SignalOn Series. L-Band Splitter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

Similar documents
SignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

D3.1/CCAP Compliant HFC. Enhance. QHFCN CATV Optical 2-way Mini Node INSTALLATION & OPERATION MANUAL.

QFMN. QFMN Fiber Mini Node Distribution Amplifier INSTALLATION & OPERATION MANUAL.

QFN. QFN Fiber Node INSTALLATION & OPERATION MANUAL.

HFC. Enhance. QHFCN CATV Optical 2-way Mini Node Installation & Operation Guide

DVIS. DVIS - Digital Video Insertion System. Quick Start Guide. Patent Pending

ReKEY Nano Pro:Idiom Refresh Device

ZvBox 150. HD video distribution over COAX Get Going Guide

DVISm. DVISm - Mini Digital Video Insertion System. Quick Start Guide. Patent Pending

HD Digital MPEG2 Encoder / QAM Modulator Get Going Guide

OptEnet OC48 Regenerator Module User Manual

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Register your product and get support at SDV5122/27. EN User manual

HD Digital MPEG2 Encoder / QAM Modulator


HD Digital MPEG2 Encoder / QAM Modulator

Model 1421 Distribution Amplifier

Wired to Wireless Camera Converter

Operating Instructions

Wireless 4 Channel Receiver with 2 Night Vision cameras

D3.1 / CCAP Compliant. Forward Combining Amplifier Specifications IL ISO (4) (-db) (-db) Plug-in

ChromaFlex. ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules HARDWARE INTERFACE MANUAL.

4 PORT HDMI SWITCH

User Manual CVA3. HDMI Audio Decoder. All Rights Reserved. Version: CVA3_2016V1.0

INSTRUCTION MANUAL. ANI-1x2COMPDA. 1x2 Component Video(RCA) Splitter Distribution Amplifier w/ Digital Coaxial/Optical Audio

Evolution Digital HD Set-Top Box Important Safety Instructions

SAFETY INFORMATION. 7. Do not force switched or external connections in any way. They should all connect easily, without needing to be forced.

*Prefer. 600 MHz 4K ULTRA. 60Hz, 4:4:4. over one SC-Terminated Fiber-Optic Cable EXT-DP-4K600-1SC. User Manual. Release A1

ATTACHING & REMOVING THE BASE

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

HD Digital Set-Top Box Quick Start Guide

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

Model 1606 Super. User Manual

By CHANNEL VISION. Flush Mount Amplifier A0350

2.4 GHz WIRELESS VIDEO SENDER SYSTEM MODEL: VS6234

SYNC/VIDEO, SYNC FOR MULTI-TASKER MATRIX SWITCHER USER S GUIDE

2.0 Wall Mount TV Soundbar Instruction Manual

Multi-Channel Passive Transceiver Hubs Installation Sheet

Golf ball tracker. Instruction manual

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz


SW 50. Powered Subwoofer with Built-in Stereo Crossover

BP2-MM MM Phono Preamplifier Owner s Manual

Model Camera System (CCTV) User Manual

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

BP2-MM/MC Phono Preamplifier Owner s Manual

Amplified TV Antenna VIDEO. Band Separator. Matching Transformer. 120 VAC, 60 Hz to 12 VDC, 200mA Wall Adapter ANT200

384A Adapter Installation Instructions

Model /29S RF Splitter

E325 Series User Guide

User Guide. Centrex Recording Interface

OPERATING INSTRUCTIONS TOM-0431IP

SKYPLAY-MX Installation and Operation Guide

Zigen ZIG-ADM. 4K UHD+ Dolby Digital & DTS Stereo Decoder. 4K 60 Hz 4:4:4 HDCP 2.2 ZigNet, Full Web Interface and System Diagnostics

DisplayPort Extender over 2 LC Fibers

QCA9-33 Active Combiner

ASH - EOC-01. Ethernet Over Coax Adapter User Guide

Modulator Installation Manual

English. User Manual sub8 Subwoofer SUBWOOFER. Supporting your digital lifestyle

SB-2809 or SB S-Video / Composite / Audio Booster INSTRUCTION MANUAL. SB-2810 (Video-RCA) SB-2809 (Video-BNC)

