Signalling Devices. 516 Signalling Devices KP00 III en Preferred products in stock or available at short notice

Similar documents
Explosion Proof Audible Signal db(a) Series YA60

Explosion Proof Audible Signal db(a) Series YA60

Pendant Light Fitting IEC Series 6470/2

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Pendant Light Fittings Series 6050

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

7 Lighting Technology

EXPlora. Introduction

EXLUX ECOLUX 6480 Series

EXLUX ECOLUX C-LUX 6480 Series

Horn loudspeaker, Ex proof, short/long flare

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

Optical Signal Devices. Free-standing Beacons

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

8 Installation Equipment

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Circuit-Breakers for Motor Protection Series 8523/8

XML LED X M L L E D. Explosionproof Linear LED Lighting

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Motor Protection Circuit Breaker Series 8146/5-V27

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

Operating instructions

Model JDF Field Indicator

Flow Measurement SITRANS F M

TYPE APPROVAL CERTIFICATE

Inductive sensor NI3-EG08K-Y1-H1341

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Inductive sensor BI1.5-EG08K-Y1

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

I Ex-protected connectors exlink I

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

PROPORTIONAL VALVES Sentronic plus

Champ-Pak Wall Pack Luminares

PRE Series 16 Amp Plugs and Sockets Increased Safety

Process Transmitter RMA 422

Installation instructions Cable transit device Roxtec RS ES Ex

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

Pressure transmitter For applications in hazardous areas Model IS-3

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Installation instructions Ex frames

Inductive sensor NI10-M18-Y1X-H1141

Level Measurement Point level measurement - RF Capacitance switches

LIGHTING SOLUTIONS. The bright side of the ship

TECHNICAL DATA. Type. TMC2X Design Specification. Category B ATEX Certificate. Code of Protection. IECEx SIR X Code of Protection

EX-PROTECTED PORTABLE POWER SUPPLY UNITS

General Specifications

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Illustrated Feature. Options

Process transmitter RMA422

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Installation instructions Roxtec RS ES Ex

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Inductive sensor With analog output BI15-M30-LI-EXI

associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix

Panel Mount Signaling Alarms

Product Data Sheet 4656 ZW

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

VDI structed cabling system and warning devices. Flashing and rotating lights. Industrial bells (P. 324) (P. 325) VDI structured cabling system

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Product Data Sheet 8506 VW-691

ENCODERS FOR OIL & GAS

Flow Measurement SITRANS F M

ExCam XPT Q6055. User Manual

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

PMG. Vibration Energy Harvesters

STROBE SIGNAL LIGHT. Catalog Number Logic ES X (CEN)* Series Constant. Signal Type X Strobe

NEW NEW NEW. Page 137. Page 138. Page 128. Page 136. Page 134. Page 134 Page 139

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Safety dialogue solutions

Absolute Encoders Multiturn

Linear flow control with actuator IFC

Loudspeakers. < Makes the world sound >

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

TFRN Industrial RTD temperature sensor. CombiTemp TM

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

USER MANUAL FOR EXPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE PLFM -.

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Datasheet EC-750 Ex DOME Camera

LIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances

Product Data Sheet 4656 EZ

82540/ /2-way diaphragm valves

Level Measurement Point level measurement RF Capacitance switches

Linear flow controls VFC Linear flow controls with actuator IFC

WLB SERIES HID Lighting for Hose Down Applications

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Eddy Current Probe System

Safety Light Curtains GuardShield

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Transcription:

516

Contents Audible and Visual Yodalex Super Series, GRP Combination Signal - 110 db(a) / 5 Joule YL6S 518 Sounder / Strobe, Combination - 110 db(a) / 5 Joule YL60 523 Intrinsically Safe Combination Signal - 100 db(a) / LED Beacon YL4IS 527 Intrinsically Safe Combination Signal - 105 db(a) / LED Beacon YL5IS 527 Audible Intrinsically Safe Sounder, 100 db(a) YO3IS 527 Intrinsically Safe Sounder, 100 db(a) Modular YO4IS 527 Intrinsically Safe Sounder, 105 db(a) YO5IS 527 Sounder, 115 db(a) YA90 534 Yodalex Super Series, GRP Flameproof Audible Signal - 110 db(a) YA6S 518 Sounder, 110 db(a) YA60 523 Sounder - 100 db(a) - Hazardous Area YA11 532 Hazardous Area Loudspeaker - 25 or 15 W 8494 538 Signal Horn, 105 db(a) 8491 542 Visual Yodalex Super Series, GRP Flameproof Visual Signal - 5 Joule FL6S 518 Strobe, Flash Energy 5 Joule FL60 523 GRP Explosion Proof Visual Signal 5 Joule FX15 544 Flashing Beacon and Continuous Beacon 6161 548 Signal Beacon - LED 6162 551 LED Obstruction Light, Low Intensity TEF 2430 558 Obstruction Light LED TEF 2460 564 Signal Beacon TEF 2430 560 Signal Beacon - Zone 2 TEF 2440 562 Perimeter Light - LED TEF 2460 565 LED Visual Flashing Signal, Intrinsically Safe FD40IS 555 LED Visual Status Signal, Intrinsically Safe SD40IS 555 Navigation Light TEF 2850 566 Windsock Illuminated TEF 9967 568 Windsock with Internal Illumination TEF 9968 570 Control Devices Manual Call Points MCP 572 You will find further information on the Internet www.stahl.de Audible Sounder 8493 Visual Traffic Light 6091 Control Devices Fire Alarm Stations 8146 517

Yodalex Super Series Series YL6S, YA6S, FL6S & > Corrosion resistant light-weight Ex d enclosure made of glass-fibre reinforced polyester > Extreme temperature range > IP66 & IP67 > Stainless steel wire guard and mounting bracket supplied as standard > ATEX & IECEx approvals Series YL6S, YA6S, FL6S 16586E00 WebCode WebCode WebCode YL6SA YA6SA FL6SA ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x Versions 17611E00 17612E00 17613E00 YL6S GRP Flameproof Combination Signal YA6S GRP Flameproof Audible Signal FL6S GRP Flameproof Visual Signal Selection Table Version 17614E00 GRP Flameproof combination signal - 110 db(a) / 5 Joule Note Gas group Rated operational voltage Lens colour IIC 24 V DC red YL6S/C-D-050-R-EN- SF-A-ST-00-00-00 amber YL6S/C-D-050-A-EN- SF-A-ST-00-00-00 48 V DC red YL6S/C-F-050-R-EN- SF-A-ST-00-00-00 amber YL6S/C-F-050-A-EN- SF-A-ST-00-00-00 115 V AC red YL6S/C-L-050-R-EN- SF-A-ST-00-00-00 amber YL6S/C-L-050-A-EN- SF-A-ST-00-00-00 230 V AC red YL6S/C-N-050-R-EN- SF-A-ST-00-00-00 amber YL6S/C-N-050-A-EN- SF-A-ST-00-00-00 Variations in gas group, flash energy, voltage and lens colour are available, please use the Selection Table The tone table is available on the Internet. Order number Art. no. PS Weight kg 225075 80 4.440 225076 80 4.440 225086 80 4.440 225087 80 4.440 225104 80 4.440 225105 80 4.440 225112 80 4.440 225113 80 4.440 518

& Selection Table Version 17619E00 GRP Flameproof audible signal - 110 db(a), 17620E00 GRP Flameproof visual signal - 5 Joule Note Gas group Rated operational voltage Lens colour IIC 24 V DC YA6S/C-D-EN-SF-A- ST-00-00-00 48 V DC YA6S/C-F-EN-SF-A- ST-00-00-00 115 V AC YA6S/C-L-EN-SF-A- ST-00-00-00 230 V AC YA6S/C-N-EN-SF-A- ST-00-00-00 IIC 24 V DC red FL6S/C-D-050-R-EN- SF-A-ST-00-00-00 amber FL6S/C-D-050-A-EN- SF-A-ST-00-00-00 48 V DC red FL6S/C-F-050-R-EN- SF-A-ST-00-00-00 amber FL6S/C-F-050-A-EN- SF-A-ST-00-00-00 115 V AC red FL6S/C-L-050-R-EN- SF-A-ST-00-00-00 amber FL6S/C-L-050-A-EN- SF-A-ST-00-00-00 230 V AC red FL6S/C-N-050-R-EN- SF-A-ST-00-00-00 amber FL6S/C-N-050-A-EN- SF-A-ST-00-00-00 Variations in gas group, flash energy, voltage and lens colour are available, please use the Selection Table The tone table is available on the Internet. Yodalex Super Series Series YL6S, YA6S, FL6S Order number Art. no. PS Weight kg 225182 80 3.640 225183 80 3.640 225184 80 3.640 225185 80 3.640 225149 80 3.040 225150 80 3.040 225157 80 3.040 225158 80 3.040 225165 80 3.040 225166 80 3.040 225173 80 3.040 225174 80 3.040 519

Yodalex Super Series Series YL6S, YA6S, FL6S & Technical Data Explosion protection Global (IECEx) Gas and dust IECEx BAS 14.0064 IEC 60079-0: 2011 / IEC 60079-1: 2007 / IEC 60079-31: 2013 Ex d IIB T* Ta -**... +** C Gb Ex d IIC T* Ta -**... +** C Gb Ex tb IIIC T*** C Ta -**... +** C Db IP66 Europe (ATEX) Gas and dust Certifications and certificates Certificates Design Product variant table Design Product variant table Design Product variant table Baseefa14ATEX0126 EN 60079-0: 2012 / EN 60079-1: 2007 / EN 60079-31: 2009 (IEC 60079-31: 2013) E II 2 G Ex d IIB T* Ta -**... Ta +** C Gb E II 2 G Ex d IIC T* Ta -**... Ta +** C Gb E II 2 D Ex tb IIIC T*** C Ta -**... +** C Db IP66 IECEx, ATEX YL6S Power and Temperature Max. surface Ambient temperature voltage class temperature range 24 V DC T6 T75 C -60 +70 C 48 V DC T6 T75 C -60 +70 C 115 V AC T6 T77 C -60 +60 C T5 T87 C -60 +70 C 240 V AC T6 T77 C -60 +60 C T5 T87 C -60 +70 C FL6S 5 J 24 V DC T6 T73 C -60 +40 C T5 T88 C -60 +55 C T4 T103 C -60 +70 C 5 J 48 V DC T6 T73 C -60 +40 C T5 T88 C -60 +55 C T4 T103 C -60 +70 C 5 J 115 V AC T5 T83 C -60 +40 C T4 T113 C -60 +55 C 5 J 230 V AC T6 T75 C -60 +40 C T5 T90 C -60 +55 C T4 T105 C -60 +70 C Design YL6S YA6S FL6S Ambient conditions Operating temperature range Certified hazardous area protection temperatures Power and Temperature Max. surface Ambient temperature voltage class temperature range 5 J 24 V DC T5 T95 C -60 +40 C T4 T110 C -60 +55 C 5 J 48 V DC T5 T95 C -60 +40 C T4 T110 C -60 +55 C 5 J 115 V AC T5 T95 C -60 +40 C T4 T110 C -60 +55 C 5 J 230 V AC T5 T95 C -60 +40 C T4 T110 C -60 +55 C YA6S Power and voltage Temperature class 24/48 V DC -50... +55 C 115 V AC -40... +45 C 230 V AC -40... +55 C For further information see the operation manual Max. surface temperature 24/48 V DC -60... +70 C 115 V AC -40... +60 C 230 V AC -40... +60 C For further information see the operation manual Ambient temperature range 24/48 V DC -50... +70 C 115 V AC -55... +55 C 230 V AC -55... +70 C For further information see the operation manual 520

