INSTALLATION INSTRUCTIONS M9700 RGB SERIES Installation should be performed by a qualified electrician in accordance with the National Electrical Code and relevant local codes. Hydrel's M9700 Series of modular in-grade lights are an assembly of the following components. Each component is shipped and installed separately. Components (in order of installation): Rough-In Section MRIS rough-in housing is installed first during the electrical installation. This houses the remainder of the M9700 Series components. Power Module MHSL power module is installed within the MRIS rough-in housing. The sealed power module operates the M9700 Series MACL lamp module via the attached cord and plug. MRIS97RC -round MRIS97SC - square MHSL97 Finishing Section MFS finishing section includes the door trim and rotolock ring for the single lensed M9710 & M9730. The MFS includes the door, lens assembly and aimset ring for the double lensed M9720 and M9740. LED Module MACL LED module is installed within the MFS support/tilt ring. The sealed module is connected to the MHSL power module for operation via the waterproof cord and plug. MFS97R - round single lens MFS97S - square single lens MFS97RD - round double lens MFS97SD - square double lens MACL ROUGH-IN SECTION M9710 Round Single Lens M9720 Round Double Lens M9730 Square Single Lens M9740 Square Double Lens LED MODULE FINISHING SECTION POWER (DRIVER) MODULE WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: "Used for information purposes only. It does not govern manufacturing or inspection requirements." (ANSI Y14.5-1973)
INSTALLATION INSTRUCTIONS Installation should be performed by a qualified electrician in accordance with the National Electrical Code and relevant local codes. TO INSTALL 1. Dig hole to appropriate depth allowing for 6 minimum of pea gravel at bottom of rough-insection for drainage. M9700 RGB Housing ROUGH-IN SECTION (MRIS) SUITABLE FOR WET LOCATIONS - IP68 INSTALLATION DIAGRAM Note: More pea gravel or additional drainage may be required in locations that have poor soil drainage and/or subject to freezing. TEMPORARY COVER 2. Install the rough-in-section flush with finish grade of earth or concrete only. No specific orientation for the rough-in is required. CAUTION: WHEN INSTALLING IN ORGANIC MULCH, SURROUND ROUGH-IN-SECTION WITH APPROX. SIX INCHES (15cm) OF SAND OR OTHER NON-ORGANIC SUBSTANCE. CAUTION: TEMPORARY COVER MUST REMAIN IN HOUSING DURING INSTALLATION. 3. Connect conduits to junction box. Use suitable thread sealing compound. Duct sealant may be added to the conduit to prevent water from traveling from fixture to fixture in the event the conduit is breached. POWER DATA TO PULL ELECTRICAL CONDUCTORS 1. Remove temporary cover with fastener wrench provided. 2. Remove junction box cover and gasket. Pull the DMX signal wire into one half of the box and the power wire into the other half. You can use either the bottom or side conduits for this. The remaining pair of conduits can be used for the output or plugged if not needed. 3. Seal conduit entry with suitable compound to prevent moisture penetration from conduit system. Potting compound can be used in the junction box or plumbers putty, etc. 4. Re-install junction box cover and gasket with fasteners provided. CAUTION: DO NOT OVER TIGHTEN (20 in-lbs or 2 N-m). JUNCTION BOX DETAIL Side Entries DMX signal and power are separated by a barrier BOTTOM VIEW Bottom Entries 5. Re-install temporary cover with supplied fasteners. CAUTION: DO NOT OVER TIGHTEN (20 in-lbs or 2 N- m). CAUTION: LEAVE TEMPORARY COVER IN PLACE UNTIL READY TO INSTALL FINISHING SECTIONS. Junction box is segregated by a barrier separating the DMX signal side (low voltage) and the inline power side (120-277 volt). Each half of the junction box has a side and a bottom conduit for in and out feeds. This fixture is suitable for daisy-chaining within the junction box. WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: Used for information purposes only. It does not govern manufacturing or inspection requirements. (ANSI Y14.5-1973)
M9700 DRIVER INSTALLATION INSTALLATION INSTRUCTIONS Installation should be performed by a qualified electrician in accordance with the National Electrical Code and relevant local codes. NOTICE: DO NOT CONNECT DRIVER WHILE SYSTEM IS ENERGIZED. TURN OFF POWER PRIOR TO LAMPING. CAUTION: TEMPORARY COVER MUST REMAIN IN HOUSING UNTIL READY TO INSTALL INTERNAL COMPONENTS 1. Remove temporary cover from rough-in-section. 2. Remove junction box cover & gasket. 3. Loosen junction box cord seal nut. Run pig tailed supply cord from power module through cord seal and junction box cover (provide enough cord for proper splicing within junction box). Do the same with the data cord through the opposite side of the junction box. 4. Tighten junction box seal nut around power cord and data cord. 5. Place power module in bottom of rough-in-section. 6. Make electrical connections. Note: Use silicone-filled wire nuts or fill junction box with re-enterable potting compound (PC21) prior to replacing lid and gasket. If using potting compound be sure to seal the conduit with plumbers putty before pouring the potting compound to prevent it leaking into the conduit. 7. Re-install junction box cover and gasket. Tighten to ensure proper sealing. CAUTION: DO NOT OVER TIGHTEN (20 in-lbs or 2 N-m). POWER Power DATA Cord and plug to LED module DMX Signal DMX RGB - DOUBLE CORD TO DOUBLE CORD POWER FROM FIXTURE SUPPLY POWER - LINE VOLTAGE TO NEXT FIXTURE OR CAP WITH 120 OHM RESISTOR (by others) POWER FROM FIXTURE (DMX+ IN) (DMX- IN) (DMX+ OUT) (DMX- OUT) DMX LINE FROM NEXT FIXTURE (SHIELD BARE) WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: Used for information purposes only. It does not govern manufacturing or inspection requirements. (ANSI Y14.5-1973)
