By Speed Post. PRASAR BHARATI BROADCASTING CORPORATION OF INDIA DOORDARSHAN KENDRA, JAMMU NO. : DKJ/3(3)/2008-09/-E(St) Dated: 06.04. 20 The Chief Engineer (NZ), (Kind Atten. Sh Aftab Ahmad, DE- DDM) Akashwani & Doordarshan, Jamnagar House Hutments, Shahjahan Road, New Delhi-1100. Subject:- Monthly reports of Studios of DDK, Jammu for the month of March 20. Sir Kindly find enclosed herewith the monthly report of studio of Doordarshan Kendra, Jammu for the month of March 20 for your kind information and necessary action please. Yours faithfully, Copy to : (Karan Singh ) Station Engineer The Director General, Doordarshan [ kind attention Sh.K.Subramanian, D.E. Studio (O&M,) Doordarshan Bhavan, Copernicus Marg, New Delhi for kind information. (Karan Singh ) Station Engineer 1
Studio Report KENDRA: D.D.K. JAMMU MONTH: March 20. PART (A) TRANSMISSION FIGURES S.NO TRANSMISSION DD National (Hrs) 1 LOCAL DD News (Hrs) DD Regional (Hrs.) 82.66 --- 158.76* Other Terrestrial Channel 2 NETWORK RELAY 3 TOTAL 341.36 590.03 --- --- 424. 590.03 158.76 --- 4 PROGRESSIVE TOTAL 5042.94 5330.09 1871.16 --- BREAKDOWN DETAILS a PSF 00.00 00.00 --- --- b c * Regional programme of DDK. Srinagar being relayed. 2
KENDRA: D.D.K. JAMMU MONTH: March 20. PART (B) UTILIZATION OF TECHNICAL FACILITIES 1. STUDIO ---1 STUDIO A SHIFT ALLOTED ACTUAL UTILIZATION Recording Transmission Recording Transmission % Utility Studio (b/ax100) Shift (a) Hrs Shift Hrs Shift (b) Hrs Shift Hrs 78 156 31 82.66 26 52 31 82.66 Rec.= 33.33 Tra.= 100 Remark B --- --- --- --- --- --- --- ---- ---- N.A 2. POST PRODUCTION S.NO FACILITY Date of Commissioning 1 LINER SUIT Sony FXE120P Panasonic Dec. 1996 No. of days for which the equipment is not utilized at all (0% utility) nil Total utilization during the month (Hrs) 161.34 Remark For News AG-A850 (AB ROLL/CUT TO CUT) LINER SUIT Sony FXE120P Panasonic 2 NLE Velocity June 2007 Dec. 1996 June 2005 nil 31 days 22 days 187.46 nil 22.15 For Program. For Program Testing Apple July 2006 22 days 20.45 3 GRAPHICS June 2005 30 days Nil --- 4. LAP TOP NLE ----- ---- ---- ---- 3
3. FIELD COVERAGE UNIT S.NO FACILITY 1 BETA CAMCORDER 2 DVC PRO 25 Mbps NO.OF COVERAGES Remark NEWS PROG. TOTAL --- 00 00 Not used, due to non availability of 30 minute video tapes 19 26 45 3 DVC PRO 50 Mbps Not Provided to this kendra 4 MINI DV CAMCORDERS ----- ------ ----- ----- ------ ----- One camcoder Issued to Agriculture Section for day today recordings for whole month. 4. OB/EFP VAN S.NO FACILITY NO.OF COVERAGES DURATION OF COVERAGES Live Recording Total Live Total Recording Remark 1 OB VAN Not provided to this Kendra 2 EFP VAN --- --- ---- ------ ------ DIRECTOR ( KARAN SINGH ) STATION ENGINEER 4
KENDRA: Jammu MONTH: March 20. Part (C) EQUIPMENT WORKING STUDIO Sr. No. Equipment Make Model 1 CAMERA THOMSON SONY 2 PROD. GCEL SWITCHER PSP Digital (Snell&Wilcox) B16854CA DXC-D50P 2000 SD-108 Qty Working Status 3 DVE ---- ---- ---- ----- 4 VEDIO PLAYBOX SERVER 5 CHARACTER CDAC MOVE CG GENERATOR 20 6 LOGO BAL M41A GENERATORS 7 ROUTING SWITCHERS - - 8 AUDIO SOUNDCRAFT B800 CONSOLE 9 MONITORS SONY JVC PVM 14M2E BM 1400PN 05 PANASONIC PLASMA TV 10 MICROPHONES AKG 04 SENNHEISER E835S 04 11 VTR S BETACAM PANASONIC PVW2800P SD755 12 FRAME - - - SYNCH. 13 SPG TEKTRONIX (1+1) SPG-271 14 PERIPHEALS 15 GRAPHICS MOVE CG20 16 MEASURING INSTRUMENTS 17 OTHERS (News Automations etc ) TEKTRONIX (spectrum analyzer) PHILLIPS (Oscilliscope) MS2661B (9Khz-3Ghz) OS-5100RB SHAF TECH. (News Automations) ENPS Remarks 5
