Measurements Results of GBd VCSEL Over OM3 with and without Equalization

Similar documents
Ali Ghiasi. Jan 23, 2011 IEEE GNGOPTX Study Group Newport Beach

Ali Ghiasi. Nov 8, 2011 IEEE GNGOPTX Study Group Atlanta

Transmitter Preemphasis: An Easier Path to 99% Coverage at 300m?

40G SWDM4 MSA Technical Specifications Optical Specifications

10GBASE-LRM Interoperability & Technical Feasibility Report

CAUI-4 Chip to Chip Simulations

64G Fibre Channel strawman update. 6 th Dec 2016, rv1 Jonathan King, Finisar

40G SWDM4 MSA Technical Specifications Optical Specifications

CAUI-4 Chip to Chip and Chip to Module Applications

40GBd QSFP+ SR4 Transceiver

SMF Ad Hoc report. Pete Anslow, Ciena, SMF Ad Hoc Chair. IEEE P802.3bm, Geneva, September 2012

o-microgigacn Data Sheet Revision Channel Optical Transceiver Module Part Number: Module: FPD-010R008-0E Patch Cord: FOC-CC****

SECQ Test Method and Calibration Improvements

Application Space of CAUI-4/ OIF-VSR and cppi-4

100G CWDM Link Model for DM DFB Lasers. John Petrilla: Avago Technologies May 2013

CAUI-4 Application Requirements

100G SR4 Link Model Update & TDP. John Petrilla: Avago Technologies January 2013

100G QSFP28 SR4 Transceiver

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

Performance comparison study for Rx vs Tx based equalization for C2M links

Systematic Tx Eye Mask Definition. John Petrilla, Avago Technologies March 2009

Features: Compliance: Applications: Warranty: 49Y7928-GT QSFP+ 40G BASE-SR Transceiver IBM Compatible

40GBASE-ER4 optical budget

TP2 and TP3 Parameter Measurement Test Readiness

On Figure of Merit in PAM4 Optical Transmitter Evaluation, Particularly TDECQ

400G-FR4 Technical Specification

Draft Baseline Proposal for CDAUI-8 Chipto-Module (C2M) Electrical Interface (NRZ)

100G-FR and 100G-LR Technical Specifications

PAM8 Baseline Proposal

Ordering information. 40Gb/s QSFP+ ER4 Optical Transceiver Product Specification. Features

A 90 Gb/s 2:1 Multiplexer with 1 Tap FFE in SiGe Technology

Product Specification 56Gbps 60/100m QSFP+ Optical Transceiver Module FTL414QB2C APPLICATIONS

10Gbps SFP+ Optical Transceiver, 10km Reach

QSFP SV-QSFP-40G-PSR4

MR Interface Analysis including Chord Signaling Options

System Evolution with 100G Serial IO

Investigation of PAM-4/6/8 Signaling and FEC for 100 Gb/s Serial Transmission

Investigation of PAM-4/6/8 Signaling and FEC for 100 Gb/s Serial Transmission

Summary of NRZ CDAUI proposals

FIBRE CHANNEL CONSORTIUM

Draft 100G SR4 TxVEC - TDP Update. John Petrilla: Avago Technologies February 2014

50 Gb/s per lane MMF objectives. IEEE 50G & NGOATH Study Group January 2016, Atlanta, GA Jonathan King, Finisar

Product Specification 40BASE-SR4 QSFP+ Gen3 Optical Transceiver Module FTL410QE3C

Comparison of NRZ, PR-2, and PR-4 signaling. Qasim Chaudry Adam Healey Greg Sheets

10Gbps 10km Range SFP+ Optical Transceiver

Maps of OMA, TDP and mean power. Piers Dawe Mellanox Technologies

Product Specification 40BASE-SR4 100m QSFP+ Gen2 Optical Transceiver Module FTL410QE2C

10Gbps 10km Range 1310nm SFP+ Optical Transceiver

100GBASE-FR2, -LR2 Baseline Proposal

Improved extinction ratio specifications. Piers Dawe Mellanox

DATA SHEET. Two (2) fibers Detachable HDMI 2.0 Extender,

100G SR4 TxVEC Review Comment r01-43

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

Validation of VSR Module to Host link

EVLA Fiber Selection Critical Design Review

XLAUI/CAUI Electrical Specifications

100Gb/s Single-lane SERDES Discussion. Phil Sun, Credo Semiconductor IEEE New Ethernet Applications Ad Hoc May 24, 2017

200GBASE-DR4: A Baseline Proposal for the 200G 500m Objective. Brian Welch (Luxtera)

EMPOWERFIBER 10Gbps 2km SFP+ Optical Transceiver EPP C

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

Simulations of Duobinary and NRZ Over Selected IEEE Channels (Including Jitter and Crosstalk)

CDAUI-8 Chip-to-Module (C2M) System Analysis #3. Ben Smith and Stephane Dallaire, Inphi Corporation IEEE 802.3bs, Bonita Springs, September 2015

