R&S EDST300 TACAN/DME Station Tester Specifications

Similar documents
R&S EDS300 DME/Pulse Analyzer Specifications

R&S ZN-Z85 Switch Matrix Specifications

R&S ZN-Z154 Calibration Unit Specifications

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

R&S HF907DC SHF Downconverter Specifications

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S FPC1000 Spectrum Analyzer Specifications

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S ZVA110 Vector Network Analyzer Specifications

R&S SMBV-Z1 Reference Frequency Converter Specifications

R&S ZN-ZTW Torque Wrench Specifications

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S FSW-K160RE 160 MHz Real-Time Measurement Application Specifications

R&S RT-Zxx High-Bandwidth Probes Specifications

R&S FSW-K144 5G NR Measurement Application Specifications

R&S DDF200M Digital Direction Finder Specifications

R&S ZND Vector Network Analyzer Specifications

R&S GU221 Filter Control Unit Specifications

R&S DST200 RF Diagnostic Chamber Specifications

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

R&S SGU100A SGMA Upconverter Specifications

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

R&S AVG050 DVB Satellite Receiver Specifications

R&S ZNBT Vector Network Analyzer Specifications

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

R&S RT-Zxx High-Voltage and Current Probes Specifications

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications

R&S SGS100A SGMA RF Source Specifications

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

R&S FSV-K40 Phase Noise Measurement Application Specifications

R&S RT-ZVCxx Multi-Channel Power Probe Specifications

R&S RT-Zxx Standard Probes Specifications

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

R&S NRPM Over-the-Air (OTA) Power Measurement Solution Specifications

R&S TS-ISC In-System Calibration Kit On-site calibration solution for R&S CompactTSVP

EUTRA/LTE Downlink Specifications

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

R&S FPL1000 Spectrum Analyzer Specifications

Product Brochure Version R&S TSML-CW Radio Network Analyzer Powerful scanner for CW applications

R&S FSV-K8 Bluetooth /EDR Measurement Application Specifications

WLAN IEEE802.11a/b/g/j/p/n/ac/ax Measurement Application Specifications

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

R&S FS-Z60/75/90/110 Harmonic Mixers for the R&S FSP/FSU/ FSQ/FSUP/FSV

R&S TS-PMB Switch Matrix Module High-density, 90-channel, full matrix relay multiplexer module

R&S EDST300 TACAN/DME Station Tester Maintenance checks and signal-in-space analysis on TACAN and DME stations

R&S RT-Zxx Oscilloscope Adapters Specifications. Data Sheet V23.00

R&S FSV-K73 3G FDD UE (UL) Measurements incl. HSUPA Specifications

R&S Spectrum Rider FPH Handheld spectrum analyzer

R&S FPS-K18 Amplifier Measurements Specifications

EX-IQ-Box Digital Signal Interface Module Specifications

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

R&S BBL200 Broadband Amplifier Specifications

R&S FSV-K76 TD-SCDMA BS (DL) Measurements Specifications

R&S ZNL Vector Network Analyzer Specifications

R&S FSQ-K91/K91n/K91ac WLAN a/b/g/j/n/ac Application Firmware Specifications

R&S RSC Step Attenuator Where precise signal levels count

R&S TS-PSM3 High-Power Switching Module Automotive DUT supply and load switching up to 30 A

R&S FK2900M HF Antenna Tuning Unit For stationary and shipboard applications

R&S MDS-21 Absorbing Clamp Measurement of disturbance power and screening effectiveness on cables

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

R&S TS-PSM5 High-Power Switching Module Automotive DUT supply and load switching up to 50 A

EUTRA/LTE Measurement Application Specifications

R&S TS-PFG Function Generator Module Dual-channel arbitrary waveform generator with isolated outputs

DVG MPEG-2 Measurement Generator

R&S M3TR R&S VT3050C 50 W VHF/UHF Compact Power Amplifier Specifications

R&S NRP Power Sensor Family Specifications

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

R&S ELEKTRA EMI Test Software Easy to use software for measuring electromagnetic disturbances

Dynamic re-referencing Microvolt-level measurements with the R&S RTO oscilloscopes

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

R&S TS-PIO4 Digital Functional Test Module 32-channel programmable digital I/O module

All doors in flight. Terrestrial air navigation test and measurement solutions.

