Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

Similar documents
Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Stratos Duo RGB. User Manual. Order code: EQLED371

Fusion 120 Zoom. User Manual. Order code: EQLED068

ORDER CODE: EQLED65 USER MANUAL

Spectra Batten (Order code: LEDJ95)

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Outdoor Stage PAR 12 4W Quad IR RGBW, 12 3W Quad IR UV LED PAR. user manual

PRO PAR HEX 12. User Manual

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

LED Thunder S-150 Code 1097

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

LED-BANK4 USER MANUAL. COLORbank 4

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

LED IP65 Slimline Par RGBWA +UV 7x12W

LED Pixel Track Pro ORDERCODE 42205

SquareLED - Aura Bar & Matrix Beam Light 100

Opti Tri White Par. User Instructions

LED-PAR200B USER MANUAL. COLORsplash 200B

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

EPAR QW. User Instructions

EPAR QA. User Instructions

Mini Stage Par 4 8W QCL RGBA/RGBW 25 /40 LED PAR. user manual

LED Spere Direct Control 30 ORDERCODE 41125

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

6X3W TRICOLOUR LEDS COMPACT PROJECTOR

LED Spot 300W. Please read this user manual before your operation

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

Outdoor Stage PAR 12 4 W Quad, 12 3 W UV IR LED PAR. user manual

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

1440/2880 HP RGB+WW+CW

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

LEDWash RGBW USER MANUAL

DMX LED light effect with 4 lenses

Magic Cube 3D. User manual. effect panel

LED Pot 12 1W RGBW LED PAR. user manual

9X9W LEDS BLINDER WITH LCD DISPLAY USER GUIDE December 2013 Version 1.12

WaferPar QUAD-W 7 CKU (US) / CKE (EU) USER MANUAL

CR-6 MIXER USER MANUAL ENGLISH. Order Code: MIXE01

Stage Quad LED Bundle RGBW / RGBWW LED lighting set. user manual

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do

192 Channel DMX Controller

Stage Wash 7x 10W LED Moving Head (RGBW)

Mini LED Pin Spot Light Model: PLS00571

Hex-color RGBAW+UV LED strip light

ARES. manual

LED Par 36 COB RGBW 12W, LED Par 46 COB RGBW 20W, LED Par 64 COB RGBW 60W, LED Par 56 COB RGBW 30W LED PAR. user manual

MH-X50+ LED spot moving head. user manual

4LEDKIT-DJ USER MANUAL. LED Tricolor 4-PAR Lighting Kit. Please read this manual carefully and proper take care of this manual.

ENGLISH Helios 200 COB Q4

STAGE SETTER-8. User Instructions. Elation Professional 4295 Charter Street Los Angeles Ca

MHL-1410WISPOT 14X 10W QUAD DMX 2.4GHZ

Flat LED Par Can Light

Octagon Theater CW/WW/A 20 6W LED PAR. user manual

Colour Control48 Order Code: Control48

User Instructions 3/10. A.D.J. Supply Europe B.V. Junostraat EW Kerkrade The Netherlands

Concert Series ORDERCODE D3470 ORDERCODE D3471 ORDERCODE D3472 D3470 D3471 D3472

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

www. eklights.com Guangzhou Liangyi Lighting Equipments Co.,Ltd. 37 Gongyedadao, Xinhua, Huadu, Guangzhou PC:510800

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

VRL PAR-1745 Par Lamp

American DJ. User Instructions. Model: Mega Bar 50RGB

User Manual. Xstatic Pro, Inc Essex Street - Brooklyn, NY Version 1.2

Venus W36 LED Moving Wash

ARENA PAR ZOOM. user manual. ELATION ARENA PAR ZOOM user manual

JunoScan MK-II LED scanner. user manual

DOTZ FLOOD. User Instructions

Introduction: The Dekker is part of American DJ s continuing pursuit for creating high quality affordable intelligent fixtures.

