Safety Light Curtains

Similar documents
The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

Safety Light Curtains GuardShield

Safety Light Curtain Orion1 Extended

SAFETY SAFETY LIGHT CURTAINS SG EXTENDED FINGER & HAND PROTECTION SG2-M & SG4-E SERIES HIGHLIGHTS APPLICATIONS

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

SIMATIC FS400 light curtains and arrays

GENERAL INFORMATION...1

Safety Light Curtains

SF2 Series Instruction Manual INDEX

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Lt DELTA USA, Inc

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Safety Light Curtain C 4000 Basic/Micro

Quick-disconnect cables. Adjustable mounting brackets

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Safety Light Curtain C 4000

User Manual. SafeShield Safety Light Curtain Hardware

Photoelectrics Through-beam Type PA18C.T..., DC

OPERATING INSTRUCTIONS. detec2 Core Safety light curtain

Safety Light Curtain Type4 SIL3 PLe

Note The information contained in this document may be changed or supplemented without prior notice.

Quick-disconnect cables. Adjustable mounting brackets

F3SG-RA. Safety Light Curtain. Advanced Safety Light Curtain in Rugged, IP67 Rated Housing. Online. Blanking

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Specifications. Response Time. Status Indicators. Scanning Range/Resolution. Vibration. Shock. Physical Characteristics.

PHOTOELECTRIC SAFETY BARRIER ADMIRAL AX BK INSTALLATION USE AND MAINTENANCE INTRODUCTION... 2 OPERATION... 3 INSTALLATION... 4

Electrical connection

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Safety Light Curtain C 4000

Electrical connection

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Cylindrical Photoelectric Sensor CY-100 SERIES

APPLICATIONS. Automatic warehouse. Trasportation lines

Operating Instructions

EZ-SCREEN. Type 4 Point-of-Operation V-Series No configuration necessary; preconfigured for Trip Output, Scan Code 1, MACHINE SAFETY

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

C 4000 Palletizer Standard/Advanced Safety Light Curtain

Electrical connection

LD OEM/LD PDS/LD PeCo

EZ-SCREEN LS. Safety Light Screen

Light Curtain Type LA

Allen-Bradley Automation

Safe Switching with Safe Contactors

POC Type 4 GuardShield Standard, Remote Teach & Cascadable Safety Light Curtains

Photoelectric Sensors E3F2

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

panasonic-electric-works.net/sunx Machine safeguarding without sacrificing productivity

LUT Luminescence scanners: Seeing what no-one else can

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Electrical connection

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

>Inductive. REFERENCE guide. Proximity

OM2000N INSTALLATION MANUAL

Product Description Sheet Loctite CL10 Quad LED Controller

APPLICATIONS. Automatic warehouse. Trasportation lines

V 180 Series Photoelectric Switches

KVANT. Spectrum 1,6W RGB laser system. Product datasheet

>Inductive and. REFERENCE guide. Capacitive Sensors

SQM40/41 Actuators for air and gas dampers

LITE-ON TECHNOLOGY CORPORATION

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

PSM-003. Micro Polarization Controller/Scrambler. User Guide

Contactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines

ultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs

HSME-C400. Data Sheet. Side-Fire Mono-Color Surface-Mount ChipLED. Features. Description. Applications

Through Hole Lamp Product Data Sheet LTW-2S3D7 Spec No.: DS Effective Date: 10/06/2012 LITE-ON DCC RELEASE

Multi-functional safety relay modules PROTECT SRB-E

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Instruction Manual SF4B- -01<V2> Light Curtain / Type panasonic.net/id/pidsx/global

Operating instructions Electronic preset counter Type series 717

Ordering details. Approval. Classification

...Simple IT WORKS WHY MERLIN 3000 FOR PRESS BRAKES? SIMPLE... Merlin 3000 was designed specifically for press brakes.

Quick-disconnect cables. Adjustable mounting brackets

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

2-12. General Principles 2-Opto-electronics Safety Switches Operator. Interface. Logic Power

Inductive sensor NI3-EG08K-Y1-H1341

Industrial Diode Laser (IDL) System IDL Series

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

SPACESCAN SERIES SS 02

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Operating instructions Safety light curtain/safety light grid SLC 420 SLG 420. Version 2.0. Content. 1. About this document

>Inductive and CATALOG. Capacitive Sensors

Operating instructions Safety light curtain SLC440. Version 2.0. Content. 1. About this document

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

In-process inspection: Inspector technology and concept

Through Hole Lamp Product Data Sheet LTW-42NDP4-HF Spec No.: DS Effective Date: 08/23/2011 LITE-ON DCC RELEASE

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Inductive sensor BI1.5-EG08K-Y1

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Digital Ratio Controller

Inductive sensor NI10-M18-Y1X-H1141

Transcription:

Safety Light Curtains

Dear Customer, the experience gained during these years of activity is closely related to the world of industry, brought us almost naturally as a manufacturer to develop safety produfcts for industry. So we decided to put our experience in designing and manufacturing of technologically advanced safety barriers ensuring maximum safety to millions of people who is in extremely hazardous conditions or in close contact with the equipment every day. I am also pleased by the fact that I am surrounded by a team staff who shares with me the same enthusiasm and inspiration needed to ensure total quality of the products and services, fully made in Italy. During all production cycle each barrier produced is exposed to strong test run and quality control where the materials conform to standards of European directive.. My greatest satisfaction is that many of you are choosing Red Beam high-tech applications thus emphasizing our reliability, flexibility and willingness to answer. Thanks to everyone who has already adapted to the brand Red Beam in manufacturing and to future consumers. Wishing good work! Director S. Amato

Resolution Models Composition product code PREFIX WORKING RANGE VERSION SAFETY LEVEL USEFUL HEIGHT AND RESOLUTION HTB + ( ) (L) (R) (3) + + + ( ) (5) how in table ( ) 0,1-5 mt (L) 0,3-17 mt (R) ) version basic ( ) version avanced (3) level 2 (5) level 4 USEFUL HEIGHT (mm) RESOLUTION (mm) 14 20 30 35 40 50 150 1514 1520 1530 1535 1540 1550 300 3014 3020 3030 3035 3040 3050 450 4514 4520 4530 4535 4540 4550 600 6014 6020 6030 6035 6040 6050 750 7514 7520 7530 7535 7540 7550 900 9014 9020 9030 9035 9040 9050 1050 10530 10535 10540 15050 1200 12030 12035 12040 12050 1350 13530 13535 13540 13550 1500 15030 15035 15040 15050 2 Red Beam

Models Multibeams Composition product code PREFIX WORKING RANGE VERSION SAFETY LEVEL USEFUL HEIGHT AND RESOLUTION HTB (S) (M) (3) + (L) + ( ) + (5) + how in table (U) (V) (S) 0,1-5 mt (L) 0,1-20 mt (U) 0,3-60 mt (M) ) version basic ( ) version avanced (V) vers. muting L-T-Y (3) level 2 (5) level 4 USEFUL HEIGHT (mm) RESOLUTION (beams) 1 2 3 4 80 0801 160 1601 - - - 300-3002 - - 450-4502 4503-600 - - 6003-750 - - 7503 7504 900 - - 9003 9004 1050 - - 10503 10504 1200 - - 12003 12004 1350 - - 13503 13504 1500 - - - 15004 1650 - - - 16504 1800 - - - 18004 1950 - - - 19504 Red Beam 3