R&S SFD DOCSIS Signal Generator Signal generator for DOCSIS 3.1 downstream and upstream

R&S VSE Vector Signal Explorer Base Software Specifications

R&S FPC-Z10 Teaching Kit Getting Started

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

R&S FSMR Measuring Receiver Specifications

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas

RS Pro SPECTRUM ANALYZER SSA3000X SERIES

R&S TS6300 ILS Test System Mobile automatic test solution for ILS ground measurements

ESU EMI Test Receiver Specifications

SMS3000X Series Spectrum Analyzer

R&S GX460 Digital Wideband Storage Device Recording and replaying device for I/Q data with up to 40 MHz bandwidth

R&S SMF100A Microwave Signal Generator Specifications

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

Scope of the art Scope Rider Handheld digital oscilloscope

Meeting your needs R&S RTO2000 Digital Oscilloscope

R&S CONTEST ITS Test cases and applications

Test Device Containment Module (TCM) Optimal conditions for reliable results

Transcription:

R&S EDST300 TACAN/DME Station Tester Specifications year Data Sheet Version 01.01

CONTENTS Definitions... 3 Specifications... 4 Standards... 4 Frequency... 4 TX Power Measurement (R&S EDST300 analyzer)... 4 TACAN modulation analysis (R&S EDST-K1 option)... 5 Pulse shape analysis (time domain, R&S EDST-K2 option)... 6 Transponder delay/distance measurement... 6 RX measurement (R&S EDST300 generator, R&S EDST-B2 option)... 7 Inputs and outputs (front)... 7 Inputs and outputs (rear)... 7 DME test antenna (R&S EDST-Z1 option)... 8 General data... 9 Ordering information... 10 2 Rohde & Schwarz R&S EDST300 TACAN/DME Station Tester

Definitions General Product data applies under the following conditions: Three hours storage at ambient temperature followed by 30 minutes warm-up operation Specified environmental conditions met Recommended calibration interval adhered to All internal automatic adjustments performed, if applicable Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <,, >,, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift and aging, if applicable. Non-traceable specifications with limits (n. trc.) Represent product performance that is specified and tested as described under Specifications with limits above. However, product performance in this case cannot be warranted due to the lack of measuring equipment traceable to national metrology standards. In this case, measurements are referenced to standards used in the Rohde & Schwarz laboratories. Specifications without limits Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design. Typical data (typ.) Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the mean value. Nominal values (nom.) Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to typical data, a statistical evaluation does not take place and the parameter is not tested during production. Measured values (meas.) Characterize expected product performance by means of measurement results gained from individual samples. Uncertainties Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account environmental conditions, aging, wear and tear. Device settings and GUI parameters are indicated as follows: parameter: value. Non-traceable specifications with limits, typical data as well as nominal and measured values are not warranted by Rohde & Schwarz. In line with the 3GPP/3GPP2 standard, chip rates are specified in Mcps (million chips per second), whereas bit rates and symbol rates are specified in Mbps (million bits per second), kbps (thousand bits per second) or ksps (thousand symbols per second), and sample rates are specified in Msample/s (million samples per second). Mcps, kbps, ksps and Msample/s are not SI units. Rohde & Schwarz R&S EDST300 TACAN/DME Station Tester 3

Specifications Standards Military standards STANAG 5034, MIL-STD-291C Civilian standards ICAO Annex 10, ICAO Doc 8071 Frequency Frequency range Frequency resolution 960 MHz to 1215 MHz 0.1 MHz Reference frequency, internal Accuracy Aging per year Temperature drift +5 C to +40 C 1 ppm Achievable internal calibration accuracy 1 ppm ±(time since last adjustment aging rate + temperature drift + calibration accuracy) 1 ppm RF Frequency measurement Offset from nominal channel frequency Resolution Accuracy 60 dbm to +30 dbm, measurement time 200 ms 0.1 khz 1 ppm (nom.) TX Power Measurement (R&S EDST300 analyzer) Max. input level DC voltage RF pulse power +25 V DC +36 dbm Power measurement Units Display range Measurement range (peak detector) Measurement range (average detector) Level resolution Peak level deviation autorange mode RF input 1 RF input 2 autorange mode RF input 1 RF input 2 standard TACAN signal in line with MIL-STD-291C or standard DME signal in line with ICAO Annex 10, RF input 1, level range 15 dbm to 25 dbm, 95 % confidence level, +20 C to +30 C dbm and W 120 dbm to +30 dbm 80 dbm to +30 dbm 100 dbm to +10 dbm 95 dbm to +30 dbm 110 dbm to +10 dbm 0.01 db 0.3 db Additional linearity error 10 dbm to 70 dbm, normal mode < 0.5 db Internally generated spurious signals RF input 2, low noise mode < 95 dbm Total measurement uncertainty Peak level deviation standard TACAN signal in line with MIL-STD-291C or standard DME signal in line with ICAO Annex 10, RF input 1 or 2, level range 80 dbm to +30 dbm, 95 % confidence level, +20 C to +30 C < 1 db (nom.) Intermodulation 1 db compression point RF input 1, low distortion mode +33 dbm (nom.) RF input 2, low distortion mode +10 dbm (nom.) Third-order intercept point (TOI) RF input 1, low distortion mode +50 dbm (typ.) RF input 2, normal mode +20 dbm (typ.) 4 Rohde & Schwarz R&S EDST300 TACAN/DME Station Tester

