Model A9GT-70LTTB Back Light

Similar documents
For QnA Ethernet Interface Module

QnA Series Ethernet Interface Module

Point2. Point3. Improve your production efficiency with convenient functions! New functions designed for ease of use are available! New! New! New!

A9GT-QJ71LP23/A9GT-QJ71BR13 Network Unit

MELSECNET/10 Network Module

MELSECASeries A(1S)J71QE71N3-T, A(1S)J71QE71N-B5, A(1S)J71QE71N-B2. Ethernet Interface Module. Programmable Logic Controller. User's Manual (Hardware)

Backlight Replacement

FX2N-2DA SPECIAL FUNCTION BLOCK

Thank you for choosing Mitsubishi Electric Graphic Operation Terminal

8753E, 8753ET, and 8753ES Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit. Applicable Upgrade Kit Model Number

Magelis XBT ZG43 Backlight Replacement Kit Quick Reference Guide

Positioning Module QD75MH1 QD75MH2 QD75MH4. Thank you for buying the Positioning Module.

Installation Instructions. What This Option Provides

VT-S730. Omron's 3D-SJI For Efficient Manufacturing of High-quality Products. Best the Minimum Q cost! PCB Inspection System VT-S730 NEW

Photovoltaic Module Installation Manual (IEC)

Photovoltaic Module Installation Manual (IEC)

Replacing the PanelMate epro PS, PanelMate epro PS EE, and PanelMate epro PS OD 7685x-12 Series Backlight Assembly

Tailored solutions to meet your HMI and visualization needs

MELSEC iq-r Channel Isolated Digital-Analog Converter Module User's Manual (Application) -R60DA8-G -R60DA16-G -RY40PT5B-AS

DATAGAUSS XL HARD DRIVE DEGAUSSER

Replacing the PanelMate epro PS, PanelMate epro PS Classic, PanelMate epro PS EE, and PanelMate epro PS OD 7685x-15xx Series Backlight Assembly

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

ICS Digital Menu. Installation Guide Version 1.1

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

Installation Note. Option GHz Operation Upgrade Kit. For 8753E and 8753ES Network Analyzers. Applicable Upgrade Kit Model Number

6000 Series Patch Panel Terminating Instructions

Industrial Monitor Update Kit

NewScope-7A Operating Manual

TV Lift System Model CL-65 Installation Instructions

Datavideo TLM x 2 TFT LCD Monitors

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

Multi-channel LED driver with integrated boost controller for medium, large LCD panel backlight based on LED7708 and STM32F103C6T6A

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

Document Copyrights. Disclaimer

Additional Information for Using Sony Wall-Mount Bracket (SU-WL500)

FX2N-2AD SPECIAL FUNCTION BLOCK

Vibratory Deck Sieves 15 in. (380 mm)

GaAs MULTI-CHIP MODULE MC-7883

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

MELSEC iq-r Temperature Control Module User's Manual (Application) -R60TCTRT2TT2 -R60TCTRT2TT2BW -R60TCRT4 -R60TCRT4BW

Instructions for Varian Gauge Cable Connector Kits

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

Model: LCD4WM 3.5 Window Mounted LCD Monitor User Manual Features

Proximity Card Reader. User s Manual

Installation Manual SaVi Note Underwater LED Light

DEEPFRAME BASIC KIT- USER MANUAL VERSION ORIGINAL USER MANUAL

Do not submit this electronic data to the customer.

Power Injector 1520 Series

General Wiring and Installation Guidelines. Typical Mounting Installations Electrical Connections General Guidelines Common Questions & Answers

SignalCorrect Software and TCS70902 Calibration Source Option SC SignalCorrect software

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

LH1D Series Surface Mount Indicators

Extended Digitizing Function MS269xA-050 HDD Digitizing Interface

Product Operation Manual

User Manual Color Video Door Phone

TECHNICAL NOTE. What is Wander MEASUREMENT SOLUTIONS ANRITSU CORPORATION


Operation Manual VMS 3.0 Video System

Metal and Glass TV Stand for TVs up to 65 or 110 lbs. NS-HMG1856

e 835 Instruction manual Stage Microphones

Jinyoung Contech Co., Ltd.

Model GS7000 GainMaker Node Forward Local Injection Module Installation Instructions

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

LCD Direct Drive Using HPC

PLL1920M LED LCD Monitor

Installation Guide VL-MV10. Model No.

