DOUBLING OF EAST USK BRANCH NEWPORT

Similar documents
Sunbury SUNBURY (23 3/4 MILES)

Fixed Signals - Rules 1 to 23

INTRODUCTION OF COLOUR LIGHT SIGNALS AND NEW SIGNAL BOX AT MAIDSTONE EAST. On SUNDAY, 8th APRIL, 1962

Withdrawn Document. Title of Rule Book SECTION N SINGLE LINE WORKING. Page Date Index

2 Layout and Use of Signals

Ground Frames and Shunters Releases

PRIVATE and not for Publication NOTICE No. S.2649 BRITISH RAILWAYS. (WESTERN REGION) (For the use of employees only) Notice to Trainmen, etc.

British Signalling What the driver sees

Kyneton KYNETON (40 MILES)

Block System Interface Requirements

BURNLEY GROUP OPERATING PROCEDURES

Network Safeworking Rules and Procedures

Uncontrolled When Printed Document comes into force on 05/12/2015 Supersedes GERT8000-HB2 Iss 1 on 05/12/2015

The Joys of Life Model Railway Club OPERATING THE RAILWAY. Not To Be Taken Away

(LONDON MIDLAND REGION) SPECIAL NOTICE 1855 G.

Transportation Engineering - II Dr. Rajat Rastogi Department of Civil Engineering Indian Institute of Technology - Roorkee

Fig. 2. Typical Point Lay-out.

This SOP is applicable to all WMATA personnel working on the Rail System, contractors performing the work and WMATA contractor escorts.

Transportation Engineering -II Dr. Rajat Rastogi Department of Civil Engineering Indian Institute of Technology - Roorkee

Withdrawn Document. SECTION F (Part ii) YOUR DUTIES IF YOU ARE ACTING AS A HANDSIGNALLER

Responding to Signals and Signs

SIGNALING PRACTICES ON PROTOTYPE AND MODEL RAILROADS

Lineside Signal Aspect and Indication Requirements

Simplified Signaling for Modelers

Lineside Signal Aspect Sequences

Signal Sighting. Withdrawn Document Uncontrolled When Printed. Railway Group Standard. Issue Two Date February 1996

VIDEO DOOR PHONE CAV-51M

The Netherlands. NS signals

RAILWAY INVESTIGATION REPORT R12D0063 UNPROTECTED OVERLAP OF AUTHORITY

Briefing Note Publication

CINEMA SIX Emergency and Safety Procedures

BBC Written Archives Centre. Information for Visiting Researchers

Where was the location of the incident?

User Instructions. 16 SCB Sync Station.

Collator series 300/400, 310B Spare parts list

Lineside Signals, Indicators and Layout of Signals

Brunswick Town Council Workshop with Rail Officials Town Council Chambers, Brunswick Town Hall Monday, October 30, 2017, 7:00-9:00 PM

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

HAND-FREE COLOR VIDEO DOORPHONE. Installation and Operation Manual

NMRA 2013 Peachtree Express Control Panel Editor - B

Lineside Signals, Indicators and Layout of Signals

Handbook 8. Handbook 8. IWA, COSS or PC blocking a line. GE/RT8000/HB8 Rule Book

VIDEO DOOR PHONE. Model No. APV-4PM

Running Signals ANSG 600. Applicability. Publication Requirement. Document Status NSW SMS. External Only October 2015.

Azatrax Model Railroad Track Signal Control - Single Track

Owners SW-LCD 2.0 Manual & Specifications

APPROVED for connection to Telecommunication systems specified in the instructions for use subject to the conditions set out in them.

