SCOPE OF ACCREDITATION TO ISO/IEC & ANSI/NCSL Z & ANSI/NCSL Z

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

DRAFT SCOPE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO 17025:2005 & ANSI/NCSL Z

Accredited Laboratory

National Voluntary Laboratory Accreditation Program

R&S RT-Zxx High-Bandwidth Probes Specifications

Agilent 5345A Universal Counter, 500 MHz

Advanced Test Equipment Rentals ATEC (2832)

R&S RT-Zxx High-Voltage and Current Probes Specifications

Accreditation No: LAB 018. Precision Measuring Equipment Laboratory APF, PAC Kamra, Attock, Pakistan.

Clamp 200 A AC/DC (+ V AC/DC + Ω)

Accreditation No: LAB 018. Precision Measuring Equipment Laboratory APF, PAC Kamra, Attock, Pakistan.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE

Certificate of Calibration

Agilent 8560 E-Series Spectrum Analyzers

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

e2b calibration 521 Fifth Avenue Chardon, Ohio Phone: Fax: Certificate Of Calibration

Calibration Certificate

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

R&S RT-Zxx Standard Probes Specifications

ScopeMeter 190 Series Specifications

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Texas Indicator & Micrometer Repair Service All Work Guaranteed Prompt Service

Display Information Type Backlit blue on white STN Type

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

SMS3000X Series Spectrum Analyzer

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Fluke 279 FC True-rms Thermal Multimeter

MULTIBAND 1/3 RACK-MOUNTED

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

R&S EDS300 DME/Pulse Analyzer Specifications

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

Application Note 5098

Orbital Ka-ISO. Ext Ref Ka LNB with integrated isolator. Orbital Research Ltd Marine Drive, White Rock, BC. Canada V4B 1A9

WVR500 Waveform/Vector Monitor


R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Full-featured CW Microwave Counters for Field, Factory or Lab

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Power Amplifier 1.5 MHz to 18 GHz, Split Bands. Now with smart digital monitoring and control options 19 Rack Mount Family Data Sheet

Specifications. Reference Documentation. Performance Conditions

300MHz Single Supply Video Amplifier with Low In/Out Rail -IN -IN +IN +IN -VCC. Part Number Temperature Range Package Packaging Marking TSH341ILT

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

E4416A EPM-P Series Single Channel Power Meter

E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET

Detailed Design Report

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

Test Procedure for Common Path Distortion (CPD)

TA2000B-x GHz Fast Pulse / Timing Preamplifier User Manual

HP 70950B OPTICAL SPECTRUM ANALYZER

R&S RT-ZVCxx Multi-Channel Power Probe Specifications

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

WaveDriver 20 Potentiostat/Galvanostat System

RS Pro SPECTRUM ANALYZER SSA3000X SERIES

Synthesized Clock Generator

Certificate of Calibration

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

R&S FSMR Measuring Receiver Specifications

R&S RT-Zxx Oscilloscope Adapters Specifications. Data Sheet V23.00

Orbital 4400X & 4400XI Series X-Band Ext Ref LNB

Signal Stability Analyser

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

I/A Series Hardware Fiber Optic LAN Converter

SHF Communication Technologies AG,

Magnetic Sensor - Incremental EHP

WaveNow USB Potentiostat / Galvanostat

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

TSG 90 PATHFINDER NTSC Signal Generator

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

R3267/3273 Spectrum Analyzers

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

Extension kit for R&S Vector Network Analysers

LAUREL ELECTRONICS, INC.

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

1/3 RACK-MOUNTED BLOCK CONVERTERS

2 MHz Lock-In Amplifier

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

Microwave Counter, Power Meter and DVM in One Portable Package

FREQUENCY COUNTERS TO 18 GHZ USING THE DATUM FREQUENCY STANDARD

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Features. PFD Output Voltage 2000 mv, Pk - Pk. PFD Gain Gain = Vpp / 2π Rad khz 100 MHz Square Wave Ref.