M9700 DRIVER INSTALLATION INSTALLATION INSTRUCTIONS Installation should be performed by a qualified electrician in accordance with the National Electrical Code and relevant local codes. DMX Connection and termination - wiring diagram All devices connecting to the network must be wired in a series (in and out) on the signal side. T taps or branches in the network are not permitted. RECOMMENDED CONTROLLERS Easyl DMX TOUCHSCREEN http://www.acuitybrands.com/products/detail/210270/ Fresco/Easyl/Easyl-DMX512A-Show-Controller FRESCO http://www.acuitybrands.com/products/detail/223381/ Fresco/Fresco/Touchscreen-Lighting-Controllers Easyl TM Solo Easyl TM Touch Easyl TM Pro is a standalone entry-level controller enabling show creation and playback directly at the LCD touchscreen. features an astronomic time clock for automating shows and expands the controller s features by accepting inputs from remote button stations, and button station contact closure inputs. is further enhanced by using Easyl Studio TM computer software to create multi-zone shows, and Easyl Pro features a 20 hour DMX512 capture from a theatrical console. FCS Create and edit 36 lighting scenes including intensity, color, and color temperature Integral astronomic timeclock with battery backup for system scheduling Direct DMX control for 1 universe (512 slots) Internal Bluetooth radio for wireless App control. WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: Used for information purposes only. It does not govern manufacturing or inspection requirements. (ANSI Y14.5-1973)
M9700 RGB INSTALLATION INSTALLATION DIAGRAM FINISHING SECTION INSTALLATION Door Door Top Lens LED Module Tilt Ring Rotolock Ring LED Module Rough-In Housing Aim Lock Ring Rough-In Housing Single lens fixture assemblies (M9710/M9730) Double lens fixture assemblies (M9720/M9740) 1. 2. Install rotolock ring or aimlock ring into top of rough-in housing. Do not secure ring to housing. For single lensed luminaires skip to step 3. For double lensed luminaires secure the tilt adjustment ring to lamp module while assembly is outside of the housing. Position the module into the tile ring by aligning the module pin with the tilt ring slot and then tighten the three set screws around the rim. 3. Plug driver module into base of lamp module assembly. PUSH CORD DIRECTLY INTO LAMP MODULE - DO NOT TWIST! 4. Place LED module assembly into the rotolock or aimlock ring. WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: Used for information purposes only. It does not govern manufacturing or inspection requirements. (ANSI Y14.5-1973)
M9700 RGB INSTALLATION AIMING INSTRUCTIONS CAUTION: AVOID LOOKING DIRECTLY INTO LIGHT SOURCE DURING AIMING. FIXTURE LENS MAY BECOME HOT. AVOID CONTACT WITH BARE SKIN. 5. Energize the fixture, allowing it to fully reach operating temperature and light output. 6. Rotate the LED module and its support ring (rotolock or aimlock) until desired position is achieved. 7. Once the desired aiming position is determined, secure the support ring into the housing with the attached fasteners. CAUTION: DO NOT OVER TIGHTEN (20 in-lbs or 2 N-m). 8. For the double lensed luminaires adjust the lamp module tilt by turning the single phillips head screw at the top of the module tilt ring. 9. Install the finish door assembly with the fasteners provided. CAUTION: DO NOT OVER TIGHTEN (20 in-lbs or 2 N-m). 10 20 FLC10 FLC20 Single lensed fixture can be aimed using 10 and 20 tilt lenses only. Lenses are made of prismatic glass that bend the beam of light. Tile lenses have an arrow molded into the top showing the direction the beam of light will be aimed. The entire lamp module and roto-lock ring can be spun 360 to aim. Once aiming has been set, lock the roto-lock ring down to maintain the aiming. Double lens fixtures can be mechanically and optically aimed. The LED module can be mechanically aimed up to 15 by adjusting the tilt ring. FLC10 and FLC20 tilt lenses may also be used to optically aim the beam of light. The entire lamp module and aim set ring can be spun 360 to aim. Once aiming has been set, lock the aimset ring into the housing to maintain aiming. The tilt ring is keyed into the aimset ring to ensure that fixture aiming is never compromised. WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: "Used for information purposes only. It does not govern manufacturing or inspection requirements." (ANSI Y14.5-1973)
DMX System - Ingrades DMX Controller (ordered separately) Easyl Pro controller by Acuity is the recommended console JBox #1 128 Fixtures total per DMX Universe 1 2 DMX Splitter for use with application that have more than 32 luminaires. If less than 32 luminaires skip this step. (Splitter by others) DMX IN & OUT Signal Wire JBox #2 Parallel bus for more than 32 luminaires DMX512 Bus network may be no more than 1,000 feet (300 meters) with no more than 32 devices per bus. Fixtures may either be run individually back to a junction box or sets of fixtures may be "daisy-chained" together and the entire run wired back to a junction box. Signal side and power side must be segregated in separate junction boxes and separate conduit. Diagram to the left showing the more common "daisy-chain" option. Power Conduit 10 See page 2 for detailed wiring diagrams inside of luminaire or junction box 32 Up to 32 s Per DMX Line 120 Ω resistor required on signal side Notes: 1. DMX512 signal cable must be terminated by a 120 ohm resistor. 2. Signal cable by others, cable must be two-pair with a maximum capacitance of12.8 pf/ft. and a impedance of 120 ohm. Power (120-277VAC) WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a reference dimension: "Used for information purposes only. It does not govern manufacturing or inspection requirements." (ANSI Y14.5-1973)