ART 7 SERIES PROFESSIONAL ACTIVE SUBWOOFERS. a new generation of speakers is born and it s ready to rock audiences all over the world

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

(NORTH EASTERN AREA). PERMANENT WAY, SIGNAL ALTERATIONS and I NSTRUCTI 0 NS

SWISS TIMING Service catalogue FIS World Cup Ski Jumping / Ski Flying 2017/2018

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

DMX48. User s instruction manual. 24 Channel DMX controller

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

CR Signals Price List (N Gauge & General) April 2010

Dear Railway Modeller,

Aerial Cable Installation Best Practices

CFT2200. User Guide 0(18 6(/(&7 (17(5 92/80( &+$11(/ ( 6 6 $ * ( 6

User Guide. Centrex Recording Interface

Engineering Instruction


FD Trinitron Colour Television

Multi Room Audio Matrix Switcher

Layout Design For Signaling

IRT Eurocard. Type RWA RF Distribution Amplifier for 70 MHz IF signals

Layout Design For Signaling

Achat 115 Sub A active subwoofer. user manual

Caution. Hanging the Screen:

MP-7424 Football Scoreboard with MP5000 Console

SWISS TIMING Service catalogue FIS World Cup Ski Jumping Ladies 2017/2018

9216e. Installation and User Guide

SOUTHWESTERN BELL TELEPHONE COMPANY TARIFF F.C.C. NO. 73 1st Revised Page 9-1 Cancels Original Page 9-1

GK/GN0658. Guidance on Lineside Signal Aspect and Indication Requirements. Rail Industry Guidance Note for GK/RT0058

COLORtube EQ Controller

Long Range Ethernet Extender

Winter Wonderland Train Show

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Introduction and Definitions

Staatskapelle Weimar Orchestra of Germany Technical Addendum Page 1. Addendum to Contract

LINK-MI LM-WHD05B. Wireless HDMI AV Transmission System. User Manual

ISS New Audio & Visual installations Design and Physical install guidelines v1.5

USER INTERFACE TO THE BEAM INTERLOCK SYSTEM

Guidance on Lineside Signals, Indicators and Layout of Signals. Rail Industry Guidance Note for GK/RT0045

2. SUPERPATH Mbps Digital Service 2.1. General

J.D. BIRLA INSTITUTE DEPARTMENTS OF SCIENCE & COMMERCE

User Manual Color video door phone

3 Cleaning. 4 Technical data

Track Work Authority ANWT 306. Applicability. Publication Requirement. Document Status NSW SMS. External Only October 2015.

Operation Manual VMS 3.0 Video System

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

User Manual Wide Color Video Phone

Contents. 1. General Information. 2. Contents. 3. Operating Instruction. 4. Program update. 5. Trouble Shooting. 6. Specifications

SUPPORTING AND PROMOTING FOLK MUSIC, DANCE & STORYTELLING IN THE FOX VALLEY SINCE 1975

The LONDON MIDLAND and SCOTTISH RAILWAY

PREAMPLIFIER INTRODUCTION INSTRUCTIONS FOR USE. Thank you for purchasing the Musical Fidelity A3 CR remote control preamplifier.

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

CPH-10 SUBWOOFER OWNERS MANUAL

NETWORK RAIL Scotland. Route SC141. Craigendoran. and. Fort William. (Maintenance) Not to Scale. T.A.P.M.SC

Handbook 8. Issue 6. IWA, COSS or PC blocking a line. GERT8000-HB8 Rule Book. September 2017 Comes into force 02 December 2017

Transcription:

Private and not for Publication. Notice No. W.58. BRTSH RALWAYS (WESTE RN REGON.) DOUBLNG OF EAST USK BRANCH NEWPORT. Between the hours of 7.0 a.m. on SUNDAY, 28th SEPTEMBER, 952, and 5.0 p.m. on FRDAY, 3rd O CTOBER, 952, or unt il t he work is completed, new signal boxes, to be known as " Corporation Road" and" Uskmouth," also new ground frames, will be brought into use on the East Usk Branch, and double line will extend from East Usk Junction signal box to Uskmouth signal box. The line from East Usk Junction to Uskmouth will be the Up line. and the line from Uskmouth to East Usk Junction will be t he Down line. An Up Goods Loop will be brought into use on the Up side of the Up Main line at Corporation Road signal box. accom modating e ng ine. 85 2-ton wagons. and brake-van. The facing points in the Up Main line leading to loop will be worked electrically by the hand-generator system; the trailing catch point in the loop will be a spring point. A Down Goods Loop will be brought into use on the Down side of the Down Main line at Corporation Road signal box. accommodati ng engine. 5 2-ton wagons. and brakevan. The facin g points in the Down Main line leading to loop will be worked electrically by the hand-generator system; t he trailing catch point in the loop will be a spring point. SEE ATTACHED DAGRAM. EAST USK JU NCTON. The existing Up Branch to single lin e at the East Usk Ju nct ion end of the branch will be slued from a point near the 0 m. *m. p. to connect up with the new Up line. and from the same point a new Down line will be brought into use, con necting the single line with the existing Down Branch line; the existing single line will then become the Down Branch line. The trailing crossover road between the Up and Down Branch lines will be temporarily clipped and spiked out of use. The Down Branch Home signal and the Up Branch Ad vanced Starting for East Usk Junction. both on the same post, will be moved to a new position 65 yards farther from the signal box with no alteration n height or form. lettered "A" on diagram. The telephone at this signal will be moved at the same time. The existing Down Branch Distant signal for East Usk Junction will be taken out of use.

2 CORPORATON ROAD. The new sig nal box, to be known as.. Corporation Road.. Signal Box, will be situated at a point mile 7 chains on t he Up side of the Up Main line. The following new signals will be brought into use at Corporation Road Signal Box: Form. ndicated on diagram by letter Description. Position. from Signal Box. B. Up Main Home. Up side of Main line. Up,2 yards. 2. Up Main to Up Loop Ho me. (Telephone to signal box at this signa/.) C. Up Main nner Home. Up side of Main lin e. Up 334 yards. ~ 2. U P M a i n tot u b e Works Sidings nner Home. ~ 0. Up Loop to Up n ne r Home. Main Up side of Up Loop line. 334 yards. 2. Up Loop to Tube Works Sidings nner Home. (Telephone to signal box at this signal.).~ Sidings. Backing from Down Main to Down Main or Up Main. or Tu be Works Between Up and Down Main lines. 304 yards. ~ Nos.. 2. and 3 Sid ings Starting to Up Main or to Tube Works Sidings. Up side of Sidings. 278 yards. ~ or Backing from Up Main to Down Main, or Up Loop. Nos.. 2. and 3 Sidings. Up side of Up Main line. 222 yards.

3 Form. ndicated o n diagram by letter Description. Position. from Signal Box. Tube Works Sidings Starting to Up Main or Nos.. 2. and 3 Sidings. Down side of Tube Works Sidings. 5 yards. E Up Main Starting. Up side of Up Main line. 47 yards. Backing from Down Main to Up Main or Down Main. Between Up and D own Main li nes. 48 yards. Backing from Up Main to Down Main or Up Main. Up side of Up Main line. 0 yards. Backing from Down Mai n t o Down Loop. or Nos. and 2 Sidings or Lysaghts Outlet Sidi ngs. Do wn side of Down Main line elevated 5 feet on bridge girder. 8 yards. F ~ Up Mai n Advanced Starting. R. Down Main Home. 2. Down Main to Down Loop Home. 3. Down Main to Lysaghts nlet Sid ings Home. for Lysaghts nlet ground fra me. Up side of Up Main line. Down side of Down Main line. (Telephone to signal box at this signal.) 8 3 yards..002 yards.

4 Form. nd icated on diagram by letter Description. Position. from Signal Box. ~ U 5 V T W X Stop Lamp. Down side of Down Loop at trailing e nd of Down Mai n to Down Loo p poi nts. Down Main nner Home. Between Down Main & Down Loop. Down Loop ntermediate Between Down Home. Loop & No. Siding. (Telephone to signal box at this signa/.) Down Loop to Main nner Home. Down side o f Down Loop line. Down Sidings Starting. D own side of No.2 Siding. Lysaghts Outlet to Down Main Starting. Down side of Lysaghts Outlet Sidings. Down Main Starting. Do wn side of Down Main line. 763 yards. 99 yards. 272 yards. 20 yards. 272 yards. 99 yards. 248 yards.