Noise Detector ND-1 Operating Manual

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Agilent E5100A Network Analyzer

R&S ZN-Z154 Calibration Unit Specifications

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

TSH MHz Single Supply Video Buffer with Low In/Out Rail. Pin Connections (top view) Description. Applications. Order Codes

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Transcription:

SCOPE OF ACCREDITATION TO ISO/IEC 17025-2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 SIMCO ELECTRONICS 800 Pleasant Valley Drive Springboro, OH 45066 Doug Schonberg Phone: 937 746 7500 CALIBRATION Valid To: September 30, 2019 Certificate Number: 1395.02 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations and dimensional testing 1 : I. Dimensional Parameter/Equipment Range CMC 2, 5 ( ) Comments Gage Blocks Up to 4.0 in (>4.0 to 20) in (1.9 + 1.4L) in (3.3 + 1.7L) in Mechanical comparison using Federal comparator (0.005 to 6) in (1.1 + 0.65L) in Tsugami 3 interferometer Indicators Up to 1 in (26 + 2.4L) in Gage blocks Ring Gages (0.06 to 4) in (15 + 2.2L) in Sheffield w/ gage blocks Thread Plug Gages Major Diameter Pitch Diameter Up to 4 in (4 to 80) TPI (14 + 2.2L) µin (68 + 3.8L) µin Master Discs w/ thread wires and Zeiss ULM (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 1 of 21

Parameter/Equipment Range CMC 2, 5 ( ) Comments Adjustable Thread Ring Gages 3 Up to 2.5 in (W Class set plug tolerance) Master setting plug Thread Wire Size Wire Set (Constant) (4 to 80) TPI (11 + 2.2L) μin, 28 μin Zeiss ULM, master thread wires english set (0.3 to 6) mm (0.28 + 0.059L) μm, 0.70 μm Metric set Surface Roughness (5 to 120) in 2.9 in ASME B46.1 using Sheffield surface profilometer Micrometers 3 Linearity Up to 36 in (36 + 4.2L) in Gage blocks Flatness Up to 1 in 5.6 µin Optical flat Parallelism Up to 1 in 5.6 µin Optical parallel Height Gages 3 Up to 40 in (120 + 4.2L) in Gage blocks Depth Gages 3 Up to 12 in (120 + 4.2L) in Gage blocks Feeler Gages and Thickness Specimens Up to 1 in (20 + 1.5L) in Gage blocks with Zeiss ULM Calipers 3 Up to 40 in (90 + 4.2L) in Gage blocks Plug Gages and Master Setting Discs (0.01 to 4) in (14 + 2.2L) in Master discs with Zeiss ULM Surface Plates 3 Flatness (12 to 60) in 120 µin Planekator (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 2 of 21

Parameter/Equipment Range CMC 2, 5 ( ) Comments Optical Flats Flatness Up to 4 in Diameter 2.6 µin Van Keuren 10 in optical flat Parallelism Up to 4 in Diameter 3.7 µin Gage block comparator Angle Meters and Protractors (0 to 90) 0.03 + 0.6R Gage blocks and sine bar II. Dimensional Testing/Calibration 1 Parameter/Equipment Range CMC 2, 5 ( ) Comments Length 1D 7 Up to 4 in (>4 to 12) in (12 + 2.2L) in (20 + 2.5L) in Zeiss ULM with gage blocks III. Electrical DC/Low Frequency Parameter/Equipment Range CMC 2, 6 ( ) Comments DC Voltage Generate 3 (0 to 330) mv (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1000) V 20 V/V + 1 V 10 V/V + 2 V 9.9 V/V + 20 V 21 V/V + 0.15 mv 14 V/V + 1.5 mv Fluke 5520A/SC600 DC Voltage Measure 3 (0 to 100) mv (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 9.1 V/V + 0.3 V 9.5 V/V + 0.3 V 7.8 V/V + 0.5 V 11 V/V + 30 V 11 V/V + 0.1 mv* HP 3458A OPT-2 *add 12(V in /1000) 2 V/V to all V in > 100 (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 3 of 21

Parameter/Equipment Range CMC 2, 6 ( ) Comments DC High Voltage (1 to 90) kv 0.12 % + 0.000014 V Ross Engineering Measure 3 VD90-16.5Y-AK-KB- AL, Fluke 87III DC Current Generate 3 (0 to 330) A (0.33 to 3.3) ma (3.3 to 33) ma (33 to 330) ma (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20) A 0.014 % + 0.02 A 0.008 % + 0.05 A 0.009 % + 0.25 A 0.008 % + 2.5 A 0.018 % + 40 A 0.03 % + 40 A 0.04 % + 500 A 0.08 % + 750 A Fluke 5520A/SC600 (20 to 100) A 0.08 % + 750 A Valhalla 2555A DC Current Measure 3 (0 to 1) µa (1 to 10) µa (10 to 100) A (0.1 to 1) ma (1 to 10) ma (10 to 100) ma (0.1 to 1) A 280 A/A + 40 pa 40 A/A + 100 pa 56 A/A + 800 pa 23 A/A + 5 na 24 A/A + 50 na 41 A/A + 0.50 A 160 A/A + 1 A HP 3458A OPT-2 DC Current Clamp on Meters and Current Transformers 3 (20 to 300) A (300 to 1000) A 0.81 % 0.68 % Fluke 5520A/SC600, Fluke 5500A/Coil, HP 3458A OPT-2 DC Current Shunts 3 (0 to 100) A 0.032 % HP 3458A OPT-2 (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 4 of 21