Who we are Hecto Systems HECTOSYSTEMS is located in Turin, completely with Italian capital and for many years engaged in designing and manufacturing of electronic products. Hectosystems enters the safety world with high precision sensors measurement and applications and with ultrasound and infrared technologies. Since 2000 the company is specializing in safety so decides to invest in the design and manufacture of optoelectronic safety equipment and launches high-tech safety barriers with mark Red Beam. HECTOSYSTEMS accumulates own experience paying particular attention to safety in the workplace according to EEC Directive 8, the Law 626/94. The objectives of this directive are aimed to systematic identification of work risks, their elimination, prevention and deterrence before they produce undesirable effects. In these years dedicated to the development of safety barriers, the company is established in the Italian and international market, offering consumers in the short terms of supply premium quality, 100% MADE IN ITALY, targeted solutions and competitive prices. The aspect of workplace safety is fully covered by the safety barrier Red Beam. 4 Red Beam

Index SAFETY SISTEMS Reciever 7 Emitter 7 SAFETY STANDARD Risk assessement 8 SIL 8 Safety category 9 Safety distance 9 MAIN PROPERTIES Safety category 10 Resolution 10 Working range 11 Useful height 11 Response time 11 PRODUCTS RANGE Line Basic 12 Line Advanced 12 Operation mode 12 Function muting 13 Function blanking 13 Function override 13 Function EDM 13 Line Master & Slave 14 Line V 15 Available configurations 16 Line M 18 DATA SHEET Line Basic 20 Line Advanced 22 Line Multibeam 24 ACCESSORIES Laser pointer 30 Relay 31 Power switch 32 Cables 32 Supporting brackets 33 Mirrors & Columns 34 CERTIFICATES Red Beam 5

Safety sistems Photoelectric barriers immediately recognizable by its characteristic yellow color as safety instruments in any environment where they are installed. Safety system Red Beam creates a safe two-dimensional infrared area which makes it particularly suitable to the conditions in critical areas of industrial production, where people work closely with all faster and more powerful equipment such as presses, robotic lines and many others. Red Beam is designed to protect the operator having access to the danger zone, where the danger comes from the working moving equipment. It can also be applied in circumstances where the necessary control over the process (painting), or by simply counting the steps (storage). The introduction of object in the workspace of the barrier leads to interruption of dialogue of individual elements of the system that immediately involves a safety relay, which blocks operating equipment and runs connected acustic and visible hazard warning systems to completely eliminate state of danger. Integral safety system Read Beam works on microprocessor technology, providing complete diagnostic of dangerous situations with a detailed analysis of the problem. Today Red Beam is one of the most advanced System on the market for its flexibility and its advanced properties. 6 Red Beam

Safety System Red Beam consists mainly of two elements: emitter and receiver with one or more infrared beams that are synchronized with each other creating an invisible controlling barrier. The emitter sends to receiver unit photoelectric beams. Emitter The emitter has a series of elements throughout the length, from which emanates infrared beams; the number of these beams varies and is determined by the resolution of the barrier, which is supplied with the device CPU, which performs all the functions of monitoring and control of the barrier. Any anomaly of the functioning of the receiver is blocked for its response time of each particular model. Receiver The receiver is a clever element and it needs to take of arrival of infrared beams and it is made from the photosensitive elements with the same number as that of the emitter. All operations and control system are implemented by unit CPU of receiver. The receiver and emitter communicate with each other by infrared beams. Light indicator provides information about status of the barrier and the equalization. Except the interruption of the beam, just the slightest anomaly functioning to block receiver during working device, stopping the work of equipment there barrier has been installed. Before each cyclical scanning receiver controls that ambient conditions would not affect the state of their own photosensitive elements. Red Beam 7

Safety standard Risk assessment Standards EN1050 offers a systematic procedure for risk assessment, to the selection and application of safety systems most adapted to reduce it or completely eliminates it. Risk assessment is is divided into 4 phases: Risk assessment to establish the safety category: S injury severity - S1 lung damage (usually reversible) - S2 severe damage (usually non reversible) or death. F frequency / duration of exposure risk - F1 from rare to fairly frequent and / or short time exposure to risk - F2from frequent to prolonged and / or long time exposure to risk. P possibility to avoid the danger - P1 possible in special conditions (escape or interference by third parties). - P2 almost impossible (the phenomenon manifests it self quickly). SIL (Integrity Level Safety) a new standard acting in to force and obliging constructors to provide the safety level of photosensitive protection devices on board of potentially dangerous equipment. Barriers Red Beam ensure adherence to these standards. UNI EN ISO 13849-1:2007 and corresponds : ISO 13849-1:2006 PLd for safety level 2 and ISO 13849-1:2006 PLe for safety level 4 Establishing the work limits of equipment It consists in evaluating all allowed mode of working taking into account the level of training, experience and habits of the user. Categories S1 B 1 2 3 4 Identification of dangerous phenomenons It consists to create a list of all risks and hazardous elements (mechanical, electrical, chemical, etc.), all hazardous situations (manual load, access to equipment, etc..) and all situations that are able to provoke the harm ( failure or abnormality of equipment) Start risk assessment S2 F1 F2 P1 P2 P1 P2 Risk estimation Excessive measure It is based on three factors: severity of injury (reversible, irreversible, fatal), frequency and duration of exposure to risk and the Category is applicable if only using additional safety measures possibility of avoiding danger. Category suitable Residual risk assessment It analyzes the suitability of measures taken to ensure the safety. 8 Red Beam

Safety Categories Safety barriers Red Beam can be 2 or 4 categories. See the table below shows the main differences between two categories Requirements applicable System Operation Description of system operation Minimum requirements (EN 954-1) SAFETY CATEGORY 2 SAFETY CATEGORY 4 The requirements of category B. Apply safe components and safety principles. Safety function is detected in the corresponding intervals control system equipment. The periodic repetition of failures account may trigger the failure of safety functions during the interval between inspections. Failure of the safety features is revealed during the inspection. Potentially dangerous movements are controlled by terminal safety restrictor. Periodic monitoring of safety features is implemented at next startup of equipment or during a new cycle. During management the safety function is controlled. Failure of the safety features is diagnosed at the next check 2 inputs with PO 2 outputs: one for operation and second for signaling Cycle interaction (recommended) VPeriodic monitoring The requirements of category B. Apply safe components and safety principles. Parts related to safety are designed in such mode that : A single failure in one of these parts does not trigger a loss of safety function Single failure revealed before or during the subsequent query safety features. If it can damage the unit, the safety function will be supported. Breakdowns are diagnosed for a short time to avoid loss of safety function. Redundancy integrated in the system. Any failure will not lead to loss of safety function. Redundancy at the entrance - two channels with positive inputs emanating from the safety equipment so that it is possible to determine the displacement of the contact. Reservation at the entrance - 2 contactor. Monitoring of the adductor (cycle interaction). Protection against short circuit at the input of safety equipment. 2 channel input with PO Circuit redundancy (input and output) Cycle feedback Cycle self monitoring Short circuit protection (input) Safety Distance To select a suitable model, it is necessary to determine the height of the area which must be protected, identify the model or the type of protection, either in length once more than necessary. If the required height greater than that of models presented in the catalog, you need to use a system with two units of government. In this case you need to mount the receiver and emitter alternately with one and other. Distance protection barrier of the dangerous zone is determined by taking into account several factors, as shown in the following table. formula for European calculating K x T + C K - Constant in mm/sec (200 mm/sec) T - Total time response of barrier in sec.+ machine arrest time C - Additional distance in mm expressed in mm for application in Europe (see pr EN 999 ) formula for North American calculating K x (Ts+Tr) + Dpf K - Constant in inch/sec (63 inch/sec) Ts - Total time response of barrier + machine arrest time Tr - Response time of barrier Dpf - Additional distance (factor of radvised penetration depth : 3,1 inch) expressed in inch for application in USA (see OSHA 19 19.217) Red Beam 9