TACAN modulation analysis (R&S EDST-K1 option) Input level range RF input 1 80 dbm to +30 dbm RF input 2 92 dbm to +10 dbm Modulation depth 5 % to 50 % Resolution 0.01 % Deviation 15 Hz/135 Hz ± 5 % 1 < 0.5 % AF Resolution 0.01 Hz Deviation 15 Hz/135 Hz ± 5 % 1 < 0.1 Hz Bearing Resolution 0.01 Deviation 70 dbm to +30 dbm, RF input 1, < 0.2 standard TACAN signal in line with STANAG 5034, modulation depth of 15 Hz and 135 Hz signals = 21 %, measurement time 1 s Additional bearing error 70 dbm to +30 dbm, RF input 1, < 0.1 standard TACAN signal in line with STANAG 5034, modulation depth of 15 Hz and 135 Hz signals = 7 % to 30 %, measurement time 1 s Deviation 90 dbm to 70 dbm, RF input 2, < 0.5 standard TACAN signal in line with STANAG 5034, modulation depth of 15 Hz and 135 Hz signals = 21 %, measurement time 1 s Bearing acquisition time < 3 s Phase angle 15 Hz/135 Hz Resolution 0.01 Deviation standard TACAN signal in line with < 0.5 (nom.) STANAG 5034, modulation depth of 15 Hz and 135 Hz signals = 20 %, measurement time 500 ms MRB pulse count range X 8 to 14 double pulses/mrb range Y 8 to 15 single pulses/mrb MRB pulse spacing range X/Y 28 µs to 32 µs ARB pulse count range X 4 to 8 double pulses/arb range Y 8 to 15 single pulses/arb ARB pulse spacing range X 22 µs to 26 µs range Y 13 µs to 17 µs Pulse spacing Resolution 0.001 µs Deviation < 0.05 µs Pulse repetition rate 1/s to 8000/s Identifier analysis ID code morse code 2 to 4 characters ID pulse repetition rate 1325 Hz to 1375 Hz Equalizer pulse delay range 80 µs to 120 µs (nom.) Uncertainty of ID timing measurements < 2 ms (nom.) Dot length range 80 ms to 170 ms. (nom.) Dash length range 240 ms to 510 ms (nom.) ID period range 10 s to 50 s (nom.) 1 Max. frequency drift of modulation signal. Rohde & Schwarz R&S EDST300 TACAN/DME Station Tester 5

Pulse shape analysis (time domain, R&S EDST-K2 option) Resolution bandwidth selectable 0.5 MHz, 10 MHz (nom.) Display range displayed noise floor up to +30 dbm Time/division 0.5/1/2/5/10/20/50 µs, selectable Reference level 70 dbm to +30 dbm Trace functions clear/write, average, max. hold Trigger Trigger source level/external/dme pulse/interrogator MRB/ARB trigger source Trigger delay 500 µs to +8000 µs Pulse shape analysis pulse 1, pulse 2 rise time, duration, decay time Resolution 0.01 µs Deviation < 0.05 µs (nom.) Pulse spacing Resolution 0.001 µs Deviation < 0.05 µs Additional measurement values peak variation Transponder delay/distance measurement Modes search, track, memory Input level range RF input 1 80 dbm to +30 dbm (nom.) RF input 2 100 dbm to +10 dbm (nom.) Delay/distance measurement Delay/distance range 20 ns to 4 ms (nom.) 0 NM to 400 NM (nom.) Resolution 0.01 µs, 0.001 km, 0.001 NM Deviation 70 dbm to +30 dbm, RF input 1 measurement time 200 ms, PRR 100/s, 95 % confidence level 50 ns, 7,5 m (nom.), 0.005 NM (nom.) 80 dbm to +10 dbm, RF input 2 measurement time 200 ms, PRR 100/s, 95 % confidence level 90 dbm to 80 dbm, RF input 2 reply efficiency > 70 %, measurement time 500 ms 95 % confidence level 95 dbm to 90 dbm, RF input 2 measurement time 500 ms 95 % confidence level Lock-on time reply efficiency > 70 %, search mode pulse rate 150/s 50 ns, 7,5 m (nom.), 0.005 NM (nom.) 500 ns, 75 m (nom.), 0.05 NM (nom.) 500 ns, (nom.) 75 m (nom.), 0.05 NM (nom.) < 3 s Reply efficiency range 0 to 100 % 6 Rohde & Schwarz R&S EDST300 TACAN/DME Station Tester