Parameter/Equipment Range CMC 2, 6 ( ) Comments Resistance Generate 3 (0 to 11) (11 to 33) (33 to 110) (110 to 330) (0.33 to 1.1) k (1.1 to 3.3) k (3.3 to 11) k (11 to 33) k (33 to 110) k (110 to 330) k (0.33 to 1.1) M (1.1 to 3.3) M (3.3 to 11) M (11 to 33) M (33 to 110) M (110 to 330) M (0.33 to 1.1) G 0.0081 % + 1.0 m 0.005 % + 1.5 m 32 / + 1.4 m 26 / + 2.0 m 30 / + 2.0 m 26 / + 0.02 30 / + 0.02 26 / + 0.2 47 / + 0.2 37 / + 2 30 / + 2 0.006% + 30 0.013 % + 50 0.022 % + 2.5 k 0.032 % + 3 k 0.37 % + 0.10 M 1.2 % + 0.50 M Fluke 5520A/SC600 Resistance Measure 3 (0 to 10) (10 to 100) (0.1 to 1) k (1 to 10) k (10 to 100) k (0.1 to 1) M (1 to 10) M (10 to 100) M (100 to 1000) M 40 / + 50 23 / + 0.5 m 17 / + 0.5 m 17 / + 5.0 m 18 / + 50 m 28 / + 2 89 / + 100 0.06 % + 1 k 0.6 % + 10 k HP 3458A OPT-2 (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 5 of 21

Parameter/Equipment Range CMC 2 ( ) Comments Oscilloscopes 3 Level Sine Amp 50 khz ref 10 mv to 5 V (p-p) 2.3 % + 300 V Fluke 5520A/SC600 Level Sine Flatness 5 mv to 5.5 V Relative to 50 khz Reference Bandwidth 50 khz to 100 MHz (100 to 300) MHz (300 to 600) MHz 2.3 % + 100 V 2.9 % + 100 V 4.9 % + 100 V DC Signal Level Up to 130 V Up to 6.6 V 0.06 % + 40 µv 0.29 % + 40 µv Into 1 M load Into 50 load Time Marker Output into 50 2 ns to 20 ms 50 ms to 5 s 3 parts in 10 6 (29 + 1000t) s/s Fluke 5520A/SC600 t = time in seconds Pulse Rise Time 0.5 V, 1 V (p-p) 1 V (p-p) 10 MHz 1 MHz 160 ps 160 ps Square Wave Generate 50 Ω (0.01 to 10) khz 1 MΩ (0.01 to 1) khz 1 MΩ (1 to 10) khz 1mV to 6.6 V (p-p) 1mV to 130 V (p-p) 1mV to 130 V (p-p) 0.29 % + 40 µv 0.14 % + 40 µv 0.29 % + 40 µv Edge Transition Time 1 khz to 10 MHz 120 ps (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 6 of 21

Parameter/Range Frequency CMC 2, 6 ( ) Comments Phase Angle Generate 3 3.0 V/ 0.5 V (All at 0 ) (10 to 65) Hz (65 to 400) Hz 400 Hz to 1 khz (1 to 5) khz (5 to 10) khz (10 to 30) khz 0.23 0.30 0.50 2.3 4.6 9.2 Fluke 5520A/SC600 Capacitance Generate 3 (0.19 to 0.3999) nf (0.4 to 1.0999) nf (1.1 to 3.2999) nf (3.3 to 10.9999) nf (11 to 32.9999) nf (33 to 109.999) nf (110 to 329.999) nf (0.33 to 1.09999) µf (1.1 to 3.29999) µf (3.3 to 10.9999) µf (11 to 32.9999) µf (33 to 109.999) µf (110 to 329.999) µf (0.33 to 0.7) mf 0.39 % + 10 pf 0.60 % + 10 pf 0.63 % + 10 pf 0.27 % + 10 pf 0.26 % + 0.1 nf 0.24 % + 0.1 nf 0.29 % + 0.3 nf 0.24 % + 1.0 nf 0.20 % + 3.0 nf 0.21 % + 10 nf 0.33 % + 30 nf 0.43 % + 0.1 µf 0.36 % + 0.3 µf 0.36 % + 1.0 µf Fluke calibrator 5520A (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 7 of 21