5 ndicated on Form. diagram Description. Position. from by letter Signal Box. y Down Main Advanced Down side of 680 yards. Starting. Down Ma in line. New connections will be brought into use in accordance with the attached sketch. A new 3-lever ground frame, to be known as.. Lysaghts nlet Ground Frame," will be brought into use on the Down side of the Down Main line, near the faci ng end of the Down Main to Down Loop points, to operate a trailing crossover between the Up and Down Main lines, and a new faci ng connection from Down Main to Lysaghts Sid ings. This ground frame, which will be released by Annetts Key-controlled from Corporation Road signal box-will also operate the Down Main to Lysaghts Sidings Home signal, " R.. on sketch. Telephone communication with loud-soundi ng bell between Corporation Road signal box and t he ground frame and a telephone with loud-sounding bell connected to the Branch Selective Circuit will be provided. At the same time the existing -lever ground frame, known as.. Lysaghts nlet Ground Frame," will be taken out of use; also the Engineering Department Siding just beyond Lysaghts nlet, the points being spiked pending removal. USKMOUTH. The new signal box, to be known as.. Uskmouth.. signal box, will be si tuated at a point 2 miles 79 chains on the Down side of the Down Loop line. The following new Signals will be brought into use at Uskmouth Signal box: ndicated o n Form. diagram Description. Position. from by letter Signal Box. G Up Main Home. Up side of Up 79 yards. Main line.

6 Form. ndicated on diagram Description. Position. by letter from Signal Box. H Up Main nner Home Up side of Up 59 yards. Route ndicating Signal. Main (ne. To No. Sidi ng (Power Station). To No.2 Siding (Power Station). To No. 3 Sid ing (BAC. Spur). No. Siding Starti ng to Up Main. Between No. Siding an d Down Main at Trap Points. 3 yards. Backing from Down Loop to No. 3 Siding.. Between Down Loop & Down Main. 2 yards. J No.3 Siding Starting Down side of No. 9 yards. Route ndicating Signal. 3 Siding. To Down Main. To Down Loop. To BA C. Siding. K L No. 2 Siding to Down Between No. 2 2 yards. Main Starting. Siding & Crossover leading from No.3 Siding to Down Main. BAC. Siding to No. 3 Up side of BAC 9 yards. Siding Starting. Siding. M Down Main Starting. Between Down 40 yards. Main & Down Loop.

7 ndicated on Form. diagram Description. Position. by letter from Signal Box. ~, Stop Lamp. Down side of 40 yards. Down Loop at Down Loop Exit Trap Points N Down Main Ad vanced Down sid e of Starting. Down Main. 695 yards. New connections will be brought into use in accordance with the attached sketch. A new 2-lever ground frame, to be known as " Monsanto Ground Frame, " will be brought in to use on the Up side of t he Up Main line at the existing connection to Monsanto Siding. The ground frame will operate a trailing crossover betwee,n the Up and Down Main lines and a trailing connection in the Up Main line from the Siding. The ground frame wi ll be released by Annetts Key-controlled from Uskmouth signal box. Telephone communication with loud-sounding bell between the signal box and the ground frame and a telephone connected to the Branch Selective Circuit w ill be provided. At the same time the existing -lever ground frame known as " Monsanto Ground Frame" will be taken out of use. A new -lever ground frame, to be known as " British Aluminium Sidings South Ground Frame," will be brought into use on the Down side of the Down Main line near the exit from t he Down Loop. The ground frame wi ll work the connection from the Down Loop to Down Main and will be released by Annetts Key-controlled from Uskmouth signal box. Telephone communication with loud-sounding bell between the signal box and the ground frame will be provided. At the same time the existing -lever ground frame known as " British Aluminium Sidings Middle Ground Frame." will be taken out of use.