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

INSTALLATION INSTRUCTIONS FOR

NS-B750. Speaker Enceinte OWNER S MANUAL MODE D EMPLOI BEDIENUNGSANLEITUNG MANUAL DE INSTRUCCIONES

CC-Link IE Field Network Analog-Digital Converter Module User's Manual -NZ2GF2BN-60AD4 -NZ2EX2B-60AD4

HR7012M / HR7012S. Custom Vehicle Headrests with 7 Slim Style LED LCD Satellite Monitors or Built-in DVD Player for Rear Entertainment HR7012M

.Power Distribution Center. PD-1. Instruction Manual

ADF Module. Installation Guide. 1.1 Overview

Business Display Solutions - Institutional Television Mirror TV. Installation Guide for 32PM8822 ( BDL3221M) 42PM8822 (BDL4221M)

STEVAL-IHM025V1. 1 kw 3-phase motor control demonstration board featuring the IGBT SLLIMM STGIPL14K60. Features. Description

CM-S23349SV. Vari-Focal IR Bullet Camera

Introduction. Characteristics (Note 1, 2) Parameters Typical Value Units Conditions

LED LCD COLOUR TELEVISION CONTENTS

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

User s Manual. LG Industrial Systems G3F AT4A. LG Programmable Logic Controller

Outdoor IR Audio Camera

Sirio 150 / 150DV. Code 02E010 - Sirio 150 Code 02E011 - Sirio 150DV OPERATING INSTRUCTIONS. COEF srl. Revision 1

Cyclo Series. user manual. MartinArchitectural

VMA ACTIVE MATRIX TFT COLOR LCD MONITOR OWNER S MANUAL INSTALLATION GUIDE

CM-S38901SV TVL IR Long Range camera

User Manual Color video door phone

VMA573 and VMA or 7 Wide Screen Color LCD Monitor. Owner s Manual. Installation Guide

SmartCrystal Cinema Neo

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

Installation Manual Original Instructions - IW4001

STEVAL-IHM043V1. 6-step BLDC sensorless driver board based on the STM32F051 and L6234. Features. Description

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide

Manual. Kingpad mc-edition light-module. Bus system control pad for installation in the Graupner mc-16 / mc-20 / mc-26 / mc-28 transmitter

WID-DL74 WID-DL74 BLP WID. Designed for. Installation guide for workitdesk interactive table for. BrightLink Pro

Transcription:

Model A9GT-70LTTB Back Light User s Manual Thank you for purchasing the MELSEC-GOT Series. To ensure correct use of this equipment, please carefully read this manual prior to use. MODEL A9GT-70LTT-B-U MODEL CODE 1DM117 IB(NA)-80033-C(0406)MEE Mitsubishi Graphic Operation Terminal

SAFETY PRECAUTIONS (Always read before starting use) Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product. For the safety precautions of the programmable controller system, please read the CPU module user's manual. In this manual, the safety precautions are ranked as "DANGER" and "CAUTION". DANGER CAUTION Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury. Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage. Note that the CAUTION level may lead to a serious consequence according to the circumstances. Always follow the precautions of both levels because they are important to personal safety. Please save this manual to make it accessible when required and always forward it to the end user. A-1

[HANDING PRECAUTIONS] DANGER Before changing the backlight, always switch off the GOT power externally in all phases (when the GOT is connected to the bus, the PLC CPU power must also be switched off externally in all phases) and remove the GOT main unit from the enclosure. Not switching the power off in all phases may cause en electric shock. Not removing the unit from the enclosure can cause injury due to a drop. CAUTION While changing the backlight, do not touch the circuit boards and electronic parts of the GOT. Doing so can cause a failure or malfunction. When changing the backlight, always note the following. Wear gloves or fingerstalls before starting the replacement of the backlight. Not doing so can cause injury. Start changing the backlight more than 5 minutes after switching the GOT power off. Not doing so can cause a burn due to the heat of the backlight. [DISPOSAL PRECAUTIONS] CAUTION When disposing, treat this product as industrial waste. A-2

Revisions * The manual number is noted at the lower left of the back cover. Print Date *Manual Number Revision Jan., 1999 IB(NA)-80033-A First printing Feb., 2003 IB(NA)-80033-B Partial additions Chapter 3 Jun., 2004 IB(NA)-80033-C Partial correction SAFETY PRECAUTION, Manuals, Chapter 2 MODEL CODE change Changed from 13JQ25 to 1DM117 This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual. 1999 MITSUBISHI ELECTRIC CORPORATION A-3

CONTENTS 1. Overview...1 2. Performance...1 3. How to Change the Backlight for Liquid Crystal...2 A-4

Manuals The following manuals are relevant to this product. Refer to the following list and order the required manuals. Detailed Manual Manual name A985GOT/A975GOT/A970GOT/A960GOT User s Manual (Available as option) Manual No. (Model code) SH-4005 (1DM099) Relevant Manual For relevant manual, refer to the PDF manual stored within the drawing software. A-5