Parameter/Equipment Range CMC 2 ( ) Comments Electrical Simulation of Thermocouples Generate/Measure 3 Type E -250 C to -100 C -100 C to -25 C -25 C to 350 C 350 C to 650 C 650 C to 1000 C 0.58 C 0.19 C 0.17 C 0.19 C 0.25 C Fluke 5520A Type J -210 C to -100 C -100 C to -30 C -30 C to 150 C 150 C to 760 C 760 C to 1200 C 0.32 C 0.32 C 0.18 C 0.22 C 0.28 C Type K -200 C to -100 C -100 C to -25 C -25 C to 120 C 120 C to 1000 C 1000 C to 1372 C 0.39 C 0.22 C 0.20 C 0.31 C 0.47 C Type S 0 ºC to 250 ºC 250 ºC to 1000 ºC 1000 ºC to 1400 ºC 1400 ºC to 1767 ºC 0.55 ºC 0.42 ºC 0.44 ºC 0.54 ºC Type T -250 C to -150 C -150 C to 0 C 0 C to 120 C 120 C to 400 C 0.74 C 0.30 C 0.21 C 0.19 C (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 8 of 21

Parameter/Range Frequency CMC 2, 6 ( ) Comments AC Voltage Generate 3 (1 to 33) mv (10 to 45) Hz 45 Hz to 10 khz (10 to 20) khz (20 to 50) khz (50 to 100) khz (100 to 500) khz 0.091 % + 6 V 0.058 % + 6 V 0.049 % + 6 V 0.12 % + 6 V 0.30 % + 12 V 0.71 % + 50 V Fluke 5520A/SC600 (33 to 330) mv (10 to 45) Hz 45 Hz to 10 khz (10 to 20) khz (20 to 50) khz (50 to 100) khz (100 to 500) khz 0.024 % + 8 V 0.012 % + 8 V 0.014 % + 8 V 0.029 % + 8 V 0.063 % + 32 V 0.16 % + 70 V (0.33 to 3.3) V (10 to 45) Hz 45 Hz to 10 khz (10 to 20) khz (20 to 50) khz (50 to 100) khz (100 to 500) khz 0.024 % + 50 V 0.013 % + 60 V 0.02 % + 60 V 0.024 % + 50 V 0.056 % + 0.13 mv 0.19 % + 0.60 mv (3.3 to 33) V (10 to 45) Hz 45 Hz to 10 khz (10 to 20) khz (20 to 50) khz (50 to 100) khz 0.024 % + 0.65 mv 0.013 % + 0.6 mv 0.019 % + 0.6 mv 0.028 % + 0.6 mv 0.071 % + 1.6 mv (33 to 330) V 45 Hz to 1 khz (1 to 10) khz (10 to 20) khz (20 to 50) khz (50 to 100) khz 0.02 % + 2 mv 0.02 % + 6 mv 0.02 % + 6 mv 0.028 % + 6 mv 0.16 % + 50 mv (330 to 1020) V 45 Hz to 1 khz (1 to 5) khz (5 to 10) khz 0.024 % + 10 mv 0.02 % + 10 mv 0.024 % + 10 mv (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 9 of 21

