LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

SCALE & WEIGHT DISPLAYS

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

263 Series LED Bargraph Indicator and Controllers

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

DPM OWNERS MANUAL Website: Phone: (800)

Wall-/Pipe-Mount Level Indicator

Process Transmitter RMA 422

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Micro-DCI 53ML5100 Manual Loader

Set Point Controller OC557. Operator s Manual

Pen and Multichannel Recorder: Digital Display

DCP100 Digital Control Programmer Specifications

2 MHz Lock-In Amplifier

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

SNAP Analog Input Modules. SNAP Analog Input Modules. Features. Description. Part Number

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Process transmitter RMA422

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

AF-300 E11 Adjustable Frequency Drive

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

MICRO SERIES COUNTERS & TIMERS LARGE DIGIT MODEL

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

TempScan/1100 & MultiScan/1200

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

SY-MS121 SY-MS121-AP

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

DPR100 C/D Pen and Multichannel Recorder: Digital Display

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

ProVu PD6000 Process Meter

MT32 Telemetry Multi channel telemetry system for rotating application

DATA SHEET Panorama Rudder Indicator, TRI-2

OPTICAL POWER METER WITH SMART DETECTOR HEAD

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

4 MHz Lock-In Amplifier

Hybrid Chart Recorder 250 mm (10")

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

SIL-2 8-Ch Analog Input Series Thermocouple, High Level, Low Level

Signet 2250 Hydrostatic Level Sensor

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

HOBO H Energy Logger

SY-HDBT-100 Extender Set

Part-Turn Electric Multi-Turn Electric

2 MHz Lock-In Amplifier

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

Modular Lube Lubrication Systems System Controls

Typical applications:

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

AX 345. Process Indicator with Two Analogue Inputs, Calculations and Programmable Analogue Output. Operating Instructions for Model AX 346

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

201AN DC VOLTMETER 201AN-AC VOLTMETER

Linear flow controls VFC Linear flow controls with actuator IFC

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

High Performance Outdoor Test Translators

Capacitance Level Measurement Electronic insert FEC 12

Quick Operation Guide of LTN7700/7600 Series NVR

Standard signal metering in wall-mounting case

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Preset counters, electronic

FRQM-2 Frequency Counter & RF Multimeter

TABLE OF CONTENTS. Instructions:

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

CLOCKAUDIO. MR88 Automatic Microphone Mixer. Version 4.2

Signal Stability Analyser

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Multiple Band Outdoor Block Up- and Downconverters

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

32 Channel CPCI Board User Manual

1900/25 Vibration Monitor

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

FOM-9010, FOM-9011 and FOM-9012

SY-HDBT-SLIM-100S Extender Set

Eaton Durant. Counters, process instruments and hour meters.

LONWORKS Fibre Optic Converter

Micro-Machined Silicon Transducers

VIDEO MATRIX SWITCHES HDMI 2.0

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

Transcription:

LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200 ma and ±5A dc current ranges All ranges factory calibrated 99.99% full scale accuracy Scalable to ±99,999 for display in engineering units Up to 60 conversions per second Peak or valley capture & display Universal AC power: 85-264 Vac Built-in isolated excitation supply: 5, 10 or 24 Vdc Ratiometric compensation for variations in excitation voltage 1/8 DIN case sealed to NEMA-4X from front panel Optional serial I/O: Ethernet, USB, RS232, RS485, Ethernet-to-RS485 converter Optional relay output: dual or quad relays, contact or solid state Optional isolated analog output: 4-20 ma, 0-20 ma, 0-10V, -10 to +10V Optional low voltage power: 10-48 Vdc or 12-32 Vac Description Laureate digital process and strain panel meters are a costeffective solution to monitoring and control applications which require zero and span adjustment for process signals such as 4-20 ma, 0-5 V, 0-10 V, or strain gauges. The meters are also suitable for potentiometer follower applications, where the transducer output is a changing resistance. The display is scalable to five digits from -99,999 to +99,999 from the front panel to read directly in engineering units, such as PSI. Three scaling methods are selectable: scale and offset, two-point method, and system-level calibration using actual transducer signals. All ranges are precalibrated at the factory, so that recalibration is not needed when changing ranges or signal conditioners. Strain gauges with a 20 mv output can be scaled to display up to 10,000 counts with a 4-wire ratiometric connection, while 200 mv outputs of can be scaled to display up to 99,999 counts. For higher sensitivity, 20 mv signals can be scaled to 99,999 counts with a 4- or 6-wire connection using the Laureate load cell meter. A high input impedance of 1 Gohm is provided on 200.00 mv and 2.000 V ranges to minimize the load on the voltage signal. An isolated 5, 10 or 24 Vdc isolated excitation output is standard to power external transducers and transmitters. Up to 120 ma is provided at 10V to power four 350 ohm load cells in parallel. When powering strain gauges, load cells or potentiometers, the excitation output is monitored by the meter to eliminate errors due to voltage variations. High read rates at up to 60 or 50 conversions per second while integrating the signal over a full power cycle are provided by Concurrent Slope (US Pat 5,262,780) analog-to-digital conversion. High read rates are ideal for peak or valley capture, realtime computer interface, and control. Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data. High read rates at up to 60 or 50 conversions per second while integrating the signal over a full power cycle are provided by Concurrent Slope (US Pat 5,262,780) analog-to-digital conversion. High read rates are ideal for peak or valley capture, realtime computer interface, and control. Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or a control signal at the rear connector, or be transmitted as serial data. Digital filtering is selectable for electrically noisy environments, including a batch averaging filter and an adaptive moving average filter which provides a choice of 8 time constants from 80 ms to 9.6 s. When a significant change in signal level occurs, that filter adapts by briefly switching to the shortest time constant to follow the change, then reverts back to the selected time constant. In a selectable Auto filter mode, the filter time constant is automatically selected based on detected signal noise. Designed for system use. Optional plug-in boards include Ethernet and other serial communication boards, dual or quad relay boards, and an isolated analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with red or green LEDs. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A builtin isolated 5, 10, or 24 Vdc excitation supply can power transducers and eliminate the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs. LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 1

