GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Similar documents
GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME. Main. Device short name. Device application

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV2P05. Main. Device short name. Device application

GV2ME. Main. Device short name. Device application

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

AS09..S 3-pole Contactors - Spring Terminals

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Datasheet - SRB-E-201ST

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

A V 50Hz / V 60Hz

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

TeSys circuit-breakers

Magnecraft Power Relays

Series CT7N Bimetallic Overload Relays

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Datasheet - SRB301LC 24VAC/DC

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Ordering details. Approval. Classification

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Type: DILM25 10(24V50HZ) Article No.:

Type: DILM12 10(24VDC) Article No.:

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Safety dialogue solutions

02/11/2015

Circuit-Breakers for Motor Protection Series 8523/8

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

Modular pulse operated latching relay 16 A

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

16 A and 25 A power contactors with or without handle

Bulletin 190 IEC Modular Starter System

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

EXPlora. Introduction

llen-bradley 194R-HM4-NFPA3

Manual Motor Starter Specifcations

DMX and 4000 air circuit breakers from 800 to 4000 A

LED control gear Compact fixed output

OT 100/ /700 P5

Minicontactorrelay,2NO/2NC,DCoperated

Magnetic and Hydraulic-Magnetic Circuit Breaker

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

High performance circuit breakers

Connecting cables for valves, round plug connectors Product range overview

LED Driver Compact dimming

LED Driver Compact fixed output

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Feed-through terminal, 2.5 mm², Screw connection, Wemid, dark beige, TS 35

Feed-through terminal, 4 mm², Screw connection, Wemid, dark beige, TS 35

LED Driver Linear / area fixed output

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath

Power Circuit of a UL508A Panel. Typical UL489 Application

ALLEN BRADLEY TIMING RELAY

Connecting cables NEBS, for sensors

LED Driver Compact fixed output

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

8 Installation Equipment

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

MVSI-TS. Technical features

Electromechanical Relays

Absolute Rotary Encoder E6CP

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Interface Relays and Optocouplers Product group picture

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Capacitors and banks 50 Hz 0 400/415 V network voltage

Transcription:

Characteristics TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Main Range Product name Device short name Product or component type Device application Trip unit technology Complementary Poles description Network type Jan 27, 2019 TeSys TeSys GV3 GV3P Circuit breaker Motor Thermal-magnetic Utilisation category AC-3 conforming to IEC 60947-4-1 Category A conforming to IEC 60947-2 Network frequency Fixing mode Operating position 3P AC 50/60 Hz Clipped on 35 mm symmetrical DIN rail Screwed on panel (with 3 x M4 screws) Any position (no direct mounting with contactor, use cable length > 10 cm) Any position (do not use with accessory GV3S) Motor power kw 45 kw at 400/415 V AC 50/60 Hz (maximum peak current 750 A) 45 kw at 500 V AC 50/60 Hz (maximum peak current 750 A) 55 kw at 690 V AC 50/60 Hz (maximum peak current 750 A) Breaking capacity [Ics] rated service short-circuit breaking capacity Control type 50 ka Icu at 440 V AC 50/60 Hz 12 ka Icu at 500 V AC 50/60 Hz 6 ka Icu at 690 V AC 50/60 Hz 50 ka Icu at 400/415 V AC 50/60 Hz 65 ka Icu at 230/240 V AC 50/60 Hz 60 % at 400/415 V AC 50/60 Hz 60 % at 440 V AC 50/60 Hz 50 % at 500 V AC 50/60 Hz 50 % at 690 V AC 50/60 Hz 100 % at 230/240 V AC 50/60 Hz Rotary knob 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

[In] rated current Thermal protection adjustment range Magnetic tripping current [Ue] rated operational voltage 80 A 70...80 A 1120 A 690 V AC 50/60 Hz [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kv conforming to IEC 60947-2 Power dissipation per pole Mechanical durability Electrical durability Operating rate 8 W 50000 cycles 20000 cycles for AC-3 at 415 V In 25 cyc/h Rated duty Continuous conforming to IEC 60947-4-1 Connections - terminals Tightening torque EverLink BTR screw connectors 2 cable(s) 1...25 mm² solid EverLink BTR screw connectors 2 cable(s) 1...25 mm² flexible with cable end EverLink BTR screw connectors 1 cable(s) 1...35 mm² solid EverLink BTR screw connectors 1 cable(s) 1...35 mm² flexible with cable end EverLink BTR screw connectors 2 cable(s) 1...25 mm² flexible EverLink BTR screw connectors 1 cable(s) 1...35 mm² flexible 5 N.m on EverLink BTR screw connectors for cable 25 mm² 8 N.m on EverLink BTR screw connectors for cable 35 mm² Mechanical robustness Shocks closed 5 Gn for 11 ms conforming to IEC 60068-2-27 Shocks opened 30 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Suitability for isolation Yes conforming to IEC 60947-1 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Height Width Depth Product weight 132 mm 55 mm 136 mm 0.96 kg Colour Grey SE GREY 6 Green SE GREEN 2 Environment Standards EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-4-1 Product certifications Protective treatment ATEX EAC IP degree of protection IP20 conforming to IEC 60529 IK degree of protection TC IK09 Ambient air temperature for operation -20...60 C Ambient air temperature for storage -40...80 C Fire resistance 960 C conforming to IEC 60695-2-1 Operating altitude 0...3000 m Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Green Premium product Compliant - since 1750 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Available Need no specific recycling operations 2

Performance Curves Thermal-Magnetic Tripping Curves Average Operating Times at 20 C Related to Multiples of the Setting Current 1a 1b 2a 2b 3 poles from cold state (Ir minimum): GV3P 3 poles from cold state (Ir maximum): GV3P 3 poles from hot state (Ir minimum): GV3P 3 poles from hot state (Ir maximum): GV3P Current Limitation on Short-Circuit (3-Phase 400/415 V) Dynamic Stress I peak = f (prospective Isc) at 1.05 Ue = 435 V 3

1 Maximum peak current 2 70-80 A (), 62-73 A (GV3P73) 3 48-65 A (GV3P65) 4 37-50 A (GV3P50) 5 30-40 A (GV3P40) 6 23-32 A (GV3P32) 7 17-25 A (GV3P25) 8 12-18 A (GV3P18) 9 9-13 A (GV3P13) Maximum Thermal Limit on Short-Circuit Thermal Limit in ka 2 s in the Magnetic Operating Zone Sum of I 2 dt = f (prospective Isc) at 1.05 Ue = 435 V 4

1 70-80 () - 62-73 (GV3P73) 2 48-65 A (GV3P65) 3 37-50 A (GV3P50) 4 30-40 A (GV3P40) 5 23-32 A (GV3P32) 6 17-25 A (GV3P25) 7 12-18 A (GV3P18) 8 9-13 A (GV3P13) 5

Dimensions Drawings GVl3L, GV3P Dimensions (1) Blocks GVAN, GVAD and GVAM11. (2) Blocks GV3AU and GV3AS. X1 = Electrical clearance (ISC max) 40 mm for Ue 500 V, 50 mm for Ue 690 V NOTE: Leave a space of 9 mm between 2 circuit breakers: either an empty space or side-mounting add-on contact blocks. Side by side mounting is possible up to 40 C. Mounting on Rail AM1 DE200 or AM1 ED201 Panel Mounting, using M4 Screws Mounting on Pre-Slotted Plate AM1 PA 6

Connections and Schema GV3P 7