100G PSM4 & RS(528, 514, 7, 10) FEC. John Petrilla: Avago Technologies September 2012

QSFP+ 40GBASE-SR4 Fiber Transceiver

Measurements and Simulation Results in Support of IEEE 802.3bj Objective

100GEL C2M Channel Reach Update

New Serial Link Simulation Process, 6 Gbps SAS Case Study

Thoughts about adaptive transmitter FFE for 802.3ck Chip-to-Module. Adee Ran, Intel Phil Sun, Credo Adam Healey, Broadcom

Component BW requirement of 56Gbaud Modulations for 400GbE 2 & 10km PMD

Development of an oscilloscope based TDP metric

100GBASE-DR2: A Baseline Proposal for the 100G 500m Two Lane Objective. Brian Welch (Luxtera)

Baseline proposal update

DATA SHEET. Two (2) fibers Detachable DisplayPort 1.2 Extender, DPFX-200-TR

Refining TDECQ. Piers Dawe Mellanox

Exceeding the Limits of Binary Data Transmission on Printed Circuit Boards by Multilevel Signaling

The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting postamplifier

10 Gb/s Duobinary Signaling over Electrical Backplanes Experimental Results and Discussion

Development of an oscilloscope based TDP metric

Further Clarification of FEC Performance over PAM4 links with Bit-multiplexing

BER margin of COM 3dB

Practical Receiver Equalization Tradeoffs Applicable to Next- Generation 28 Gb/s Links with db Loss Channels

DATA SHEET. Two (2) fibers Detachable DisplayPort Extender, DPFX-100-TR

Product Specification 100m Multirate Parallel MMF 100/128G QSFP28 Optical Transceiver FTLC9551SEPM

An Approach To 25GbE SMF 10km Specification IEEE Plenary (Macau) Kohichi Tamura

FTS-M12G-S85L-55M. SFP 1000Base-SX, 850nm, multi-mode, 550m

50 Gb/s per lane MMF baseline proposals. P802.3cd, Whistler, BC 21 st May 2016 Jonathan King, Finisar Jonathan Ingham, FIT

COM Study for db Channels of CAUI-4 Chip-to-Chip Link

500 m SMF Objective Baseline Proposal

Technical Feasibility of Single Wavelength 400GbE 2km &10km application

ELECTRICAL PERFORMANCE REPORT

The Case of the Closing Eyes: Is PAM the Answer? Is NRZ dead?

OC-48/STM-16 SFP Transceiver (SR) RSP25SS1

PAM4 signals for 400 Gbps: acquisition for measurement and signal processing

OC-48/STM-16 Bi-directional SFP Transceiver (40km) RBT25SI2

Proposal for 400GE Optical PMD for 2km SMF Objective based on 4 x 100G PAM4

10Gb/s SFP+ ER 1550nm Cooled EML with TEC, PIN Receiver 40km transmission distance

100G EDR and QSFP+ Cable Test Solutions

Duobinary Transmission over ATCA Backplanes

10G- XFP- SR- AO. 10Gbs XFP Transceiver

Transcription:

Measurements Results of 25.78 GBd VCSEL Over OM3 with and without Equalization IEEE 100GNGOPTX Study Group Ali Ghiasi and Fred Tang Broadcom Corporation May 14, 2012 Minneapolis

Overview Test setup Measured and simulated eye diagrams Calculated WDP and pulse response BER plot Example FFE implementation Authors are thankful to Jim Tatum and Jonathan King of Finisar for their contributions and for providing VCSELs samples for this work. Authors are thankful to Robert Lingle and Xinli Jiang of OFS for fiber measurements and for their contributions. 2

Basic Test Setup VCSEL was driven directly from a 25.78 GBd SerDes test chip Laser was biased through bias-t and driven single-ended with 250 mvpp amplitude No benefit seen by increasing de-emphasis beyond compensating for the test board Laser test and reliability results were presented at Photonics West by Finisar The VCSEL die output was collimated with NA=0.47 lens then focused with NA=0.23 lens into an 50/120 um OM3 fiber patch cord VCSEL was biased at 5 ma with ~ 5dB extinction ratio Optical receiver had 15.5GHz BW, ~ 150V/W differential conversion gain, and -5.5dBm sensitivity 25G-TX 25G-VCSEL OM3 3 m OM3 Cable 100 m or 150 m OM3 3 m PD/TIA Optional PCB Trace 25G-RX Connector Connector 3

Creating Worst Case OM3 Fiber Worst case OM3 fiber has an average DMD of 0.32 ps/m The OM3 fiber previously used had an average DMD of 0.205 ps/m with EMBW of 2930 MHz.km An out of spec OM3 fiber was located with average DMD of 0.66 ps/ m with EFMB of 1057 MHz.km The nominal length of the previously used OM3 fiber and the out spec OM3 fiber were combined to have an average DMD of 0.32 ps/m at the specified length Example below show how the two fiber were combined to get 100 m. 25G-TX 25G-VCSEL Connector 75 m with DMD=0.205 OM3 3 m 25 m with DMD=0.666 ps/m Connector OM3 3 m PD/TIA 25G-RX 100 m OM3 @0.32 ps/m 4