Specifications DC Voltage Range Resolution Input Resistance Error at 25 C ± 2 counts ±200.00 mv ±2.0000 V ±20.000 V ±200.00 V ±600.0 V * (not UL) 300.0 V 10 µv 100 µv 1 mv 10 mv 100 mv 100 mv 1 GΩ 1 GΩ 0.02% FS 0.02% FS DC Current Range Resolution Input Resistance Error at 25 C ± 2 counts ±2.0000 ma ±20.000 ma ±200.00 ma ±5.000 A 0.1 µa 1.0 µa 10 µa 1.0 ma 100 Ω 10 Ω 1 Ω 0.01 Ω 0.04% FS Display Readout Range Indicators 5 LED digits, 7-segment, 14.2 mm (.56"), red or green. -99999 to 99999 or -99990 to 99990 (count by 10) Minus sign, 2 red LED lamps A-to-D Conversion Technique A-to-D rate Output update rate Display update rate Concurrent Slope (Pat 5,262,780) 60/s at 60 Hz, 50/s at 50 Hz 56/s at 60 Hz, 47/s at 50 Hz 3.5/s at 60 Hz, 3/s at 50 Hz Accuracy Error at 25 C Span tempco Zero tempco ± 2 counts (except 5A range) 0.003% of reading/ C 0.1 count/ C Noise Rejection CMR, DC to 60 Hz NMR at 50/60 Hz 130 db 90 db with min filtering Maximum Signal Max applied voltage Current protection 600 Vac for 20, 200 and 300 V ranges, 125 Vac for other ranges 25x for 2 ma, 8x for 20 ma, 2.5x for 200 ma, 1x for 5 A Power Voltage, standard Voltage, optional Frequency Power 85-264 Vac or 90-300 Vdc (DC operation is not UL approved) 12-32 Vac or 10-48 Vdc DC or 47-63 Hz Excitation Output (standard) Selectable levels Output isolation 5 Vdc ± 5%, 100 ma; 10 Vdc ± 5%, 120 ma; 24 Vdc ± 5%, 50 ma 50 Vdc to meter ground Analog Output (optional) Output levels Current compliance Voltage compliance Scaling Resolution 4-20 ma, 0-20 ma, 0-10V, -10 to +10V (jumper selectable) 2 ma at 10V ( > 5 kω load) 12V at 20 ma (< 60Ω load) Zero and full scale adjustable from -99999 to +99999 16 bits (0.0015% of full scale) LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 2

Relay Outputs (optional) Relay types Current ratings Output common 2 Form C contact relays or 4 Form A contact relays (normally open) 2 or 4 Form A, AC/DC solid state relays (normally open) 8A at 250 Vac or 24 Vdc for contact relays 120 ma at 140 Vac or 180 Vdc for solid state relays Isolated commons for dual relays or each pair of quad relays Serial Data I/O (optional) Board selections Protocols Data rates Digital addresses Ethernet, Ethernet-to-RS485 server, USB, USB-to-RS485 server, RS485 (dual RJ11), RS485 Modbus (dual RJ45), RS232. Modbus RTU, Modbus ASCII, Laurel ASCII protocol 300 to 19200 baud 247 (Modbus), 31 (Laurel ASCII), Signal Connections Environmental Operating temperature Storage temperature Relative humidity Protection 0 C to 60 C -40 C to 85 C 95% at 40 C, non-condensing NEMA-4X (IP-65) when panel mounted Mechanical LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 3

