R&S RT-Zxx High-Voltage and Current Probes Specifications Test & Measurement Data Sheet 14.00
CONTENTS Definitions... 3 Probe/oscilloscope chart... 4 R&S RT-ZH10/-ZH11 high-voltage probes... 5 R&S RT-ZD01 high-voltage differential probe... 8 R&S RT-ZC05B/-ZC10(B)/-ZC15B/-ZC20(B)/-ZC30 current probes... 11 R&S RT-ZA13 probe power supply... 16 Ordering information... 17 2 Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes
Definitions General Product data applies under the following conditions: Three hours storage at ambient temperature followed by 30 minutes warm-up operation Specified environmental conditions met Recommended calibration interval adhered to Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <,, >,, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift and aging, if applicable. Specifications without limits Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design. Typical data (typ.) Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the mean value. Measured values (meas.) Characterize expected product performance by means of measurement results gained from individual samples. Typical data as well as measured values are not warranted by Rohde & Schwarz. Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes 3
Probe/oscilloscope chart Probe: R&S Base unit: R&S RTM RTE/RTO RT-ZA9 Page 200 MHz 350 MHz 500 MHz 1 GHz 200 MHz Passive probes RT-ZH10 5 RT-ZH11 5 Differential probes RT-ZD01 8 Current probes RT-ZC10 11 RT-ZC20 11 RT-ZC30 11 RT-ZC05B 11 RT-ZC10B 11 RT-ZC15B 11 RT-ZC20B 11 recommended extra possible accessory, with limited functionality of probe or base unit 350 MHz 500 MHz 600 MHz 1 GHz 2 GHz 4 GHz 4 Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes
R&S RT-ZH10/-ZH11 high-voltage probes All parameters are valid when the probe is connected to an appropriate Rohde & Schwarz oscilloscope with an input impedance of 1 MΩ. See table on page 4 and Rohde & Schwarz oscilloscope operating manual for more details. R&S RT-ZH10 R&S RT-ZH11 Step response Rise time system, 10 % to 90 % 900 ps (meas.) Frequency response Bandwidth system, 3 db, starting at DC > 400 MHz Input impedance DC input resistance system 50 MΩ ± 1 % Input capacitance system 7.5 pf (meas.) DC characteristics Attenuation system, automatically corrected on base unit display 100:1 1000:1 Attenuation error probe only, with ideal 1 MΩ load impedance ±2 % Attenuation voltage coefficient ±0.0005 %/V (meas.) Maximum rated input voltage Continuous voltage derated, see figures on page 6 1000 V (RMS), CAT II Transient overvoltage ±4000 V Base unit Input capacitance must be compensated by probe s LF compensation 5 pf to 20 pf Input coupling 1 MΩ AC/DC Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes 5
R&S RT-ZH10/-ZH11 maximum rated sine-wave root mean square voltage versus frequency, CAT I. R&S RT-ZH10/-ZH11 maximum root mean square voltage versus peak pulse voltage, CAT I. R&S RT-ZH10/-ZH11 maximum pulse derating, CAT I. 6 Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes
General data Temperature Temperature loading operating temperature range 0 C to +50 C storage temperature range 40 C to +70 C Climatic loading 80 % relative humidity for temperatures up to +31 C, decreasing linearly to 40 % at +50 C Altitude operation up to 2000 m transport up to 15000 m Safety in line with Low Voltage Directive 2006/95/EC, IEC/EN 61010-31 (pollution degree 2) Mechanical data Dimensions diameter of probe tip approx. 5 mm (0.2 in) cable length approx. 2 m (79 in) Weight probe only approx. 67 g (0.15 lb) Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes 7