Quick Reference Guide

ELED PAR RGB ZOOM. User Instructions. Elation Professional 6122 S. Eastern Ave. Los Angeles CA

LED Pot 12 1W QCL RGB WW 15, LED Pot 12 1W QCL RGB WW 40 LED-PAR. user manual

VORTEX User Instructions

ARES XS. manual ARES XS

LED MOVING HEAD LedWash. 36 x 10w RGBW 4in1 Zooming USER MANUAL. Version 1.0 beta

USER MANUAL Table of Contents

Penta Pix. User Instructions

HEX16 Strip User Manual

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

LED Flood Panel 150 LED floodlight. user manual

USER MANUAL Table of Contents

MANUAL. ENGLISH NanoQ 19 Q4 IP Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

LED WASH LIGHT( 4 1) USER MANUAL

MANUAL ENGLISH Core Club Ordercode: D2314

Owner Handbook Neptune Tumbler. Owner Handbook. Neptune Tumbler

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

BROTHER, BROTHER & SONS

Stage Flood QCL 24x10W, Stage Flood Inst QCL 24x10W LED floodlight. user manual

TABLE OF CONTENTS INTRODUCTION

USER S MANUAL

Compact LED-Bar 4 TriPAR CLB4 LED lighting set. user manual

80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE April 2014 version

RevueLED 120 COB True White LED spotlight. user manual

Event Bar Q4. User Instructions

Transcription:

Spectra Flood Q40 Exterior Fixture User Manual Order code: LEDJ284-40 Version LEDJ284N - 15 Version

Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make sure that there is no damage caused during transportation. Should there be any damage, consult your dealer and do not use the equipment. To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual. Please note that damages caused by user modifications to this equipment are not subject to warranty. CAUTION! TAKE CARE USING THIS EQUIPMENT! HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!! IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment. Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution! Never remove warning or informative labels from the unit. Do not open the equipment and do not modify the unit. Do not connect this equipment to a dimmer pack. Do not switch the equipment on and off in short intervals, as this will reduce the system s life. Do not expose to flammable sources, liquids or gases. Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable. Make sure that the available mains supply voltage is between 100~240V AC, 50/60Hz. Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically. If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again. If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Pro Light dealer for service. Only use fuses of same type and rating. Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. This lighting fixture is for professional use only - it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls. Warning! Risk Group 2 LED product according to EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam. WARRANTY: One year from date of purchase. OPERATING DETERMINATIONS If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and/or property. www.prolight.co.uk Spectra Flood Q40 User Manual 2

Product overview & technical specifications Spectra Flood Q40 Equipped with 40 x 10W RGBW LEDs, the Q40 is suitable for illuminating large buildings, event spaces or stages. The unit utilises quad-colour LED technology to reproduce a wide colour spectrum from rich, primary colours through to subtle pastel tones across either a 40 or 15 beam with a flat, even field. Designed for rental and events, the Q40 features omega quick release brackets, PowerCON TRUE1 connectors for power input/output and also features both wired and wireless DMX by W-DMX Sweden. The slim profile of the fixture is ideally suited for loading into road trunks holding multiple units. 40 x 10W quad-colour LEDs (RGBW) Beam angle: 40 - LEDJ284 15 - LEDJ284N 40-8,054 Lux @ 2m (full on) 15-57,800 Lux @ 2m (full on) 3kHz refresh rate Wireless DMX control by W-DMX Sweden DMX channels: 4, 6 or 8 selectable Static colour, colour change, colour fade and master/slave modes Specifications Power consumption Power supply Dimensions Weight Order codes Spectra Flood Q40 410W 100~240V, 50/60Hz 340 x 540 x 190mm 12kg LEDJ284-40 Version LEDJ284N - 15 Version 0-100% dimming and variable strobe Supplied with installation bracket and quick release omega clamps 4 push button menu with LCD display PowerCON TRUE1 input/output IP rated 5-Pin XLR input/ output trailing connections Fan cooled 40 - Lux FULL ON R G B W 0m 1m 2m 3m 4m 5m 15 - Lux FULL ON R G B W 32200 6120 10800 2340 15900 231000 43700 76600 17400 117000 8054 1534 2688 586 3973 57800 10900 19100 4340 29300 3580 680 1200 260 1760 25740 4850 8505 1930 13000 2010 383 673 147 993 14500 2730 4790 1090 7310 IP54 0m 1m 2m 3m 4m 5m 40 15 1290 245 430 98.3 635 9250 1750 3060 695 4680 540mm 190mm 340mm www.prolight.co.uk Spectra Flood Q40 User Manual 3