Main Properties Photoelectric safety barriers is photosensitive equipment consisting of a emitter, which emits one or more beams taken by receiver, thus creating intangible controlled area. Main properties are: Safety Category Risk assessment in different equipment or different pieces of equipment can detect different risk levels. You must install the safety level that proportional to risk. The Act EN954 defines a category of part related to safety according to the following parameters: Severity of injury (reversible, irreversible, fatal). Frequency and duration of exposure to danger. Ability to avoid danger. According to European standards CEI EN 61496 1-2, safety barrier can be of 2 or 4 category. Resolution Resolution of the photoelectric barrier is minimum size that subject should be in order to from controlled area it certainly launched the protective equipment and as a consequence should stop dangerous movement of equipment. Various optical resolution allows to adapt protection of body parts that are in dangerous zone. Thus it is possible to create a protected area for finger, but if you increase resolution also limbs will be protected up to body protection in the short and long distances using a wall mirror columns. Finger protection Hand protection Limb protection Body protection 10 Red Beam

Working Range Working range is the maximum distance that can be between emitter and receiver. Safety Barriers Red Beam can be as with short and long range in order to prevent access to dangerous zone of different sizes. Barriers with long-range designed for perimeter protection of large size with multiple parties access. Such protection is supported using one or more mirrors. Using mirrors it needs consider absorbing factor that they possess and it varies from 10% to 25%. Useful Height Useful height is the height controlled by barrier. If it is horizontal this parameter indicates the depth of protected area. Response time is the time spent by barrier to sending an alarm after scanning protected area. Useful height Response Time Resolution 14 20 30 35 40 50 150 10,2 10,2 6,2 6,2 5,2 4,2 300 18,2 18,2 10,2 10,2 7,7 6,2 450 26,2 26,2 14,2 14,2 10,2 8,2 600 34,2 34,2 18,2 18,2 13,2 10,2 750 42,2 42,2 22,2 22,2 15,7 12,2 900 50,2 50,2 26,2 26,2 18,2 14,2 1050 30,2 30,2 21,2 16,2 1200 34,2 34,2 23,7 18,2 1350 38,2 38,2 26,2 20,2 1500 42,2 42,2 29,2 22,2 Response time of barrier depends on its height and resolution. In the above table there are different response time depending on height and resolution. All multi beam safety barriers models have response time less than or equal to 50 msec. height total useful height resolution work range 37 47,5 Red Beam 11

Products Range As above mentioned safety barriers Red Beam can be of 2 or 4 safety category. Company offers two lines of products: line Basic and line Advanced for more for more exigent application. Line Basic Safety barriers Red Beam Basic have integrated CPU with relay output 1A 24 Vcc or 0 Vcc on request normally open contact. Above mentioned barriers are equipped with self-restart function in order to make easy alignment system. Line Advanced Safety Barriers Red Beam Advanced have an integrated control panel with access to relay in 1A with one normally closed contact and with one clean contact on output. Barriers Advanced have programmable reset function, which can be manual, semi-automatic or automatic. The control unit located directly at the barrier consists of an alphanumeric display, a graded scale of light, LED alignment and key programming. This type of barrier has integrated functions muting and blanking. Operation Modes During manual restart is activated relay inside of barrier by external buttons. During semiautomatic restart is activated relay inside of barrier when you turn on barrier manually after that all subsequent cycles of rebooting are automatically activated. During automatic restart relay inside of barrier is activated automatically without need of external commands. 12 Red Beam

Function Muting Function Muting is a temporary, automatic disabling light barrier protection, carried out in conditions of safety in accordance with working cycle of equipment. This function is necessary when during normal automatic cycle it needs intersection of some parts of equipment or material being treated without causing blocking of the equipment. This function is not available at line Basic. Functione Override Override function is intended to allow remove material that is in protected area. This may occur because of equipment stop when crossing material through the protected area. Two signals override can be activated by an appropriate switch which provides the required two-level, or with the pulse which activates the state level override. This feature is available only for models T, L, I. FunctionBlanking Blanking function suppresses action of or more beams of light curtains. There are fixed and floating blanking. FIXED blanking is used in cases where you need to install a light curtain of serving a fixed part of any equipment. FLOATING blanking is used in cases where you need to install a light curtain on the protruding part of any equipment, despite the fact that this part can move longitudinally within the protected area. This can be a governing body of any unit machine, to which access can be achieved no other way than through a light curtain (if the functional safety is not provided with another arrangement of a light curtain). The condition for activate the light curtain (turn off the equipment) is the intersection of more beams than the specified configuration of the light curtain. Function FeedBack (EDM) Function feedbek (more known as EDM) aims to monitor the state of external contacts, circuit breakers to which is connected the barrier thus preventing by blocking the system that one or more contact are jammed. This function is not available at line Basic. LINE ADVANVCED LINE BASIC MUTING: Light signal that indicates if function muting / blanking is active or no and helps to align barrier BREAK: indicates if there are interrupt beams or if barrier is in normal ambient conditions SAFE: it is radiant if alimentation of receiver is correct F1 - F2: function keys, access by password GRADED LIGHT SCALE: indicates areas where beams interrupt or state of beams during function of barrier Alphanumeric display: with other signals indicates the state of barrier Red Beam 13

Line Master & Slave This function is apply to line Basic or Advanced in any model, combines by cable length not exceeding 30 cm, 2 barrier thus articulated. Choosing an appropriate model that can be divided at any point thus forming two components: Master, containing CPU and first series of beams; Slave takes remaining beams. Total number of beams will not be lower or higher than the base model chosen. Useful when you are interested in both horizontal and vertical protection to prevent the operator to approach the danger zone. 14 Red Beam

Line V Barriers line V are safety equipment that create two-dimensional area for body protection in the work area. Intersection of controlled activates barrier by stopping dangerous movement of equipment. All models V belong to safety category 4. These barriers have working range of 0,1-3,0 m These models are applicable to all systems, palletizing, packing and packaging in general. Table below shows different combinations of protection. Height 1 beam 2 beams 3 beams 4 beams 5 beams 160 mm 300 mm 450 mm 600 mm 750 mm 900 mm 1050 mm 1200 mm 1350 mm 1500 mm 1650 mm 1800 mm 1950 mm TECHNICAL PROPERTIES Operation mode: automatic Power switch: 24 Vdc+-20% Output: 2 transistor PNP (OSSD) -24Vcc IC Max 1A DC-30 V protected in current Absorption: 0,4A max Temperature operation at: -10 +60 C Level protection: IP 65 Response time: HTBV5<30ms Sensor s time response: activation between first sensor and following must happen in 4 sec max and conclude in moment when first sensor becomes free Inputs: Muting, Override, Test and Feedback Outputs: state and signal pilotage Muting Time Muting: 30 or 90 programmable directly on barriers Available configurations: TX, TI, LX, LI, I Red Beam 15

Available Configurations Model T with intersecting beams: The intersection point must be inside protected area to prevent access of operator. The beam s intersection protects area as in input and output (bidirectional). Model L with intersecting beams: Two sensors are located inside protected area so that operator could not catch them without interrupting first beams of the barrier. They serve to open output of an object or even better pallets. Muting is activated following a break in both photocells. Model T with parallel and serial beams : Activation occurs with interception of one or two pairs of beams. Both sides are active 2 beams in such way as to ensure area protection of input and output objects (bidirectional). Model L with parallel and serial beams : Two sensors are located inside protected area so that operator could not catch them without interrupting first beams of the barrier. They serve to open output of an object or even better pallets. Muting is activated following a break in both photocells. 16 Red Beam

Model I with beams: For model supplied without arms, version I lets to connect 2 or 4 single photocells posted according to need apply. Correct functioning of the safety barrier is entrusted to the competence of installers. Version with 2 intersecting photocells Version with 2 parallel photocells Version with 4 intersecting photocells Version with 4 parallel photocells Red Beam 17