& Yodalex Super Series Series YL6S, YA6S, FL6S Design YL6S YA6S FL6S Electrical data Rated operational voltage Current consumption 24 or 48 V DC 115 or 230 V AC 24 or 48 V DC 115 or 230 V AC Operational parameters + / -10 % + / -10 % + / -10 % Line monitoring yes yes yes Acoustic data Volume max. 110 db(a) max. 110 db(a) Volume control 18 db(a) adjustment 18 db(a) adjustment Sound stages 24 / 48 V DC 3 24 / 48 V DC 3 115 / 230 V AC 2 115 / 230 V AC 2 24 or 48 V DC 115 or 230 V AC Sound selection via DIL switch via DIL switch Luminous characteristics Light source Xenon flash tube Xenon flash tube Flash energy 5 J 5 J Flash rate 1/s 1/s Light intensity Effective Candela Effective candela seconds candela (cd) (cd) clear 49 9.96 Lens colour 24 V DC 600 ma 48 V DC 420 ma 115 V AC 280 ma 230 V AC 115 ma * tone 1 amber, red, green, opal, blue, clear, yellow, magenta 24 V DC 280 ma 48 V DC 250 ma 115 V AC 76 ma 230 V AC 40 ma 24 V DC 320 ma 48 V DC 170 ma 115 V AC 204 ma 230 V AC 75 ma Candela seconds clear 49 9.96 amber, red, green, opal, blue, clear, yellow, magenta Mechanical data Material Enclosure glass reinforced polyester glass reinforced polyester glass reinforced polyester Horn and trumpet flame retardant ABS flame retardant ABS Lens cover polycarbonate polycarbonate Wire guard stainless steel stainless steel Assembly parts stainless steel stainless steel stainless steel Bracket stainless steel stainless steel stainless steel Labels polyester foil, adhesive polyester foil, adhesive polyester foil, adhesive Degree of protection IP66 / IP67 acc. to IEC 60529 Mounting / Installation Connection 2.5 mm 2 terminals Accessories and Spare Parts Designation Figure Description Art. no. PS Weight kg Xenon tube Replacement xenon tube assembly 223636 80 0.006 PCB 15798E00 PCB assembly 24 V DC 5J 223635 80 0.080 PCB assembly 48 V DC 5J 223634 80 0.080 15786E00 PCB assembly 110 V AC 5J 223632 80 0.118 PCB assembly 230 V AC 5J 223580 80 0.100 PCB termination PCB assembly termination 223579 80 0.020 15785E00 521

Yodalex Super Series Series YL6S, YA6S, FL6S & Dimensional Drawings (All Dimensions in mm [inches]) Subject to Alterations 105 [4,13] [6,12] 155,50 75 [2,95] Ø9 [ Ø0,35] 117 [4,61] 95 [3,74] 189 [7,44] Ø145 [ Ø5,70] 403 [15,87] 178,50 [7,03] 105 [4,13] [6,12] 155,50 75 [2,95] Ø9 [ Ø0,35] 33 [1,30] 117 [4,61] 95 [3,74] 189 [7,44] Ø145 [ Ø5,70] 263,50 [10,37] 178,50 [7,03] 17150E00 40 [1,57] 105 [4,13] 117 [4,61] 75 [2,95] 189 [7,44] Ø9 [ Ø0,35] 95 [3,74] 178,50 [7,03] 287,50 [11,32] 17149E00 GRP Combination Signal Series YL6S with L-Bracket 17151E00 GRP Audible Signal Series YA6S with L-Bracket GRP Visual Signal Series FL6S with L-Bracket 3 x M6 32 [1,26] 178,50 [7,03] 75 [2,95] 403 [15,87] 3 x M6 33 [1,30] 178,50 [7,03] 75 [2,95] 263,50 [10,37] 32 [1,26] 3 x M6 178,50 [7,03] 148 [5,83] 40 [1,57] Ø145 [ 5,70] Ø 32 [1,26] 75 [2,95] Ø145 [ 5,70] Ø 16919E00 16920E00 GRP Combination Signal Series YL6S without L-Bracket 20 [ 0, 79] 117 [4,61] 17148E00 GRP Audible Signal Series YA6S without L-Bracket GRP Visual Signal Series FL6S without L-Bracket 75 [ 2, 95 ] 105 [ 4, 13 ] L-Bracket ø9 [ ø0, 35] 17159E00 522

& Audible and Visual Alarms Series FL60, YA60, YL60 Series FL60, YA60, YL60 WebCode WebCode WebCode FL60B YA60A YL60A 15195E00 > Audible and visual alarms Sounder Strobe Sounder/strobe combination > Omnidirectional high output sounder 110 db(a) / 1 m > 32 selectable tones meeting international regulations > Lens available in seven different colours > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > Lens guard and mounting bracket supplied as standard > Telephone initiate option available ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 For use in x x x x For use in x x x x For use in x x x x x x Versions 13974E00 14717E00 13969E00 FL60 Strobe YA60 Sounder YL60 Sounder/Strobe combination 523

Audible and Visual Alarms Series FL60, YA60, YL60 & Selection Table Version Group Flash energy 13974E00 FL60 Strobe, ATEX certification, standard devices Rated operational voltage Lens colour Order number Art. no. PS Weight kg IIB + H 2 5 Joule 24 V DC amber FL60/C/D50/A/EU 205129 80 5.080 red FL60/C/D50/R/EU 205133 80 5.080 115 V AC amber FL60/C/L50/A/EU 212366 80 5.080 red FL60/C/L50/R/EU 205145 80 5.080 230 V AC amber FL60/C/N50/A/EU 205150 80 5.080 red FL60/C/N50/R/EU 205153 80 5.080 Selection Table Version Group Rated operational voltage Order number Art. no. PS Weight kg IIB + H 2 24 V DC YA60/C/D/EU 205191 80 5.400 115 V AC YA60/C/L/EU 205199 80 5.400 230 V AC YA60/C/N/EU 205200 80 5.400 14717E00 YA60 Sounder, ATEX certification, standard devices Selection Table Version Group Flash energy Rated operational voltage Lens colour Order number Art. no. PS Weight kg IIB + H 2 5 Joule 24 V DC amber YL60/C/D50/A/EU 205250 80 6.000 red YL60/C/D50/R/EU 205257 80 6.000 115 V AC amber YL60/C/L50/A/EU 205267 80 6.000 red YL60/C/L50/R/EU 205271 80 6.000 230 V AC amber YL60/C/N50/A/EU 205273 80 6.000 red YL60/C/N50/R/EU 205282 80 6.000 13969E00 YL60 Sounder/ Strobe combination, ATEX certification, standard devices Note Variations in gas group, flash energy, voltage and lens colour are available, please use the Selection Table The tone table is available on the Internet. 524

& Audible and Visual Alarms Series FL60, YA60, YL60 Technical Data Explosion protection Global (IECEx) Gas and dust IECEx BAS 05.0087X IIB+H2 Ex d IIB+H2 T4 Gb (Ta = -20 +60 C) Ex tb IIIC T135 C Db IP 66 (Ta = -20 +60 C) Ex d IIB+H2 T6 Gb (Ta = -20 +40 C) Ex tb IIIC T85 C Db IP 66 (Ta = -20 +40 C) Europe (ATEX) Gas and dust Certifications and certificates Certificates Electrical data Rated operational voltage Rated operational current Baseefa 02ATEX0222X IIB+H2 EII 2 G Ex d IIB+H2 T4 Gb (Ta = -20 +60 C) EII 2 D Ex tb IIIC T135 C Db IP 66 (Ta = -20 +60 C) EII 2 G Ex d IIB+H2 T6 Gb (Ta = -20 +40 C) EII 2 D Ex tb IIIC T85 C Db IP 66 (Ta = -20 +40 C) IECEx, ATEX, Brazil (INMETRO), India (PESO), Taiwan (ITRI), USA (UL) 24 V DC, 48 V DC, 115 V AC and 230 V AC operational parameters + or -10 % YL60 YA60 24 V DC 570 ma 350 ma 48 V DC 435 ma 300 ma 115 V AC 200 ma 110 ma 230 V AC 100 ma 55 ma Acoustic data Volume Sound selection Luminous characteristics Effective candela Flash energy Flash rate FL60 24 V DC 5 J 220 ma 10 J 500 ma 20 J 1100 ma 48 V DC 5 J 135 ma 10 J 300 ma 20 J 560 ma 115 V AC 5 J 90 ma 10 J 105 ma 20 J 260 ma 230 V AC 5 J 45 ma 10 J 53 ma 20 J 107 ma 110 db(a) / 1 m via DIL-switch FL60 YL60 5 J 5 J Clear lens 30 cd Clear 30 cd Yellow lens 29 cd Yellow 29 cd Amber lens 17 cd Amber 17 cd Red lens 9 cd Red 9 cd Blue lens 6 cd Blue 6 cd Green lens 7 cd Green 7 cd No figures for Magenta lens No figures for Magenta or Opal lens 10 J Clear lens 96.02 cd 20 J Clear lens 301 cd FL60: 5, 10 or 20 Joule YL60: 5 Joule 60 FPM 525

Audible and Visual Alarms Series FL60, YA60, YL60 & Technical Data Ambient conditions Ambient temperature T4: -20... +60 C T6: -20... +40 C Mechanical data Material Enclosure aluminium, seawater resistant Horn ABS, flame retardant Lens cover polycarbonate Fixings stainless steel Mounting bracket mild steel with black polyester powder coat finish; supplied as standard Product label metalised polyester UL certified variants supplied with stainless steel label Degree of protection IP66 IEC 60529 NEMA 4X UL 50 Cable entries 2 cable entries, equipped with stopping plug (1x) and dust cap (1x) UL devices: equipped with M20 / 1/2 adapters (2x) Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 75 [2,95] M8 276 [10,87] 75 [2,95] M8 288 [11,34] 75 [2,95] M8 420 [16,54] 145 [5,71] 145 [5,71] 145 [5,71] 13978E00 13975E00 13977E00 FL60 Strobe YA60 Sounder YL60 Sounder/Strobe combination Accessories and Spare Parts Designation Figure Description Order number Art. no. PS WebCode Cable glands Ex d & Ex e Compound barrier cable gland CMP-20PXSS2K 109441 10 PXSS2KA for all types of unarmoured and braid armour cables (nickel plated brass) Note 15793E00 Ex d & Ex e Compound barrier cable gland for all types of armoured cables (SWA, braided, tape) 15791E00 (nickel plated brass) Approvals of cable entries have to be observed. CMP-20PX2K 109428 10 PX2KA 526

& Intrinsically Safe Audible and Visual Alarms Series YO3IS, YO4IS, YO5IS, YL4IS, YL5IS Series YO3IS, YO4IS, YO5IS, YL4IS, YL5IS 13989E00 > Intrinsically safe Sounders and Sounder/Strobe combinations > High sound output > 32 selectable tones meeting international regulations > Meets UKOOA/PFEER requirements > Sound selection via DIL switch > Lens of Sounder/Strobe combinations available in six different colours > Monitoring facility > Stainless steel fixings > Flame retardant ABS enclosure > Robust and reliable WebCode WebCode WebCode YL5ISA YL4ISA YO5ISA ATEX Zone 0 1 2 20 21 22 For use in x x x x x x WebCode WebCode YO4ISA YO3ISA Selection Table Version Enclosure colour Safety barrier Temperature class Order number Art. no. PS Weight kg red flame (RF) ISC T4 YO3/ISC/T4 205308 81 0.390 T6 YO3/ISC/T6 207019 81 0.390 YO3IS Sounder, ATEX certification, standard devices 13995E00 Selection Table Version Enclosure colour Safety barrier Temperature class Order number Art. no. PS Weight kg red normal (RN) ISC T4 YO4/ISC/T4 205310 81 0.490 T6 YO4/ISC/T6 205311 81 0.490 YO4IS Sounder, ATEX certification, standard devices 15239E00 527

Intrinsically Safe Audible and Visual Alarms Series YO3IS, YO4IS, YO5IS, YL4IS, YL5IS & Selection Table Version Enclosure colour Safety barrier Temperature class Order number Art. no. PS Weight kg red flame (RF) ISC T4 YO5/ISC/T4 205312 81 0.810 T6 YO5/ISC/T6 205315 81 0.810 YO5IS Sounder, ATEX certification, standard devices 13996E00 Selection Table Version Enclosure colour Safety barrier Temperature class Lens colour Order number Art. no. PS Weight kg red normal (RN) ISC T4 amber YL4/ISC/T4/A/RN 211533 81 0.640 red YL4/ISC/T4/R/RN 205450 81 0.640 green YL4/ISC/T4/G/RN 212118 81 0.640 opal YL4/ISC/T4/O/RN 212120 81 0.640 blue YL4/ISC/T4/B/RN 212142 81 0.640 clear YL4/ISC/T4/C/RN 212119 81 0.640 YL4IS Sounder/Strobe, ATEX certification, standard devices 15240E00 Selection Table Version Enclosure colour Safety barrier YL5IS Sounder/Strobe, ATEX certification, standard devices Note 13998E00 Temperature class Lens colour Order number Art. no. PS Weight kg red flame (RF) ISC T4 amber YL5/ISC/T4/A/RF 204795 81 1.090 Variations in gas group, flash energy, voltage and lens colour are available. Please contact your local sales office for details. The tone table is available on the Internet. red YL5/ISC/T4/R/RF 204796 81 1.090 green YL5/ISC/T4/G/RF 212415 81 1.090 opal YL5/ISC/T4/O/RF 212416 81 1.090 blue YL5/ISC/T4/B/RF 212417 81 1.090 clear YL5/ISC/T4/C/RF 212418 81 1.090 528

