IC-F300/F400/S SERIES PRECAUTIONS

Similar documents
Modification Information (MOD) For. Last Updated: Sep, Type:

Installation Manual VS-1200-KW1. Frequency Domain Scrambler with Multi-Format ANI VS-110- KW1. Rolling Double Inversion Scrambler VS KW1

INSTRUCTION MANUAL VHF FM TRANSCEIVER TK-190 KENWOOD CORPORATION B (K)

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

OPERATING INSTRUCTIONS

TVS-2-TAIT VPU-15-TAIT

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

of Switzerland of Switzerland Re:source FM Tuner Module Dominating Entertainment. Revox of Switzerland.

P-2 Installing the monitor (continued) Carry out as necessary

Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v August 2009

USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs)

[ Photos ] [ Wares ] [ Library ] [ Dave's Web ] [ Matt's Web ] Wares [ SWISH ] [ Simple Search ] [ Trunk Calc ]

HDMI 4x1 Quad Multi-Viewer With Seamless Switcher. Operation Manual

PCM ENCODING PREPARATION... 2 PCM the PCM ENCODER module... 4

VNS2200 Amplifier & Controller Installation Guide

RF Detector with Real Time remote Monitoring Capability Protect from RF Audio/Video Transmitters and Laser Monitoring System USER MANUAL rev.

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

D-Star the Easy Way Using the DV Dongle

Enterview 2 / Enterview 2V 4 WIRE VIDEO DOORPHONE SYSTEM

ex 800 Series ematrix System

Ten-Tec (865) Service Department:(865)

VM-99U. Professional UHF Wireless Microphone System. Operating Instructions

INSTALLATION INSTRUCTIONS FOR

MODEL 5493A DTMF MODEM

LED Backlight for Technics amplifiers

VNS2210 Amplifier & Controller Installation Guide

1. Unlocking your FT847 to get 4m ( for those who already have unlocked one, please move to chapter 2).

SAILOR CAS 3500/3700 Headend. Installation manual

Active UTP Transceiver Hub Installation Guide

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

STSW1001T STSW1001R STSW1001 INSTALLATION / USER'S MANUAL

Panadapter for FT1000mp with a PMSDR and Hamradio deluxe Cat/ logging application

Notes for the replacement of the SD2931 Devices fitted to the ICOM IC-7800 Transceiver by Glenn McNeil VK4BG. Disclaimer

EBU INTERFACES FOR 625 LINE DIGITAL VIDEO SIGNALS AT THE 4:2:2 LEVEL OF CCIR RECOMMENDATION 601 CONTENTS

INSTRUCTION MANUAL. 19 HD Widescreen Water Resistant Television VSPA19LCD-AE1B VSPA19LCD-AE1M VSPA19LCD-AE1W. Model No. FINGER TOUCH TECHNOLOGY RATED

Multi-Key v2.4 Multi-Function Amplifier Keying Interface

Atari 400/800 Super Color CPU Card

TV CHANNEL INSTALLATION

NewScope-7A Operating Manual

2000 Series Weather Stations Analog Temperature / RH Sensor Upgrade Kit PRODUCT MANUAL KIT # 3613WDU

PIEXX IC-EX243 px Installation Instructions

OTD-3000 FREQUENCY AGILE TELEVISION DEMODULATOR INSTRUCTION MANUAL

PLL1920M LED LCD Monitor

Connecting the Elecraft Power Combo to the Kenwood TS-2000 series Transceiver

ATVC-4 Plus Amateur Television Repeater Controller Copyright Intuitive Circuits, LLC

and Re:system MR-Slave Module Dominating Entertainment. Revox of Switzerland.

Spectra Batten (Order code: LEDJ95)

DM1624, DM1612, DM812

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

Model GS Port Node 1 GHz with 65/86 MHz split

ENG-44 Field Portable Audio Mixer. Operator s Manual. SignVideo SE Gideon Street - Portland, Oregon

Programmable Video Signal Generator VG-880. Instruction Manual. Ver 1.10

PATCH PANEL Easy Patch INSTRUCTION MANUAL

Operating Instructions

Installation Guide VL-MV10. Model No.