Line M Barriers line M are safety devices which create two-dimensional area for body protection in work area.intersection of controlled area leads barrier in action with following stopping dangerous movement of equipment. All models of line M are of safety category 2 and 4. These barriers have three different working range (0,1-6,0 m 0,3-17,0 4,0-60,0 m m) which ensure protection of area depending on available sizes. Table below shows different combinations of protection. Height 1 beam 2 beams 3 beams 4 beams 5 beams 80 mm 300 mm 450 mm 600 mm 750 mm 900 mm 1050 mm 1200 mm 1350 mm 1500 mm 1650 mm 1800 mm 1950 mm TECHNICAL PROPERTIES System is equipped with outputs not in tension normally open (max 1A @ 30Vdc protected in current). There are two output so called OSSD for safety category 4 and one for models with safety category 2. Contacts are closed in conditions of normal operation of barrier. Operation mode: automatic Power switch: 24 Vdc+-20% Absorption: 0,4A max Temperature operation at: -10 +60 C Level protection: IP 65 Response time: HTBSM<30ms, HTBLM<30ms, HTBUM<30ms LASER POINTER Models of M line can be equipped with a laser pointer installed at top point of emitter. Laser with red beam allows more easy and simple alignment of barriers with long-range action. This function is provided on request. 18 Red Beam

PROPERTIES BASIC ADVANCED M V Integrated relay x Integrated relay with clean contact x x Transistor output PNP x Automatic start x x x x Semiautomatic start x Manual start x Diagnostic allignment scale x x x x Alphanumerical display x x Graduated light scale x x Function Keys x x Muting x x x Blanking x Optycal Syncronysm x x x x Override x Feedbeck x x LINE BASIC SERE M OPTICS BREAK: indicates if there are interrupted beams or if barrier is in normal ambient conditions MUTING: Light signal that indicates if function muting / blanking is active or no and helps to align barrier SAFE: it is radiant if alimentation of receiver is correct 37 Connector M 12 a 8 inch 47,5 Red Beam 19

Line Basic Technical data sheet Safety Category 2 Useful working range: HTBR3 : 0,1-5 mt HTBLR3 : 0,3-17 mt Response time: > 30ms Output: 1 output in tension normally open - 24 Vcc IC max 1A dc/30v protected in current Input: TEST Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M12 to 5 inch Restart: automatic Alignment diagnostic Indicator RESOLUTION 14 mm 20 mm 30 mm 35 mm 40 mm 50 mm WORKING RANGE 0,1-5,0 mt 0,3-17,0 mt USEFUL HEIGHT TOTAL NR. BEAMS HTBR3-1514 HTBLR3-1514 150 270 16 HTBR3-3014 HTBLR3-3014 310 430 32 HTBR3-4514 HTBLR3-4514 470 590 48 HTBR3-6014 HTBLR3-6014 630 750 64 HTBR3-7514 HTBLR3-7514 790 910 80 HTBR3-9014 HTBLR3-9014 950 1070 96 HTBR3-1520 HTBLR3-1520 150 270 16 HTBR3-3020 HTBLR3-3020 310 430 32 HTBR3-4520 HTBLR3-4520 470 590 48 HTBR3-6020 HTBLR3-6020 630 750 64 HTBR3-7520 HTBLR3-7520 790 910 80 HTBR3-9020 HTBLR3-9020 950 1070 96 HTBR3-1530 HTBLR3-1530 140 270 8 HTBR3-3030 HTBLR3-3030 300 430 16 HTBR3-4530 HTBLR3-4530 460 590 24 HTBR3-6030 HTBLR3-6030 620 750 32 HTBR3-7530 HTBLR3-7530 780 910 40 HTBR3-9030 HTBLR3-9030 940 1070 48 HTBR3-10530 HTBLR3-10530 1100 1230 56 HTBR3-12030 HTBLR3-12030 1260 1390 64 HTBR3-13530 HTBLR3-13530 1420 1550 72 HTBR3-15030 HTBLR3-15030 1580 1710 80 HTBR3-1535 HTBLR3-1535 140 270 8 HTBR3-3035 HRBLR3-3035 300 430 16 HTBR3-4535 HTBLR3-4535 460 590 24 HTBR3-6035 HTBLR3-6035 620 750 32 HTBR3-7535 HTBLR3-7535 780 910 40 HTBR3-9035 HTBLR3-9035 940 1070 48 HTBR3-10535 HTBLR3-10535 1100 1230 56 HTBR3-12035 HTBLR3-12035 1260 1390 64 HTBR3-13535 HTBLR3-13535 1420 1550 72 HTBR3-15035 HTBLR3-15035 1580 1710 80 HTBR3-1540 HTBLR3-1540 150 270 6 HTBR3-3040 HTBLR3-3040 300 430 11 HTBR3-4540 HTBLR3-4540 450 590 16 HTBR3-6040 HTBLR3-6040 630 750 22 HTBR3-7540 HTBLR3-7540 750 910 27 HTBR3-9040 HTBLR3-9040 930 1070 32 HTBR3-10540 HTBLR3-10540 1110 1230 38 HTBR3-12040 HTBLR3-12040 1260 1390 43 HTBR3-13540 HTBLR3-13540 1410 1550 48 HTBR3-15040 HTBLR3-15040 1590 1710 54 HTBR3-1550 HTBLR3-1550 120 270 4 HTBR3-3050 HTBLR3-3050 280 430 8 HTBR3-4550 HTBLR3-4550 440 590 12 HTBR3-6050 HTBLR3-6050 600 750 16 HTBR3-7550 HTBLR3-7550 760 910 20 HTBR3-9050 HTBLR3-9050 920 1070 24 HTBR3-10550 HTBLR3-10550 1080 1230 28 HTBR3-12050 HTBLR3-12050 1240 1390 32 HTBR3-13550 HTBLR3-13550 1400 1550 36 HTBR3-15050 HTBLR3-15050 1560 1710 40 20 Red Beam

RESOLUTION 14 mm 20 mm 30 mm 35 mm 40 mm 50 mm WORKING RANGE 0,1-5,0 mt 0,3-17,0 mt USEFUL HEIGHT TOTAL NR. BEAMS HTBR5-1514 HTBLR5-1514 150 270 16 HTBR5-3014 HTBLR5-3014 310 430 32 HTBR5-4514 HTBLR5-4514 470 590 48 HTBR5-6014 HTBLR5-6014 630 750 64 HTBR5-7514 HTBLR5-7514 790 910 80 HTBR5-9014 HTBLR5-9014 950 1070 96 HTBR5-1520 HTBLR5-1520 150 270 16 HTBR5-3020 HTBLR5-3020 310 430 32 HTBR5-4520 HTBLR5-4520 470 590 48 HTBR5-6020 HTBLR5-6020 630 750 64 HTBR5-7520 HTBLR5-7520 790 910 80 HTBR5-9020 HTBLR5-9020 950 1070 96 HTBR5-1530 HTBLR5-1530 140 270 8 HTBR5-3030 HTBLR5-3030 300 430 16 HTBR5-4530 HTBLR5-4530 460 590 24 HTBR5-6030 HTBLR5-6030 620 750 32 HTBR5-7530 HTBLR5-7530 780 910 40 HTBR5-9030 HTBLR5-9030 940 1070 48 HTBR5-10530 HTBLR5-10530 1100 1230 56 HTBR5-12030 HTBLR5-12030 1260 1390 64 HTBR5-13530 HTBLR5-13530 1420 1550 72 HTBR5-15030 HTBLR5-15030 1580 1710 80 HTBR5-1535 HTBLR5-1535 140 270 8 HRBR5-3035 HRBLR5-3035 300 430 16 HTBR5-4535 HTBLR5-4535 460 590 24 HTBR5-6035 HTBLR5-6035 620 750 32 HTBR5-7535 HTBLR5-7535 780 910 40 HTBR5-9035 HTBLR5-9035 940 1070 48 HTBR5-10535 HTBLR5-10535 1100 1230 56 HTBR5-12035 HTBLR5-12035 1260 1390 64 HTBR5-13535 HTBLR5-13535 1420 1550 72 HTBR5-15035 HTBLR5-15035 1580 1710 80 HTBR5-1540 HTBLR5-1540 150 270 6 HTBR5-3040 HTBLR5-3040 300 430 11 HTBR5-4540 HTBLR5-4540 450 590 16 HTBR5-6040 HTBLR5-6040 630 750 22 HTBR5-7540 HTBLR5-7540 750 910 27 HTBR5-9040 HTBLR5-9040 930 1070 32 HTBR5-10540 HTBLR5-10540 1110 1230 38 HTBR5-12040 HTBLR5-12040 1260 1390 43 HTBR5-13540 HTBLR5-13540 1410 1550 48 HTBR5-15040 HTBLR5-15040 1590 1710 54 HTBR5-1550 HTBLR5-1550 120 270 4 HTBR5-3050 HTBLR5-3050 280 430 8 HTBR5-4550 HTBLR5-4550 440 590 12 HTBR5-6050 HTBLR5-6050 600 750 16 HTBR5-7550 HTBLR5-7550 760 910 20 HTBR5-9050 HTBLR5-9050 920 1070 24 HTBR5-10550 HTBLR5-10550 1080 1230 28 HTBR5-12050 HTBLR5-12050 1240 1390 32 HTBR5-13550 HTBLR5-13550 1400 1550 36 HTBR5-15050 HTBLR5-15050 1560 1710 40 Safety Category 4 Useful working range: HTBR5 : 0,1-5 mt HTBLR5: 0,3-17 mt Response time: > 30ms Output: 2 outputs in tension normally open - IC max 1A dc/30v protected in current Input: TEST Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M12 to 5 inch Restart: automatic Alignment diagnostic Indicator Red Beam 21