& Intrinsically Safe Audible and Visual Alarms Series YO3IS, YO4IS, YO5IS, YL4IS, YL5IS Technical Data Explosion protection Europe (ATEX) Gas and dust YO3IS, YO4IS, YO5IS YL4IS, YL5IS BAS02ATEX1190X Baseefa08ATEX0194X Certifications and certificates Certificates Electrical data Rated operational voltage Current consumption Certified input parameters YO*/IS*/T4 YO*/IS*/T6 YL4IS, YL5IS ATEX, India (PESO) E II 1 G Ex ia IIC T4 Ga E II 1 D Ex ia IIIC T190 C Da E II 1 G Ex ia IIC T6 Ga E II 1 D Ex ia IIIC T75 C Da E II 1 G Ex ia IIC T4 Ga E II 1 D Ex ia IIIC T190 C Da 18... 24 V DC Power Certified barrier / Current consumption Sound output db(a)/1 m supply isolator parameters YO5IS YO4IS YO3IS YO5IS YO4IS, YO3IS 24 V DC 28 V / 300 Ω 28 ma 25 ma 25 ma 103 db(a)/1 m 100 db(a)/1 m 18 V DC 28 V / 300 Ω 21 ma 20 ma 19 ma 99 db(a)/1 m 98 db(a)/1 m Power Certified barrier / Current consumption Sound output db(a)/1 m supply isolator parameters tone 1 *) YL5IS, YL4IS YL5IS YL4IS 24 V DC 28 V / 300 Ω 24 ma 100 db(a)/1 m 99 db(a)/1 m 18 V DC 28 V / 300 Ω 33 ma 97 db(a)/1 m 94 db(a)/1 m *) combined supply YO5IS, YO4IS YO3IS U i = 30 V I i = 133 ma P i = 0.7 W C i = 0 L i = 0 Acoustic data Volume YL5IS, YL4IS Independent wiring Combined beacon sounder supply U i = 30 V 30 V 30 V I i = 200 ma 133 ma 133 ma P i = 0.7 W 0.7 W 0.7 W C i = 0 0 0 L i = 0 0 0 YO3IS, YO4IS, YL4IS: max. 100 db(a) YO5IS, YL5IS: max. 105 db(a) Volume control 15 db(a) adjustment (T4 Models only) Sound stages 2 Sound selection via DIL-switch Luminous characteristics Version YL5IS, YL4IS Light source 8 array LED Flash rate 1/s Lens colour amber, red, green, opal, blue, clear Ambient conditions Operating -25... +40 C temperature range Storage temperature -40... +70 C Max. relative humidity 95 % at 40 C 529

Intrinsically Safe Audible and Visual Alarms Series YO3IS, YO4IS, YO5IS, YL4IS, YL5IS & Technical Data Mechanical data Cable entries Material Enclosure Assembly parts Labels Degree of protection Accessories and Spare Parts 1 x M20 ABS, flame retardant stainless steel fixings polyester foil, adhesive YO3IS, YO4IS, YL4IS: IP55 acc. IEC 60529 YO5IS, YL5IS: IP56 acc. IEC 60529 Designation Figure Description Order number Art. no. PS WebCode Safety barrier single channel 9001/01-280-085-101 158351 20 9001A dual channel 9002/11-280-186-001 158848 20 9002A 02326E00 Galvanic isolator single channel 9176/10-15-00s 160472 21 9176A dual channel 9176/20-15-00s 165567 21 9176A Cabel gland 12530E00 8161/8-M20-1304 4... 13 mm 2 50 pieces (delivery lot *) ) 8161/8-M20-1304 239164 10 8161A 13027E00 *) Purchase order quantity in [pieces], the delivery quantity is automatically rounded to the delivery lot. 530

& Intrinsically Safe Audible and Visual Alarms Series YO3IS, YO4IS, YO5IS, YL4IS, YL5IS Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 85 [3,35] 9 [0,35] 118 [4,65] 102 [4,02] 89 [3,50] 128 [5,04] 9 [0,35] 169 [6,65] 153 [6,02] 136 [5,35] M20 89 [3,50] 18 [0,71] ø 6 [ø 0,24] 136 [5,35] ø 8 [ø 0,32] M20 25 [0,98] YO3 Sounder 14001E00 YO5 Sounder 14011E00 91,50 [3,60] 82,50 [ 3,25] 183 [7,20] 13999E00 YO4 Sounder 128 [5,04] 88 [3,46] 169 [6,65] 153 [6,02] 136 [5,35] 88 [3,46] 91,50 [3,60] 82,50 [3,25] 136 [5,35] 194,50 [7,66] ø 8 [ø 0,32] 274,50 [10,81] M20 9 [0,35] 25 [0,98] YL5 Sounder/Strobe combination 14002E00 YL4 Sounder/Strobe combination 16643E00 Note Non-Ex versions can be found in the catalogue Audible & Visual Signals. 531

Hazardous Area Audible Signal - 100 db(a) Series YA11 & Series YA11 14821E00 > Max sound output 100 db(a) / 1 m > IP66, NEMA 4X rated as standard > Single stage alarm > 32 sound tones available meeting international regulations > Low profile (28 mm) light weight aluminium enclosure > 3 metre (118 ) 2 core pre wired cable fitted and prepared ready for installation > Panel sealing gasket and fixings provided > Low current consumption > High performance red paint finish as standard WebCode YA11A ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 For use in x x For use in x x For use in x x x x Selection Table Version Enclosure colour Rated operational voltage Order number Art. no. PS Weight kg YA11 Sounder, standard devices red standard (R) 18... 32 V DC YA11/1-D-..-RN 211439 80 1.700 Note The tone table is available on the Internet. Technical Data Explosion protection Global (IECEx) Gas and dust IECEx BAS 11.0058X Ex na IIC T4 Gc Ex tc IIIC T90 C Dc IP66 (-40 C (Ta (+70 C) Europe (ATEX) Gas and dust Customer must specify the required sound tone at the point of ordering. The sound tone cannot be changed by the customer. There are 32 tones available, please see the order number supplement below, for example if tone 18 is required please use the order number YA11/1-D-18-RN Baseefa 10 ATEX 0252X E II 3 GD Ex na IIC T4 Gc Ex tc IIIC T90 C Dc (-40 C ( Ta ( +70 C) Certifications and certificates Certificate IECEx, ATEX, Canada ( CUL), USA (UL) Ship approval Lloyds Register Electrical data Rated operational voltage 24 V DC (18... 32 V DC) Current consumption 70 ma Acoustic data Volume 100 db(a) / 1 m Ambient conditions Operating temperature range -40... +70 C Mechanical data Material Enclosure aluminium / ABS Assembly parts stainless steel fixings and foam sealing gasket Degree of protection IP66, NEMA 4X 532

& Technical Data Mounting / Installation Assembly Hazardous Area Audible Signal - 100 db(a) Series YA11 3 metre (118 ) 2 core pre wired cable fitted and prepared ready for installation to ensure the integrity of seal between the sounder and panel is maintained, the neoprene sponge gasket should be fitted and a torque value of 2.2 to 2.6 Nm (19.5 to 23.0 lbs ins) applied to each screw and nut panel mount via 6 holes on 124 mm (4.9 ) PCD at 60 spacing Panel cut out 109 mm (4.3 ) panel sealing gasket supplied mounting hardware supplied screws are designed to fit a panel thickness of 4 mm max. Tone Table Tone no. Version Frequency Repetition rate (sec) Special application Tone 01 Alternate two-tone 800-1000 0.5 Fire alarms - Level crossing Tone 02 Alternate two-tone 2500-3100 0.5 Security alarms Tone 03 Alternate fast two-tone 800-1000 0.25 Increased urgency - Level crossing Tone 04 Alternate fast two-tone 2500-3100 0.25 Security deterrent Tone 05 Alternate two-tone 440-554 0.4/0.1 AFNOR, France Tone 06 Alternate two-tone 430-470 1.0 Tone 07 Alternate very fast two-tone 800-1000 0.13 Tone 08 Alternate very fast two-tone 2500-3200 0.07 Tone 09 Alternate two-tone 440-554 2.0 Turn out, Sweden Tone 10 Continuous note 700 All-clear, Sweden Tone 11 Continuous note 1000 Tone 12 Continuous note 1000 Tone 13 Continuous note 2300 Tone 14 Continuous note 440 Tone 15 Interrupted tone 1000 2.0 Tone 16 Interrupted tone 420 1.25 AS2220, Australia Tone 17 Interrupted tone 1000 0.5 Tone 18 Interrupted tone 2500 0.25 Tone 19 Interrupted tone 2500 0.5 Tone 20 Interrupted tone 700 6/12 Pre-vital message, Sweden Tone 21 Interrupted tone 1000 1.0 Tone 22 Interrupted tone 700 4.0 Air-raid alarm, Sweden Tone 23 Interrupted tone 700 0.25 Local warning, Sweden Tone 24 Interrupted tone 720 0.7/0.3 Industrial alarm, Germany Tone 25 Interrupted, fast, rising volume 1400 0.25 Tone 26 Fast siren 250-1200 0.085 Tone 27 Rising constant, fall 1000 10/40/10 Industrial alarm, Germany Tone 28 ISO 8201 Evacuation 800-1000 As standard International evacuation alarm Tone 29 Fast whoop 500-1000 0.15 Tone 30 Slow whoop 500-1200 4.5 Evacuation, The Netherlands Tone 31 Reverse sweep 1200-500 1.0 Evacuation, Germany Tone 32 Siren 500-1200 3.0 Accessories and Spare Parts Designation Description Art. no. PS Weight kg Replacement installation kit gasket, screws, nuts, locking devices and washers 212184 80 0.040 Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations X ø 147 50 [ø 5,81] ø 1 24 [ø 4,88] 65 [2,56] ø 10 5 [ø 4,13] 36 [1,42] 14850E00 X = 6 x holes dia 5.3 mm (0.2") and c'bored 10.2 mm (0.4") equispaced on a 124 mm (4.9") PCD 533

Flameproof Audible Signal 115 db(a) Series YA90 & Series YA90 WebCode YA90A 13912E00 > Max sound output 115 db(a) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light weight glass reinforced polyester (GRP) Ex enclosure > Sound selection via 5 way DIL switch > Adjustable stainless steel ratchet bracket providing positive setting > Enclosure finished in red high performance paint with ABS flare > Monitoring facility (DC voltages only) > Dual 20 mm gland entries as standard ATEX / IECEx NEC 500 Class I Class II Class III Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 For use in x x x x For use in x Technical Data Explosion protection Global (IECEx) Gas and dust Europe (ATEX) Gas and dust North America (culus & ULc listed) Gas and dust EAC (TR) Gas and dust Certifications and certificates Certificates YA90/B versions: YA90/C versions: YA90/B+C versions: YA90/B versions: YA90/C versions: YA90/B+C versions: YA90/B versions: YA90/C versions: YA90/B+C versions: YA90/B versions: YA90/C versions: YA90/B+C versions: YA90/B+C versions: YA90/B versions: YA90/C versions: TC RU C-DE.AA71.B.00033 YA90/B versions: YA90/C versions: IECEx BAS 08.0062X IECEx BAS 08.0061X EN 60079-0:2009, EN 60079-1:2007-04, EN 60079-31:2008 Ex d IIB T6 Ta -60... +60 ºC Gb Ex d IIC T6 Ta -60... +60 ºC Gb Ex tb IIIC T85ºC Ta -60... +60 ºC Db IP66 Baseefa 08 ATEX 0191 X Baseefa 08 ATEX 0189 X EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009 E II 2 G Ex d IIB T6 Ta -60... +60 ºC Gb E II 2 G Ex d IIC T6 Ta -60... +60 ºC Gb E II 2 D Ex tb IIIC T85ºC Ta -60... +60 ºC Db IP66 E161818 USL: UL 464 / ISA 12.12.01-2007 CNL: CAN/ULC-S525-07, Edition 3 2007 / A C22.2 No. 213 USL, CNL - Class I, Div. 2, Groups C and D Hazardous Locations Operating temperature -60... +66 ºC Audible signal appliance, fire alarm service private mode USL, CNL - Class I, Div. 2, Groups A, B, C and D Hazardous Locations Operating temperature -60... +66 ºC Audible signal appliance, fire alarm service private mode 1 Ex d IIB T6 (Tamb -60 C...+60 C ) Gb X Ex tb IIIC T85 C Db X 1 Ex d IIC T6 (Tamb -60 C...+60 C ) Gb X Ex tb IIIC T85 C Db X IECEx, ATEX, Brazil (INMETRO), China (China-Ex), India (PESO), Korea (KGs), Kazakhstan (TR), North America (culus, ULc), Russia (TR), Belarus (TR) 534