Parameter/Range Frequency CMC 2, 6 ( ) Comments AC Voltage Measure 3 (1 to 10) mv (1 to 40) Hz 40 Hz to 1 khz (1 to 20) khz (20 to 50) khz (50 to 100) khz (100 to 300) khz 0.08 % + 3.0 V 0.07 % + 1.1 V 0.07 % + 1.1 V 0.16 % + 1.1 V 0.58 % + 1.1 V 4.5 % + 2.0 V HP 3458A OPT-2 (10 to 100) mv (1 to 40) Hz 40 Hz to 1 khz (1 to 20) khz (20 to 50) khz (50 to 100) khz (100 to 300) khz (0.3 to 1) MHz 0.01 % + 4.0 V 0.01 % + 2.0 V 0.018 % + 2.0 V 0.036 % + 2.0 V 0.093 % + 2.0 V 0.35 % + 10 V 1.2 % + 10 V (0.1 to 1) V (1 to 40) Hz 40 Hz to 1 khz (1 to 20) khz (20 to 50) khz (50 to 100) khz (100 to 300) khz (0.3 to 1) MHz 0.0081 % + 40 V 0.0082 % + 20 V 0.017 % + 20 V 0.036 % + 20 V 0.093 % + 20 V 0.35 % + 0.10 mv 1.2 % + 0.10 mv (1 to 10) V (1 to 40) Hz 40 Hz to 1 khz (1 to 20) khz (20 to 50) khz (50 to 100) khz (100 to 300) khz (0.3 to 1) MHz 0.0093 % + 0.40 mv 0.0081 % + 0.20 mv 0.017 % + 0.20 mv 0.036 % + 0.20 mv 0.093 % + 0.20 mv 0.35 % + 1.0 mv 1.2 % + 1.0 mv (10 to 100) V (1 to 40) Hz 40 Hz to 1 khz (1 to 20) khz (20 to 50) khz (50 to 100) khz (100 to 300) khz 0.024 % + 4.0 mv 0.024 % + 2.0 mv 0.024 % + 2.0 mv 0.041 % + 2.0 mv 0.14 % + 2.0 mv 0.46 % + 10.0 mv (100 to 700) V (1 to 40) Hz 40 Hz to 1 khz (1 to 20) khz (20 to 50) khz (50 to 100) khz 0.05 % + 40 mv 0.05 % + 20 mv 0.07 % + 20 mv 0.14 % + 20 mv 0.35 % + 20 mv AC High Voltage 3 Measure @ 60 Hz (1 to 60) kv 0.0058 V/V + 0.000043 V Ross Engineering VD90-16.5Y-AK- KB-AL, Fluke 87III (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 10 of 21

Parameter/Range Frequency CMC 2, 6 ( ) Comments AC Current Generate 3 (29 to 330) µa 0.13 % + 0.10 µa Fluke 5520A/SC600 (0.33 to 3.3) ma (3.3 to 33) ma (>1 to 5) khz (>1 to 5) khz 0.035 % + 0.15 µa 0.16 % + 0.20 µa 0.035 % + 2 µa 0.064 % + 2 µa *For compliance voltages >1V, add 1mA/V to floor specification (33 to 330) ma (>1 to 5) khz 0.035 % + 20 µa 0.08 % + 50 µa (0.33 to 1.1) A (>1 to 5) khz 0.05 % + 0.1 ma 0.47 % + 1.0 ma* (1.1 to 3.0) A (>1 to 5) khz 0.084 % + 0.1 ma 0.47 % + 1.0 ma* (3.0 to 11.0) A (>1 to 5) khz 0.095 % + 2.0 ma 2.3 % + 2.0 ma (11.0 to 20.5) A (>1 to 5) khz 0.13 % + 5.0 ma 2.4 % + 5.0 ma AC Current Measure 3 (5 to 100) µa 0.072 % + 30 na HP 3458A OPT-2 (0.1 to 1) ma (0.1 to 5) khz 0.071 % + 200 na 0.036 % + 200 na (1 to 10) ma (0.1 to 5) khz 0.070 % + 2 µa 0.036 % + 2 µa (10 to 100) ma (0.1 to 5) khz 0.070 % + 20 µa 0.036 % + 20 µa (0.1 to 1) A (0.1 to 5) khz 0.093 % + 200 µa 0.12 % + 200 µa AC Current Clamp-on Meter 3 (20 to 300) A (50 to 100) Hz (100 to 400) Hz 0.84 % 1.3 % Fluke 5520A/SC600, Fluke 5500A/Coil (300 to 1000) A (50 to 100) Hz (100 to 400) Hz 0.7 % 1.4 % (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 11 of 21

Parameter/Range Frequency CMC 2, 6 ( ) Comments AC Power Generate 3 (0.01 to 0.1) W (0.1 to 890) W (0.89 to 3) kw (3 to 11) kw (11 to 20.4) kw (45 to 65) Hz; PF=1 0.23 % 0.14 % 0.13 % 0.27 % 0.27 % Fluke 5520A/SC600 III. Electrical RF/Microwave Parameter/Range Frequency CMC 2, 6 Comments Amplitude Modulation Frequency: 150 khz to 10 Measure 3 MHz Rate: 50 Hz to 10 khz Depth: (5 to 99) % Rate: 20 Hz to 10 khz Depth: to 99 % Frequency: >10 MHz to 1.3 GHz Rate: 50 Hz to 50 khz Depth: (5 to 99) % Rate 20 Hz to 100 khz Depth: to 99 % Frequency: >(1.3 to 26.5) GHz Rate: 50 Hz to 50 khz Depth: (5 to 99) % Rate: 20 Hz to 100 khz Depth: to 99 % 2.4 % + 1 digit 3.6 % + 1 digit 1.4 % + 1 digit 3.6 % + 1 digit 1.9 % + 1 digit 3.6 % + 1 digit HP 8902A measuring receiver with 11722/92A sensor & 11793 mixer (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 12 of 21