Line Advanced Technical data sheet Safety Category 2 Useful working range: HTB3 : 0,1-5 mt HTBL3 : 0,3-17 mt Response time : > 30ms Output: 1 output in relay, not in tension NO - I max 1A dc/30v protected in current - FEEDBACK (EDM) Input: RESTART - MUTING - TEST Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M23 to 12 and 16 inch Restart: automatic, semiautomatic, manual Alignment diagnostic Indicator Function keys Alphanumerical display RESOLUTION 14 mm 20 mm 30 mm 35 mm 40 mm 50 mm WORKING RANGE 0,1-5,0 mt 0,3-17,0 mt HEIGHT USEFUL TOTAL NR. BEAMS HTB3-1514 HTBL3-1514 150 270 16 HTB3-3014 HTBL3-3014 310 430 32 HTB3-4514 HTBL3-4514 470 590 48 HTB3-6014 HTBL3-6014 630 750 64 HTB3-7514 HTBL3-7514 790 910 80 HTB3-9014 HTBL3-9014 950 1070 96 HTB3-1520 HTBL3-1520 150 270 16 HTB3-3020 HTBL3-3020 310 430 32 HTB3-4520 HTBL3-4520 470 590 48 HTB3-6020 HTBL3-6020 630 750 64 HTB3-7520 HTBL3-7520 790 910 80 HTB3-9020 HTBL3-9020 950 1070 96 HTB3-1530 HTBL3-1530 140 270 8 HTB3-3030 HTBL3-3030 300 430 16 HTB3-4530 HTBL3-4530 460 590 24 HTB3-6030 HTBL3-6030 620 750 32 HTB3-7530 HTBL3-7530 780 910 40 HTB3-9030 HTBL3-9030 940 1070 48 HTB3-10530 HTBL3-10530 1100 1230 56 HTB3-12030 HTBL3-12030 1260 1390 64 HTB3-13530 HTBL3-13530 1420 1550 72 HTB3-15030 HTBL3-15030 1580 1710 80 HTB3-1535 HTBL3-1535 140 270 8 HTB3-3035 HRBL3-3035 300 430 16 HTB3-4535 HTBL3-1536 460 590 24 HTB3-6035 HRBL3-3036 620 750 32 HTB3-7535 HTBL3-1537 780 910 40 HTB3-9035 HRBL3-3037 940 1070 48 HTB3-10535 HTBL3-1538 1100 1230 56 HTB3-12035 HRBL3-3038 1260 1390 64 HTB3-13535 HTBL3-1539 1420 1550 72 HTB3-15035 HRBL3-3039 1580 1710 80 HTB3-1540 HTBL3-1540 150 270 6 HTB3-3040 HTBL3-3040 300 430 11 HTB3-4540 HTBL3-4540 450 590 16 HTB3-6040 HTBL3-6040 630 750 22 HTB3-7540 HTBL3-7540 750 910 27 HTB3-9040 HTBL3-9040 930 1070 32 HTB3-10540 HTBL3-10540 1110 1230 38 HTB3-12040 HTBL3-12040 1260 1390 43 HTB3-13540 HTBL3-13540 1410 1550 48 HTB3-15040 HTBL3-15040 1590 1710 54 HTB3-1550 HTBL3-1550 120 270 4 HTB3-3050 HTBL3-3050 280 430 8 HTB3-4550 HTBL3-4550 440 590 12 HTB3-6050 HTBL3-6050 600 750 16 HTB3-7550 HTBL3-7550 760 910 20 HTB3-9050 HTBL3-9050 920 1070 24 HTB3-10550 HTBL3-10550 1080 1230 28 HTB3-12050 HTBL3-12050 1240 1390 32 HTB3-13550 HTBL3-13550 1400 1550 36 HTB3-15050 HTBL3-15050 1560 1710 40 22 Red Beam

RESOLUTION 14 mm 20 mm 30 mm 35 mm 40 mm 50 mm WORKING RANGE 0,1-5, 0 mt 0,3-17,0 mt USEFUL HEIGHT TOTAL NR. BEAMS HTB5-1514 HTBL5-1514 150 270 16 HTB5-3014 HTBL5-3014 310 430 32 HTB5-4514 HTBL5-4514 470 590 48 HTB5-6014 HTBL5-6014 630 750 64 HTB5-7514 HTBL5-7514 790 910 80 HTB5-9014 HTBL5-9014 950 1070 96 HTB5-1520 HTBL5-1520 150 270 16 HTB5-3020 HTBL5-3020 310 430 32 HTB5-4520 HTBL5-4520 470 590 48 HTB5-6020 HTBL5-6020 630 750 64 HTB5-7520 HTBL5-7520 790 910 80 HTB5-9020 HTBL5-9020 950 1070 96 HTB5-1530 HTBL5-1530 140 270 8 HTB5-3030 HTBL5-3030 300 430 16 HTB5-4530 HTBL5-4530 460 590 24 HTB5-6030 HTBL5-6030 620 750 32 HTB5-7530 HTBL5-7530 780 910 40 HTB5-9030 HTBL5-9030 940 1070 48 HTB5-10530 HTBL5-10530 1100 1230 56 HTB5-12030 HTBL5-12030 1260 1390 64 HTB5-13530 HTBL5-13530 1420 1550 72 HTB5-15030 HTBL5-15030 1580 1710 80 HTB5-1535 HTBL5-1535 140 270 8 HTB5-3035 HRBL5-3035 300 430 16 HTB5-4535 HTBL5-1536 460 590 24 HTB5-6035 HRBL5-3036 620 750 32 HTB5-7535 HTBL5-1537 780 910 40 HTB5-9035 HRBL5-3037 940 1070 48 HTB5-10535 HTBL5-1538 1100 1230 56 HTB5-12035 HRBL5-3038 1260 1390 64 HTB5-13535 HTBL5-1539 1420 1550 72 HTB5-15035 HRBL5-3039 1580 1710 80 HTB5-1540 HTBL5-1540 150 270 6 HTB5-3040 HTBL5-3040 300 430 11 HTB5-4540 HTBL5-4540 450 590 16 HTB5-6040 HTBL5-6040 630 750 22 HTB5-7540 HTBL5-7540 750 910 27 HTB5-9040 HTBL5-9040 930 1070 32 HTB5-10540 HTBL5-10540 1110 1230 38 HTB5-12040 HTBL5-12040 1260 1390 43 HTB5-13540 HTBL5-13540 1410 1550 48 HTB5-15040 HTBL5-15040 1590 1710 54 HTB5-1550 HTBL5-1550 120 270 4 HTB5-3050 HTBL5-3050 280 430 8 HTB5-4550 HTBL5-4550 440 590 12 HTB5-6050 HTBL5-6050 600 750 16 HTB5-7550 HTBL5-7550 760 910 20 HTB5-9050 HTBL5-9050 920 1070 24 HTB5-10550 HTBL5-10550 1080 1230 28 HTB5-12050 HTBL5-12050 1240 1390 32 HTB5-13550 HTBL5-13550 1400 1550 36 HTB3-15050 HTBL3-15050 1560 1710 40 Safety Category 4 Useful working range: HTB5 : 0,1-5 mt HTBL5: 0,3-17 mt Response time: > 30ms Output: 2 outputs in relay, not in tension NO - IC max 1A dc/30v protected in current - FEEDBACK (EDM) Input: RESTART - MUTING - TEST Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M23 to 12 and 16 inch Restart: automatic, semiautomatic, manual Alignment diagnostic Indicator Function keys Alphanumerical display Red Beam 23