& Technical Data Electrical data Rated operational voltage Rated operational current 24 V DC, 48 V DC, 115 V AC and 230 V AC operational parameters + or -10 % 24 V DC 300 ma 48 V DC 160 ma 115 V AC 80 ma 230 V AC 45 ma Flameproof Audible Signal 115 db(a) Series YA90 UL calculate the current using RMS Root mean square which gives the following measurement and is the figure reported on UL variant product labels: Acoustic data Volume Alarm stages Sound selection Sound signal selection Ambient conditions Ambient temperature 24 V DC 500 ma 48 V DC not available UL certified variants 115 V AC 130 ma 230 V AC 90 ma 115 db(a) / 1 m Sound output for products gas groups IIC 2 stage alarm via DIL switch 32 (see table 7.2.6 Sound Tone Selection) All sounders have 32 sound signal selections. From the 32 sound signals, any signal may be chosen as the first stage alarm and any signal for the second stage alarm. Sound output level and current consumption depends upon the signal selected. ATEX/IECEx variants 24/48 V DC -60... +60 C 115 V AC -40... +60 C 230 V AC -40... +60 C culus & ULC listed -60... +66 C Max. relative humidity 95 % at 40 C Mechanical data Material Enclosure GRP Horn ABS Flame retardant Fixings Screws - A4-80 Bracket Stainless steel DIN EN 10088-9 1.4404 / AISI 316L Degree of protection IP66 BS EN 60529 NEMA 4X UL 50 Enclosure entries 2 x M20 cable entries equipped with 1 x stopping plug & 1 x dust cover UL Product variants supplied with 2 x M20 / 1/2 adaptors Mounting / Installation Assembly stainless steel mounting bracket provided, holes to suit M6, pitch 60 mm 535

Flameproof Audible Signal 115 db(a) Series YA90 & Selection Table Version Gasgruppe Rated operational voltage YA90 Sounder, ATEX & IECEx certification, standard devices YA90 Sounder, North America culus & ULc listed, standard devices YA90 Sounder, EAC certification, standard devices Note Order number Art. no. PS Weight kg IIC 24 V DC YA90/C-D-EN-RN-ST-00-00-00 205209 80 4.500 115 V AC YA90/C-L-EN-RN-ST-00-00-00 206770 80 4.500 230 V AC YA90/C-N-EN-RN-ST-00-00-00 205214 80 4.500 A, B, C & D 24 V DC YA90/C-D-UL-RN-ST-00-00-00 205365 80 4.500 115 V AC YA90/C-L-UL-RN-ST-00-00-00 205366 80 4.500 230 V AC YA90/C-N-UL-RN-ST-00-00-00 212397 80 4.500 IIC 24 V DC YA90/C-D-RU-RN-ST-00-00-00 206661 80 4.500 115 V AC YA90/C-L-RU-RN-ST-00-00-00 212399 80 4.500 230 V AC YA90/C-N-RU-RN-ST-00-00-00 205217 80 4.500 Variations in gas group, voltage and certification are available Tag labels can be added, please contact your local sales office for more details Type Code Variant Option Code YA90 /. -. -.. - RN - ST -.. -.. -.. Gas group ATEX / IECEx products culus listed products IIB C, D Groups B IIC A, B, C, D Groups C C Rated operational voltage 24 V DC D 48 V DC F 115 V AC L 230 V AC N Certification ATEX & IECEx EN culus & ULc listed UL EAC (TR) RU Body Colour Red RN Specification Standard ST Options None 00 Tag label TL Duty label DL Tag & Duty label DT Activation Standard 00 Telephone TI Local certification Standard 00 INMETRO IN PESO PE KCs KC CQST CQ 536

& Flameproof Audible Signal 115 db(a) Series YA90 Accessories and Spare Parts Designation Figure Description Order number Art. no. PS WebCode Cable glands Ex d & Ex e Compound barrier cable gland for all types of unarmoured and braid armour cables (nickel plated brass) CMP-20PXSS2K 109441 10 PXSS2KA 15793E00 15791E00 Ex d & Ex e Compound barrier cable gland for all types of armoured cables (SWA, braided, tape) (nickel plated brass) CMP-20PX2K 109428 10 PX2KA Note Approvals of cable entries have to be observed. Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 325 [12,80] ø210 [ø 8 27] 143,50 [5,65] 30 [1,18] ø 7 [ø 0,28] 181 ø 12,7 [ø 0,50] [ 7,13] 60 [2,36] 13971E00 537

Hazardous Area Loudspeaker - 25, 15 or 8 W Series 8494 & > Max. sound pressure level 121 db(a) > Extreme temperature range -50... +60 C > Degree of protection IP66 & IP67 > Antistatic polyamid enclosure > Stainless steel fixing > Ex e connection chamber > Spring clamp terminals > Corrosion resistant device Series 8494 17077E00 WebCode 8494A ATEX / IECEx NEC 505 NEC 506 Class I Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 For use in x x x x For use in x Selection Table Version Group Flare size Hazardous area loudspeaker - 25 Watt Series 8494, standard devices Watt options Impedance / Transformer Order number Art. no. PS Weight kg IIC short 25 W 8 Ω 8494/C-S-EN-ST-12-00 242300 80 2.200 20 Ω 8494/C-S-EN-ST-13-00 242301 80 2.200 25 W + 100 V 8494/C-S-EN-ST-14-00 242302 80 2.200 tappings line transformer long 25 W 8 Ω 8494/C-L-EN-ST-12-00 242310 80 2.800 20 Ω 8494/C-L-EN-ST-13-00 242311 80 2.800 25 W + tappings 100 V line transformer Order Number Supplement Hazardous area Variations Type code: please fill in fields loudspeaker Series 8494, Gas group acc. to specification IIB + H2 IIC Flare short long Certification ATEX / IECEx / NEC/CEC 505 Company specification standard B C S L EN ST Options 15 W 8 Ω 10 15 W 20 Ω 11 25 W 8 Ω 12 25 W 20 Ω 13 25 W 100 V line transformer 14 15 W 100 V line transformer 15 8 W 100 V line transformer 16 25 W 70 V line transformer 17 15 W 70 V line transformer 18 8 W 70 V line transformer 19 Local certification standard 00 8494/C-L-EN-ST-14-00 242312 80 2.800 Order Number 8494/ _ - _ - _ - _ - _ - _ 538

& Technical Data Explosion protection Global (IECEx) Gas and dust Europe (ATEX) Gas and dust North America (NEC, CEC) Gas and dust Certifications and certificates Certificates Electrical data Device version Line options Impedance Acoustic data Short flare version Hazardous Area Loudspeaker - 25, 15 or 8 W Series 8494 IIB + H2, IIC IECEx PRE 14.0058X IIB + H2 IIC IIB + H2, IIC IIB + H2 IIC IECEx, ATEX, Canada (clcus), USA (clcus) 100 or 70 V 8 or 20 Ω II 2 G Ex d e mb IIB+H2 T4 (-50 C ( Ta ( +60 C) Gb IP66/67 II 2 D Ex tb IIIC T105 C (-50 C ( Ta ( +60 C) Db IP66/67 II 2 G Ex d e mb IIC T4 (-50 C ( Ta ( +60 C) Gb IP66/67 II 2 D Ex tb IIIC T105 C (-50 C ( Ta ( +60 C) Db IP66/67 PRE 14 ATEX 5555X E II 2 G Ex d e mb IIB+H2 T4 (-50 C ( Ta ( +60 C) Gb IP66/67 E II 2 D Ex tb IIIC T105 C (-50 C ( Ta ( +60 C) Db IP66/67 E II 2 G Ex d e mb IIC T4 (-50 C ( Ta ( +60 C) Gb IP66/67 E II 2 D Ex tb IIIC T105 C (-50 C ( Ta ( +60 C) Db IP66/67 IIB + H2, IIC CAN/A-C22.2 No. 60079-0:2011 & UL 60079-0:2009, CAN/A-C22.2 No. 60079-1:2011 & UL 60079-1:2009, A-C22.2 No. 60065-03:2012 & UL 60065:2007 IIB + H2 IIC Class 1 Zone 1 AEx d IIB+H2 T4 Gb -50 C ( Ta ( +50 C, IP 66/IP67 Class 1 Zone 1 AEx d IIC T4 Gb -50 C ( Ta ( +50 C, IP 66/IP67 8494/.-S-..-..-..-.. IIB + H2 IIC Sound pressure level at 1 W 105 db(a) 1 W / 1m 102 db(a) 1 W / 1m Sound pressure level at 25 W 118 db(a) 1m 115 db(a) 1m Frequency range 330... 7000 Hz 450... 6000 Hz Dispersion (-6 db) 1 khz 200 105 4 khz 47 35 Directivity factor at 1 khz 1.8 1.8 Sound pressure level vs frequency at 1 W db 110 105 100 95 90 85 80 75 70 65 60 55 50 20 Hz 50 100 200 500 1K 2K 5K 10K 20K 16888E00 539

Hazardous Area Loudspeaker - 25, 15 or 8 W Series 8494 & Technical Data Acoustic data Long flare version 8494/.-L-..-..-..-.. IIB + H2 IIC Sound pressure level at 1 W 109 db(a) 1 W / 1m 106 db(a) 1 W / 1m Sound pressure level at 25 W 121 db(a) / 1m 118 db(a) / 1m Frequency range 330... 7000 Hz 450... 6000 Hz Dispersion (-6 db) 1 khz 81 73 4 khz 37 33 Directivity factor at 1 khz 4.5 4.5 Sound pressure level vs db frequency at 1 W 115 110 105 100 95 90 85 80 75 70 65 60 55 20 Hz 50 100 200 500 1K 2K 5K 10K 20K Ambient conditions Operating -50... +60 C temperature range Mechanical data Cable entries 2 x M20 supplied with 2 x dust cover Material Enclosure Anti static polyamid Flare Anti static polyamid Bracket Anti static polyamid supplied as standard Labels Polyester foil External fixings Stainless steel Degree of protection IP66 / IP67 acc. to IEC 60529 Mounting / Installation Mounting via bracket Connection 4 mm spring clamp terminals 50 pieces Accessories and Spare Parts Designation Figure Description Order number Art. no. PS Web- Code Cable gland 8161/7-M20-1304 8161/7-M20-239156 10 8161A 4... 13 mm 2 (delivery lot *) ) 1304 16887E00 02055E00 Stopping plug 04840E00 8290/3-M20 8290/3-M20 1 piece 100 pieces 8290/3-M20 143522 18 8290A 8290/3-M20 143543 18 8290A Bracket stainless steel 1 piece 01789E00 *) Purchase order quantity in [pieces], the delivery quantity is automatically rounded to the delivery lot. 540

& Hazardous Area Loudspeaker - 25, 15 or 8 W Series 8494 Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations A 170 [6,69] 188 [ 7,40 ] 30 [1,18] Ø 7 [ Ø 0,28] ø 10,5 [ø 0,41] 207 [8,15] X X 120 [4,72] 144,50 [5,69] A 144 [5,67] Hazardous Area Loudspeaker - Short Flare Series 8494 Bracket (A) supplied as standard 43 [1,69] 17003E00 A 170 [6,69] 275 [10,83] 30 [1,18] Ø 7 [ Ø 0,28] ø 10,5 [ø 0,41] 348 ±3 [13,70±0,12] X X 120 [4,72] 144,50 [5,69] A 200 [7,87] Hazardous Area Loudspeaker - Long Flare Series 8494 Bracket (A) supplied as standard 43 [1,69] 16814E00 541

Signal Horn 105 db(a) Series 8491/1, 8491/2 & > Fixed signal tone > Volume max. 105 db(a) / 1 m > Installation by means of angle mounting > AC and DC versions Signal Horn Series 8491/1 > With trumpet and connection cable Signal Horn Series 8491/2 Series 8491/1, 8491/2 10616E00 > Compact design with connection chamber and cable gland WebCode 8491A ATEX Zone 0 1 2 20 21 22 8491/1: For use in x x 8491/2: For use in x x x x Selection Table Version Rated operational voltage Order number Art. no. PS Weight 24 V AC, 50 Hz 8491/11-024 145276 17 1.450 42... 48 V AC, 50 Hz 8491/11-042 145278 17 1.450 115 V AC, 50 / 60 Hz 8491/11-115 145279 17 1.450 120 V AC, 60 Hz 230 V AC, 50 Hz 8491/11-230 145280 17 1.450 24 V DC 8491/15-024 145275 17 1.450 kg 00446E00 10614E00 230 V AC, 50 Hz 8491/21-230 145285 17 1.500 115 V AC, 50 / 60 Hz 8491/21-115 145284 17 1.500 120 V AC, 60 Hz 42... 48 V AC, 50 Hz 8491/21-042 145283 17 1.500 24 V AC, 50 Hz 8491/21-024 145282 17 1.500 24 V DC 8491/25-024 145281 17 1.500 542