User Manual TP70L. HDBaseT Extender. All Rights Reserved. Version: TP70L2016V1.1

QDA4-44 RF Amp/Combiner

MON8-1 1U 8-Channel Multi-Display Video Monitor

VLHDMIEXTFIB_2017V1.0

Installation Manual VIP 1003

DisplayPort Extender over 2 LC Fibers

INSTRUCTION MANUAL SB x2 Auto Switching Composite Video/Stereo Audio Switch

1812R Blues King 12. User Manual

TranScend Opto-Stacker & Destacker. Operation Manual

Monochrome Video Monitors

Power Injector 1520 Series

5 Port DVI Splitter VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES

PT-C-HDADE. User Manual. HDMI Audio De-Embedder 4K (60Hz 4:4:4) Model PT-C-HDADE. Designed in Germany

Copyright Black Box Corporation. All rights reserved.

AS-300D Series Smart Bench Scales Owner s Manual

opengear OPG-1L 50 MHz-2.3 GHz

INSTALLATION MANUAL VIP 1903 / VIP 1903 T VIP 1963 / VIP 1963 T

Content. User s Manual 3. Owner s Manual Ver. 1.1 / June Introduction...4. Mytek Package Content Features...

8 Port HD/SD-SDI Switch

Personal Q Guide for VENUE Systems

EXT-UHD600-1SC Version A1

HID-C10 Important Information Guide

DM-1CH SD DVB-T MODULATOR INSTRUCTION MANUAL

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide

Passport Player Owner s Manual

E246 Series User Guide

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

MT IN, 2-OUT CAT-5 TO VGA RECEIVER CARD FOR MULTI-TASKER USER S GUIDE

MON8-1/SDI 1U 8-Channel SDI Digital Multi-Display Video Monitor

User Manual TL-TP70-HDIR 70m Extender with ARC and IR All Rights Reserved Version: TL-TP70-HDIR_180723

APSPB PUSH BUTTON ZERO Installation Manual

Picture Fan. display your photos, graphics & messages

SpectraPulse Ultra Wideband Wireless Microphone System

Disclaimer. Trademarks. Copyright. Contact Us Control4 Corporation S. Election Road Salt Lake City, UT USA

CON-AUDXTRACT USER MANUAL

1X4 HDMI Splitter with 3D Support

TS2.8 Sub OWNER S MANUAL

COMMODORE 1802 COLOR MONITOR USER'S GUIDE

Transcription:

SignalOn Series D3.1/CCAP Compliant 1.2 GHz L-Band Splitter Module INSTALLATION & OPERATION MANUAL www.atxnetworks.com www.atxnetworks.com

Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions. Specifications subject to change without notice. SignalOn Series, MAXNET, HFC Enhance, PCI Filters, Q-Series & FiberLinx are registered trademarks of ATX in the United States and/or other countries. SMAC SM is a service mark of ATX in the United States and/or other countries. Products or features contained herein may be covered by one or more U.S. or foreign patents. Other non-atx product and company names in this manual are the property of their respective companies.

TABLE OF CONTENTS Page Introduction... iii Admonishments... iii General Safety Precautions... iii Certification... iii FCC Compliance Statement... iii 1. GENERAL... 1-1 2. PRODUCT DESCRIPTION... 2-1 3. SPECIFICATIONS... 3-1 3.1. Functional Diagram... 3-3 4. INSTALLATION... 4-1 5. SERVICE & SUPPORT... 5-1 5.1. Contact ATX Networks... 5-1 5.2. Warranty Information... 5-1 5.3. Safety... 5-1 SignalOn Series L-Band Splitter Module Installation & Operation Manual i

Index of Tables Tables #1 Power Passing Ports...2-1 Figures #1 2 way Splitter Functional Diagram...3-3 #2 4 way Splitter Functional Diagram...3-3 #3 8 way Splitter Functional Diagram...3-3 ii SignalOn Series L-Band Splitter Module Installation & Operation Manual