PLEASE READ THIS PRODUCT MANUAL CAREFULLY BEFORE USING THIS PRODUCT.

Absolute Encoders Multiturn

AT Active Iridium Antenna User Manual

AI-1616L-LPE. Features. High-precision Analog input board (Low Profile size) for PCI Express AI-1616L-LPE 1. Ver.1.02 Ver.1.01

VHF + UHF Amplified HDTV Antenna Model OA8000 & OA8001 Installation Instructions Reception Frequencies

Network Disk Recorder WJ-ND200

Gazer VI700A-SYNC/IN and VI700W- SYNC/IN INSTALLATION MANUAL

Model: S-4904T/R. Wireless HD Transmission System. User Manual. Please read this User Manual throughout before using.

EVENT INPUT/OUTPUT MODULE [PUME]

1. Uses. 2. Power Supply. 1) Removal or Positioning of Weld Lines. 2) Regulation of the Injection Quantity by Gate Operation

PLUSTV 1680ex USER S MANUAL

P XGA TFT Monitor. User s Manual

ACTIVE IF SPLITTER/COMBINER UHP-IFS

Hardware User s Manual

GSM TELEPHONE SGH-D900 GSM TELEPHONE CONTENTS. 1. Safety Precautions. 2. Specification. 3. Product Function. 4. Array course control

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

Magelis XBT ZG43 Backlight Replacement Kit Quick Reference Guide

DX-10 tm Digital Interface User s Guide

LDG M-7600 External Meter for Icom IC-7600

On-screen display signal strength meter Version 1.02

Multi RF Deck / Multi Control Head

Telesto Private Wire Modem Manual

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

GammaSafe System. Exertus Selen Circa Projectors. Emergency Source Retrieval

IQORX30 / IQORX31. Single Mode Fiber Optic Receivers for 3G/HD/SD-SDI Signals

TVS-2-KW2 VPU-15-KW2

Dissolve Control Programming : Projector/Dissolve Control Hook-Up

Wireless 5.8GHz AV Sender With Built in Remote Control Extender

Model 6010 Four Channel 20-Bit Audio ADC Data Pack

KTC-V300P TV TUNER INSTRUCTION MANUAL B /00 (MV)

EVF 300 series. Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit.

PU-Q1H4C. v1.3 1 to 4 HDMI to CAT 6 Distribution Amplifier OPERATION MANUAL

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

Intraplex VF-25 Four-Port PCM E&M Voice Module

MODEL 2018 OPERATION MANUAL Firmware Version

A3U5 Replacement 1705A Spectrum Monitor

of Switzerland FM Tuner MK2 E 2.01

UH8060S. Remote Speaker MIC UHF CB Transceiver. For more exciting new products please visit our website: Australia:

User Manual. SWIT ELECTRONICS CO., LTD Model: S-4904P Wireless HD Transmission System(with Panel Receiver) Ver:A

Instructions CCTV. ule. Even audio! Instructions - Instructions - Instructions. Send 2 Video Signals Down 1x Co-ax Cable...

RSL MusicPower Plug-In Installation Manual For Naim NAC 72 Preamp

Gazer VI700A-SYNC2 and VI700W- SYNC2 INSTALLATION MANUAL

Yaesu FT-950 and FT-450D with KPA/KAT500 Power Combo

CSA x2 Alarming RS-232 Seq. Video Switcher. Instruction Manual

Transcription:

SCRAMBLER UNIT INSTALLATION INSTRUCTIONS UT-109/UT-110 Rev.1.2 Thank you for purchasing the UT-109/UT-110 SCRAMBLER UNIT. The UT-109 and UT-110 are designed for Icom F series VHF/UHF FM transceivers. Please read these instructions thoroughly before installing and operating the UT-109/UT-110. Some transceiver versions will not be able to have scrambler units installed because of CPU revision and other factors. Please confirm that the transceivers serial number is over 50000. UT-109 and UT-110 scrambler units require some PC board modifications. (See below.) There are 2 versions (#01: Low AF level type for IC- F3/F4/S series and #02: High AF level type for the The scrambler unit may be installed between the mic amplifier circuit and AF circuit. Cut or desolder the junction points (or take off jumper chip for IC-F3/F4/S series). SP MIC Scrambler unit B A * *normal way IC-F300/F400/S SERIES PRECAUTIONS PC BOARD MODIFICATION Block diagram A, B: junction points others) for each scrambler unit. Do not install the wrong version, as they are not compatible. IC-F300/F400/S series require the #02 type scrambler unit. The UT-110 may function as the UT-109 through cloning software. Compatible cloning software: CS-F300S, CS-F300. M IC-F300/F400/S series q Turn power OFF, then disconnect the DC power cable. w Unscrew the 4 screws, then remove the bottom cover. e Cut or desolder the print pattern on the PC board at the TX mic circuit (A) and RX AF circuit (B). r Install the unit as shown in the instruction manual. t Replace the bottom cover and screws, then the DC power cable. NOTE: Modification points are marked A or B on the circuit board. (see corresponding figures) A : TX modulation circuit. B : RX AF circuit. * Desolder, remove a jumper chip or cut the pattern Program the scrambler function ON/OFF and scrambler codes on the [Memory CH] screen, scrambler type*, group codes*, synchronous capture mode* and tone start timing* on the [Common] screen with cloning software when installing this unit. (*UT-110 only) or or CLONING NOTE FOR REMOVAL Assign the scrambler function to a programmable key as [SCRM] on [Key & Display Assign] screen, if required. Operation with the [SCRM] key: Push and hold to turn the voice scrambler function ON. Push to turn the voice scrambler function OFF. Be sure to resolder above disconnected points, otherwise no TX modulation or AF output is available when you remove the scrambler units. - 1 -

M Model: IC-F300/S series Main board A and B. IC-F300/F400/S SERIES MODIFICATION POINTS REAR ANT A B M Model: IC-F400/S series Main board A and B. REAR ANT B A - 2 -

APPENDIX -1; IC-F3/F4/S SERIES PRECAUTIONS Some transceiver versions will not be able to have scrambler units installed because of CPU revision and other factors. Please confirm that the transceivers serial number is over 50000. UT-109 and UT-110 scrambler units require some PC board modifications. (See below.) IC-F3/F4/S series require a #01: Low level type scrambler unit. Do not install the wrong version, as M IC-F3/F4/S series There are 2 types of PC boards are exist. Be sure to confirm the board number in advance. IC-F3/IC-F3S B4929E requires LCD side and CPU side modifications. B4929F* 1 requires CPU side only. IC-F4/IC-F4S B4923G LCD side and CPU side modifications. B4923H* 1 requires CPU side only. q Take out the knob and unscrew the antenna connector screw. w Unscrew the 2 screws, then remove the front panel. e Remove the shield cover if necessary. r Remove the jumper chip (DET)* 2 or (AF)* 2 on the LCD side of the PC board. t Replace the shield cover to the original position. y Remove the jumper chip resistor(s) on the CPU side of the PC board. (see right figures) u Install the unit as shown in the instruction manual. i Replace the front panel and screws. NOTE: *1 B4929F and B4923H's modification points may access through the service window without take PC BOARD MODIFICATION they are not compatible. The UT-110 may function as the UT-109 through cloning software. Compatible cloning software: CS-F3. apart. *2 Modification points are marked DET or AF on the main board. (see below figures) Program the scrambler function ON/OFF and scrambler codes on the [Memory CH] screen, scrambler type*, group codes*, synchronous capture mode* and tone start timing* on the [Common] screen with cloning software when installing this unit. (*UT-110 only) Assign the scrambler function to a programmable key as [SCRM] on [Key & Display Assign] screen, if required. Operation with the [SCRM] key: CLONING Push and hold to turn the voice scrambler function ON. Push to turn the voice scrambler function OFF. NOTE FOR REMOVAL Be sure to resolder above disconnected points, otherwise no TX modulation or AF output is available when you remove the scrambler units. - 3 -