Line Multibeam Technical data sheet Safety Category 2 Safety Category 4 Useful working range: HTBSM3: 0,2-5 mt Response time: > 30ms Output: 1 output in relay, not in tension NO - IC max 1A dc/30v protected in current Input: TEST - MUTING Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M12 to 5 end 8 inch Restart: automatic Alignment diagnostic Indicator Useful working range: HTBSM5 : 0,1-5 mt Response time: > 50ms Output: 2 outputs in relay, not in tension NO - IC max 1A dc/30v protected in current Input: TEST - MUTING Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M12 to 5 end 8 inch Restart: automatic Alignment diagnostic Indicator MODELLO USEFUL HEIGHT TOTAL NR. BEAMS MODELLO USEFUL HEIGHT TOTAL NR. BEAMS HTBSM3-0801 80 110 1 HTBSM3-3002 300 338 2 HTBSM3-4502 450 488 2 HTBSM3-4503 450 488 3 HTBSM3-6003 600 638 3 HTBSM3-7503 750 788 3 HTBSM3-9003 900 938 3 HTBSM3-10503 1050 1088 3 HTBSM3-12003 1200 1238 3 HTBSM3-13503 1350 1388 3 HTBSM3-7504 750 788 4 HTBSM3-9004 900 938 4 HTBSM3-10504 1050 1088 4 HTBSM3-12004 1200 1238 4 HTBSM3-13504 1350 1388 4 HTBSM3-15004 1500 1538 4 HTBSM3-16504 1650 1688 4 HTBSM3-18004 1800 1838 4 HTBSM3-19504 1950 1988 4 HTBSM3-7505 750 788 5 HTBSM3-9005 900 938 5 HTBSM3-10505 1050 1088 5 HTBSM3-12005 1200 1238 5 HTBSM3-13505 1350 1388 5 HTBSM3-15005 1500 1538 5 HTBSM3-16505 1650 1688 5 HTBSM3-18005 1800 1838 5 HTBSM3-19505 1950 1988 5 HTBSM5-0801 80 110 1 HTBSM5-3002 300 338 2 HTBSM5-4502 450 488 2 HTBSM5-4503 450 488 3 HTBSM5-6003 600 638 3 HTBSM5-7503 750 788 3 HTBSM5-9003 900 938 3 HTBSM5-10503 1050 1088 3 HTBSM5-12003 1200 1238 3 HTBSM5-13503 1350 1388 3 HTBSM5-7504 750 788 4 HTBSM5-9004 900 938 4 HTBSM5-10504 1050 1088 4 HTBSM5-12004 1200 1238 4 HTBSM5-13504 1350 1388 4 HTBSM5-15004 1500 1538 4 HTBSM5-16504 1650 1688 4 HTBSM5-18004 1800 1838 4 HTBSM5-19504 1950 1988 4 HTBSM5-7505 750 788 5 HTBSM5-9005 900 938 5 HTBSM5-10505 1050 1088 5 HTBSM5-12005 1200 1238 5 HTBSM5-13505 1350 1388 5 HTBSM5-15005 1500 1538 5 HTBSM5-16505 1650 1688 5 HTBSM5-18005 1800 1838 5 HTBSM3-19505 1950 1988 5 24 Red Beam

MODELLO USEFUL HEIGHT TOTAL NR. BEAMS HTBS3-1601 160 190 1 HTBS3-3002 300 490 2 HTBS3-4502 450 640 2 HTBS3-4503 450 640 3 HTBS3-6003 600 790 3 HTBS3-7503 750 940 3 HTBS3-9003 900 1090 3 HTBS3-10503 1050 1240 3 HTBS3-12003 1200 1390 3 HTBS3-13503 1350 1540 3 HTBS3-7504 750 940 4 HTBS3-9004 900 1090 4 HTBS3-10504 1050 1240 4 HTBS3-12004 1200 1390 4 HTBS3-13504 1350 1540 4 HTBS3-15004 1500 1690 4 HTBS3-16504 1650 1840 4 HTBS3-18004 1800 1990 4 HTBS3-19504 1950 2140 4 Safety Category 2 Useful working range: HTBS3 : 0,1-5 mt Response time: > 50ms Output: 1 output in relay, not in tension NO - I max 1A dc/30v protected in current - FEEDBACK (EDM) Input: RESTART - MUTING - TEST Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M23 to 12 end 16 inch Restart: automatico, manuale, semiautomatico Alignment diagnostic Indicator Function keys Alphanumerical display MODELLO USEFUL HEIGHT TOTAL NR. BEAMS HTBS5-1601 160 190 1 HTBS5-3002 300 490 2 HTBS5-4502 450 640 2 HTBS5-4503 450 640 3 HTBS5-6003 600 790 3 HTBS5-7503 750 940 3 HTBS5-9003 900 1090 3 HTBS5-10503 1050 1240 3 HTBS5-12003 1200 1390 3 HTBS5-13503 1350 1540 3 HTBS5-7504 750 940 4 HTBS5-9004 900 1090 4 HTBS5-10504 1050 1240 4 HTBS5-12004 1200 1390 4 HTBS5-13504 1350 1540 4 HTBS5-15004 1500 1690 4 HTBS5-16504 1650 1840 4 HTBS5-18004 1800 1990 4 HTBS5-19504 1950 2140 4 Safety Category 4 Useful working range: HTBS5 : 0,1-5 mt Response time: > 50ms Output: 2 outputs in relay, not in tension, NO - I max 1A dc/30v protected in current - FEEDBACK (EDM) Input: RESTART - MUTING - TEST Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M23 to 12 end 16 inch Restart: automatic, semiautomatic, manual Alignment diagnostic Indicator Function keys Alphanumerical display Red Beam 25