RX measurement (R&S EDST300 generator, R&S EDST-B2 option) Frequency range 960 MHz to 1215 MHz Frequency step size 100 khz Channels 1X to 126X, 1Y to 126Y Output power 80 dbm to +30 dbm Output power step size 0.1 db Level uncertainty +20 C to +30 C < 1 db, 0.5 db (typ.) Interrogation loading/reply capability test Pulse rate default mode 5 Hz to 6000 Hz in 1 Hz steps ICAO compliant mode, search/track 5 Hz to 150 Hz / 5 Hz to 30 Hz in 1 Hz steps Decoder rejection test Pulse spacing X mode 12 µs (default) Y mode 36 µs (default) Setting range X/Y mode 8 µs to 42 µs in 0.1 µs steps Deviation 0.05 µs Pulse duration 50 % points, default 3.5 µs ± 0.2 µs setting range, 50 % points 1 µs to 4.5 µs in 0.1 µs steps Pulse rise time 10 % to 90 % 2.0 µs ± 0.25 µs Pulse decay time 90 % to 10 % 2.5 µs ± 0.3 µs Peak variation coded pulse pair on 50 Ω load < 0.5 db Pulse Counter Frequency range 2 Hz to 1 MHz Resolution 1 Hz Uncertainty < 1 Hz (nom.) Time resolution 50 ns Inputs and outputs (front) RF 1 IN/OUT RF input/output N connector, 50 Ω VSWR < 2.0 RF 2 IN RF input N connector, 50 Ω AF OUT headphone 3.5 mm female connector Antenna supply 12 V ± 0.5 V (nom.) USB USB 2.0 double A connector USB stick for data logging and software update Inputs and outputs (rear) Analog OUT BNC 50 Ω (nom.) Analog IN BNC 50 Ω (nom.) Trigger OUT BNC 20 Ω (nom.) Counter/Trigger IN BNC 100 kω, 3 V to 30 V (nom.) Suppress IN/OUT BNC, input/ output for suppressor line 30 kω in (nom.) 0.5 kω out (nom.) Ref 10 MHz IN/OUT BNC 50 Ω (nom.) LAN LAN interface RJ-45, 100BaseT RS232 RS232, 9-pin D-Sub connector USB USB 2.0 double A connector USB stick for data logging and software update External monitor DVI-D Rohde & Schwarz R&S EDST300 TACAN/DME Station Tester 7

DME test antenna (R&S EDST-Z1 option) Frequency range 960 MHz to 1215 MHz Polarisation vertical Impedance 50 Ω (nom.) Gain 11 dbi (nom.) Front-to back ratio > 26 db (nom.) Pulse power max. 1000 W VSWR 1:2 (typ.) Connector N female Dimensions (L W H) approx. 400 mm 450 mm 350 mm Weight 1.6 kg Temperature range 30 C to +50 C Mounting fixed installation clamps included for mast mounting portable use 5/8" screw for prism pole or tripod 8 Rohde & Schwarz R&S EDST300 TACAN/DME Station Tester