PREFACE Introduction The SignalOn Series L-Band Module is designed to be installed in the 4-, 8-, or 20-position SignalOn Series chassis. Each module occupies one positions in the chassis. The mechanical dimensions, cable management, and aesthetics of the L-Band Module are compatible with the SignalOn product line. The system is designed to accommodate superior cable management and ease of use. Admonishments Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment. An admonishment identifi es a possible hazard and then explains what may happen if the hazard is not avoided. The admonishments in the form of Dangers, Warnings, and Cautions must be followed at all times. These warnings are fl agged by use of the triangular alert icon (seen below), and are listed in descending order of severity of injury or damage and likelihood of occurrence. Danger: Danger is used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Warning: Warning is used to indicate the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Caution: Caution is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided. General Safety Precautions Warning: Wet conditions increase the potential for receiving an electrical shock when installing or using electrically-powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm. Certification SignalOn Forward Path products have been tested and found to comply with the requirements of UL 60950, and CSA 22.2 No. 0.7, emissions EN55022 radiated and conducted. FCC Compliance Statement The SignalOn Forward Path Amplifi er product line has been certifi ed to comply with the requirements for class A computing devices per part 15 of the FCC regulations. Warning: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with limits for a Class A digital device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference to TV and radio reception in which case the user, at their own expense, will be required to take whatever measures may be required to correct the interference. This equipment does not exceed Class A limits for radio emission for digital apparatus, set out in the radio interference regulation of the authorization methods of Industry Canada. Operation in a residential area may cause unacceptable interference to TV and radio reception requiring the owner or operator to take whatever steps are necessary to correct the interference. SignalOn Series L-Band Splitter Module Installation & Operation Manual iii

PREFACE This page left intentionally blank. iv SignalOn Series L-Band Splitter Module Installation & Operation Manual

CHAPTER 1: GENERAL GENERAL 1. General The SignalOn system is a modular system that permits high isolation splitting and switching of headend signals in a CATV system. The system is designed to accommodate strong cable management, EMI shielding, and ease of use. This facilitates easy reconfi guration and high performance within a dynamic headend environment. The SignalOn L-Band Splitter Module is designed for use with the SignalOn 4-position, 8-position, or 20-position chassis. All RF connections to the splitter are made through standard 75 Ohm BNC, or F connectors located on the rear. Each SignalOn Splitter Module occupies one position in a chassis. A splitter module is shown on the front of this publication. Each module can be used as either a splitter or a combiner. SignalOn Series L-Band Splitter Module Installation & Operation Manual 1-1

CHAPTER 1: GENERAL This page left intentionally blank. 1-2 SignalOn Series L-Band Splitter Module Installation & Operation Manual

CHAPTER 2: PRODUCT DESCRIPTION PRODUCT DESCRIPTION 2. Product Description L-Band microwave signals operating in the 950 MHz to 2.145 GHz frequency band are received from a satellite downlink antenna. Signals are then typically fed to multiple satellite receivers such as analog receivers, analog Integrated Receiver/ Decoders or digital Integrated Receiver/Transcoders. When these multiple receiving devices are fed from the same satellite antenna, it is necessary to split the downlink signal into several equal outputs. These split signals are then fed to each receiving device individually. Each splitter configuration has two ports that pass DC voltage(s) from the receiver(s) assigned to supply power to the Low Noise Block (LNB). Table 1 shows the power pass port assignment for each individual module type. MODULE TYPE DC POWER PASSING PORTS MAXIMUM POWER RATING 2 way 1 & 2 24 VDC at 1 Ampere 4 way 1 & 4 24 VDC at 1 Ampere 8 way 1 & 8 24 VDC at 1 Ampere Table #1: Power Passing Ports SignalOn Series L-Band Splitter Module Installation & Operation Manual 2-1

CHAPTER 2: PRODUCT DESCRIPTION This page left intentionally blank. 2-2 SignalOn Series L-Band Splitter Module Installation & Operation Manual