& Signal Horn 105 db(a) Series 8491/1, 8491/2 Technical Data Explosion protection Europe (ATEX) Gas and dust Certifications and certificates Certificates 8491/1 8491/2 EN60079-0:2012 EN60079-18:2009 EN60079-0:2012 EN60079-7:2007 EN60079-18:2009 EN60079-31:2009 E II 2 G Ex e mb IIC T5 Gb E II 2 G Ex mb IIC T5 Gb - - E II 2 D Ex tb IIIC T70 C Db IP65 ATEX, China (China-Ex), Kazakhstan (TR), Russia (TR), Serbia (SRPS), Ukraine (TR), Belarus (TR) ATEX, China (China-Ex), Kazakhstan (TR), Russia (TR), Serbia (SRPS), Ukraine (TR), Belarus (TR) Material Enclosure PC/ABS, black PC/ABS, black Degree of protection IP55 IP65 Connection type LAPPTHERM 145, 2 x 0.75 mm 2, 3 m screw terminal in the connection chamber max. connection cross-section 2.5 mm 2 1 x M16 cable gland 6.5... 9.5 mm cable dia. range Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Signal horn with trumpet Series 8491/1 03540E00 Signal horn, compact design with connection chamber Series 8491/2 10617E00 543

GRP Flameproof Visual Signal 5 Joule Series FX15 & Series FX15 15567E00 > Suitable for offshore / onshore & harsh environments > Corrosion resistant light-weight enclosure made of glass-fibre reinforced polyester (GRP) > Stainless steel and fixings and guard > High ingress protection IP66 & IP67 > Extreme temperature range -55... +70 C > Flexible mounting options > Light enhancing lens design WebCode FX15A ATEX IECEx Zone 0 1 2 20 21 22 For use in x x x x Selection Table Version Group Rated operational voltage ATEX & IECEx standard variants Note Lens colour Order number Art. no. PS Weight kg IIC 24 V DC amber FX15/C-D-050-A-EN-SF-A 217979 80 2.230 blue FX15/C-D-050-B-EN-SF-A 217992 80 2.230 clear FX15/C-D-050-C-EN-SF-A 217989 80 2.230 green FX15/C-D-050-G-EN-SF-A 217997 80 2.230 magenta FX15/C-D-050-M-EN-SF-A 217998 80 2.230 opal FX15/C-D-050-O-EN-SF-A 217990 80 2.230 red FX15/C-D-050-R-EN-SF-A 217971 80 2.230 yellow FX15/C-D-050-Y-EN-SF-A 217991 80 2.230 48 V DC amber FX15/C-F-050-A-EN-SF-A 217980 80 2.230 blue FX15/C-F-050-B-EN-SF-A 217976 80 2.230 clear FX15/C-F-050-C-EN-SF-A 217999 80 2.230 green FX15/C-F-050-G-EN-SF-A 217977 80 2.230 magenta FX15/C-F-050-M-EN-SF-A 217978 80 2.230 opal FX15/C-F-050-O-EN-SF-A 218000 80 2.230 red FX15/C-F-050-R-EN-SF-A 217972 80 2.230 yellow FX15/C-F-050-Y-EN-SF-A 217975 80 2.230 115 V AC amber FX15/C-L-050-A-EN-SF-A 217981 80 2.250 blue FX15/C-L-050-B-EN-SF-A 217986 80 2.250 clear FX15/C-L-050-C-EN-SF-A 217983 80 2.250 green FX15/C-L-050-G-EN-SF-A 217993 80 2.250 magenta FX15/C-L-050-M-EN-SF-A 217994 80 2.250 opal FX15/C-L-050-O-EN-SF-A 217984 80 2.250 red FX15/C-L-050-R-EN-SF-A 217973 80 2.250 yellow FX15/C-L-050-Y-EN-SF-A 217985 80 2.250 230 V AC amber FX15/C-N-050-A-EN-SF-A 217982 80 2.250 blue FX15/C-N-050-B-EN-SF-A 218002 80 2.250 clear FX15/C-N-050-C-EN-SF-A 217995 80 2.250 green FX15/C-N-050-G-EN-SF-A 218003 80 2.250 magenta FX15/C-N-050-M-EN-SF-A 218004 80 2.250 opal FX15/C-N-050-O-EN-SF-A 217996 80 2.250 red FX15/C-N-050-R-EN-SF-A 217974 80 2.250 yellow FX15/C-N-050-Y-EN-SF-A 218001 80 2.250 FX15 Beacons are supplied without a bracket. These must be ordered separately (see accessories table). 544

& GRP Flameproof Visual Signal 5 Joule Series FX15 Technical Data Explosion protection Global (IECEx) Gas and dust Europe (ATEX) Gas and dust Product variant table Certifications and certificates Certificates IIB IECEx BAS 13.0005X IIC IECEx BAS 13.0003 IIB, IIC IEC 60079-0: 2011 / IEC 60079-1: 2007-04 / IEC 60079-31: 2008 IIB Ex d IIB T* Gb (Ta = -60 +** C) Ex tb IIIC T*** C Db IP 66 (Ta = -60 +** C) IIC Ex d IIC T* Gb (Ta = -60 +** C) Ex tb IIIC T*** C Db IP 66 (Ta = -60 +** C) * temperature class on the table IIB Baseefa13ATEX0007X IIC Baseefa13ATEX0006 IIB, IIC EN 60079-0: 2012 / EN 60079-1: 2007 / EN 60079-31: 2009 IIB EII 2 G Ex d IIB T* Gb (Ta = -60 +** C) EII 2 D Ex tb IIIC T*** C Db IP 66 (Ta = -60 +** C) IIC EII 2 G Ex d IIC T* Gb (Ta = -60 +** C) EII 2 D Ex tb IIIC T*** C Db IP 66 (Ta = -60 +** C) * temperature class on the table Power and voltage 5 J 24 V DC 5 J 48 V DC 5 J 115 V AC 5 J 230 V AC IECEx, ATEX, Brazil (INMETRO), India (PESO), Kazakhstan (TR), Russia (TR), Belarus (TR) Electrical data Rated operational voltage 24 V DC, 48 V DC, 115 V AC and 230 V AC operational parameters +/-10 % Rated operational current 24 V DC 300 ma 48 V DC 185 ma 115 V AC 140 ma 230 V AC 75 ma Luminous characteristics Effective candela Candela seconds Clear lens 9.96 cds 49 cd Flash energy 5 J Flash rate 1 per second Operating temperature range 24 & 48 V DC -50... +70 C 115 V AC -55... +55 C 230 V AC -55... +70 C Mechanical data Material Enclosure GRP Lens cover polycarbonate Wire guard stainless steel Degree of protection IP66 & IP67 IEC 60529 Cable entries 3 x M20, product supplied with 3 x dust cover Weight 2.4 kg Temperature class Max. surface temperature Ambient temperature range T6 T73 C -60 +40 C T5 T88 C -60 +55 C T4 T103 C -60 +70 C T6 T73 C -60 +40 C T5 T88 C -60 +55 C T4 T103 C -60 +70 C T5 T83 C -60 +40 C T4 T113 C -60 +55 C T6 T75 C -60 +40 C T5 T90 C -60 +55 C T4 T105 C -60 +70 C 545

GRP Flameproof Visual Signal 5 Joule Series FX15 & Accessories and Spare Parts Designation Figure Description Art. no. PS WebCode Mounting brackets Stainless steel L-bracket - see dimensional drawings 221711 80 Cable glands 15795E00 15794E00 Stainless steel backstrap mounting bracket - see dimensional drawings Ex d & Ex e Compound barrier cable gland for all types of unarmoured and braid armour cables (nickel plated brass) 221712 80 109441 10 PXSS2KA 15793E00 Ex d & Ex e Compound barrier cable gland for all types of armoured cables (SWA, braided, tape) (nickel plated brass) 109428 10 PX2KA Xenon tube 15791E00 Replacement xenon tube assembly 223636 80 PCB PCB termination 15798E00 15786E00 PCB assembly 24 V DC 5J 223635 80 PCB assembly 48 V DC 5J 223634 80 PCB assembly 110 V AC 5J 223632 80 PCB assembly 230 V AC 5J 223580 80 PCB assembly termination 223579 80 Flange 15785E00 Flange assembly standard clear 223578 80 15796E00 546

& GRP Flameproof Visual Signal 5 Joule Series FX15 Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations 148 mm / 5.83 " 105 mm / 4.13 " 78 mm / 3.07 " 87 mm / 3.43 " 164 mm / 6.4 6 " 78 mm / 3.07 " 152 mm / 5.98 " ø 8,50 mm / ø 0.33 " 239 mm / 9.41 " 245 mm / 9.65 " 265 mm / 10.43 " 253 mm / 9.96 " 137 mm / 5.39 " 15739E00 15738E00 15737E00 FX15 Beacon FX15 Beacon with L bracket FX15 Beacon with backstrap bracket 78 mm / 3.07 " ø 8,50 mm ø 0.33 " 75 mm / 2.95 " ø9 mm ø0.35 " 180 mm / 7.09 " 152 mm / 5.98 " 25 mm 0.98 " 180 mm / 7.09 " 28 mm 1.10 " 15743E00 15763E00 Backstrap bracket 20 mm 0.79 " 75 mm / 2.95 " 87 mm / 3.43 " 105 mm / 4.13 " ø9 mm ø0.35 " 15742E00 15762E00 L-shaped bracket 547

Flashing Beacon and Continuous Beacon Series 6161 & > Robust, seawater resistant aluminium enclosure > Flashing frequency 1 Hz > Flashing energy 5 Joules > Integrated Ex e connection chamber > Available with signal yellow, red, orange, green, blue and clear light dome > Steady beacon in LED technology > Extreme temperature range -40... +50 C Series 6161 01817E00 WebCode 6161A ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x Selection Table Version Nominal voltage Internal fuse Order number Art. no. PS Weight 6161/2 Flashing Beacon 6161/3 Continuous Beacon 230 V AC, 50... 60 Hz 110... 127 V AC, 50... 60 Hz 24... 42 V AC, 50... 60 Hz and 12... 48 V DC kg 315 mat 6161/2-11-.21-0 120614 34 1.500 315 mat 6161/2-31-.21-0 120624 34 1.500 6161/2-61-.21-0 120633 34 1.500 60... 80 V DC 6161/2-41-.21-0 120641 34 1.500 230 V AC, 50... 60 Hz 24 V AC / DC, 0 Hz, 50... 60 Hz 200 mat 6161/3-10-.21-0 120686 34 1.400 315 mat 6161/3-70-.21-0 120693 34 1.400 Order Number Supplement Colour of glass signal yellow 6161/.-..-1.. clear 6161/.-..-2.. red 6161/.-..-3.. blue 6161/.-..-4.. green 6161/.-..-5.. orange 6161/.-..-6.. Note The optical beacons are supplied without attachment materials and wire guard. These must be ordered separately! 548