Technical specifications 01 01 08 07 04 05 06 09 02 03 01 - Bracket tightening knobs 02 - LCD display 03 - Function buttons 04 - Wireless DMX antenna 05 - PowerCON TRUE1 input 06 - PowerCON TRUE1 output 07 - IP rated 5-Pin XLR trailing input 08 - IP rated 5-Pin XLR trailing output 09 - Fans In the box: 1 x fixture, 1 x power cable & 1 x user manual Underside mounting points: www.prolight.co.uk Spectra Flood Q40 User Manual 4

Operating instructions Main Menu Sub Menu Options/Values Description DMX Control Slave Mode Auto Mode Dimmer Program Settings Information Address 001-512 DMX Address Setting Channels W-DMX 4 (4 channel mode) 6 (6 channel mode) 8 (8 channel mode) ON OFF Red 000-255 Green 000-255 Blue 000-255 White 000-255 Show Curve Setting Backlight-T 01 02-14 Curves Dimmer Speed 10S 20S 30S 60S ON C[--] (Colour) - See page 6 for colours Flash [00-99] Speed [001-100] Flash [00-99] Linear Square Law Inv Square Law S-Curve Fast Smooth DMX Channel Setting Wireless DMX Setting Slave Mode Setting Auto Mode Manual Dimming Mode Built-in Programs Dimming Curves Setting Backlight Time Backlight-L 01-10 Backlight Brightness Factory Reset DMX Fail Temperature Software YES NO OFF Hold Factory Reset DMX Signal Failure Setting Fixture Temperature Software Version www.prolight.co.uk Spectra Flood Q40 User Manual 5

Operating instructions Colour macros: 0 Blackout 10 Lime Green 20 Steel Blue 30 Surprise Pink 1 Red 11 JAS Green 21 Half CT Blue 31 Fuchsuia Pink 2 Flame Red 12 Fern Green 22 Full CT Blue 32 Follies Pink 3 Deep Golden Amber 13 Moss Green 23 State Blue 33 Special Rose Pink 4 Millennium Gold 14 Primary Green 24 Double CT Blue 34 Pink 5 Gold Amber 15 Dark Green 25 Medium Blue 35 Moroccan Pink 6 Orange 16 Green 26 Just Blue 36 Warm White 7 Chrome Orange 17 Medium Blue/Green 27 Deep Blue 37 Cold White 8 Deep Amber 18 Light Blue 28 Blue 38 White 9 Spring Yellow 19 Lighter Blue 29 Congo Blue W-DMX settings: To enable W-DMX, press the MENU button and use the UP and DOWN buttons to select DMX Control. Press the UP and DOWN button and use the UP and DOWN buttons to select W-DMX. Now use the UP and DOWN buttons to select ON. Press the ENTER button to confirm the setting. The green LED to the left of the display will flash indicating it is searching for a signal. Now pair your fixture with your W-DMX transmitter. The green LED will become static once sucessfully paired. To disable W-DMX, press the MENU button and use the UP and DOWN buttons to select DMX Control. Press the UP and DOWN button and use the UP and DOWN buttons to select W-DMX. Now use the UP and DOWN buttons to select OFF. Press the ENTER button to confirm the setting. Alternatively when W-DMX is enabled press and hold the MENU button, the display will show W-DMX Lock Out. Once this is complete the W-DMX has been disabled. The green LED will go off to confirm W-DMX has been disabled. To exit out of any of the above options, press the MENU button. 4 channel mode: Channel Value Function 1 000-255 Red (0-100%) 2 000-255 Green (0-100%) 3 000-255 Blue (0-100%) 4 000-255 White (0-100%) 6 channel mode: Channel Value Function 1 000-255 Master dimmer (0-100%) 2 000-255 Red (0-100%) 3 000-255 Green (0-100%) 4 000-255 Blue (0-100%) 5 000-255 White (0-100%) 6 000-255 Strobe (slow-fast) www.prolight.co.uk Spectra Flood Q40 User Manual 6