1 IC-F3/F4 SERIES MODIFICATION POINTS C167 C169 C164 C21 C2 C1 C77 C166 C168 C165 R54 R1 R56 R132 J6 C1 R142 R130 C147 R128 Q17 R144 C163 C154 IC5 C151 C152 X3 C114 C116 R82 R131 R244 R127 C150 C117 MC1 R84 R85 C115 C113 R239 C119 C112 R83 IC2 C121 R86 C110 C122 Q14 R79 R90 R88 R87 R80 R91 C120 C118 R253 D7 C69 C59 C63 C57 C64 C55 L30 R89 R112 R45 R100 R169 R44 R170 R81 C129 R167 C111 R168 C213 C217 R178 R99 C132 C212 C214 C290 C124 C125 C126 C134 C179 C133 C131 C75 C50 C54 IC1 R95 R177 R96 C286 R257 R166 R109 IC4 R107 R98 R113 R108 R94 C211 Q34 R176 R93 R105 C238 IC3 C244 R175 R151 R185 R104 C237 R251 Q11 C234 R52 R159 R30 C291 D19 C135 C73 IC10 R31 Q37 C243 R117 R106 R154 D29 C219 R53 R114 C136 R97 R153 C20 C137 R115 C240 R210 C239 C241 C288 R160 C242 R55 R116 R250 D3 C79 R16 L26 L27 R9 L5 L6 R255 C19 C25 C14 C13 R7 C17 R8 C18 C22 C78 D8 C204 L24 C289 C287 C12 Q3 R5 L28 C280 C23 R14 L3 R4 R10 L2 SPEAKER SP1 1 J7 M Model: IC-F3/IC-F3S PC board number B4929E; Remove the LCD side jumper chip and the CPU side jumper chip q. B4929F; Remove the CPU side jumper chips q and w. LCD side: B4929E only. CPU side DET Remove the resister from the board. SP SPG P1 ANTENNA MICROPHONE C205 Q2 L7 C278 C11 C15 C24 R13 R15 C26 C46 Q1 C5 D1 R6 C16 R11 R12 C8 L23 L4 C279 Service window w Jumper q chips B4929F or E M Model: IC-F4/IC-F4S PC board number B4923G; Remove the LCD side jumper chip and the CPU side jumper chip q. B4923H; Remove the CPU side jumper chips q and w. LCD side: B4923G only. CPU side C146 C152 SPEAKER SP1 AF Remove the resister from the board. C167 J6 SP SPG P1 C166 R132 L412 C165 ANTENNA C10 C496 R128 R1 R1 C179 C18 R3 MICROPHONE R142 C112 R135 R134 C156 R83 C408 L22 R408 R444 C116 C142 C154 D402 Q19 IC6 C113 C114 J7 C115 R406 R407 MC1 R137 R442 Q18 C162 R141 Q22 R107 R424 X3 Q400 R84 C51 R46 R82 C160 Q20 C63 R126 C124 C149 R176 C451 L13 R45 C117 IC2 R40 C52 C217 R85 C64 D27 R452 C120 C118 R44 R123 R450 Q404 C456 R469 C169 R122 C491 IC1 Q31 R120 C242 D405 R174 C450 C140 R121 IC5 Q16 C60 R451 C238 C415 C109 C107 C61 R41 R96 R100 C139 R65 R67 R154 L404 C151 C237 R32 R34 R33 C125 R93 R94 C150 R54 R99 L14 R459 R178 C126 R464 C443 R127 IC10 Q13 R414 Q401 R405 L20 C134 L12 C133 R95 R108 R409 C48 L414 Q37 R63 C108 Q402 C239 C106 R415 L407 C47 R105 IC3 R420 C62 C240 R153 C477 Q34 R210 C73 R52 R159 R104 R109 R70 R72 C99 C30 R421 C465 IC4 Q9 C218 Q28 R162 R114 R454 C497 C464 R77 R21 C473 C419 R115 R184 D404 R53 C75 R438 D406 C135 L15 R117 L21 C479 C137 R453 C128 R69 R68 D4 C32 R19 C483 C211 L406 C234 C136 R97 R422 R163 C9 C448 R116 D3 C27 C42 C3 C11 C14 C474 R112 C455 R160 R165 D1 C486 R439 L5 R17 L1 C20 C482 R8 R209 C229 C76 C5 C7 C8 L24 C204 C467 C481 R9 R5 C17 C13 Q2 R449 C26 R14 C452 C476 L6 Q1 R55 C460 Q403 R455 R208 D24 R458 R457 R7 C487 R157 C170 R156 W6 C458 Q3 R446 C205 R12 R158 L411 C25 C22 C15 C492 C202 C201 C200 Jumper chips w q B4923H or G Service window - 4 -