2. FIELD COVERAGE UNIT S.NO. 1 2 EQUIPMENT TYPE MAKE MODEL QTY. WORKING DVC PRO PANASONIC AJ-SDC615E 04 MINI DVC JVC GY-DV-3E CAMCORDES MICROPHONES 3CCD DV BETA GUN LEPEL CHORD- LESS PANASONIC SONY SENNHEISER AKG AKG LECTRO POCKET- TYPE AG-DVC-15E KYD-29 PVV-3P MKH 416- ---- ---- 03 UCR-2 ---- 3 MONITORS SONY PVM 14M2E 4 LIGHT KITS SINGLE PERSON LINHTING KIT 5 FOR TRIPODS DVC PANASON -IC MINI DVC 6 BATTERIES/ CHARGERS BATTERY CHG FOR MINIDVC BOBBYKIT VINTEN PRO TOUCH ( LIBEC) ANTON BAU ER CHG = 4 --------- ANTON BAU ER CHG = 2 ----- H22DV ----- 04 03 03 7 OTHER CVT ELENT 3. POST PRODUCTION S.NO. FACULTY 1 LINEAR EDIT SUIT (AB ROLL/CUT TO CUT EQUIPT. DEPLOYED COMPLETE CONFIGURATION MAKE MODEL QTY. WORKING SONY PANA SONIC FXE-120P AG-A850E 2 NLE DPS VELOSITY - APPLE APPLE 3 GRAPHICS SOFT IMAGE 6
4. OB/EFP VAN EQUIPMENT EQUIPMENT S.NO. MAKE MODEL QTY. WORKING 1 CAMERA JVC KY-D29 2 PROD. SWITCHER 3 DVE GCEL WJ-5600 4 VIDEO SERVER 5 CHARACTER GENERATOR 6 LOGO GENERATOR 7 VIDEO ROUTING SWITCHER 8 AUDIO ROUTING SWITCHER 9 MARRIEDROUTING SWITCHER 10 AUDIO CONSOLE GCEL PAM- 106 11 VTR S 12 FRAME SYNCH. 13 SPG 14 SLOW MOTION SERVER 15 PERIPHERALS 16 GRAPHICS 17 OTHERS 5. MICROWAVE LINK S.NO. MAKE MODEL QTY. WORKING CONTINENTAL 1. M/W LINK VFL-60T 1+1 7
6. A.C.PLANT S.NO. TYPE MAKE MODEL QTY. 1. AIR COOLED FEDDER LLOYLD 06 WORKING THREE NOS. DEFECTIVE NEEDS REPLACEMENT ALREADY SERVED ITS USEFUL LIFE 7. POWER SUPPLY SYSTEM/UPS S.NO. EQUIPMENT/TYPE MAKE MODEL QTY. 1. UPS TATA LIEBERT DUBAS 1+1 WORKING DEFECTIVE IN CIRCUIT OUT OF CIRCUIT 8
KENDRA: DDK, Jammu MONTH: March 20. PART(E) STATEMENT OF NEW EQUIPMENT/STORES 1. NEW EQUIPMENT/SPARES RECIEVED S.N O Equipment/Type Date of Receipt Status of Deployment/ Utilization 1) 2) 3) 4) 5) 6) 7) 8) 9) DVC Pro Tapes, 33 min -100 no. DVC Pro Tapes, 66 min -100 no. DVC Pro Tapes, 126 min -50 no. DVC Pro Cylinder Unit - 2 no. DVC Pro Loading Motor Unit 2 no. Battery ( AMARON ) 42AH/12V -64 no. 15--10 In Engineering Stores Installed in UPS 2. VIDEO TAPES S.NO FORMAT DURATION QTY. IN STORES QTY. IN CIRCULATION 1) 2) 3) Beta Beta Beta 30 minutes 60 minutes 90 minutes 04(for emergency purposes) 10 2 1300 320 835 4) 5) 6) Digital -DS Digital Digital 34 minutes 64 minutes 104 minutes Nil Nil Nil 60 81 110 7) 8) 9) 10) 11) Mini DV DVC PRO DVC PRO DVC PRO DVC PRO --- 33 minutes 66 minutes 94 minutes 126 minutes 110 90 100 00 40 440 110 250 20 170 9
KENDRA: DDK, Jammu MONTH: March 20. STATEMENT OF DEFECTS AND SERVICING S.NO Equipment/Type Fault Noticed 1) A C plant, Make: Fedder Lloyds 6x3 Tons Capacity. 3 units are defective and needs replacement Period out of Commission From To Dec'06 ActionTaken/ Service Done Correspondence is going on with Zonal office / Directorate for replacement 2) 20 KVA UPS Make: Dubas Control card and Inverter cards defective March'07 Correspondence is going on with Zonal office for its repairs 10