& Flashing Beacon and Continuous Beacon Series 6161 Technical Data Version 6161/2 Flashing Beacon 6161/3 Continuous Beacon Explosion protection Global (IECEx) Gas and dust IECEx LCI 08.0032X IECEx LCI 08.0032X Ex d e IIC T* Gb -40 C T amb +** C Ex d e IIC T* Gb -40 C T amb +** C Ex tb IIIC T* Db IP66-40 C T amb +** C Ex tb IIIC T* Db IP66-40 C T amb +** C IEC 60079-0 : 2011 IEC 60079-1 : 2007-04 IEC 60079-7 : 2006-07 IEC 60079-31 : 2008 ** see ambient conditions for the temperature class IEC 60079-0 : 2011 IEC 60079-1 : 2007-04 IEC 60079-7 : 2006-07 IEC 60079-31 : 2008 ** see ambient conditions for the temperature class Europe (ATEX) Gas and dust LCIE 02 ATEX 6062 X LCIE 02 ATEX 6062 X E II 2 G Ex d e IIC T* Gb -40 C T amb +** C E II 2 G Ex d e IIC T* Gb -40 C T amb +** C E II 2 D Ex tb IIIC T* Db IP66-40 C T amb +** C E II 2 D Ex tb IIIC T* Db IP66-40 C T amb +** C EN 60079-0 : 2012 EN 60079-1 : 2007 EN 60079-7 : 2007 EN 60079-31 : 2009 Conditions of certificate: If wire guard is not installed, the apparatus shall be submitted to low mechanical impact only. EN 60079-0 : 2012 EN 60079-1 : 2007 EN 60079-7 : 2007 EN 60079-31 : 2009 Conditions of certificate: If wire guard is not installed, the apparatus shall be submitted to low mechanical impact only. ** see ambient conditions for the temperature class ** see ambient conditions for the temperature class Certifications and certificates Certificates IECEx, ATEX, China (China-Ex) IECEx, ATEX, China (China-Ex) Ship approval GL Back-up fuse Rated values 4 AT (Fuse slow-blow or automatic circuit breaker C characteristic) 24... 42 V AC 50... 60 Hz 0.5... 0.3 A 110... 127 V AC 50... 60 Hz 0.11 A 230 V AC 50... 60 Hz 0.08 A 12... 48 V DC 0.5... 0.3 A 60... 80 V DC 0.13... 0.11 A Flashing energy 5 Joules Flashing frequency 1Hz Ambient temperature ** Temperature Class ** Temperature Class Type T amb Gas Dust 6121/2 +40 C T6 T85 C +50 C T5 T100 C 4 AT (Fuse slow-blow or automatic circuit breaker C characteristic) 24 V AC / DC 0 Hz, 50... 60 Hz 0.12 A 230 V AC 50... 60 Hz 0.02 A Type T amb Gas Dust 6121/3 +40 C T6 T65 C +50 C T6 T75 C Degree of protection IP66 according to IEC/EN 60529 Protection class I (internal and external PE connection terminal according to IEC/EN 60598) Material Enclosure aluminium alloy copper-free, yellow/black powder-coated Light dome polycarbonate, prismatic Special lock Ex d enclosure; M4 hexagon socket stud Cable entries 1 x M20 x 1.5 stopping plug 1 x M20 x 1.5 cable gland metal cable gland on request Connection type screw terminal block, 3-pole 549

Flashing Beacon and Continuous Beacon Series 6161 & Accessories and Spare Parts Designation Figure Description Art. no. PS Weight Mounting plate Pipe clamp 04279E00 material: stainless steel, includes mounting screws, for wall or floor mounting material: stainless steel includes mounting screws R 1 1 / 4 kg 120821 34 0.158 120812 34 0.500 09349E00 R 1 1 / 2 R 2 120819 34 0.470 120823 34 0.500 Ceiling or wall-mounting bracket material: stainless steel includes mounting screws 120826 34 0.480 09350E00 Wire guard material: stainless steel 120818 34 0.260 09351E00 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Optical beacon 6161 Mounting accessories 09345E00 106,25 7 25 7 25 50 130 04716E00 09346E00 04595E00 Ceiling and wall-mounting bracket Pipe clamp Mounting plate 550

& Signal Beacon - LED Series 6162 Series 6162 WebCode 6162A 06147E00 > Versions rotating mirror beacon rotating beacon beacon with double flash (9+5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seewater resistant aluminium enclosure with glass dome > Integrated Ex e connection chamber > Glass dome available in: signal yellow, red, orange and blue respectively clear > Available with 20 W / 35 W halogen bulb or as LED-continuous beacon / LED-rotating beacon ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x Technical Data Explosion protection Global (IECEx) Gas and dust IECEx PTB 06.0078 Ex d e llc T3... T6 Gb* Ex tb lllc T80 C... T160 C Db* Europe (ATEX) Gas and dust PTB 06 ATEX 1037 E ll 2 G Ex d e llc T3... T6 Gb* Certifications and certificates Certificates Rated operational voltage Lamp wattage Rotation speed E ll 2 D Ex tb lllc T80 C... T160 C Db* * Temperature classes are dependent on lamp wattage (see selection table) IECEx, ATEX, Kazakhstan (TR), Russia (TR), Serbia (SRPS), Ukraine (TR), Belarus (TR) see selection table see selection table rotating mirror beacon: 180 rpm rotating beacon: 60 rpm Ambient temperature see selection table Degree of protection IP66 Protection class I (acc. to IEC/EN 60598) Material Enclosure aluminium powder coated, seawater resistant Light dome glass, resistant to thermal shocks Cable entries 1 x M20 x 1.5 (d 4... 13 mm) 1 x M20 x 1.5 stopping plug metal cable gland on request Connection cross-section L1, N, PE 2.5 mm 2 finely-stranded 4 mm 2 solid 551

Signal Beacon - LED Series 6162 & Selection Table Version Rated operational voltage Lamp wattage Temperature class Max. surface temperature Max. ambient temperature Order number Art. no. PS Weight 06128E00 Rotating mirror beacon Rotating beacon 05759E00 24 V AC / DC, 50... 60 Hz 115 V AC, 50... 60 Hz 230 V AC, 50... 60 Hz 24 V AC / DC, 50... 60 Hz 115 V AC, 50... 60 Hz 230 V AC, 50... 60 Hz 20 W T4 T4 35 W T3 T3 35 W T3 T3 20 W T4 T4 35 W T3 T3 20 W T6 T5 35 W T4 T4 35 W T4 T4 20 W T6 T5 35 W T4 T4 24 V DC 9 + 5 J T5 T5 115 V AC, 50... 60 Hz 230 V AC, 50... 60 Hz 9 + 5 J T5 T4 9 + 5 J T5 T5 105 C 115 C 150 C 160 C 150 C 160 C 105 C 115 C 150 C 160 C 80 C 90 C 105 C 115 C 105 C 115 C 80 C 90 C 105 C 115 C 85 C 95 C 90 C 100 C 85 C 95 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C 40 C 50 C kg 6162/17-61-.11 120872 34 5.600 6162/17-62-.11 120863 34 5.600 6162/17-32-.11 120866 34 5.600 6162/17-11-.11 120871 34 5.600 6162/17-12-.11 120869 34 5.600 6162/18-61-.11 120874 34 5.600 6162/18-62-.11 120864 34 5.600 6162/18-32-.11 120867 34 5.600 6162/18-11-.11 120873 34 5.600 6162/18-12-.11 120870 34 5.600 6162/16-53-.11 120861 34 5.600 6162/16-23-.11 120865 34 5.600 6162/16-13-.11 120868 34 5.600 05759E00 Beacon with double flash 24 V AC / DC (± 15 %), 50... 60 Hz 110... 127 V AC, 50... 60 Hz 230... 240 V AC, 50... 60 Hz 15 J T6 T6 15 J T5 T4 15 J T6 T6 75 C 75 C 95 C 105 C 80 C 80 C 40 C 50 C 40 C 50 C 40 C 50 C 6162/15-64-.11 120877 34 5.600 6162/15-44-.11 120875 34 5.600 6162/15-74-.11 120876 34 5.600 05759E00 Flashing beacon Order Number Supplement Colour of glass signal yellow 6162/..-..-1.. clear 6162/..-..-2.. red 6162/..-..-3.. blue 6162/..-..-4.. orange 6162/..-..-6.. Note The optical beacons are supplied without mounting accessories and wire guard. These must be ordered separately! 552

& Signal Beacon - LED Series 6162 Selection Table Version Colour of glass Rated operational voltage Lamp wattage Temperature class Max. surface temperature Max. ambient temperature Order number Art. no. PS Weight signal yellow 24 V DC 5 W T6 T6 T5 115... 230 V AC, 50... 60 Hz 5 W T6 T6 T5 70 C 80 C 90 C 70 C 80 C 90 C 40 C 50 C 60 C 40 C 50 C 60 C kg 6162/19-55-111 201879 34 5.300 6162/19-95-111 201901 34 5.300 12628E00 LED-continuous beacon 12629E00 LED-continuous beacon red 24 V DC 5 W T6 T6 T5 115... 230 V AC, 50... 60 Hz 5 W T6 T6 T5 orange 24 V DC 5 W T6 T6 T5 115... 230 V AC, 50... 60 Hz 5 W T6 T6 T5 70 C 80 C 90 C 70 C 80 C 90 C 70 C 80 C 90 C 70 C 80 C 90 C 40 C 50 C 60 C 40 C 50 C 60 C 40 C 50 C 60 C 40 C 50 C 60 C 6162/19-55-311 201880 34 5.300 6162/19-95-311 219980 34 5.300 6162/19-55-611 203036 34 5.300 6162/19-95-611 203037 34 5.300 12696E00 LED-continuous beacon signal yellow 24 V DC 3.6 W T6 T6 T5 115... 230 V AC, 50... 60 Hz 3.6 W T6 T6 T5 70 C 80 C 90 C 70 C 80 C 90 C 40 C 50 C 60 C 40 C 50 C 60 C 6162/18-55-111 219972 34 5.300 6162/18-95-111 201903 34 5.300 12628E00 LEDrotating beacon red 24 V DC 3.6 W T6 T6 T5 115... 230 V AC, 50... 60 Hz 3.6 W T6 T6 T5 70 C 80 C 90 C 70 C 80 C 90 C 40 C 50 C 60 C 40 C 50 C 60 C 6162/18-55-311 219959 34 5.300 6162/18-95-311 201904 34 5.300 12629E00 LEDrotating beacon 12696E00 LEDrotating beacon Note orange 24 V DC 3.6 W T6 T6 T5 115... 230 V AC, 50... 60 Hz 3.6 W T6 T6 T5 70 C 80 C 90 C 70 C 80 C 90 C 40 C 50 C 60 C 40 C 50 C 60 C The optical beacons are supplied without mounting accessories and wire guard. These must be ordered separately! 6162/18-55-611 203034 34 5.300 6162/18-95-611 203035 34 5.300 553

Signal Beacon - LED Series 6162 & Accessories and Spare Parts Designation Figure Description Art. no. PS Weight kg Halogen lamp G6.35 20 W / 12 V 2 pc 120933 37 0.001 20 W / 24 V 2 pc 120934 37 0.001 05003E00 35 W / 12 V 2 pc 120935 37 0.001 35 W / 24 V 2 pc 120936 37 0.001 Mounting plate Pipe clamp 04279E00 material: stainless steel, includes mounting screws, for wall or floor mounting R 1 1 / 4 R 1 1 / 2 R 2 120821 34 0.158 120919 34 0.520 120920 34 0.560 120921 34 0.600 Mounting bracket 04223E00 material: stainless steel, includes mounting screws 120930 34 0.450 Wire guard 04281E00 material: stainless steel, includes mounting screws 120917 34 0.540 10289E00 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 336 X 32 316 95 76,50 32 32 15,50 M6 Ø 210 Ø 210 12 32 X 04282E00 Signal beacon Series 6162 Mounting accessories Y Y 139 58 50 7 106,25 7 25 1¼" (Ø 42) 1½" (Ø 48) 2" (Ø 60) 1¼" - 184 1½" - 191 2" - 203 40 25 106,25 7 7 25 50 130 130 04333E00 04335E00 04595E00 Mounting bracket Pipe clamp Mounting plate 554

& Instrinsically Safe LED Visual Flashing or Status Signal Series FD40IS, SD40IS > 8 LED array flashing or status beacon > High light intensity > Long life LED design > Lens available in six different colours > Flame retardant ABS enclosure > Up to 4 modules in any combination of colours Series FD40IS, SD40IS 13913E00 WebCode FD_SD40ISA ATEX Zone 0 1 2 20 21 22 For use in x x x x x x Selection Table Version Base colour Rated operational voltage Instrinsically Safe LED Visual Flashing Signal FD40IS signal, ATEX certification, standard single module devices Instrinsically Safe LED Visual Status Signal SD40IS signal, ATEX certification, standard single module devices Note red normal (RN) red normal (RN) Lens colour Order number Art. no. PS Weight kg 16.2... 26.4 V amber FD40IS/X/A/RN 207067 81 0.150 red FD40IS/X/R/RN 205111 81 0.150 green FD40IS/X/G/RN 212407 81 0.150 opal FD40IS/X/O/RN 212408 81 0.150 blue FD40IS/X/B/RN 212409 81 0.150 clear FD40IS/X/C/RN 212410 81 0.150 16.2... 26.4 V amber SD40IS/X/A/RN 212403 81 0.150 red SD40IS/X/R/RN 205460 81 0.150 green SD40IS/X/G/RN 209638 81 0.150 opal SD40IS/X/O/RN 212404 81 0.150 blue SD40IS/X/B/RN 212405 81 0.150 clear SD40IS/X/C/RN 212406 81 0.150 Multiple module units are available. Contact your local sales office for details. example module combinations base colour 14004E00 14005E00 14006E00 14007E00 Single device Double device Triple device Quadruple device red normal (RN) 555