M Memory CH screen APPENDIX -2; CLONING -1 D SCRAMBLER ON/OFF/INH Turns the scrambler function "ON" or "OFF" as a initial setting. This item can also be turned "ON" or "OFF" with a program function switch when the function is assigned to a switch. "INH": This means the scrambler function selection is inhibited. Optional UT-109 or UT-110 Voice scrambler unit is required. D Scrambler code Set the scrambler code number. Selectable value; UT-109: 1 to 32 UT-110: 1 to 255 *Set the scrambler group code in the Common screen in advance. (UT-110 only) M Common 2 screen NOTE: This setting is invalid for UT-109. NOTE: The following setting will be invalid: Scrambler Group Code D SYNCHRONOUS CAPTURE (UT-110 only) "Synchronous capture mode" is useful when communicating through a repeater. However, because of voice components, the transceiver can not maintain synchronous mode in rare cases. Normally it is best to set this item to "Standard". Selectable value; Standard (Normal operation) Continuous (repeater operation) D TONE START TIMING (UT-110 only) D SCRAMBLER GROUP CODE (UT-110 only) Set the scrambler group code. Selectable value; 1 to 4. Optional scrambler unit (UT-110) is required. NOTE: This setting is invalid for UT-109. Tone start timing selects the synchronous tone signal transmit delay time. Set the delay time when the other party's transceiver has power save mode. Selectable value; OFF(default) 0.300s, 0.600s, 1.100s D SCRAMBLER TYPE (UT-110 only) Set the UT-110 Rolling type scrambler as UT-109 Non-rolling type. As UT-110 and UT-109 have different code settings, they are not compatible. By selecting Non-rolling type in this item, you can use UT-110 as UT-109. Selectable value; Rolling type (UT-110 normal) Non-rolling type (UT-110 functions as UT-109) - 5 -

M Setting examples APPENDIX-2; CLONING NOTES (CS-F3 and CS-F300/S) Below examples are not always needed settings, but will be useful in cases after transmitting a synchronous tone to notify operator of times to start talking. M IC-F3/F4/S series Generally, channels with voice scrambler settings should have the power save function in the Memory CH screen turned OFF. When you want to use the voice scrambler function on channels in which the power saver function is ON, set the Tone Start Timing in the Common screen to 1.100. For LMR: In the Common 2 screen, set the Tone Start Timing to 1.100. In the TX Code CH screen, set CH NO.1 to 1 only. In the TX Code Common screen, set the Long Tone Timer to 0.300. In the memory CH screen, set necessary channel ID's to 1L (push space key to turn the Long Tone ON/OFF). (CCIR 5-tone format) In the memory CH screen, set necessary channels to LOG IN. NOTE: At above settings, when the period from pushing PTT to when you can talk seems long, set the 2nd timer in the Expert screen to OFF and set the Tone Start Timing to 0.600. In the memory CH screen, return necessary channel ID's to 1 from 1L. M Other notes For communication between F300/F400/S series and F3/F4/S series, make sure that the F3/F4/S series power saver settings are set to the same values as the F300/F400/S series Tone Start Timing settings. In the Common 2 screen, set the Tone Start Timing to 1.100. In the DTMF Autodial screen, set the LOG/ID code to 5 and the 1st Timer to 0.700. In the memory CH screen, set necessary channels to LOG IN (L-IN). NOTE: At these settings, when the period from pushing PTT to when you can talk seems long, set the 2nd timer in the Expert screen to OFF and set the Tone Start Timing to 0.600. In the DTMF Autodial screen, set the 1st Timer to 0.200. For PMR: When using the UT-109/UT-110 for non-rolling type scrambling there are 32 available scramble codes. In the memory CH screen, 1 to 255 can be input as codes however, many of these codes are identical (adding 32 to a code results in the same scramble code). The following groups of codes are the same: 1 to 32 (33 to 64) (65 to 96) (97 to 128) (129 to 160) (161 to 192) (193 to 224) (225 to 255) When using the UT-110 for rolling type scrambling similar but different codes will often result in a match. To avoid this, use codes that are sufficiently different (generally speaking codes that are separated by values of 20 or more will not match). When using the UT-110 for rolling type scrambling and a channel is in the scramble ON condition, if a received signal includes no simultaneous tone, the receiving station automatically enters the through condition and the transmission can be monitored. How ever, when non-rolling type scrambling is set, simultaneous tone are not used and therefore signals from other stations are received with modulation reversed. - 6 -