8 At the same time three new signals as shewn will be brought into use at the following ground frames: BRTSH ALUMNUM SDNGS NORTH GROUND FRAME. n dicated on Form. diagram Description. Position. from ground by letter frame. 0 54 yards. Down Main Home. Down side of Down Mai n line. THS SGNAL WLL NORMALLY STAND " OFF" with lever reverse, locking siding safety trap point open. Telephone communication with loud-sounding be ll between Uskmouth signal box and the ground frame and a t elephone with loudsounding bell, connected to the Branch Selective Circuit, will be provided. CHANNEL DRY DOCK GROUND FRAME. ndicated o n Form. diagram Description. Position. from ground by letter. frame. p Down Main Home. Down sid e of 60 yards. Down Mai n line. THS SGNAL WLL NORMALLY STAND.. OFF" With lever reverse, locking siding safety t rap point open. A telephone connected to the Branch Selective Circuit will be provided. EASTERN DRY DOCK GROU ND FRAME. ndicated on Form. diagram Description Position. from ground by letter frame. Q Down Main Home. Dow n si d e of 47 yards. D own Mai n li ne. THS SGNAL WLL NORMALLY STAND.. OFF" with lever reverse locking siding safety trap point open. A telephone connected to the Branch Selective Circuit will be provided.

9 The Branch will be worked by Permissive Block system in accordance with Section V of the Regulations for Train Signalling. the Btock Sections being as follows: East Usk Junction-Corporation Road. Corporation Road-Uskmouth. and all existing stop lamps and telephones throughout the Branch will be taken out of use. TELEPHONES. The Newport- Stoke Gifford Control Telephone Circuit will be extended to Corporation Road and Uskmouth Signal boxes. The existing East Usk Branch Telephone Circuit will be extended and selective telephones substituted for existing code ringing type, communicating with t he following places: East Usk Junction Signal box. East Usk Junction nspector's Office. Tube Works. Corporation Road signal box. Lysaghts Outlet. Lysaghts nlet ground frame. Eastern Dry Dock ground frame. Channel Dry Dock ground frame. British Aluminium Sidings North ground frame. Monsanto ground frame. Uskmouth signal. box. Two local code ringing telephone circuits will be provided at Corporation Road, communicati ng with the following places:. Corporation Road Signal box. Signal at exit from Up Loop. 40 wagon lengths from Up Loop exit. 60 wagon lengt hs from Up Loop exit. Trai ling catch point at entrance to Up Loop. Up Main Home Signal. 2. Corporation Road Signal box. Signal at exit from Down Loop. Trailing catch point at entrance to Down Loop. Down Main Home Signal.

T RACK 0 CRCU TS. The following track ci rcuits will be brought into use at Corporation Road signal box: Line. Up Mai n. Up Main. Down Main. - Track Ci rcuit in rear of: Up Homes (SOAT) Through Up Main Through Down Main to Up Loop Points to Down Loop Points (40T). (l it). Length of Track in yards. 200. 60. 25. - Position of Diamond Sign. On Up Homes. - - Signals locked e lectrically - Points Up Main to Down Main to Down when track circuit is Up Lopp Normal Loop Facing Point. occupied and Reverse. Normal and Reverse. - -- Whether BlockControlled. - - - - - - Whether V.O.L. switch - - - provided. The District nspector to arrange for all precautions for safe working to be taken w hile this work is in hand. including the provision of any necessary Handsignalmen. and the discon nection of Distant signals affected. in accordance with Rule 77. The instructions shewn on pages 23-25 (up to " The British Aluminium Company's Sidings " ) of the Appendix to No. 7 Section of the Service Time Tables in regard to the working of the East Usk Branch. Newport. will be cancelled an d replaced by t he following: Working of East Usk Branch, Newport, T he Up and Down lines between East Usk Junction. Corporation Road. and Uskmouth Signal boxes. also the Up and Down Goods Loops at Corporation Road Signal box. and the Down (" B.A.C. ") Loop at Uskmouthsignal box. are worked in accordance with the Regulations for Signalling T rains an d Engines by Permissive Block System over Goods Running Loop lines and other Permissive lines as shown in Section V of the Book of Regulations fo r T rain Signalling o n Double and Single lines and on pages 57/58 of the General Appendix to the Rule Book. Protection of Commercial Department Staff whilst working at Sidings alongside Down Goods Loop near Lysaght's Works. On occasions when Commercial Department staff are engaged carrying o ut work in connection with wagons stan ding on either of the above Sidings. the following instructions must be strictly o bserved: When Operating Department staff are engaged in the vicinity on shunting operations. the Commercial Department staff must. before commencing work. come to a clear understand ing with the Train or Shunting staff and place a red flag. or red light during hours of darkness. on the last wagon nearest the direction from which vehicles might be shunted against those on which the men will be at work.