1. Overview This user s manual explains the model A9GT-70LTTB backlight (Referred to as backlight, hereafter). This backlight is a replacement backlight for the A975GOT-TBA, A975GOT-TBD, A970GOT-TBA, A970GOT-TBD, A975GOT-TBA-B, A975GOT-TBD-B, A970GOT-TBA-B, A970GOT-TBD-B graphic operation terminal. 2. Preformance The table below lists the performance specifications of the back lights. Item Specifications A975GOT-TBA Applicable *1, A975GOT-TBD *2, A970GOT-TBA *1, A970GOT-TBD models *2, A975GOT-TBA-B, A975GOT-TBD-B, A970GOT-TBA-B, A970GOT-TBD-B Kind Cold cathode tube back light Life [Hr] 40,000 *1: This is applicable for the models of the hardware Version D and above. *2: This is applicable for the models of the hardware Version B and above. (1) How to verify the hardware version Verify the hardware version, referring to the rating nameplate bonded on the rear face of GOT module. GRAPHIC OPERATION TERMINAL MODEL A970GOT-TBD B A IN 24VAC POWER MAX 115VA DATE 9812 B A MITSUBISHI ELECTRIC CORPORATION MADE IN JAPAN BD992C032H16 Hardware Version Applicable hardware version A975GOT/A970GOT-TBA: Ver. D and above A975GOT/A970GOT-TBD: Ver. B and above 1

3. How to Change the Backlight for Liquid Crystal In GOT, back lights are incorporated for the indicator LCD. These back lights lose the luminance as they are used. Replace the back lights if the luminance lowers further than that affects the performance of the indicator screen. The backlight changing method changes depending on the hardware version of the GOT. Change the backlight after confirming the hardware version of the used GOT. Type Hardware Version A97 GOT-TBA(-B) Version K (May, 2001) or earlier, Version R (May, 2002) or later A97 GOT-TBD(-B) Version K (May, 2001) or earlier, Version Q (May, 2002) or later A97 GOT-TBA(-B) Version L (June, 2001) to Version Q (April, 2002) A97 GOT-TBD(-B) Version L (June, 2001 to Version P (April, 2002) (1) Backlight replacement procedure 1 Changing Method Reference Destination (1) (2) 1) Turn off the GOT power supply. Remove the wire from the power terminal. Then remove the communications cable. 2) Loosen the metal fitting on GOT to remove GOT from the cabinet. 3) Use a screw driver and remove four fastening screws on the back of GOT. 2

Top part Bottom part 4) After removing the fastening screws, remove the indicator cover from GOT, while pressing two fastening hooks. 3

a nail -like b Lift the black nail-like part (black) towards the a direction, and pull it out towards the b direction. Remove the cable connector on the back lights from the indicator connector. 5) Show the front face of GOT, and remove the cable connector that is fitted to the upper one of the back lights from the indicator connector. 6) Pull out the upper one of the back lights from the indicator. 7) To install new back lights, follow the procedure opposite to that of removing. Similarly, follow the opposite procedure for installing the indicator. Make sure to securely install the indicator and apply a torque within the specified range to the fastening screws for GOT. 36 to 48N cm (3.7 to 4.9kgf cm)(3.2 to 4.2lb inch) 4

(2) Backlight replacement procedure 2 Remove the screws recognizing each size during backlight replacement, since they have different sizes depending on the mounted positions. Be sure to store the screws by size after removing them. 2) 2) 1) Remove the connector cover for RS-232C interface, printer interface or communication module, if it has been mounted to the GOT. Also, remove the wires connecting cable, various modules or terminal block to the GOT, if the wiring has been installed. GOT rear side 2) Unscrew four fixing screws on the GOT rear side with a driver. (They cannot be completely removed.) (Tightening torque range: 36 to 48N cm) GOT top side GOT bottom side GOT left side GOT right side 3) Remove the display cover from the GOT while pressing four fixing tabs, which are situated on top/bottom/right/left sides of the GOT. A flat cable is attached under the fixing tab on the top side of the GOT. Take care not to apply excessive force on the fixing tabs while pressing them with a driver or similar device. Failure to observe this instruction may damage them. Be sure not to apply excessive pressure on the GOT case, which is made of resin. Failure to observe this instruction may also damage them. (Continued on the next page) 5