General data Environmental conditions Temperature operating temperature range +5 C to +40 C permissible temperature range 0 C to +50 C storage temperature range 25 C to +70 C Damp heat +25 C/+40 C, 95 % rel. humidity, cyclic, in line with EN 60068-2-30 Altitude operating 4600 m (without external power supply) transport 10000 m (without external power supply) Mechanical resistance Vibration sinusoidal 5 Hz to 55 Hz, 0.15 mm amplitude const., 55 Hz to 150 Hz, 0.5 g const., in line with EN 60068-2-6 random 10 Hz to 300 Hz, acceleration 1.2 g RMS, in line with EN 60068-2-64 Shock 40 g shock spectrum, in line with MIL-STD-810E, method 516.4, procedure I Power supply Rated voltage base unit 20 V to 28 V DC base unit with internal battery 24 V (±5 %) external power supply 100 V to 240 V AC (±10 %) Rated frequency external power supply 50 Hz to 60 Hz (±5 %) Rated current 5.0 A DC (max.) external power supply 1.2 A to 0.5 A AC Battery R&S EDST-B3 option Lithium Ion Operating time new, fully charged battery > 2.5 h Charging time instrument in standby mode 3.5 h (nom.) instrument switched on 6.5 h (nom.) Product conformity Electromagnetic compatibility Electrical safety EU: in line with EMC Directive 2004/108/EC EU: in line with Low Voltage Directive 2006/95/EC applied harmonized standards: IEC/EN 61326-1, IEC/EN 61326-2-1, EN 55022 (class B) in line with IEC 61010-1, EN 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-04 Calibration interval recommended for highest accuracy 12 months for general test and measurement 24 months applications Dimensions W H D 342 mm 157 mm 266 mm (13.46 in 6.18 in 10.47 in) (3/4 19", 3 HU) Weight with battery, external power supply not 7.2 kg (15.9 lb) included Display 6.5" TFT color display Antireflection interference optical coated glass Resolution 800 600 pixel Pixel failure rate < 1.1 10 5 Rohde & Schwarz R&S EDST300 TACAN/DME Station Tester 9

Ordering information Designation Type Order No. Base unit TACAN/DME Station Tester R&S EDST300 5202.9009.02 Hardware options Interrogator R&S EDST-B2 5202.9509.02 Internal Battery R&S EDST-B3 5202.7187.02 Software options TACAN Analysis R&S EDST-K1 5202.9515.02 Pulse Shape Analysis R&S EDST-K2 5202.9521.02 Accessories Documentation of Calibration Values R&S DCV-2 0240.2193.10 DME Test Antenna R&S EDST-Z1 5202.9538.02 Verification Test R&S EDST-Z10 5202.9544.02 Rugged Transport Case R&S EDS-Z2 5202.8202.02 Service options Extended Warranty, one year R&S WE1 Please contact your local Extended Warranty, two years R&S WE2 Rohde & Schwarz sales office. Extended Warranty with Calibration Coverage, one year R&S CW1 Extended Warranty with Calibration Coverage, two years R&S CW2 Extended warranty with a term of one to two years (WE1 to WE2) Repairs carried out during the contract term are free of charge 2. Necessary calibration and adjustments carried out during repairs are also covered. Simply contact the forwarding agent we name; your product will be picked up free of charge and returned to you in top condition a couple of days later. Extended warranty with calibration (CW1 to CW2) Enhance your extended warranty by adding calibration coverage at a package price. This package ensures that your Rohde & Schwarz product is regularly calibrated, inspected and maintained during the term of the contract. It includes all repairs 2 and calibration at the recommended intervals as well as any calibration carried out during repairs or option upgrades. For product brochure, see PD 3607.3645.12 and www.rohde-schwarz.com 2 Excluding defects caused by incorrect operation or handling and force majeure. Wear-and-tear parts are not included. 10 Rohde & Schwarz R&S EDST300 TACAN/DME Station Tester

Rohde & Schwarz R&S EDST300 TACAN/DME Station Tester 11

Service that adds value Worldwide Local and personalized Customized and flexible Uncompromising quality Long-term dependability Rohde & Schwarz The Rohde & Schwarz electronics group offers innovative solutions in the following business fields: test and measurement, broadcast and media, secure communications, cybersecurity, monitoring and network testing. Founded more than 80 years ago, the independent company which is headquartered in Munich, Germany, has an extensive sales and service network with locations in more than 70 countries. Certified Quality Management ISO 9001 Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com Rohde & Schwarz training www.training.rohde-schwarz.com Regional contact Europe, Africa, Middle East +49 89 4129 12345 customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia Pacific +65 65 13 04 88 customersupport.asia@rohde-schwarz.com China +86 800 810 82 28 +86 400 650 58 96 customersupport.china@rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners PD 3607.3645.22 Version 01.01 April 2018 (as/ja) R&S EDST300 TACAN/DME Station Tester Data without tolerance limits is not binding Subject to change 2016-2018 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany 3607.3645.22 01.01 PDP 1 en 3607364522