Parameter/Range Frequency 4 CMC 2, 5, 6 Comments Frequency Modulation Frequency: 250 khz, 10 Measure 3 MHz HP 8902A measuring receiver Rate: 20 Hz to 10 khz Dev: <40 khz/pk 2.3 % + 1 digit Frequency: 10 MHz to 1.3 GHz Rate: 50 Hz to 100 khz Dev: <400 khz/pk Rate: 20 Hz to 200 khz Dev: <400 khz/pk 1.2 % + 1 digit 5.8 % + 1 digit Distortion Measure 3 >90 dbc (0.02 to 20) khz (20 to 100) khz 1.2 db 2.4 db HP 8903B Frequency Response 3 (Flatness) (1 to 20) MHz @ 1 Vrms (>20 to 50) MHz @ 1 Vrms (>50 to 100) MHz @ 1 Vrms (1 to 20) MHz @ 3 Vrms (>20 to 50)MHz @ 3 Vrms (>50 to 100) MHz @ 3 Vrms 0.16 % 0.61 % 1.8 % 0.48 % 0.75 % 1.4 % Thermal converters and DMM (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 13 of 21

Parameter/Range Frequency CMC 2, 5, 6 Comments Phase Modulation Measure 3 Frequency: 150 khz to 10 MHz Rate: 200 Hz to 10 khz 4 % + 0.015 rad HP 8902A measuring receiver w/ HP 11792A sensor Frequency: 10 MHz to 26.5 GHz Rate: 20 Hz to 200 khz 5 % + 0.019 rad RF Power Generate 3 Attenuator Range (13 to -5) db (-5 to -45) db (-45 to -85) db 200 Hz to 80 MHz 0.08 dbm 0.12 dbm 0.24 dbm HP 3335A (+10 to -9.95) dbm (-10 to -19.95) dbm (-20 to -49.95) dbm (-50 to -79.95) dbm (-80 to -100) dbm (-100 to -110) dbm Band 0 (0.01 to <2.3 GHz) 1.1 db 1.4 db 1.8 db 2.1 db 2.5 db 3.4 db HP 8340B (+10 to -9.95) dbm (-10 to -19.95) dbm (-20 to -49.95) dbm (-50 to -79.95) dbm (-80 to -100) dbm (-100 to -110) dbm Band 1 to 3 (2.3 to 20) GHz 1.8 db 2.4 db 2.7 db 3.1 db 3.4 db 4.3 db (+10 to -9.95) dbm (-10 to -19.95) dbm (-20 to -49.95) dbm (-50 to -79.95) dbm (-80 to -100) dbm (-100 to -110) dbm Band 4 (20 to 26.5) GHz 2.4 db 3.0 db 3.3 db 3.7 db 4.0 db 4.9 db (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 14 of 21

Parameter/Range Frequency CMC 2 Comments RF Attenuation Measure 3 100 khz to 1.3 GHz (0 to 10) db (>10 to 20) db (>20 to 30) db (>30 to 40) db (>40 to 50) db (>50 to 60) db (>60 to 70) db (>70 to 80) db (>80 to 90) db (>90 to 100) db (>100 to 110) db 0.064 db 0.068 db 0.079 db 0.094 db 0.12 db 0.14 db 0.16 db 0.20 db 0.22 db 0.24 db 0.33 db HP 8902A measuring receiver w/ 11722A sensor (>1.3 to 18) GHz (0 to 10) db (>10 to 20) db (>20 to 30) db (>30 to 40) db (>40 to 50) db (>50 to 60) db (>60 to 70) db (>70 to 80) db (>80 to 90) db (>90 to 100) db (>100 to 110) db 0.078 db 0.081 db 0.091 db 0.10 db 0.13 db 0.15 db 0.17 db 0.20 db 0.22 db 0.32 db 0.33 db HP 8902A measuring receiver w/ 11792A sensor (>18 to 26.5) GHz (0 to 10) db (>10 to 20) db (>20 to 30) db (>30 to 40) db (>40 to 50) db (>50 to 60) db (>60 to 70) db (>70 to 80) db (>80 to 90) db (>90 to 100) db (>100 to 110) db 0.094 db 0.097 db 0.11 db 0.12 db 0.14 db 0.16 db 0.17 db 0.21 db 0.23 db 0.32 db 0.34 db (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 15 of 21