APPENDIX -3; IC-F3GT/GS, IC-F4GT/GS SERIES PRECAUTIONS UT-109 and UT-110 scrambler units require some PC board modifications. (See below.) IC-F3GT/GS, IC-F4GT/GS series require a #01: Low level type scrambler unit. Do not install the wrong version, as they are not compatible. The UT-110 may function as the UT-109 through cloning software. Compatible cloning software: CS-F3G. M Cut junction patterns Cut the junction patterns before install the scrambler unit. PC BOARD MODIFICATION q Take off the optional connector access cover. Insert a screwdriver into the hollow of the chassis, then lift and take away the cover. (The cover can not be used again.) w Cut the patterns which marked C and F. e Install the unit as shown in the right. r Remove the paper backing of 2251 OPT sheet supplied as accessory. t Attach the new 2251 OPT sheet to the service window. y Program the necessary information with the cloning software before operation. q t r e Program the scrambler function ON/OFF/Inhibit and scrambler codes on the Edit Memory CH screen, Scrambler type*, Group code*, Synchronous Capture mode* and Tone Start Timing* on the [Common 2] screen with cloning software when installing this unit. (*UT-110 only) Assign the scrambler function to a programmable key as Scrambler on Key & Display Assign screen, if required. CLONING Operation with the [SCRM] key: Push and hold to turn the voice scrambler function ON. Push to turn the voice scrambler function OFF. Be sure to resolder above disconnected points, otherwise no TX modulation or AF output is available when you remove the scrambler units. NOTE FOR REMOVAL - 7 -

M Model: IC-F3GT/GS IC-F3GT/GS, IC-F4GT/GS SERIES MODIFICATION POINTS Modification points. (C and F) Cut the junction patterns C and F on the PC board. C F Service window M Model: IC-F4GT/IC-F4GS Modification points. (C and F) Cut the junction patterns C and F on the PC board same as above. F C Service window - 8 -