Safety Category 2 Useful working range: HTBU3: 4-60 mt Response time: > 50ms Output: 1 output in relay not in tension NO - I max 1A dc/30v protected in current - FEEDBACK (EDM) Input: RESTART - MUTING - TEST Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M23 to 12 end 16 inch Restart: automatic, semiautomatic, manual Alignment diagnostic Indicator Function keys Alphanumerical display MODELLO USEFUL HEIGHT TOTAL NR. BEAMS HTBU3-1601 160 190 1 HTBU3-3002 300 490 2 HTBU3-4502 450 640 2 HTBU3-4503 450 640 3 HTBU3-6003 600 790 3 HTBU3-7503 750 940 3 HTBU3-9003 900 1090 3 HTBU3-10503 1050 1240 3 HTBU3-12003 1200 1390 3 HTBU3-13503 1350 1540 3 HTBU3-7504 750 940 4 HTBU3-9004 900 1090 4 HTBU3-10504 1050 1240 4 HTBU3-12004 1200 1390 4 HTBU3-13504 1350 1540 4 HTBU3-15004 1500 1690 4 HTBU3-16504 1650 1840 4 HTBU3-18004 1800 1990 4 HTBU3-19504 1950 2140 4 Safety Categorya 4 Useful working range: HTBU5 : 4-60 mt Response time: > 50ms Output: 2 output in relay non in tension NO - I max 1A dc/30v protected in current - FEEDBACK (EDM) Input: RESTART - MUTING - TEST Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M23 to 12 end 16 inch Restart: automatic, semiautomatic, manual Alignment diagnostic Indicator Function keys Alphanumerical display MODELLO USEFUL HEIGHT TOTAL NR. BEAMS HTBU5-1601 160 190 1 HTBU5-3002 300 490 2 HTBU5-4502 450 640 2 HTBU5-4503 450 640 3 HTBU5-6003 600 790 3 HTBU5-7503 750 940 3 HTBU5-9003 900 1090 3 HTBU5-10503 1050 1240 3 HTBU5-12003 1200 1390 3 HTBU5-13503 1350 1540 3 HTBU5-7504 750 940 4 HTBU5-9004 900 1090 4 HTBU5-10504 1050 1240 4 HTBU5-12004 1200 1390 4 HTBU5-13504 1350 1540 4 HTBU5-15004 1500 1690 4 HTBU5-16504 1650 1840 4 HTBU5-18004 1800 1990 4 HTBU5-19504 1950 2140 4 26 Red Beam

Safety Category 2 Useful working range: HTBLM3: 0,3-17 mt TResponse time: > 30ms Output: 1 output in relay, not in tension, NO - 24 Vcc IC max 1A dc/30v protected in current Input: TEST - MUTING Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M12 to 5 end 8 inch Restart: automatic Alignment diagnostic Indicator Safety Category 4 Useful working range: HTBLM5 : 0,3-17 mt Response time: > 30ms Output: 2 outputs in relay not tension, NO - 24 Vcc IC max 1A dc/30v protected in current Input: TEST - MUTING Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M12 to 5 end 8 inch Restart: automatic Alignment diagnostic Indicator MODELLO USEFUL HEIGHT TOTAL NR. BEAMS MODELLO USEFUL HEIGHT TOTAL NR. BEAMS HTBLM3-0801 80 110 1 HTBLM3-3002 300 338 2 HTBLM3-4502 450 488 2 HTBLM3-4503 450 488 3 HTBLM3-6003 600 638 3 HTBLM3-7503 750 788 3 HTBLM3-9003 900 938 3 HTBLM3-10503 1050 1088 3 HTBLM3-12003 1200 1238 3 HTBLM3-13503 1350 1388 3 HTBLM3-7504 750 788 4 HTBLM3-9004 900 938 4 HTBLM3-10504 1050 1088 4 HTBLM3-12004 1200 1238 4 HTBLM3-13504 1350 1388 4 HTBLM3-15004 1500 1538 4 HTBLM3-16504 1650 1688 4 HTBLM3-18004 1800 1838 4 HTBLM3-19504 1950 1988 4 HTBLM3-7505 750 788 5 HTBLM3-9005 900 938 5 HTBLM3-10505 1050 1088 5 HTBLM3-12005 1200 1238 5 HTBLM3-13505 1350 1388 5 HTBLM3-15005 1500 1538 5 HTBLM3-16505 1650 1688 5 HTBLM3-18005 1800 1838 5 HTBLM3-19505 1950 1988 5 HTBLM5-0801 80 110 1 HTBLM5-3002 300 338 2 HTBLM5-4502 450 488 2 HTBLM5-4503 450 488 3 HTBLM5-6003 600 638 3 HTBLM5-7503 750 788 3 HTBLM5-9003 900 938 3 HTBLM5-10503 1050 1088 3 HTBLM5-12003 1200 1238 3 HTBLM5-13503 1350 1388 3 HTBLM5-7504 750 788 4 HTBLM5-9004 900 938 4 HTBLM5-10504 1050 1088 4 HTBLM5-12004 1200 1238 4 HTBLM5-13504 1350 1388 4 HTBLM5-15004 1500 1538 4 HTBLM5-16504 1650 1688 4 HTBLM5-18004 1800 1838 4 HTBLM5-19504 1950 1988 4 HTBLM5-7505 750 788 5 HTBLM5-9005 900 938 5 HTBLM5-10505 1050 1088 5 HTBLM5-12005 1200 1238 5 HTBLM5-13505 1350 1388 5 HTBLM5-15005 1500 1538 5 HTBLM5-16505 1650 1688 5 HTBLM5-18005 1800 1838 5 HTBLM3-19505 1950 1988 5 Red Beam 27

Safety Category 2 Useful working range: HTBUM3: 4-60 mt Response time: > 50ms Output: 1 output in relay not in tension NO - IC max 1A dc/30v protected in current Input: TEST - MUTING Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M12 to 5 end 8 inch Restart: automatic Alignment diagnostic Indicator Safety Category 4 Useful working range: HTBUM5 : 0,3-3,0 mt Response time: > 50ms Output: 2 output in relay not in tension NO - 24 Vcc IC max 1A dc/30v protected in current Input: TEST - MUTING Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M12 to 5 end 8 inch Restart: automatic Alignment diagnostic Indicator MODELLO USEFUL HEIGHT TOTAL NR. BEAMS MODELLO USEFUL HEIGHT TOTAL NR. BEAMS HTBUM3-0801 80 110 1 HTBUM3-3002 300 338 2 HTBUM3-4502 450 488 2 HTBUM3-4503 450 488 3 HTBUM3-6003 600 638 3 HTBUM3-7503 750 788 3 HTBUM3-9003 900 938 3 HTBUM3-10503 1050 1088 3 HTBUM3-12003 1200 1238 3 HTBUM3-13503 1350 1388 3 HTBUM3-7504 750 788 4 HTBUM3-9004 900 938 4 HTBUM3-10504 1050 1088 4 HTBUM3-12004 1200 1238 4 HTBUM3-13504 1350 1388 4 HTBUM3-15004 1500 1538 4 HTBUM3-16504 1650 1688 4 HTBUM3-18004 1800 1838 4 HTBUM3-19504 1950 1988 4 HTBUM3-7505 750 788 5 HTBUM3-9005 900 938 5 HTBUM3-10505 1050 1088 5 HTBUM3-12005 1200 1238 5 HTBUM3-13505 1350 1388 5 HTBUM3-15005 1500 1538 5 HTBUM3-16505 1650 1688 5 HTBUM3-18005 1800 1838 5 HTBUM3-19505 1950 1988 5 HTBUM5-0801 80 110 1 HTBUM5-3002 300 338 2 HTBUM5-4502 450 488 2 HTBUM5-4503 450 488 3 HTBUM5-6003 600 638 3 HTBUM5-7503 750 788 3 HTBUM5-9003 900 938 3 HTBUM5-10503 1050 1088 3 HTBUM5-12003 1200 1238 3 HTBUM5-13503 1350 1388 3 HTBUM5-7504 750 788 4 HTBUM5-9004 900 938 4 HTBUM5-10504 1050 1088 4 HTBUM5-12004 1200 1238 4 HTBUM5-13504 1350 1388 4 HTBUM5-15004 1500 1538 4 HTBUM5-16504 1650 1688 4 HTBUM5-18004 1800 1838 4 HTBUM5-19504 1950 1988 4 HTBUM5-7505 750 788 5 HTBUM5-9005 900 938 5 HTBUM5-10505 1050 1088 5 HTBUM5-12005 1200 1238 5 HTBUM5-13505 1350 1388 5 HTBUM5-15005 1500 1538 5 HTBUM5-16505 1650 1688 5 HTBUM5-18005 1800 1838 5 HTBUM3-19505 1950 1988 5 28 Red Beam