R&S RT-ZD01 high-voltage differential probe All parameters are valid when the probe is connected to an appropriate Rohde & Schwarz oscilloscope with an input impedance of 1 MΩ. See table on page 4 and Rohde & Schwarz oscilloscope operating manual for more details. R&S RT-ZD01 Attenuation setting 100:1 1000:1 Step response Rise time 10 % to 90 % < 3.5 ns (meas.) Frequency response Bandwidth starting at DC, calculated from 0.35/rise time 100 MHz Common mode rejection DC to 100 Hz 80 db (meas.) 100 Hz to 1 MHz 50 db (meas.) Input impedance DC input resistance differential (between signal sockets) 8 MΩ single-ended (each signal socket to ground) 4 MΩ Input capacitance differential (between signal sockets) 3.5 pf (meas.) single-ended (each signal socket to ground) 7 pf (meas.) DC characteristics Attenuation error ±2 % Zero error ±0.5 V (meas.) ±5 V (meas.) Dynamic range Differential input between signal sockets ±140 V ±1400 V Operating voltage window each signal socket to ground ±1400 V Noise voltage referenced to probe input 90 mv (RMS) (meas.) 0.9 V (RMS) (meas.) 8 Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes
Maximum rated input voltage Continuous voltage Base unit Input coupling derated, see figure, each signal socket to ground 1000 V (RMS), CAT III 1 MΩ AC/DC 10000 Sine-wave RMS voltage [V] 1000 100 10 100E3 1E6 10E6 100E6 Frequency [Hz] Maximum rated sine-wave root mean square voltage versus frequency. Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes 9
General data Temperature Temperature loading operating temperature range 0 C to +40 C storage temperature range 30 C to +70 C Climatic loading 85 % relative humidity Altitude operation up to 2000 m transport up to 4600 m EMC in line with EMC Directive 2004/108/EC, IEC/EN 61326-1, IEC/EN 61326-2-2 Calibration interval 2 years Safety in line with Low Voltage Directive 2006/95/EC, IEC/EN 61010-31 (pollution degree 2) Mechanical data Dimensions probe head (L W H) approx. 207 mm 83 mm 38 mm (8.1 in 3.2 in 1.5 in) length of input leads approx. 30 cm (12 in) length of probe cable approx. 90 cm (35 in) Weight probe only approx. 500 g (1.1 lb) 10 Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes
R&S RT-ZC05B/-ZC10(B)/-ZC15B/-ZC20(B)/-ZC30 current probes All parameters are valid when the probe is connected to an appropriate Rohde & Schwarz oscilloscope with an input impedance of 1 MΩ. See table on page 4 and Rohde & Schwarz oscilloscope operating manual for more details. R&S RT-ZC05B R&S RT-ZC10(B) Step response Rise time 10 % to 90 % 175 ns (meas.) 35 ns (meas.) Frequency response Bandwidth 3 db, starting at DC 2 MHz (meas.) 10 MHz (meas.) Input impedance see figure on page 15 DC characteristics Sensitivity 0.01 V/A Sensitivity error +23 C ±3 C ±1 % Zero error referenced to probe input after ±500 ma (meas.) ±100 ma (meas.) demagnetizing and zero adjustment AC characteristics AC sensitivity error (sinusoidal, 45 Hz to 66 Hz) +23 C ±3 C ±1 % ± 500 ma (RMS) (meas.) ±1 % ± 100 ma (RMS) (meas.) 0 C to +40 C ±3 % ± 500 ma (RMS) (meas.) ±3 % ± 100 ma (RMS) (meas.) Measurement due to external 400 A/m magnetic field, DC or 60 Hz, < 800 ma (RMS) (meas.) < 150 ma (RMS) (meas.) magnetic fields referenced to probe input Maximum rated input Maximum continuous current derated, see figures on page 15 500 A (RMS) 150 A (RMS) Maximum transient current peak ±700 A ±300 A Other Noise 20 MHz measurement bandwidth, referenced to probe input 25 ma (RMS) (meas.) Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes 11