(Continued from previous page) 5) 4) Put the GOT on the liquid crystal display side. Keep the liquid crystal display away from scratch or dirt by laying a sheet on the work table in advance. 6) 5) Remove two screws from the rear side. ((M2.6 screw)10 to 13N cm) GOT rear side 6) Remove two screws from the rear side. ((M3 screw)18 to 24N cm) Please note that the screws are different in size. 7) Put the liquid crystal display side up and then remove the cable connector for backlight. Remove the cable connector for backlight. 8) 8) 8) Remove four screws (chassis mounting screw) on the outmost side. (Tightening torque range: 36 to 48N cm) (Continued on the next page) 6

(Continued from previous page) 9) Remove the liquid crystal display and circuit board from the rear case by holding up the top side. 10) Remove the backlights keeping the liquid crystal display up. Keep the liquid crystal display away from scratch or dirt by laying a sheet on the work table in advance. Pull out the backlight in b direction pressing the fixing tab (black) in a direction. a b 11) Mount new backlight(s) in a reverse order to the removal procedures. Then, mount the liquid crystal display, circuit board and display cover in a reverse order as well. *1 Be sure to securely mount the liquid crystal display, circuit board and display cover, and tighten the fixing screws within the specified torque range. *1: Pay full attention to the followings while mounting the liquid crystal, circuit board and display cover. Insert the GOT connectors and terminals into the corresponding holes on the rear case when mounting liquid crystal and circuit board onto it. Be sure to gently tighten the screws mentioned in 8) and 2), and then retighten them within the specified torque range. Insert the cable connectors for backlights completely, making sure that it is correctly mounted. Attach the display cover taking care that the flat cable is not pinched` between the GOT and display cover. Remove the dust from the liquid crystal display or inside of the front panel. 7

Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties. For safe use This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life. Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi. This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system. Country/Region Sales office/tel U.S.A Mitsubishi Electric Automation Inc. 500 Corporate Woods Parkway Vernon Hills, IL 60061 Tel : +1-847-478-2100 Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. AV. Paulista 1471, Conj. 308, Sao Paulo City, Sao Paulo State, Brazil Tel : +55-11-283-2423 Germany Mitsubishi Electric Europe B.V. German Branch Gothaer Strasse 8 D-40880 Ratingen, GERMANY Tel : +49-2102-486-0 U.K Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, Hatfield, Herts., AL10 8XB,UK Tel : +44-1707-276100 Italy Mitsubishi Electric Europe B.V. Italian Branch Centro Dir. Colleoni, Pal. Perseo-Ingr.2 Via Paracelso 12, 20041 Agrate B., Milano, Italy Tel : +39-039-6053344 Spain Mitsubishi Electric Europe B.V. Spanish Branch Carretera de Rubi 76-80 08190 - Sant Cugat del Valles, Barcelona, Spain Tel : +34-93-565-3131 France Mitsubishi Electric Europe B.V. French Branch 25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France TEL: +33-1-5568-5568 South Africa Circuit Breaker Industries LTD. Tripswitch Drive, Elandsfontein Gauteng, South Africa Tel : +27-11-928-2000 Country/Region Sales office/tel Hong Kong Ryoden Automation Ltd. 10th Floor, Manulife Tower, 169 Electric Road, North Point, HongKong Tel : +852-2887-8870 China Ryoden Automation Shanghai Ltd. 3F Block5 Building Automation Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China Tel : +86-21-6475-3228 Taiwan Setsuyo Enterprise Co., Ltd. 6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, Taipei Hsine, Taiwan Tel : +886-2-2299-2499 Korea HAN NEUNG TECHNO CO.,LTD. 1F Dong Seo Game Channel Bldg., 660-11, Deungchon-dong Kangsec-ku, Seoul, Korea Tel : +82-2-3660-9552 Singapore Mitsubishi Electric Asia Pte, Ltd. 307 ALEXANDRA ROAD #05-01/02, MITSUBISHI ELECTRIC BUILDING SINGAPORE 159943 Tel : +65-6473-2308 Thailand F. A. Tech Co.,Ltd. 898/28,29,30 S.V.City Building,Office Tower 2,Floor 17-18 Rama 3 Road, Bangkpongpang, Yannawa, Bangkok 10120 Tel : +66-2-682-6522 Indonesia P.T. Autoteknindo SUMBER MAKMUR Jl. Muara Karang Selatan Block A Utara No.1 Kav. No.11 Kawasan Industri/ Pergudangan Jakarta - Utara 14440 Tel : +62-21-663-0833 India Messung Systems Put,Ltd. Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,PUNE-411026 Tel : +91-20-712-2807 Australia Mitsubishi Electric Australia Pty. Ltd. 348 Victoria Road, PostalBag, No 2, Rydalmere, N.S.W 2116, Australia Tel : +61-2-9684-7777 HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission. Specifications subject to change without notice. Printed in Japan on recycled paper.