Parameter Range CMC 2, 5 Comments Tuned RF Power 3 100 khz to 1.3 GHz (+10 to 0) dbm (<0 to -10) dbm (<-10 to -20) dbm (<-20 to -30) dbm (<-30 to -40) dbm (<-40 to -50) dbm (<-50 to -60) dbm (<-60 to -70) dbm (<-70 to -80) dbm (<-80 to -90) dbm (<-90 to -100) dbm (<-100 to -110) dbm (<-110 to -120) dbm 2.2 % 2.2 % 2.4 % 2.7 % 3.2 % 3.6 % 4.0 % 4.9 % 5.3 % 5.8 % 6.2 % 6.7 % 9.4 % HP 8902A measuring receiver with 11722A sensor >(1.3 to 18) GHz (+10 to 0) dbm (<0 to -10) dbm (<-10 to -20) dbm (<-20 to -30) dbm (<-30 to -40) dbm (<-40 to -50) dbm (<-50 to -60) dbm (<-60 to -70) dbm (<-70 to -80) dbm (<-80 to -90) dbm (<-90 to -100) dbm (<-100 to -110) dbm (<-110 to -120) dbm 2.4 % 2.5 % 2.6 % 2.9 % 3.4 % 3.8 % 4.2 % 5.0 % 5.4 % 5.9 % 8.0 % 8.4 % 9.4 % >(18 to 26.5) GHz (+10 to 0) dbm (<0 to -10) dbm (<-10 to -20) dbm (<-20 to -30) dbm (<-30 to -40) dbm (<-40 to -50) dbm (<-50 to -60) dbm (<-60 to -70) dbm (<-70 to -80) dbm (<-80 to -90) dbm (<-90 to -100) dbm (<-100 to -110) dbm (<-110 to -120) dbm 2.6 % 2.7 % 2.8 % 3.1 % 3.1 % 3.3 % 3.5 % 4.2 % 4.3 % 4.5 % 4.7 % 5.0 % 7.6 % (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 16 of 21

IV. Mechanical Parameter/Equipment Range 4 CMC 2, 5 ( ) Comments Accelerometers (10 to 99) Hz 100 Hz (101 to 920) Hz (921 to 5000) Hz (5001 to 10 000) Hz (10 to 15) khz (15 to 20) khz 0.82 % 0.63 % 0.78 % 0.92 % 1.6 % 1.6 % 2.1 % Data acquisition card w/ 9155D-831 air bearing shaker Acceleration Amplitude Linearity, Shock (20 to 2000) g (2000 to 10 000) g 2.0 % 2.1 % Data acquisition card w/ 9155D-525 shock calibrator Scales & Balances 3 (0.001 to 500) g 1 kg 2 kg 5 kg 10 kg 20 kg (>20 to 40) kg 0.5 lb 1.0 lb 2.0 lb 5.0 lb 10 lb 20 lb 25 lb 50 lb (>50 to 325) lb 1.0 mg + 0.6R 3.9 mg + 0.6R 4.0 mg + 0.6R 6.3 mg + 0.6R 14 mg + 0.6R 26 mg + 0.6R 30 mg + 0.6R 45 mg + 0.6R 70 mg + 0.6R 91 mg + 0.6R 230 mg + 0.6R 450 mg + 0.6R 910 mg + 0.6R 1.1 g + 0.6R 2.3 g + 0.6R 5.1 g + 0.6R Ultra-Class weights Class F weights Rotation Measure 3 (Belt Speed, Line Speed, and Centrifuges) (6 to 99 999) rpm 0.03 % of rdg + 0.6R Reference tachometer (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 17 of 21