IC-F3GT/GS, IC-F4GT/GS SERIES CLONING -1 M Edit Memory CH screen D SCRAMBLER ON/OFF/Inhibit Turns the scrambler function "ON" or "OFF" as a initial setting. This item can also be turned "ON" or "OFF" with a program function switch when the function is assigned to a switch. "Inhibit": This means the scrambler function selection is inhibited. D Scrambler code Set the scrambler code number. Selectable value; UT-109: 1 to 32 UT-110: 1 to 255 *UT-110 requires to set the scrambler group code (1 to 4) in the Common 2 screen. Use the same Group Code and Scrambler code for same group. M Common 2 screen D SCRAMBLER TYPE (UT-110 only) Set the UT-110 Rolling type scrambler as UT-109 Nonrolling type. As UT-110 and UT-109 have different code settings, they are not compatible. By selecting Non-rolling type in this item, you can use UT-110 as UT-109. Selectable value; Rolling type (UT-110 normal) Non-rolling type (UT-110 functions as UT-109) NOTE: This setting is invalid for UT-109. D SCRAMBLER GROUP CODE (UT-110 only) D SYNCHRONOUS CAPTURE (UT-110 only) "Synchronous capture mode" is useful when communicating through a repeater. However, because of voice components, the transceiver can not maintain synchronous mode in rare cases. Normally it is best to set this item to "Standard". Selectable value; Standard (Normal operation) Continuous (repeater operation) D TONE START TIMING (UT-110 only) Tone start timing selects the synchronous tone signal transmit delay time. Set the delay time when the other party's transceiver has power save mode. Selectable value; OFF(default) 0.300s, 0.600s, 1.100s UT-110 has 1020 (4 groups x 255) code numbers for providing higher communication security. Use the same scrambler group code for same group. Selectable value; 1 to 4. NOTE: This setting is invalid for UT-109. - 9 -

M Setting examples IC-F3GT/GS, IC-F4GT/GS SERIES CLONING NOTES Below examples are not always needed settings, but will be useful in cases after transmitting a synchronous tone to notify operator of times to start M Other notes For communication between F300/F400/S series and F3GT/GS, F4GT/GS series, make sure that the F3GT/GS, F4GT/GS series power saver settings are set to the same values as the F300/F400/S series Tone Start Timing settings. M IC-F3GT/GS, IC-F4GT/GS series Generally, channels with voice scrambler settings should have the power save function in the Edit Memory CH screen turned OFF. When you want to use the voice scrambler function on channels in which the power saver function is ON, set the Tone Start Timing in the Common 2 screen to 1.100. In above case, non-scrambling voice will be transmitted approx. 1 sec. after pushing PTT. When using the UT-110 as rolling type scrambler unit to keep the highest level of privacy, the LOG IN function provides full time scrambling communications. M Using LOG IN function For LMR: In the Common 2 screen, set the Tone Start Timing to 1.100. In the DTMF Autodial screen, set the LOG/ID code to 5 and the 1st Timer to 0.700. In the memory CH screen, set necessary channels to LOG IN (L-IN). NOTE: At these settings, when the period from pushing PTT to when you can talk seems long, set the Power Save Start timer (2nd) in the Expert screen to 0.000 and set the Tone Start Timing in the Common 2 screen to 0.600. In the DTMF Autodial screen, set the 1st Timer to 0.200. When using the UT-109/UT-110 for non-rolling type scrambling there are 32 available scramble codes. In the memory CH screen, 1 to 255 can be input as codes however, many of these codes are identical (adding 32 to a code results in the same scramble code). The following groups of codes are the same: 1 to 32 (33 to 64) (65 to 96) (97 to 128) (129 to 160) (161 to 192) (193 to 224) (225 to 255) When using the UT-110 for rolling type scrambling similar but different codes will often result in a match. To avoid this, use codes that are sufficiently different (generally speaking codes that are separated by values of 20 or more will not match). When using the UT-110 for rolling type scrambling and a channel is in the scramble ON condition, if a received signal includes no simultaneous tone, the receiving station automatically enters the through condition and the transmission can be monitored. However, when non-rolling type scrambling is set, simultaneous tone are not used and therefore signals from other stations are received with modulation reversed. For PMR: In the Common 2 screen, set the Tone Start Timing to 1.100. In the TX Code CH screen, set CH NO.1 to 1 only. In the 5Tone setting screen, set the Long Tone Timer to 0.300. In the Edit Memory CH screen, set necessary channel ID's to 1L (click check box to turn the Long Tone ON). (CCIR 5-tone format) In the memory CH screen, set necessary channels to LOG IN (L-IN). NOTE: At above settings, when the period from pushing PTT to when you can talk seems long, set the Power Save Start timer (2nd) in the Expert screen to 0.000 and set the Tone Start Timing to 0.600. In the memory CH screen, return necessary channel ID's to 1 from 1L. - 10 -