Safety Category 4 Useful working range: HTBV5 : 0,1-3,0 mt Response time: > 30ms Output: 2 output PNP in relay in tension - IC max 1A dc/30v protected in current - FEEDBACK (EDM) - status output - output Muting lamp Input: RESTART - MUTING - TEST - OVERRIDE Power switch: + 24 Vdc ± 20% Absorption: 0,4 A max Operation temperature at: - 10 + 60 C Protection level: IP 65 Connection: round connector M23 to 16 end M 12 5 inch Restart: automatic, semiautomatic Alignment diagnostic Indicator Function keys Alphanumerical display MODELLO USEFUL HEIGHT TOTAL NR. BEAMS HTBV5-1601 160 190 1 HTBV5-3002 300 490 2 HTBV5-4502 450 640 2 HTBV5-4503 450 640 3 HTBV5-6003 600 790 3 HTBV5-7503 750 940 3 HTBV5-9003 900 1090 3 HTBV5-10503 1050 1240 3 HTBV5-12003 1200 1390 3 HTBV5-13503 1350 1540 3 HTBV5-7504 750 940 4 HTBV5-9004 900 1090 4 HTBV5-10504 1050 1240 4 HTBV5-12004 1200 1390 4 HTBV5-13504 1350 1540 4 HTBV5-15004 1500 1690 4 HTBV5-16504 1650 1840 4 HTBV5-18004 1800 1990 4 HTBV5-19504 1950 2140 4 HTBV5-7505 750 940 5 HTBV5-9005 900 1090 5 HTBV5-10505 1050 1240 5 HTBV5-12005 1200 1390 5 HTBV5-13505 1350 1540 5 HTBV5-15005 1500 1690 5 HTBV5-16505 1650 1840 5 HTBV5-18005 1800 1990 5 HTBV5-19505 1950 2140 5 Red Beam 29

Accessories Laser Pointer All models of barriers Red Beam Line Advanced can be equipped with a laser pointer installed at the upper receiver. This allows to optical align very quick and easy for barriers with working long-range. Visible to eye red laser is activated very simply by he keys F1 and F2, and at the end of the optical alignment it can be deactivated with same easiness. Technical data sheet ength of the emitted wave : 670 nm +_ 10% Optical output power: < 5 mw Absorption current : < 50 ma Divergence: < 2 mrad Diameter of emitted beam: 3 mm Optic: plastic lens Safety class (EN 60 82 5-1): 3R Class 3R: Laser with constant power below 5 mw, which emits radiation of wavelength range, including between 302,5 nm and 105 nm, while potentially dangerous to monitor the beam of light or their reflection, with or without optical instruments (the risk is reduced if laser has class 3B). Do not look directly the beam 30 Red Beam

Relay AC02 - AC03 - AC04 AC02 It is Ideal for connections between barrier Red Beam and actuating mechanism of machinery equipment. It has 3 N.O. and 3 N.C. contacts completely separated and one additional closed contact, used to connect to acoustic or visual-warning device. Input: 24 Vcc Output: 3 N.O, 3 N.C., Vdc independent Light indicator of correct function Voltage drop protection Safety category: 4 Level protection: IP20 Contact type: forced Mechanical life: 10.000.000 operations Absorption: 6 A Additional open output for external alarm AC03 It is Ideal for connections between barrier Red Beam and actuating mechanism of machinery equipment. It has 2 N.O. and 1 N.C. contacts completely separated and one additional closed contact, used to connect to acoustic or visual-warning device. Input: 24 Vcc Output: 2 N.O, 1 N.C., Vdc independent Light indicator of correct function Voltage drop protection Safety category: 4 Level protection: IP20 Contact type: forced Mechanical life: 10.000.000 operations Absorption: 6 A Additional open output for external alarm AC04 It is Ideal for connections between barrier Red Beam and actuating mechanism of machinery equipment. It has 2 N.O. and 1 N.C. contacts completely separated and one additional closed contact, used to connect to acoustic or visual-warning device. Input: 24 Vcc Output: 2 N.O, 1 N.C., Vdc independent, 2 single N.O. Light indicator of correct function Voltage drop protection Safety category: 4 Level protection: IP20 Contact type: forced Mechanical life: 10.000.000 operations Absorption: 6 A Additional open output for external alarm Red Beam 31

Power Switch It is designed for supply current all range of products Red Beam. It is equipped with protection against short voltage and voltage drop. Input: 230 Vac/ 110 Vac Output: 24 Vcc Light indicator of correct function Voltage drop protection Safety category: 4 Level protection: IP20 Power switch AL-01 is unit designed for supply each unit range Red Beam. Do not use it for other purposes. Can be supplied with two different input voltage, 110 or 230 watts to choise. Equipped with its own fuse. In case of of purchasing power switch, do not apply 24 Vdc output for connecting additional equipment. All types of ESPE (photosensitive protection equipment) of 4 type are supplied in the CC and should be equipped with own power switch unut, in accordance with standards EN 60742.. Cables For power supply of barriers Red Beam is used a shielded cable of various lengths, depending on customer needs. For barriers of Line Basic Line we offer a shielded cable with connector M12, 5 inches (right or with angle 90 degrees). For barriers of line M is designed cable M12, 8 inches, only for connection of receiver. For barriers of line Advanced we offer shielded cable with connector M23, 12 and 16 inches (right or with angle 90 degrees). 32 Red Beam

Supporting Brackets HTB5-ST17 is supporting bracket with pin king, it is supplied with barrier in kit of 4 pieces with bolts and nuts. HTB5-ST18 is supporting bracket model omega ; it lets to regulate barrier position with possibility of its inclination or rotation as receiver as emitter. These parts are optional and are supplied in kit of 4 pieces for each barrier couple. HTB5-ST19 is supporting bracket angle model, it lets to install barrier with angle 90 relatively to fixation point. These parts are optional and are supplied in kit of 4 pieces for each barrier couple. HTB5-ST21 is supporting bracket model L, it lets to fix single part of barrier of version L. it is supplied with barrier in kit of 2 pieces with bolts and nuts. HTB5-ST22 is supporting bracket model T ; it lets to fix single part of barrier of version T. it is supplied with barrier in kit of 2 pieces with bolts and nuts. Red Beam 33

Mirrors & Columns With use of mirrors reflecting the beam, it can create protected area of great dimension. Mirrors reflecting the beam with fixation on the surface and column-mirror (barriers) supporting brackets that are available in different heights, according to needs of users. There are used In order to create perimeter protection of great dimension providing protection by only 1 barrier more parties access. As a rule it is used in robotic production line, workers centers, presses, etc. The use of mirrors leads to a decrease of working range about 10-15% in each unit, to prevent this effect, barriers are usually applied with a little superior working range so as to optimize their function. Column-mirror (barriers) supporting brackets are made so to provide reliable and durable fixation on floor, their quick and simple install and precise optical alignment system. There are Ideally for protection in : stamping machines, cutting lines, robot stations, assembly lines, robots palletizing. Main properties: Basement can be in two type: A - Steel basement equipped with elastic clips for precise fixation to vertical axis. B - Steel basement for precise fixation directly to the floor. Aluminum column with angle regulable orientation. Easy assembly and disassembly of the barrier with ability to regulate the height of the first beam. Mirror length with fixation to wall 130 mm. Diametro colonna porta specchio/porta barriera 130 mm. Diameter column-mirror/barrier supporting bracket 130 mm. Color =yellow. A B 34 Red Beam

NOTE

NOTE