CHAPTER 3: SPECIFICATIONS SPECIFICATIONS 3. Specifications Please refer to the SignalOn L-Band Satellite Splitter Modules data sheet located at atxnetworks.com for specifications. 3.1. Functional Diagrams PASS 1 PASS 2 2-way Splitter Figure #1: 2-way Splitter Functional Diagram PASS 1 2 3 PASS 4 4-way Splitter Figure #2: 4-way Splitter Functional Diagram 8-way Splitter PASS PASS 1 2 3 4 5 6 7 8 Figure #3: 8-way Splitter Functional Diagram SignalOn Series L-Band Splitter Module Installation & Operation Manual 3-1

CHAPTER 3: SPECIFICATIONS This page left intentionally blank. 3-2 SignalOn Series L-Band Splitter Module Installation & Operation Manual

CHAPTER 4: INSTALLATION INSTALLATION 4. Installation Each splitter module occupies a single slot in the chassis. Use the following procedure to install modules in the SignalOn Series chassis. 1. Make sure the ATX logo (or any other front panel lettering) is readable. Slide the plug-in module into its designated location in the chassis. Warning: Never install equipment in a wet location or during a lightning storm. 2. Secure the module using its two captive retaining screws. 3. After each module is loaded into the chassis, refer to your work order, and connect the designated RF cables to the appropriate BNC or F connectors on the modules in the chassis. 4. Carefully route cables through the cable management slots located on each side of the rear of the chassis. Use the cable management guidelines found in this manual to route cable from the chassis to the rack/cabinet. 5. Perform any cabling or operational tests required at your facility. SignalOn Series L-Band Splitter Module Installation & Operation Manual 4-1

CHAPTER 4: INSTALLATION This page left intentionally blank. 3-4 SignalOn Series L-Band Splitter Module Installation & Operation Manual

CHAPTER 5: SERVICE & SUPPORT SERVICE & SUPPORT 5. Service & Support 5.1. Contact ATX Networks Please contact ATX Technical Support for assistance with any ATX products. Please contact ATX Customer Service to obtain a valid RMA number for any ATX products that require service and are in or out-of-warranty before returning a failed module to the factory. RF Products (MAXNET, SignalOn, HFC Enhance, PCI Filters, Q-Series, SCN, SMAC, FiberLinx) TECHNICAL SUPPORT Tel: (905) 428-6068 press *3 then press 2 Toll Free: (800) 565-7488 press *3 then press 2 (USA & Canada only) Email: rfsupport@atxnetworks.com CUSTOMER SERVICE ATX Networks 1-501 Clements Road West Ajax, ON L1S 7H4 Canada Tel: (905) 428-6068 press *1 Toll Free: (800) 565-7488 press *1 (USA & Canada only) Fax: (905) 427-1964 Toll Free Fax: (866) 427-1964 (USA & Canada only) Email: support@atxnetworks.com Web: www.atxnetworks.com 5.2. Warranty Information All of ATX Networks products have a 1-year warranty that covers manufacturer s defects or failures. 5.3. Safety IMPORTANT! FOR YOUR PROTECTION, PLEASE READ THE FOLLOWING: WATER AND MOISTURE: Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through openings. POWER SOURCES: The device should be connected to a power supply only of the type described in the operating instructions or as marked on the device. GROUNDING OR POLARIZATION: Precautions should be taken so that the grounding or polarization means of the device is not defeated. POWER CORD PROTECTION: Power supply cords should be routed so that they are not likely to be pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the device. SERVICING: The user should not attempt to service the device beyond that described in the operating instructions. All other servicing should be referred to qualifi ed service personnel. FUSING: If your device is equipped with a fused receptacle, replace only with the same type fuse. Refer to replacement text on the unit for correct fuse type. SignalOn Series L-Band Splitter Module Installation & Operation Manual 5-1

ISO 9001:15 REGISTERED 2018 ATX Networks Printed in Canada Information in this document is subject to change without notice. Rev. 06/18 (ANW0848) ATX Networks 1-501 Clements Road West, Ajax, ON L1S 7H4 Canada Tel: 905.428.6068 Toll Free: 800.565.7488 support@atxnetworks.com www.atxnetworks.com