APPENDIX-4; IC-F1010/F1020/F2010/F2020 SERIES MODIFICATION POINTS M Model: IC-F1000/F2000 series Cut the junction patterns on Main board AFO and MIC. FRONT MAIN unit MIC UT-109/110 AFO CLONING UT-109 and UT-110 scrambler units require some PC board modifications. (See above MIC and AFO.) IC-F1010/F1020, IC-F2010/F2020 series require a #02: High AF level type scrambler unit. Do not install the wrong version, as they are not compatible. The UT-110 may function as the UT-109 through cloning software. Compatible cloning software: CS-F1000 Rev.2.2. Program the scrambler function OFF/ON/INH and scrambler codes on the Memory Channel screen, Scrambler Type*, Group Code*, Synchronous Capture* and Tone Start Timing* on the [Common 2] screen with cloning software when installing scrambler unit. (*UT-110 only) Assign the scrambler function to a programmable key as Scrambler on [Key & Display Assign] screen, if required. Operation with the [Scrambler] key: Push and hold to turn the voice scrambler function ON. Push to turn the voice scrambler function OFF. Please refer the IC-F3/F4/S SERIES CLONING PRECAUTIONS on p. 3. Be sure to resolder above disconnected points, otherwise no TX modulation or AF output is available when you remove the scrambler units. NOTE FOR REMOVAL - 11 -

APPENDIX -4; IC-F30/F31GT/GS, IC-F40/F41GT/GS SERIES PRECAUTIONS UT-109 and UT-110 scrambler units require some PC board modifications. (See below and next.) IC-F30/F31GT/GS, IC-F40/F41GT/GS series require a #02: High AF level type scrambler unit. Do not install the wrong version, as they are not compatible. The UT-110 may function as the UT-109 through cloning software. Compatible cloning software: CS-F30G. M Installation Disassemble the some parts before install the scrambler unit. OPTIONAL UNIT INSTALLATION c e q Unscrew nut a, and remove the knobs. w Unscrew screw b and 2 screws c, then remove the multi-connector cover and rear panel. e Unscrew 2 screws d, then remove the multi-connector. r Unscrew 2 screws e, then take off the chassis from the front panel in the direction of the arrow. Be careful!: Flat cable is connected between the MAIN unit on the chassis and front panel. t Install the desired optional unit. Insert tightly to avoid bad contact. NOTE: When installing UT-105 or UT-111, the unit MUST BE plugged into OPT1. Otherwise the unit will not work correctly. (Other optional units can be plugged into either slot.) a d d b y Program the necessary information with the cloning software before operation. OPT1 OPT2 Program the scrambler function ON/OFF/Inhibit and scrambler codes on the Edit Memory CH screen, Scrambler type*, Group code*, Synchronous Capture mode* and Tone Start Timing* on the [Common 2] screen with cloning software when installing scrambler unit. (*UT-110 only) Assign the scrambler function to a programmable key as Scrambler on Key & Display Assign screen, if required. Operation with the [Scrambler] key: Push and hold to turn the voice scrambler function ON. Push to turn the voice scrambler function OFF. Be sure to resolder disconnected points, otherwise no TX modulation or AF output is available after you remove the scrambler units. CLONING NOTE FOR REMOVAL Please refer the IC-F3GT/GS, IC-F4GT/GS SERIES CLONING NOTES on p. 10. - 12 -

MODIFICATION POINTS Modification points. (Both IC-F30/F31GT/GS, F40/F41GT/GS) Cut the junction patterns A and B on the MAIN unit. urface A AF line MIC line B OPT1 connector for; UT-105, UT-111, UT-109/110, UT-113 J1 E 1 30 10 5 OPT1 20 25 15 16 J2 10 5 G 1 OPT2 20 25 30 15 16 OPT2 connector for; UT-109/110, UT-113 *DO NOT install UT-105 or UT-111 into OPT2. C D F MAIN unit 1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003 Japan - 13 - A-8326I-1EX-w 09.2000 Count on us! Printed in Japan 1997 Icom Inc.