R&S RT-ZC15B R&S RT-ZC20(B) Step response Rise time 10 % to 90 % 7 ns (meas.) 3.5 ns (meas.) Frequency response Bandwidth 3 db, starting at DC 50 MHz (meas.) 100 MHz (meas.) Input impedance see figure on page 15 DC characteristics Sensitivity 0.1 V/A Sensitivity error +23 C ±3 C ±1 % Zero error referenced to probe input after ±10 ma (meas.) demagnetizing and zero adjustment AC characteristics AC sensitivity error +23 C ±3 C ±1 % ± 10 ma (RMS) (meas.) (sinusoidal, 45 Hz to 66 Hz) 0 C to +40 C ±3 % ± 10 ma (RMS) (meas.) Measurement due to external 400 A/m magnetic field, DC or 60 Hz, < 20 ma (RMS) (meas.) < 5 ma (RMS) (meas.) magnetic fields referenced to probe input Maximum rated input Maximum continuous current derated, see figures on page 15 30 A (RMS) Maximum transient current peak ±50 A Other Noise 20 MHz measurement bandwidth, referenced to probe input 2.5 ma (RMS) (meas.) 12 Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes
R&S RT-ZC30 Step response Rise time 10 % to 90 % 2.9 ns (meas.) Frequency response Bandwidth 3 db, starting at DC 120 MHz (meas.) Input impedance see figure on page 15 DC characteristics Sensitivity 1 V/A Sensitivity error +23 C ±3 C ±3 % Zero error referenced to probe input ±1 ma (meas.) after demagnetizing and zero adjustment AC characteristics AC sensitivity error +23 C ±3 C ±3 % ± 1 ma (RMS) (meas.) (sinusoidal, 45 Hz to 66 Hz) 0 C to +40 C ±5 % ± 1 ma (RMS) (meas.) Measurement due to external 400 A/m magnetic field, DC or 60 Hz, < 5 ma (RMS) (meas.) magnetic fields referenced to probe input Maximum rated input Maximum continuous current derated, see figures on page 15 5 A (RMS) Maximum transient current peak ±7.5 A Other Noise 30 MHz measurement bandwidth, referenced to probe input 60 µa (RMS) (meas.) Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes 13
General data R&S RT-ZC05B/ R&S RT-ZC10(B) R&S RT-ZC15B/ R&S RT-ZC20(B)/ R&S RT-ZC30 Temperature Temperature loading operating temperature range 0 C to +40 C storage temperature range 10 C to +50 C Climatic loading 80 % relative humidity Altitude operation up to 2000 m Safety in line with EN 61010-2-032 (type D sensor, insulated conductor only) EMC in line with EN 61326-1, CISPR 11/EN 55011 (class B, table 2) Calibration interval 2 years Mechanical data Dimensions max. conductor diameter approx. 20 mm (0.79 in) approx. 5 mm (0.2 in) cable length, probe approx. 2 m (78.7 in) approx. 1.5 m (59 in) cable length, power supply of approx. 1 m (39.4 in) approx. 1 m (39.4 in) R&S RT-ZCxx probe head (W H L) approx. 27 mm 69 mm 176 mm (1.06 in 2.72 in 6.93 in) approx. 18 mm 40 mm 175 mm (0.71 in 1.57 in 6.89 in) Weight probe only approx. 500 g (1.1 lb) approx. 240 g (0.53 lb) Interface R&S RT-ZCxx BNC R&S RT-ZCxxB Rohde & Schwarz probe interface Supply voltage R&S RT-ZCxx external power supply necessary (e.g. R&S RT-ZA13) ±12 V ± 0.5 V (5.5 W) R&S RT-ZCxxB power supply by Rohde & Schwarz probe interface 14 Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes
Version 14.00, March 2016 Maximum rated sine-wave root mean square input current versus frequency. Input impedance (meas.). Maximum rated sine-wave root mean square input current versus frequency. Input impedance (meas.). Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes 15