Operating instructions 7 channel mode: Value CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 000 Master Red Green Blue White dimmer 001-018 (0-255) (0-255) (0-255) (0-255) (0-255) Program 1 No funtion No funtion No function Value Colour 000-010 Blackout 011-016 Red 017-022 Flame Red 023-028 Deep Golden Amber 029-034 Millennium Gold 035-040 Gold Amber 041-046 Orange 047-052 Chrome Orange 053-058 Deep Amber 059-064 Spring Yellow 065-070 Lime Green 071-076 JAS Green 077-082 Fern Green 083-088 Moss Green 089-094 Primary Green 095-100 Dark Green 101-106 Green 107-112 Medium Blue/Green 113-118 Light Blue 119-124 Lighter Blue 125-130 Steel Blue 131-136 Half CT Blue 137-142 Full CT Blue 143-148 State Blue 149-154 Double CT Blue 155-160 Medium Blue 161-166 Just Blue 167-172 Deep Blue 173-178 Blue 179-184 Congo Blue 185-190 Surprise Pink 191-196 Fuchsuia Pink 197-202 Follies Pink 203-208 Special Rose Pink 209-214 Pink 215-220 Moroccan Pink 221-226 Warm White 227-232 Cold White 233-255 White Strobe (0-255) www.prolight.co.uk Spectra Flood Q40 User Manual 7

Operating instructions 7 channel mode cont.: Value CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 019-037 Program 2 038-056 Program 3 057-075 Program 4 076-094 Program 5 095-113 Program 6 114-132 Master Program 7 Red Green Blue White 133-151 dimmer Program 8 (0-255) (0-255) (0-255) (0-255) 152-170 (0-255) Program 9 171-189 Program 10 190-208 Program 11 209-227 Program 12 228-246 Program 13 247-255 Program 14 Speed (slow-fast) Strobe (0-255) www.prolight.co.uk Spectra Flood Q40 User Manual 8

DMX setup Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture requires a start address from 1-512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the chain starts at 107. DMX 512: DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures (most controllers only have a data out terminal). DMX linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain. DATA cable (DMX cable) requirements (for DMX operation): This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output, see image below. Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers. Please quote: CABL10 2m CABL11 5m CABL12 10m Also remember that DMX cable must be daisy chained and cannot be split. www.prolight.co.uk Spectra Flood Q40 User Manual 9

DMX setup Notice: Be sure to follow the diagrams below when making your own cables. Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing. Grounding the shield could cause a short circuit and erratic behaviour. Special note: Line termination: When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour. Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89) Termination reduces signal transmission problems and interferance. it is always advisable to connect a DMX terminal, (resistance 120 Ohm 1/4 W) between pin 2 (DMX-) and pin 3 (DMX+) of the last fixture. 5-pin XLR DMX connectors: Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion. 5-pin XLR (female) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C 3-pin XLR (male) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) 3-pin XLR (female) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) 5-pin XLR (male) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C www.prolight.co.uk Spectra Flood Q40 User Manual 10

WEEE notice Correct Disposal of this Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. www.prolight.co.uk Spectra Flood Q40 User Manual 11

www.prolight.co.uk Spectra Flood Q40 User Manual 12