC E-14 Collaboration

SPE analysis of high efficiency PMTs for the DEAP-3600 dark matter detector

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Front End Electronics

Modify the UL40-S2 into a Super-Triode amplifier. Ir. Menno van der Veen

Compact size (16 mm diameter, 12 mm seated length), Fast Time response (rise time 0.78 ns)

DSO138mini Troubleshooting Guide

EXPERIMENT #6 DIGITAL BASICS

LA7837, Vertical Deflection Circuit with TV/CRT Display Drive. Package Dimensions

VGA display tester check those computer displays

3B SCIENTIFIC PHYSICS

Applications. Photosensitive area size. Storage temperature Tstg (mm) (mm 2 ) (V) ( C) ( C) S

Laboratory 8. Digital Circuits - Counter and LED Display

110LP MOON Series. Phono Preamplifier. Owner s Manual

Electrical connection

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

Signal processing circuit for 2-D PSD

li, o p a f th ed lv o v ti, N sca reb g s In tio, F, Z stitu e tests o e O v o d a eters sin u i P r th e d est sezio tefa ectro lity stem l su

TPC R&D at Cornell and Purdue

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

Tip: Faller Mittelstadt Apartments with Controlled LED Lighting Date: , Addition

INSTRUMENT CATHODE-RAY TUBE

Hall-B Beamline Commissioning Plan for CLAS12

Performance of the MCP-PMT for the Belle II TOP counter

Physics 323. Experiment # 10 - Digital Circuits

EL302 DIGITAL INTEGRATED CIRCUITS LAB #3 CMOS EDGE TRIGGERED D FLIP-FLOP. Due İLKER KALYONCU, 10043

Lab 7: Soldering - Traffic Light Controller ReadMeFirst

High sensitive photodiodes

A new Scintillating Fibre Tracker for LHCb experiment

INSTRUMENT CATHODE-RAY TUBE

Near infrared image sensor (0.9 to 1.7 µm) with high-speed data rate

Transcription:

Hamamatsu R1584 PMT Modifications Wenliang Li, Garth Huber, Keith Wolbaum University of Regina, Regina, SK, S4S-0A2 Canada October 31, 2013 Abstract Four Hamamatsu H6528 Photomultiplier Tube (PMT) assemblies were purchased by the University of Regina, to be used on the SHMS Heavy Gas Čerenkov detector. Despite the excellent gain, the H6528 signal output has two disturbing characteristics: discharges and ringing tails. In this report, we offer solutions to overcome these issues. 1 Introduction Four 5 Hamamatsu 1 H6528 Photomultiplier Tube (PMT) assemblies were purchased by the University of Regina in May, 2011. These detectors are used on the Heavy Gas Čherenkov detector, which is part of the ongoing Hall C 12 GeV upgrade program at Jefferson Lab. The H6528 PMT assembly consists of three parts: a R1584 PMT, a magnetic shield (µ-metal shield) and an electronic base, shown in Fig 1. Note that the µ-metal shield is coated with electrical insulation paint; the housing of the electronic base is made of aluminum. The maximum operating and recommended voltages are 3000 V and 2000 V according to the specification. The detector li479@uregina.ca huberg@uregina.ca 1 HAMAMATSU Photonics K.K. [IR] 325-6, Sunayama-cho, Naka-ku, Hamamatsu City, Shizuoka Pref., 430-8587, Japan. Website: www.hamamatsu.com 1

Figure 1: Hamamatsu H6528 PMT assembly schematic diagram [1]. gains were measured at the University of Regina, the results were higher than those from the factory test sheet [2]. Despite the high quality gains, the Hamamatsu PMT assemblies as received from the factory have some disturbing characteristics: all four detectors show frequent discharge pulses, see Fig 2(a); sizeable ringing tails are attached to primary pulse, see Fig 2(b). Regarding each of these characteristics, we developed customized methodology to overcome these issues. Hopefully, the solutions presented in this report will be useful to the manufacturer as well as other physicists who may be experiencing similar difficulties. 2

(a) Discharge Signal (b) Ringing Tails Figure 2: Oscilloscope screen shot of the H6528 PMT signal at 2000 V as received from the factory. (a) is an example of a discharge pulse, note that the vertical scale is 500 mv and time scale is 200 ns per division; (b) is an example of a normal pulse with ringing tails, note that the vertical scale is 50 mv and time scale is 10 ns per division. 2 Discharge Pulses After the H6528 was operated for 5-10 mins at a voltage higher than 1500 V, discharge pulses began to appear at a rate of few Hertz (Hz) as observed on an oscilloscope. The discharge rate seems to be proportional to the operating voltage; the initial discharge rate at 2000 V is around 10 Hz, and gradually increases over time. Fig. 2(a) shows an example of a discharge pulse. The height of the discharge pulse could vary from 200 mv to 10 V, and be a few µs wide. Fig. 3 shows a H6528 as received from the manufacturer. Two locations were identified which have contributed the discharge pulses: 1. 1st location is shown as the #1 circle in Fig. 3. Shield discharges to the base. 2. 2nd location is shown as the #2 circle in Fig. 3. Photo-cathode discharges to the shield. From the our study, location #1 contributes around 75% of the discharge pulses. 3