R&S RT-ZA13 probe power supply Electrical data Number of channels 4 Output voltage ±12 V ± 0.5 V Maximum output current sum total of all channels 2.5 A Power requirements 100 V to 240 V, 50/60 Hz Maximum rated input power 170 W General data Safety in line with EN 61010-1 EMC in line with EN 61326-1 (class B equipment), EN 61000-3-2, EN 61000-3-3 Mechanical data Dimensions W H L approx. 80 mm 119 mm 200 mm (3.1 in 4.7 in 7.9 in) Weight approx. 1.1 kg (2.4 lb) Connector LEMO FFA.OS.304.CLAC44Z 16 Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes
Ordering information Designation Type Order No. High-voltage passive probes 400 MHz High-Voltage Probe, passive, 100:1, 50 MΩ, 7.5 pf, 1 kv (RMS) R&S RT-ZH10 1409.7720.02 Incl. adjustment tool; BNC adapter 5.0-L; coding rings (set) 3 4 colors; flexible adapter 5.0-L; ground lead 22 cm (2); ground lead 22 cm to 4 mm banana plug; insulating cap 5.0-L; operating manual; protection cap 5.0-L; safety alligator clip (2); solid tip 0.8 mm (5); spring tip 0.8 mm (5); sprung hook 5.0-L (2) 400 MHz High-Voltage Probe, passive, 1000:1, 50 MΩ, 7.5 pf, 1 kv (RMS) R&S RT-ZH11 1409.7737.02 See R&S RT-ZH10 for equipment included Differential probes 100 MHz, 1.4 kv High-Voltage Probe, differential, 1 kv RMS (CAT III) R&S RT-ZD01 1422.0703.02 Incl. sprung hook 4 mm (2); USB power cord; carrying case; operating manual Current probes 10 MHz, AC/DC, 0.01 V/A, 150 A (RMS) R&S RT-ZC10 1409.7750K02 Incl. carrying case; operating manual 100 MHz, AC/DC, 0.1 V/A, 30 A (RMS) R&S RT-ZC20 1409.7766K02 Incl. carrying case; operating manual 120 MHz, AC/DC, 1 V/A, 5 A (RMS) R&S RT-ZC30 1409.7772K02 Incl. carrying case; operating manual 2 MHz, AC/DC, 0.01 V/A, 500 A (RMS), Rohde & Schwarz probe interface R&S RT-ZC05B 1409.8204.02 Incl. carrying case; operating manual 10 MHz, AC/DC, 0.01 V/A, 150 A (RMS), Rohde & Schwarz probe interface R&S RT-ZC10B 1409.8210.02 Incl. carrying case; operating manual 50 MHz, AC/DC, 0.1 V/A, 30 A (RMS), Rohde & Schwarz probe interface R&S RT-ZC15B 1409.8227.02 Incl. carrying case; operating manual 100 MHz, AC/DC, 0.1 V/A, 30 A (RMS), Rohde & Schwarz probe interface Incl. carrying case; operating manual R&S RT-ZC20B 1409.8233.02 Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes 17
Designation Type Order No. Accessories and sets Mini Clips, contains: mini clip (10) R&S RT-ZA4 1416.0428.02 Micro Clips, contains: micro clip (4) R&S RT-ZA5 1416.0434.02 Lead Set, contains: lead 6 cm (2.4 in) (5); lead 15 cm (5.9 in) (5) R&S RT-ZA6 1416.0440.02 Probe Box to N/USB Adapter R&S RT-ZA9 1417.0909.02 SMA(f) to BNC(m) Adapter R&S RT-ZA10 1416.0457.02 Probe Power Supply R&S RT-ZA13 1409.7789.02 18 Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes
Rohde & Schwarz R&S RT-Zxx High-Voltage and Current Probes 19
Service that adds value Worldwide Local and personalized Customized and flexible Uncompromising quality Long-term dependability Sustainable product design Environmental compatibility and eco-footprint Energy efficiency and low emissions Longevity and optimized total cost of ownership Certified Quality Management ISO 9001 Certified Environmental Management ISO 14001 Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com Regional contact Europe, Africa, Middle East +49 89 4129 123 45 customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia Pacific +65 65 13 04 88 customersupport.asia@rohde-schwarz.com China +86 800 810 82 28 +86 400 650 58 96 customersupport.china@rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners PD 5214.2362.22 Version 14.00 March 2016 (sk) R&S RT-Zxx High-Voltage and Current Probes Data without tolerance limits is not binding Subject to change 2009-2016 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany 5214.2362.22 14.00 PDP 1 en 5214236222