Application Examples Potentiometer Application In potentiometric (or potentiometer follower) applications, the signal from a sliding contact voltage divider can be converted to engineering units such as position, level or percentage. By operating in a ratiometric mode, the meter will remove any effects caused by variations in the excitation supply. For use with a 1 kohm potentiometer, the recommended applied excitation voltage is 10 V, and a 2 kohm resistor should be placed in series with the excitation output and excitation return leads. This will allow the meter's 2.0000 V scale with a high input impedance of 1 Gohm to be used. Powering two-wire transmitters The isolated 24 Vdc, 50 ma excitation output, which is standard with all Laureate meters, is ideal for powering two-wire, 4-20 ma transmitters. The same two wires are used to apply voltage and carry the output current. Inside the meter, the 4-20 ma current is dropped across a 10 ohm resistor and sets up a 40-200 mv voltage, which is then sensed by the meter and scaled to engineering units. Testing with peak detection Destructive testing is an ideal application for the Laureate strain meter. Peak readings are automatically captured at rates up to 60 per second, while the display updates at a legible 3.5 readings per second. The peak reading can be recalled at the push of a button or be transmitted via RS-232 or RS-485. The meter provides isolated 10 Vdc power for up to four (4) the strain gauges and can be scaled to read out directly in engineering units from -99,999 to +99,999. Custom curve linearization The Laureate DC meter with the Extended main board option allows exceptionally accurate custom curve linearization. For setup, up to 180 data points can be entered into a spreadsheet. The system then creates multiple non-linear spline-fit segments, which provide much better accuracy than linear segments. Illustrated, is the readout of volume of irregularly shaped tanks based on measured liquid level or pressure. Altimeters and thermistors are further applications. Rate from successive readings The Extended computer board allows the display of rate based on successive readings, for instance flow rate based on changes in liquid level or static pressure in a tank. In the above illustration, the meter displays the rate in gallons at which a horizontal tank is being emptied. The input to the meter can be nonlinear, since only the linearized readings are compared for the determination of rate. LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 4

Ordering Guide Create a model a model number in this format: L10000P, IPC DPM Type Main Board L Laureate Digital Panel Meter 1 Standard Main Board, Green LEDs 2 Standard Main Board, Red LEDs 3 Extended Main Board, Green LEDs 4 Extended Main Board, Red LEDs Note: Extended capability is required for custom curve linearization or for display of time rate of change, such as flow rate from changing tank level or acceleration from changing speed. Power Relay Output Analog Output Digital Interface Signal Input 0 85-264 Vac 1 12-32 Vac & 10-48 Vdc. 1 Two 8A Contact Relays 2 Two 120 ma Solid State Relays 3 Four 8A Contact Relays 4 Four 120 ma Solid State Relays 1 Isolated 4-20 ma, 0-20 ma, 0-10 V, -10 to +10V 1 RS232 2 RS485 (dual RJ11 connectors) 4 RS485 Modbus (dual RJ45 connectors) 5 USB 6 USB-to-RS485 converter 7 Ethernet 8 Ethernet-to-RS485 converter Process Signals (e.g., 4-20 ma, 0-5 V) P Field scalable. Default Scaling is 4-20 ma = 0-100.00 P1 Custom Scaling. In the write-in field of your invoice, specify min input, min reading; max input, max reading. Strain Gage, Potentiometer Follower (4-wire ratio) SG Field Scalable. Default Scaling is 0-200 mv = 0-100.00 SG1 Custom Scaling. In the write-in field of your invoice, specify min input, min reading; max input, max reading. Note: The same DC signal conditioner board can be user-configured for process, strain, potentiometer follower, DC Volts and DC Amps. It is precalibrated in EEPROM for all Laureate DC Volt and DC Amp ranges. Add-on Options BL Blank Lens without Button Pads CBL01 RJ11-to-DB9 Cable CBL02 USB-to-DB9 Adapter CBL05 USB Cable, A to B IPC Splash-proof Cover BOX1 NEMA-4 Enclosure BOX2 NEMA-4 Enclosure plus IPC LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 5