Figure 3: H6528 PMT assembly as received from the manufacturer. Circles represent the identified discharge locations. 2.1 Discharge from Shield to Base The basic design of the H6528 assembly consists of the PMT, the µ-metal shield and the electronic base. The PMT tube slides into the metal shield from the larger opening of the shield; the aluminum shielded base is installed from the smaller opening of the shield. The pins at the end of the PMT need to be inserted into the socket on the base, which hold together the entire assembly. Note that a plastic retaining ring near the end of the smaller opening of the shield prevents light leak as well as centers the PMT inside the shield, as shown in Fig.1. In order to ensure the PMT pins are installed straightly into the socket, the base is designed to be inserted into the µ-shield and pressed against the retaining ring, thus creating by 1 cm overlap between the base aluminum housing and µ-metal shield. From the factory design, only one layer of electrical tape at the end of the base provides the electrical insulation between the base and µ-mental shield, see Fig. 1 and 4. Our study shows that this level of insulation is not sufficient 4

Figure 4: H6528 base as received from the manufacturer. Note that one layer of electrical tape is at the end of the aluminum housing as white arrow indicates. to prevent electric discharge from the shield to the aluminum housing of the base. To completely insulate the shield from the base, the socket end of the aluminum housing of the base was trimmed off and replaced by a 1 wide plastic ring, as shown in Fig. 5 (right). Fig. 5 shows a modified H6528 base (right) and a R1584 base (left), which was purchased in 1991 by the University of Virginia. The photo was taken after all H6528 bases were modified. To our surprise, both bases both have a 1 wide plastic ring to insulate the base from the shield. Obviously, Hamamatsu changed the 1991 base to the current design, thus causing discharges due to poor insulation. We would suggest the manufacturer to investigate and reconsider the available options to eliminate this discharge source at the production level. 2.2 Discharge from Photo-Cathode to Shield The location of this discharge source is shown as the #2 circle in Fig. 3. The discovery of this discharge issue was a surprise, since the µ-metal shields are coated with insulating paint. Additional insulation on the inner surface of the shield is required to completely eliminate the discharge. 5

Figure 5: Left: original R1584 PMT base was purchased by University of Virginia in 1991. Right: H6528 (current R1584) PMT base after modification; 1 wide insulation ring is covered with 2 layers of kaptom tape. However, the insulation material must be thin to allow PMT to slide through. The best option we found was to use 1-2 layers of 3/4 kapton tape to cover 6 cm of the inner surface from the opening. Since the kapton tape has thickness of 25.4 µm and a smooth surface, the PMT is able to slide freely into the shield. 3 Ringing Fig. 2(b) shows an example of the H6528 signal output as delivered from the factory. At 2000 V, the ratio between the primary and the first ringing tail is 10:1, this ratio increases as the operating voltage rises. When there is a large pulse (>1V), it is possible for the ringing tailing to trigger the electronic discrimination threshold, particularly at high event rates. It would be optimal to suppress the primary-to-ringing ratio without changing the other PMT signal output characteristics. After some study, we decided upon an electronic modification which satisfies the our requirement. 6

Figure 6: PMT signal output before (black) and after (red) the modification at 2000 V. The oscilloscope trigger was set at 200 mv; both signals were averaged over 16 pulses. The modified H6528 base circuit diagram is attached in App. A. Two 0.01 µf high voltage capacitors are added between dynode chains #10 and #11 and the ground [3]. A 51 Ω metal film resistor is also introduced in series to the signal output; its power rating is 0.6 Watt. Fig. 6 shows the original and modified PMT signal output at 2000 V. The ringing tails after the modification seem to be effectively suppressed to a satisfactory level. 4 Test Results A series of tests were conducted to verify the performance of the H6528 PMT assemblies after modification. No discharges were observed on all four PMTs at a voltage up to 2500 V for a testing period of 3 days. Long term discharge monitoring will be implemented and documented. The PMT gains were repeated after the circuit modification and compared with the results from the initial measurement, the gains were found to be within 2% of the original measurements, which is within our measurement error. 7

5 Conclusion Despite the excellent gain performance, the Hamamatsu H6528 PMT assemblies have two disturbing characteristics: discharge pulses and ringing tails. In this report, we offer our solutions to overcome the issues: we introduced plastic insulation to stop discharge from the µ-shield to the aluminum base; we used kapton tape to insulate the inner surface of the metal shield, thus stopping the discharge from the photo-cathode to the µ-shield; we modified the base circuit to suppress the ringing tails effectively. The modified PMT assemblies show no sign of discharge pulses so far, and the ringing tails are suppressed to a satisfactory level without significantly changing important characteristics of the PMTs. We suggest that the manufacturer investigate and reconsider the available options to eliminate both issues at the production level, if possible. 6 Acknowledgement We are grateful to A. Semenov, D. Gervais, D. Paudyal and D. Day for valuable suggestions and generous help to complete this work. References [1] Hamamatsu Photomultiplier Tube Catalogue, www.hamamatsu.com/photomultiplier. [2] A. Fischer, G. M. Huber, Performance Testing of 5 inch PMTs, HallC-doc-738-v1. [3] Private communication with Dr. A. Semenov. 8

A Circuit Modification for H6528 Tube The following is the modified circuit diagram of H6528 base. 9

10