When O perating Department staff are not in the vicinity of the sidings a red flag, or red light during the hou rs of darkness, must be placed by the Commercial Departme nt staff before any staff commence work, o n t he last wagon nearest the direction fro m which vehicles might be shunted against those on which the men will be at work, and the O perating Department staff. on observing the red flag or light, must not commence any shunting operations until they have warned the Commercial Department staff that they are about to do so. The red flag, or red light, must not be removed until the work has been completed, or has been suspended to admit shunting, and the Commercial De partment man before removing it must satisfy himself that all the men concerned are clear. Heeley & Peart's Outlet Ground Frame. This ground fra me is situated on the Down side of the Down Branch line at East Usk Junction, working the t raili ng connection from Down Branch line to outlet siding and catch point in siding, and is electrically released from East Usk Junction signal box. Telephone co.mmunication is provided between t he ground frame and East Usk Junction signal box. The Guard or Shu nter. as the case may be, w ill be responsible for working the ground frame and the instructio ns for working ground frames o perated by interlocking lever at signal box and key release instrument at ground frame as shewn in the General Appendix to the Rul e Book must apply. Engineering Depart ment Siding Ground Frame. A faci ng connection in t he Up Branch i ne at East Usk Junction in advance of t he Starting Signal leads to the Engineering Department Sid ings. The points in the Up Branch line are worked by hand lever and must normally be secu red fo r through running over the Up Branch line and clipped and padlocked in th is position, the key of the clip being kept in East Usk Junction signal box. The points must o nly be reversed to permit a movement being made to or from the sidings and t he Guard or Sh unter accompanying the movement will be responsible fo r seeing that the points are left properly secured in their normal position. A wheel stop is provided in the sidings to protect the Up Branch line and must be kept secured across t he rail except when required to be operated for a movement to be made into or out of t he sidings. No train must be allowed to run to the Up Branch while operations are being performed at these sidings. NB.-These instructions will only operate until the sidings are connected to a new ground frame. \ Heeley & Peart's nlet Ground Frame. A faci ng connection in the Down Branch line at East Usk Junction Down Branch Home signal leads to Heeley & Peart's nlet Siding. The points in t he Down Branch line, also the catch point in Siding, are worked by hand lever. The poin ts of Heeley & Peart's inlet connection must normally be secured for through ru nning over the Down Branch line and clipped and padlocked in this position, the key of the cl ip being kept in East Usk Junction Signal box. The points must only be reversed to permit a movement being made to or from the Sidi ng, and the Shunter accompanying the movement will be responsible for seeing that t he poi nts are left properly secured in their normal position. The catch point at Heeley & Peart's inlet connection must be kept clipped and pad locked in the open position except when required t o be closed for a movement to be made into or out of the siding. N.B.-These instructions will only operate until the inlet siding is connected to a new ground frame.