Instrinsically Safe LED Visual Flashing or Status Signal Series FD40IS, SD40IS & Technical Data Explosion protection Europe (ATEX) Gas and dust Certifications and certificates Certificates Electrical data Rated operational voltage Current consumption Certified input parameters Baseefa05ATEX0075 E II 1G Ex ia IIC T4 Ga E II 1D Ex ia IIIC T190 C Da ATEX, India (PESO) 16.2... 26.4 V Power supply Certified barrier / Current consumption isolator parameters 24 V DC 28 V / 300 Ω 22 ma 18 V DC *) 28 V / 300 Ω 14 ma *) Light output reduced U i = 30 V I i = 200 ma P i = 0.7 W C i = 0 L i = 0 Line monitoring yes Luminous characteristics Light source 8 array LED Flash rate 1/s (FD40IS only) Lens colour amber, red, green, opal, blue, clear Ambient conditions Operating -25... +40 C temperature range Storage temperature -40... +70 C Max. relative humidity 90 % at 40 C Mechanical data Cable entries 1 x M20 Material Enclosure ABS, flame retardant Lens polycarbonate, flame retardant Assembly parts stainless steel fixings Labels polyester foil, adhesive Degree of protection IP65 acc. to IEC 60529 Mounting / Installation Mounting All units are supplied separately from the base for ease of installation. The base should be mounted to a reasonably flat surface or bulkhead. A gasket is supplied, should the surface be uneven, or if the unit is to be used in wet conditions. The installation is completed by fitting the beacon onto the base by means of the supplied screws. Connection Each beacon should be wired independently. 2.5 mm 2 terminals 556

& Instrinsically Safe LED Visual Flashing or Status Signal Series FD40IS, SD40IS Accessories and Spare Parts Designation Figure Description Order number Art. no. PS WebCode Safety barrier single channel 9001/01-280- 085-101 158351 20 9001A dual channel 9002/11-280- 186-001 158848 20 9002A 02326E00 Galvanic isolator single channel 9176/10-15-00s 160472 21 9176A dual channel 9176/20-15-00s 165567 21 9176A Cabel gland 12530E00 8161/8-M20-1304 50 pieces 4... 13 mm 2 (delivery lot *) ) 8161/8-M20-1304 239164 10 8161A 13027E00 *) Purchase order quantity in [pieces], the delivery quantity is automatically rounded to the delivery lot. Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 60,40 [2,38] 30,20 81,50 [3,21] 91,50 [3,60] 91,50 [3,60] A 1 x M20 A 1 x M20 5 [0,20] A ø 50,80 [ø 2,0 0] 1 x M20 [1,19] 45 A = knockout hole B 4 x M5 30,20 [1,19] 60,40 [2,38] C 4 x M5 16547E00 B = drill hole C = knockout hole A 2 x M20 13984E 557

LED Obstruction Light Low Intensity Series TEF 2430 > Complies with: ICAO annex 14 vol. 1 CH. 6, low intensity type B > Integrated terminal box > Low maintenance > Rugged construction > Low power consumption > Resistant to vibrations > Very long operating life Series TEF 2430 08470E00 WebCode T2430B ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x Selection Table Version Light intensity Voltage Order number Art. no. PS Luminaire Red LED 32 cd. 220... 254 V AC TEF2430160 170631 70 Omni-directional 110... 120 V AC TEF2430161 170632 70 24 V AC / DC TEF2430162 170633 70 Technical Data Explosion protection Global (IECEx) Gas IECEx DNV 13.0016X Ex d e op is IIB T5 Gb Europe (ATEX) Gas NEMKO 03 ATEX 064 E II 2 G Ex d e op is IIB T5 Gb Certifications and certificates Certificates IECEx, ATEX, Canada (A), USA Rated voltage 220 / 254 V AC 50 / 60 Hz 110 / 120 V AC 50 / 60 Hz 24 V AC / DC Power consumption max. 10.5 W Service life min. 50,000 working hours Light intensity > 32 cd. according to ICAO annex 14 vol. I Ch. 6 low intensity type B Luminous intensity distribution 80 90 80 70 70 60 60 60 10 0 20 30 40 50 50 40 30 20 10 50 40 30 20 10 0-10 -10 Ambient temperature -30... +50 C Cable glands 4 x M25 cable gland delivered with: 2 x M25 stopping plugs 2 x M25 cable glands -20-20 08472E00 558

LED Obstruction Light Low Intensity Series TEF 2430 Accessories and Spare Parts Designation Description Order number Art. no. PS Globe globe with guard, LED s and LED driver TEF4545 170634 70 Mounting plate complete with transformer 110... 254 V AC TEF4236 170635 70 O-Ring for globe / guard ring TEF50008009 170679 70 Cable gland cable gland, M25 TEF9147200 165825 70 Stopping plug drain plug EEx e M25 TEF7302101 169899 70 stopping plug EEx e, M25 TEF7947304 165845 70 Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 226 [8,90] 175 [6,89] 304 [11,97] 08471E00 559

Signal Beacon Series TEF 2430 > Rugged and low profile > Easy to install and maintain > Degree of protection IP66 / IP67 > Long lamp life due to compact fluorescent tube > Wide range of coloured globes > Short ignition time at low temperatures > Resistant to vibration Series TEF 2430 08470E00 WebCode T2430C ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x Selection Table Version Voltage Lamps Colour Order number Art. no. PS Luminaire 230 V 2 x 7 W clear TEF2430000 170654 70 green TEF2430100 170655 70 red TEF2430200 170656 70 yellow TEF2430301 170657 70 120 V 1 x 13 W clear TEF2430005 170658 70 green TEF2430105 170659 70 red TEF2430205 170660 70 yellow TEF2430306 170661 70 24 V DC 1 x 10 W clear TEF2430232 170664 70 Technical Data Explosion protection Global (IECEx) Gas IECEx DNV 13.0016X Ex d e IIB T5 Gb Europe (ATEX) Gas NEMKO 03 ATEX 064 E II 2 G Ex d e IIB T5 Gb Certifications and certificates Certificates IECEx, ATEX, Canada (A), USA Light intensity > 10 candela red > 70 candela yellow > 80 candela white Ambient temperature -30... +40 C Degree of protection IP66 / IP67 Material cast copper alloy globe: polycarbonate lexan Cable glands 4 x M25 stopping gland 1 x M25 cable glands green TEF2430233 170665 70 red TEF2430230 170662 70 yellow TEF2430231 170663 70 blue TEF2430234 170666 70 amber TEF2430235 170667 70 560

Signal Beacon Series TEF 2430 Accessories and Spare Parts Designation Description Order number Art. no. PS Fluorescent tube 7 W TEF9400032 165826 70 PLC 13 W 120 V TEF9400064 165848 70 PLC 10 W / 827 G24, 24 V TEF9400071 170668 70 Light fitting insert 230 V, complete TEF1671 170669 70 120 V AC, complete TEF3059 170670 70 24 V DC, complete TEF3191 170671 70 Lamp holder G23 TEF50880031 170672 70 Globe clear TEF1223 170673 70 green TEF1224 170674 70 red TEF1225 170675 70 yellow TEF1226 170676 70 blue TEF1227 170677 70 yellow amber TEF2036 170678 70 O-Ring for globe / guard ring TEF50008009 170679 70 Cable gland cable gland, M25 TEF9147200 165825 70 Reactor fluor. tube 2 x 7 W, 230 V / 240 V 50 / 60 Hz TEF50860035 165823 70 fluor. tube 2 x 7 W, 230 V / 240 V 50 / 60 Hz TEF50860031 170680 70 Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 226 [8,90] 175 [6,89] 304 [11,97] 08471E00 561

Signal Beacon - Zone 2 Series TEF 2440 Series TEF 2440 WebCode T2440A 06432E00 > Application deck lighting signal lighting obstacle marking > Rugged construction > Easy to install and maintain > Degree of protection IP66 / IP67 > Long lamp life due to compact fluorescent tube > Versatility offering variable mounting positions > Optional internal lamp reflector > Wide range of coloured globes available > Short ignition time at low temperatures > Resistant to vibrations ATEX Zone 0 1 2 20 21 22 For use in x Selection Table Version Lamps Rated voltage Colour of glass Order number Art. no. PS Weight kg Signal light Series TEF 2440 Technical Data Explosion protection Europe (ATEX) Gas 1 x 13 W 230 V AC clear TEF2440000 165849 70 1.900 green TEF2440001 165850 70 1.900 red TEF2440002 165851 70 1.900 amber TEF2440003 165836 70 1.900 blue TEF2440004 165837 70 1.900 yellow TEF2440103 165854 70 1.900 120 V AC clear TEF2440017 165853 70 1.900 red TEF2440016 165852 70 1.900 amber TEF2440015 165838 70 1.900 blue TEF2440018 165839 70 1.900 NEMKO 03ATEX3336 E II 3 G EEx na II T3/T4 Certifications and certificates Certificates ATEX Rated voltage 230 V AC 50/60 Hz 120 V AC 60 Hz Power consumption 18 W Lamp version PL-C compact fluorescent tube, max. 13 W Lamp holder G 24 D / 1 Light intensity > 10 cd red > 80 cd yellow > 90 cd white Ambient temperature -25... +45 C Degree of protection IP66 / IP67 Material Enclosure acid proof stainless steel, powder coated (RAL 9002) Globe polycarbonate Colour of glass white, yellow, red, blue, green and amber Cable entries 1 x cable gland M25 1 x stopping plug M25 562

Signal Beacon - Zone 2 Series TEF 2440 Accessories and Spare Parts Designation Description Order number Art. no. PS Weight kg Globe clear, spare part kit TEF2548 165855 70 0.180 green, spare part kit TEF2592 165857 70 0.180 red, spare part kit TEF2553 165856 70 0.180 yellow amber, spare part kit TEF2593 165842 70 0.180 blue, spare part kit TEF2604 165858 70 0.180 Ballast ballast and lamp holder, spare part kit TEF2510 165840 70 3.980 Fluorescent lamps PLC 13 W / 84 230 V TEF9400060 165846 70 0.060 PLC 10 W / 84 230 V TEF9400062 165847 70 0.060 PLC 13 W 120 V TEF9400064 165848 70 0.060 Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 163,30 [6,43] 146,30 [5,76] 120 [4,72] 4 x ø 6,50 [ 4 x ø 0,26] 100 [3,94] 140 [5,51] 78,50 [3,09] 205 [8,07] 06430E00 563

Obstruction Light LED Series TEF 2460 Series TEF 2460 16772E00 > Complies with: ICAO Annex 14 Vol. 1 Ch. 6, Low intensity type A or B > Integrated terminal box with drain plug/breather > Low maintenance > Rugged construction > Encapsulated electronics. No risk of water intrusion to LED s and electronics > Instant light > Resistant to vibrations WebCode T2460A ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x Selection Table Version Lamps Light intensity Voltage Order number Art. no. PS Obstruction Light LED red LED 10 cd 24 V DC ±30 % TEF2460166 240990 70 Series TEF 2460 100... 254 V AC TEF2460165 240989 70 32 cd 24 V DC ±30 % TEF2460162 240988 70 100... 254 V AC TEF2460160 241027 70 red + IR 10 cd 24 V DC ±30 % TEF2460168 241032 70 version is NVG compatible 32 cd 24 V DC ±30 % TEF2460167 241031 70 Technical Data Explosion protection Global (IECEx) Gas IECEx Pre 14.0009 Ex e mb op is IIC T5 Gb Europe (ATEX) Gas PRESAFE 14 ATEX 4571 Certifications and certificates Certificates Electrical data Rated voltage IECEx, ATEX Power consumption Service life Luminous characteristics Light intensity Ambient conditions Ambient temperature -55... +55 C Operating temperature -40... +55 C Mechanical data Degree of protection IP66 Cable glands 2 x M25 x 1.5 100... 254 V AC 24 V DC ±30 % 4... 10 W (depending on the version) Min. 50,000 working hours > 32 cd and 10 cd versions, according ICAO Annex 14 Vol. I, low intensity type A and B Accessories and Spare Parts Designation Description Order number Art. no. PS Dome with gasket TEF5631 241040 70 Screw M5x16 red. shank TEF51013028 241045 70 Drain plug drain plug EEx e M25 TEF7302101 169899 70 Stopping plugs M25 TEF6502500 241043 70 Cable glands M25 d11-15/15-20 mm TEF6222502 241042 70 Terminal insert TEF5632 241041 70 564