PRBS31 Eye Diagram at 25.78 GBd Response for 150 m typical OM3 is comparable to worst case 100 m Eye Diagram with typical OM3 fiber as shown http://www.ieee802.org/3/100gngoptx/public/mar12/plenaryghiasi_01_0312_ng100goptx.pdf Optical B2B 100m OM3 150m OM3 Eye diagram for worst case OM3 fiber Optical B2B 100m OM3 150m OM3 5

Clear Eye Opening Worst Case OM3 Fiber is OM3 with varying lengths Clear Eye measured at center of the eye, CE (0.2UI) measured within +/- 0.1UI from center of the eye No indication of penalty cliff! VECP=4.5dBo VECP=5.4dBo VECP=5.5dBo 6

Worst Case OM3 Jitter Fiber is OM3 with varying lengths TJ & DDJ specified at 1e-12 BER 7

Unequalized Link SNR for Worst Case OM3 SNR_prbs9 is measured at long ones and zeros at beginning of pattern SNR_EC is defined by minimum eye opening at center of eye SNR_EC (0.2UI) is defined by minimum eye opening within +/- 0.1UI from center of eye 8

OM3 Fibers Frequency Response For nominal OM3 fiber and worst case Fiber DMD=0.205 ps/m Fiber DMD=0.32 ps/m 9

25.78 GBd Eye diagrams for nominal OM3 fiber Equalized eye after 6 m of OM3 fiber Relative equalized eye opening gain for various equalizer shown 22 mv +9.8 db +12.9 db +5.8 db +10.1 db +9.8 db 10

25.78 GBd Eye diagrams for nominal OM3 fiber 100 m of nominal OM3 + 6 m of nominal OM3 fiber Relative equalized eye opening gain for various equalizer shown 13 mv +12.8 db +15.6 db +6.7 db +12.4 db +13.4 db 11

25.78 GBd Eye Diagrams for Worst Case OM3 Fiber 100 m of worst case OM3 + 6 m of nominal OM3 fiber Relative equalized eye opening gain for various equalizer shown 12 mv + 12.2 db +14.8 db +6.0 db +11.8 db +14.9 db 12

25.78 GBd Eye diagrams for nominal OM3 fiber 150 m of nominal OM3 + 6 m of nominal OM3 fiber Relative equalized eye opening gain for various equalizer shown 10 mv +12.4 db +16.0 db +6.0 db +13.6 db +14.8 db 13

25.78 GBd Eye Diagrams for Worst Case OM3 Fiber 150 m of worst case OM3 + 6 m of nominal OM3 fiber Relative equalized eye opening gain for various equalizer shown 5 mv + 18.3 db +21.7 db +12.0 db +19.5 db +21.4 db 14

Summary of Vertical Eye Openings @ 1E-12 Unequalized eye opening at 106 m drops almost by half from 6 m Unequalized eye for worst case OM3 at 150 m is half the nominal fiber eye opening but equalized eye not that different Moderate size equalizer improve the eye opening in every case! Fiber Type 6 m OM3 Nominal 100 m OM3 Nominal + 6 m Patchcord 100 m OM3 Worst Case + 6 m Patchcord 150 m OM3 Nominal + 6 m Patchcord 150 m OM3 Worst Case + 6 m Patchcord No-EQ (mv) FFE4 DFE0 (mv) FFE6 DFE0 (mv) FFE1 DFE2 (mv) FFE4 DFE1 (mv) FFE6 DFE3 (mv) 22 68 97 43 70 69 13 57 78 28 54 61 12 49 66 24 47 57 10 42 63 20 48 55 5 41 61 20 47 59 15

BER Results For Nominal OM3 Fiber Results are with and without 1 tap DFE B2B uneq still is about -3 dbm B2B sensitivity with EQ improves by 1 dbm from previous results B2B sensitivity with EQ and without EQ improves by 2.5 dbm 150m OM3 long term BER à 99.98% EF conf level at 1E-15 100m OM3 + 5 PCB no longer has an error floor 16

Summary Measured results with worst case OM3 fiber having DMD of 0.32 ps/m does show more degradation The penalty from a nominal 150 m OM3 fiber is comparable to the worst case OM3 with length of 100 m With a modest equalizer there is very little difference between worst case fiber and nominal fiber VCSEL and PIN/TIA are the dominant sources of penalty but a modest equalizer can reduce these inherent penalty which exist even for B2B 25.78 GBd test chip which has both CTLE and 1-DFE was used as receiver 1 tap DFE receiver has gains of 2.5 dbo and the nominal 150 m OM3 link runs error free for 4 days with <1E-15 @ 99.98 confidence level! Spreadsheet model predicts at 100 m of OM3 we should see an error floor Up to 150 m of worst case OM3 fiber the eye opening and SNR drops only gradually and no error floor yet has been observed! 17

Thank You