2 Lysaght's nlet Ground Frame. b L This ground frame is situated on the Down side of the Down line near Stephenson Road Bridge in advance of Corporation Road Down Home signals, working the trailing crossover between Up and Down lines, facing connection from Down line to nlet sidings with catch points in sidings, an d signal from Down line to nlet sidings, and is electrically released from Co rporation Road signal box. An inde pendent telephone circuit is provided between the ground frame and Corporation Road signal box. The Guard or Shunter, as the case may be, will be responsible for working the greund frame and t he instructions for working ground frames operated by interlocking lever at signal box and key release instrument at ground frame as shewn in the General Appendix to the Rule Book must apply. The siding connection and crossover are released by separate keys at ground frame and separate interlocking levers in signal box. The Corporation Road Signalman and the Guard or Shunter must have a clear understanding over the independent telephone circuit in regard to all movements bei ng made at the ground frame. Eastern Dry Dock a nd Channel Dry Dock Ground Frames. The ground frames are situated intermediately on the Down line between Uskmouth and Corporation Road sig nal boxes, in each case worki ng a t railing connection from Down line to sid ing, also signal on Down line protecting the connection leadi ng to sid ing. Telephone communication is provided on the East Usk Branch circuit. At each ground frame the signal must normally be kept in the all-right position and must only be replaced to danger in connection with a train calling at the ground frame. Whenever it is necessary for a train to call at either ground frame the Guard or Shunter will be responsi ble for working the ground frame. ' On arrival at either ground frame, the signal must be placed and maintained at danger until the train is ready to leave, when the signal must again be lowered. The G uard or Shu nter must advise the Signalman at Uskmouth signal box when the train is ready to leave either ground frame and the Uskmouth Signalman must advise the Corporation Road Signalman, and un~il this advice is received the Uskmouth Signalman must not allow another train to enter the section. British Al uminium Sidings North Ground Frame. This ground frame is situated intermediately on the Down line between Uskmouth and Corporation Road signal boxes, worki ng a traili ng connection from Down line to B.A.C. outlet sidings, also signal on Down li ne protecting the connection leading to sidings. Telephone communication is provid ed o n t he East Usk Branch circuit and there is also an independent telephone circuit from the ground frame to Uskmouth signal box. The signal must normally be kept in the all-right position and must only be replaced to danger in connection with a train calling at the ground frame

3 Whenever it is necessary for a train to call at the ground frame the Guard or Shunter will be responsible for working the ground frame. On arrival at the ground frame, the signal must be placed and maintained at danger until the train is ready to leave, when the signal must again be lowered. The Guard or Shu nter must advise the Signalman at Uskmouth signal box on the independent telephone circuit when the train is ready to leave the ground frame and the Uskmouth Signalman must advise the Corporation Road Signalman. and until this advice is received the Uskmouth Signalman must not allow another train to enter the section. A t rain may be shunted into the sidings for others to pass, and after the Down line: is clear and the grou nd frame poi nts have been replaced to normal arid the signal lowered. the G uard or Shunter must advise the Uskmouth Signalman accord ingly on t he independent telephone circuit. The Uskmout h Signalman must then advise the Corporation Road Signalman, and Clause 3 of t he Permissive Regulations must be complied with by the Signalmen. Before the ground frame is operated for the train to come out again on to the Down line permission must be obtained by the Guard or Shunter on the independent telephone circuit from the Uskmouth Signalman. who must only give permission provided there is no train already in the section between Uskmouth and Corporatio n Road and the train concerned has again been Signalled forward; after the Uskmouth Signalman has given permission for the train to come out again on to the Down line at the ground frame. he must not allow another train to enter the section until he has been advised by the Guard or Shunter that the train is ready to leave the ground frame. Monsanto Ground Frame. This ground frame is situated on the Up side of the Up line in advance of Uskmouth Up Home Signal, working the trailing crossover between Down and Up lines and trailing connection from Up line to siding with catch point in siding. and is electrically released from Uskmouth Sig nal box. Telephone communication is provided on the East Usk Branch circuit and t here is also an indep,endent telephone circuit between the ground frame and Uskmouth signal box. The Guard o r' Shu nter. as the case may be. will be responsible for working the ground frame and the instructions for working ground frames operated by interlocking lever at Signal box and key release instrument at ground frame as shown in the General Appendix to the Rule Book must apply. The siding connection and crossover are released by separate keys at ground frame and separate interlocking levers in Signal box.. The Uskmouth Signalman and the Guard or Shunter must have a clear understanding over the independent t elephone circuit in regard to all movements being made at the ground frame. British Aluminium Sidings South Ground Frame. This ground frame is situated on the Down side of the Down line in advance of Uskmouth Starting Signal. working the outlet from the Down (" B.A.C.") Loop with catch point in loop. and is electrically released from Uskmouth Signal box. An independent telephone circuit is provided between the ground frame and Uskmouth signal box.