Perimeter Light LED Series TEF 2460 > Integrated terminal box with drain plug/breather > Low maintenance > Rugged construction > Encapsulated electronics. No risk of water intrusion to LED s and electronics > Instant light > Resistant to vibrations Series TEF 2460 16772E00 WebCode T2460B ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x Selection Table Version Lamps Light intensity Voltage Order number Art. no. PS Perimeter light LED Series TEF 2460 green LED 30 cd 100... 254 V AC TEF2460150 241034 70 24 V DC ±30 % TEF2460152 241035 70 green/red LED 30 cd 24 V DC ±30 % TEF2460153 241036 70 Technical Data Explosion protection Global (IECEx) Gas IECEx Pre 14.0009 Ex e mb op is IIC T5 Gb Europe (ATEX) Gas PRESAFE 14 ATEX 4571 Certifications and certificates Certificates IECEx, ATEX Electrical data Rated voltage 100... 254 V AC 24 V DC ±30 % Power consumption 4 W Service life Min. 50,000 working hours Luminous characteristics Light intensity > 30 cd 0... 10 > 15 cd 10... 20 > 3 cd 20... 90 < 60 cd in all directions (according ICAO Annex 14 Vol. II and CAP 437) Ambient conditions Ambient temperature -55... +55 C Operating temperature -40... +55 C Mechanical data Degree of protection IP66 Cable glands 2 x M25 x 1.5 Accessories and Spare Parts Designation Description Order number Art. no. PS Glas dome TEF50480032 241037 70 Terminal insert TEF5632 241041 70 Cable glands M25 d11-15/15-20 mm TEF6222502 241042 70 Stopping plugs M25 TEF6502500 241043 70 Drain plug drain plug EEx e M25 TEF7302101 169899 70 Screw M5x16 red. shank TEF51013028 241045 70 565

Navigation Light Series TEF 2850 Series TEF 2850 06425E00 > Integrated terminal box > Hinged on top - enabling quick replacement of light source > All round lanterns are delivered with mounting bracket for 2 pipe > Designed for use in arctic and tropical waters > Resistant to vibrations > Lens of through-coloured glass - no de-colouration throughout the lifetime of the lantern WebCode T2850A ATEX Zone 0 1 2 20 21 22 For use in x Selection Table Version Version of light fitting Colours Light aperture Order number Art. no. PS Weight Navigation light Series TEF 2850 Technical Data Explosion protection Europe (ATEX) Gas kg Masthead white 225 TEF28500029 165885 70 4.000 Starboard green 112.5 TEF28501029 165886 70 4.000 Port red 112.5 TEF28502029 165887 70 4.000 Stern white 135 TEF28503529 165890 70 4.000 Stern towing yellow 135 TEF28503329 165889 70 4.000 Suez red red 135 TEF28503229 165888 70 4.000 Allround white white 360 TEF28505029 165891 70 4.000 Allround green green 360 TEF28505129 165892 70 4.000 Allround red red 360 TEF28505229 165893 70 4.000 NEMKO Ex 99Y060 E nr II T5 (Only on request) Certifications and certificates Certificates ATEX Ship approval DNV Rated voltage 24, 120, 230 V AC / DC Lamp version 55 W for vessels 20... 50 m 85 W for vessels >50 m Degree of protection IP56 Lamp holder B22 / E27 / P28S Power consumption 55... 85 W, dependant on light source Operating temperature range -20... +40 C Material Enclosure Aluminium Lens glass coloured glass 566

Navigation Light Series TEF 2850 Accessories and Spare Parts Designation Description Order number Art. no. PS Lens clear TEF50480006 165898 70 green TEF50481003 165899 70 red TEF50482002 165900 70 yellow TEF50483002 165901 70 grey TEF50486001 165902 70 Lamp holder B22 TEF50880010 165905 70 E27 TEF50870012 165904 70 Light source 65cd, B22, 230 V TEF9400001 165909 70 65cd, B22, 120 V TEF9400002 165910 70 35cd, B22, 230 V TEF9400003 165911 70 35cd, B22, 120 V TEF9400004 165912 70 35cd, B22, 24 V TEF9400005 165913 70 40 W, P28S, 24 V TEF9400049 165916 70 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 180 200 150 260 160 100 35 25 Pg 16 11 35 95 146 180 100 06424E00 180 260 160 Pg 16 06427E00 Sector lantern TEF 2850 All round lantern TEF 2850 567

Windsock Illuminated Series TEF 9967 Series TEF 9967 WebCode T9967A 06366E00 > Wind indication on: Helicopter landing areas Airports Bridges Highways > Rugged and solid construction > 4 certified luminaires mounted in SS316L reflector with junction box > Easy to install and maintain > 1 or 2 obstruction lights on top > To be mounted on top of 2 tube > Cable for power supply through 2 tube > Resistant to vibrations > Bearing for rotating the wind cone encapsulated in solid brass housing ATEX Zone 0 1 2 20 21 22 For use in x x Selection Table Version Luminaires Voltage Size Use in Order number Art. no. PS Windsock without d = 0.6 m TEF9967013 166036 70 Series TEF 9967 L = 2.4 m d = 1.0 m L = 3.6 m TEF9967014 166037 70 with Series TEF 2430 with Series TEF 2440 120 V d = 0.6 m L = 2.4 m 230 V d = 1.0 m L = 3.6 m 120 V d = 0.6 m L = 2.4 m 120 V d = 0.6 m L = 2.4 m 230 V d = 1.0 m L = 3.6 m Zone 1 TEF9967020 211382 70 Zone 1 TEF9967009 166032 70 Zone 2 TEF9967021 211383 70 safe area TEF9967022 211384 70 Zone 2 TEF9967005 166031 70 Technical Data Rated voltage 230 / 240 V AC, 50 / 60 Hz 110 / 120 V AC, 60 Hz Power consumption <100 W Degree of protection IP66 / IP67 (acc. to IEC 529) Material Cover in acid proof steel (SS316L). Bearing in solid brass. The arrangement can be equipped with different models of luminaires from Tranberg, dependant on the area of use. Weight with luminaire Series TEF 2440, Zone 2 / safe area: 57 kg with luminaire Series TEF 2430, Zone 1: 78 kg 568

Windsock Illuminated Series TEF 9967 Accessories and Spare Parts Designation Description Order number Art. no. PS Windsock d = 0.5 m; L = 2.0 m; colour: orange TEF7852001 166039 70 d = 0.6 m; L = 2.4 m; colour: orange TEF7852004 166041 70 d = 1.0 m; L = 3.6 m; colour: orange TEF7852002 166040 70 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 1000 500 1500 (2000) 95 600 (1000) 300 2400 (3600) 06362E00 569

Windsock with Internal Illumination Series TEF 9968 Series TEF 9968 WebCode T9968A 17797E00 > Rugged and solid construction > Easy to install and maintain, maintenance free lights > The windsock is internally lit with red light, causing minimal glare and minimal reduction in pilot s ability to see in the dark > Delievered with 10 m flying lead armored cable (other lenghts on request) > Red + IR (NVG compatible) obstruction light available > Resistant to vibrations > Bearing for the rotation wind vane, is encapsulated in solid brass housing > EN/DIN mounting flange for 60.3 mm pipe > Delivered with one spare windsock kit ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x Selection Table Version Light intensity Rated voltage Size Colour Order number Art. no. Windsock Series TEF 9968 10 Cd 24 V DC d = 0.3 m L = 1.3 m orange TEF99683111 on request d = 0.6 m L = 2.4 m orange TEF99686111 on request d = 1.0 m L = 3.6 m orange TEF99681111 on request 230 V AC d = 0.3 m L = 1.3 m orange TEF99683112 on request d = 0.6 m L = 2.4 m orange TEF99686112 on request d = 1.0 m L = 3.6 m orange TEF99681112 on request 32 Cd IR 24 V DC d = 0.3 m L = 1.3 m orange TEF99683141 on request d = 0.6 m L = 2.4 m orange TEF99686141 on request d = 1.0 m L = 3.6 m orange TEF99681141 on request 230 V AC d = 0.3 m L = 1.3 m orange TEF99683122 on request d = 0.6 m L = 2.4 m orange TEF99686122 on request d = 1.0 m L = 3.6 m orange TEF99681122 on request Note The windsocks is supplied with Obstruction Lights Series TEF 2460. Special option: colour white/red on request Technical Data Explosion protection Global (IECEx) Gas IECEx PRE 14.0009 Ex e mb op is IIC T5 Gb Europe (ATEX) Gas Presafe 14ATEX4571 E II 2 G Ex e mb op is IIC T5 Gb Certifications and certificates Certificates IECEx, ATEX, IMO, CAA CAP 437, ICAO Annex 14 570

Windsock with Internal Illumination Series TEF 9968 Technical Data Electrical data Rated voltage 24 V DC +/-30 % 100... 254 V AC Power consumption 15 W Mechanical data Degree of protection IP66 / IP67 (acc. to IEC 60529) Material brass and stainless steel (EN 1.4404), polycarbonate dome on lamps Weight approx. 50 kg Ambient temperature Luminaires with Series TEF 2460 Obstruction Light Accessories and Spare Parts Designation Description Order number Art. no. PS Windsock d = 0.3 m; L = 1.3 m; colour: orange TEF7852006 241978 70 d = 0.6 m; L = 2.4 m; colour: orange TEF7852004 166041 70 d = 0.6 m; L = 2.4 m; colour: red/white TEF7852005 241977 70 d = 1.0 m; L = 3.6 m; colour: orange TEF7852002 166040 70 Full bearing for windsock arrangement TEF7850000 248112 70 Flange for mounting on 60.3 mm pipe, max Ø = 61 mm, TEF7852007 on request complete with bolts and nuts for welding to 60.3 mm pipe, EN 1.4404, TEF7852008 on request complete with bolts and nuts Power supply Please contact Tranberg AS or R. STAHL for a suitable power supply on request on request Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 165 [ 6,50] Ø Ø 125 [4,92] 125 [4,92] 4 x Ø18 [ Ø 0,71] opr.: Ex: -20... +55 C -52... +55 C L Dimensions in mm L d1 d2 TEF 99686... 2743 600 300 TEF 99683.. 1643 300 150 TEF 99681.. 3943 1000 500 1085 [42,72] d1 d2 18022E00 571

Flameproof Manual Call Points Series MCP & > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied with reset key and lift flap > Optional extras include stainless steel lift flap, duty and tag labels Series MCP 13915E00 WebCode MCPA ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x Selection Table Version Action type Enclosure colour Order number Art. no. PS Weight kg MCP Manual Call Points, Atex certification, standard devices Type Code Break glass red normal (R) MCP/BG/SP/Ex/A+B+C+D/EU/R 205324 80 1.000 Push button red normal (R) MCP/PB/SP/Ex/A+B+C+D/EU/R 205334 80 1.000 Variations MCP / _ / _ / _ / _ / _ / _ / _ / _ / _ / _ / _ Version break glass BG push button PB Contacts 1 change over SP 2 change over DP Explosion protection Cable entries standard standard 4 x M20 with 3 x Ex d stopping plugs and 1 x dust cap glands to be ordered separately Certification ATEX EU IECEx IN GOST R RU Colour red R blue B green G yellow Y black BK yellow / black stripe YB Accessories Labels (please specify wording) lift flap (break glass version only) end of line resistor inline resistor end of line and Inline resistor LED signal duty label tag label Ex A+B+C+D LF EOL IL ILEOL LED D T Additional approvals L 572

& Flameproof Manual Call Points Series MCP Versions Break Glass (BG) 14716E00 Push Button (PB) 04035E00 Technical Data Explosion protection Global (IECEx) Gas and dust IECEx BAS 08.0089X IEC 60079-0: 2011 / IEC 60079-1: 2007-04 / IEC 60079-31: 2008 Ex d IIC T6 Ta -55... +70 C Gb Ex tb IIIC T85 C Ta -55... +70 C Db IP66 Europe (ATEX) Gas and dust Certifications and certificates Electrical data Rated operational voltage Switching capacity Baseefa 08ATEX0269X EN 60079-0: 2009 / EN 60079-1: 2007 / EN 60079-31: 2009 E II 2 G Ex d IIC T6 Ta -55... +70 C Gb E II 2 D Ex tb IIIC T85 C Ta -55...+70 C Db IP66 IECEx, ATEX, Brazil (INMETRO), India (PESO) 12... 50 V DC, 12... 250 V AC DC 12... 30 V 3 A 30... 50 V 1 A AC 12... 250 V 5 A Contact element standard: 1 change-over contact optional: 2 change-over contacts Switch NO or NC System test Test key provided Ambient conditions Operating temperature range -40... +70 C Mechanical data Material Enclosure material glass fibre reinforced polyester (GRP) Surface finish two pack, acrylic polyurethane, various colour options Degree of protection IP66 acc. to IEC 60529 Cable entries 4 cable entries, supplied with (3x) Ex d stopping plugs and (1x) dust cap Position of cable entries Break glass call point Connection Terminals 7 way terminal block., 4 mm 2 Earth connection provided as standard 13952E00 16555E00 13951E00 Break glass call point with lift flap Push button call point 573