Parameter/Equipment Range 4 CMC 2, 5 ( ) Comments Force Measuring Equipment 3 0.5 lbf 1 lbf 2 lbf 5 lbf 10 lbf 20 lbf 25 lbf 50 lbf (>50 to 325) lbf 45 mg + 0.6R 70 mg + 0.6R 91 mg + 0.6R 230 mg + 0.6R 450 mg + 0.6R 910 mg + 0.6R 1.1 g + 0.6R 2.3 g + 0.6R 5.1 g + 0.6R Class F weights Analytical Balances 3 1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 200 mg 500 mg 1.7 g + 0.6R 1.7 g + 0.6R 1.7 g + 0.6R 2.0 g + 0.6R 2.0 g + 0.6R 2.0 g + 0.6R 2.0 g + 0.6R 2.0 g + 0.6R 2.0 g + 0.6R Class E1 mass set 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 5 kg 10 kg 3.1 g + 0.6R 3.5 g + 0.6R 3.5 g + 0.6R 5.3 g + 0.6R 6.2 g + 0.6R 7.2 g + 0.6R 15 g + 0.6R 0.072 mg + 0.6R 0.090 mg + 0.6R 0.16 mg + 0.6R 0.26 mg + 0.6R 0.51 mg + 0.6R 2.4 mg + 0.6R (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 18 of 21

Parameter/Equipment Range 4 CMC 2, 5 ( ) Comments Mass Measure 1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 200 mg 500 mg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 5 kg 10 kg 1.4 g 1.9 g 1.9 g 1.9 g 2.3 g 2.3 g 2.3 g 4.8 g 4.8 g 7.5 g 9.3 g 11 g 12 g 13 g 17 g 17 g 49 µg 0.11 mg 0.14 mg 1.2 mg 1.5 mg 2.2 mg Mettler Toledo PR10003, AT1005, AT106 mass comparators and class E1 mass set Pressure 3 Measuring Equipment (-14.5 to 300) psig 0.12 psig + 0.58R Druck PM620 Nitrogen Gas (>300 to 500) psig (>500 to 1000) psig 0.31 psig + 0.58R 0.52 psig + 0.58R Eaton UPC5000 pressure calibrator Torque Wrenches 3 (5 to 50) inozf (2.5 to 25) inlbf (25 to 250) inlbf (20 to 250) ftlbf 0.68 % + 0.58R 0.96 % + 0.58R 0.59 % + 0.58R 0.58 % + 0.58R AWS Torque Transducers Torque Measuring Equipment 3 (1 to 50) inozf (1 to 600) inlbf (0 to 50) inlbf (50 to 100) ftlbf 0.16 % 0.32 % 0.32 % 0.4 % Calibration arms & weights (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 19 of 21

V. Thermodynamics Parameter/Equipment Range CMC 2, 5 ( ) Comments Relative Humidity Measure 3 (0 to 90) % RH (90 to 100) % RH 1.0 % RH 2.0 % RH Vaisala MI70 w/ HMP75 Temperature (-45 to 150) C 0.051 C Omega DP-97 plus Measuring Equipment 3 Isotech Fast-CAL temperature bath Temperature (-50 to 250) C 0.051 C Omega DP-97 Measure 3 Infrared Thermometers 3 (25 to 100) C (>100 to 500) C (>500 to 982) C 0.61 C 0.95 C 0.25 % + 1.8 C Fluke and Omega Blackbody source VI. Time & Frequency Parameter/Equipment Range CMC 2, 5 ( ) Comments Frequency Measuring DC to 26.5 GHz 0.0011 HZ Agilent Z3805A Equipment 3 GPS receiver Frequency Measure 3 DC to 12.4 GHz (>12.4 to 26.5) GHz 0.0091 Hz 1.5 Hz Counter locked to Agilent Z3805A GPS receiver Timers/Stopwatches 3 1 s to 6 hr 39 ms Agilent Z3805A GPS receiver Tachometer Optical (60 to 200 000) rpm 0.002 % + 0.6R Agilent 3325B Pickup 3 (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 20 of 21

1 This laboratory offers commercial calibration, dimensional testing and field calibration service. 2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer s site being larger than the CMC. 4 Where ranges are not specified, the CMC stated is for the cardinal points only. 5 In the statement of CMC, R is the numerical value of the resolution of the device. In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. In the statement of CMC, adjustable thread rings are set to applicable specifications using calibrated master set plug gages. In the statement of CMC, percentages are percent of reading, unless otherwise indicated. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 7 This laboratory meets R205 Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. (A2LA Cert. No. 1395.02) Revised 10/31/2018 Page 21 of 21

Accredited Laboratory A2LA has accredited SIMCO ELECTRONICS Springboro, OH for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of ANSI/NCSLI Z540-1-1994 and the requirements of ANSI/NCSLI Z540.3-2006 and R205 Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 30 th day of August 2017. President and CEO For the Accreditation Council Certificate Number 1395.02 Valid to September 30, 2019 For the calibrations to which this accreditation applies, please refer to the laboratory s Calibration Scope of Accreditation.