4 The Guard or Shunter, as the case may be, will be responsible for working the ground frame and the instructions for working ground frames operated by interlocking lever at signal box and key release instrument at ground frame as shewn in the General Appendix to the Rule Book must apply. A stop lamp is provided at the catch point at the outlet and must not be passed without the permission of the Uskmouth Signalman. The following additional alterations to be made to the Appendix to No. 7 Section of the Service Time Tables: Pages 6-0. Ground Fra mes and ntermediate Sidings. The entries on page 8 under" East Usk Branch" to be replaced by the following : Name of Station or Siding. By whom Where situated. attended. How locked. Remarks. Heeley & Peart's Outlet. East Usk Junction. Guard or Shunter. Electrically released See p. 23. from East Usk Jet. signal box. Engineering Dept. do. do. Clipped and pad- do. locked. Heeley & Peart's nlet. Lysaght's nlet. do. Between Corporation Road and Uskmouth. do. do. do. do. Electrically released fro m Corporation Road signal box. do. Eastern Dry Dock. do. do. - do. Channel Dry Dock. do. do. - do. British Alu minium Sidings North. do.. do. - do. Monsanto. do. do. Electrically released do. from Uskmouth signal box. British Aluminium Sidings South. do. do. do. do. Pages -5. Single Lines and how worked. Delete reference on page 3 to East Usk Branch.

Pages 6-63. Propelling of Vehicles. 5 The entry on page 62 " from East Usk Junction to Branch Terminus " to be replaced by the followi ng: From. East Usk Junction. Uskmouth. To.. Uskmouth (or intermediately). 3 m. East Usk Junction i ntermed iately). 3 m. (or line. Up. Down. Re marks. Brake Van.only. Brake Van only. Page 25. The British Aluminium Company's Sidings. The engine restrictions to be transferred to page 55. N.B.-The existing working in Uskmouth Power Station Sidings will continue until furthe r notice. AC KN OWLEDGE REC EPT. Newport, September. 952. (W.782.) W. R. STEVE NS. District Operating Superintendent. ~ ~ ~ ----- - - Received copy of Mr. W. R. Stevens's Notice No. W.528 re Doubling of East Usk Branch. Newport. Date 952.... Signature. To: District Operating Supt., Department. NEWPORT. (W.782.) Station. )

Ne H r - - COHTRO~~ED F ROM USKMOutH. -, H UP MAN - -L. fi.&_~_--=:;-:::::--..lr-«j-'-=_, HQ PlHG To PoWER -.-_- OoW... MAN...- ---.;;;~~--r--''''''--"''t:'''::----~--=-(6-=-t4 HQ2 S,.ATON '-Ca. ~P ~O ~ ~~WNl.OOP<J)_~K~~ 9. ~.C. ::>PU" - - - ~.l' /' Tii4 : t J ~tlt\nneb : MTS u~dock USKMOUTH" T g :, EA&TERN B.A.C. a.a. C. ORY DOCK SiDiNGs si'dings HOlnH G.F'. Sou~ G.F: t SGNAL Box.

D OUBl.NG EAST USK BRANCH OF- 9 Tin l :,C:~~!, ~ CORPORATON ROAO ~ LYSAGMTS S GNAL aox. NLET G.F. WOR(JNG PoiNTS...SQH"L. ~ EA&TERN DRY DOC..E

he following from ground frame. 54 yards. with lever Telephone n Uskmouth e with loudtive Circuit. rom ground frame. 60 yards. ~ e With lever telephone provided. PONTS MARKEQ CUPPED ~ PA.OL.OCKED SET AS SHOWN. l om ground frame. 7 yards. ith lever telephone provided.