Measurements of musical instruments with surrounding spherical arrays

Similar documents
RECORDING AND REPRODUCING CONCERT HALL ACOUSTICS FOR SUBJECTIVE EVALUATION

Concert halls conveyors of musical expressions

Why do some concert halls render music more expressive and impressive than others?

The influence of Room Acoustic Aspects on the Noise Exposure of Symphonic Orchestra Musicians

The interaction between room and musical instruments studied by multi-channel auralization

Room acoustics computer modelling: Study of the effect of source directivity on auralizations

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

AURALISATION OF CONCERT HALLS USING MULTI- SOURCE REPRESENTATION OF A SYMPHONY ORCHESTRA

Methods to measure stage acoustic parameters: overview and future research

Development, Evaluation, and Validation of a High- Resolution Directivity Measurement System for Played Musical Instruments

DELAWARE MUSIC EDUCATORS ASSOCIATION ALL-STATE ENSEMBLES GENERAL GUIDELINES

Binaural sound exposure by the direct sound of the own musical instrument Wenmaekers, R.H.C.; Hak, C.C.J.M.; de Vos, H.P.J.C.

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007

Calibration of auralisation presentations through loudspeakers

Perception of bass with some musical instruments in concert halls

JOURNAL OF BUILDING ACOUSTICS. Volume 20 Number

Multichannel source directivity recording in an anechoic chamber and in a studio

Proceedings of Meetings on Acoustics

New recording techniques for solo double bass

Room Acoustics. Hearing is Believing? Measuring is Knowing? / Department of the Built Environment - Unit BPS PAGE 0

Articulation Guide. Berlin Orchestra Inspire.

Huntsville Youth Orchestra Auditions. Philharmonia VIOLIN

Guitar and Rock/Blues Vocalists

TABLE OF CONTENTS CHAPTER 1 PREREQUISITES FOR WRITING AN ARRANGEMENT... 1

I n spite of many attempts to surpass

The Elements of Music

The Elements of Music

The tempo MUSICAL APPRECIATIONS MUSICAL APPRECIATION SHEET 1. slow. Can you hear which is which? Write a tick ( ) in the PIECES OF MUSIC

Huntsville Youth Orchestra Auditions. Sinfonia VIOLIN

about Orchestra Linus Metzler L i m e n e t L i n u s M e t z l e r W a t t s t r a s s e F r e i d o r f

Spectral Sounds Summary

White Paper JBL s LSR Principle, RMC (Room Mode Correction) and the Monitoring Environment by John Eargle. Introduction and Background:

Music Study Guide. Moore Public Schools. Definitions of Musical Terms

The Elements of Music. A. Gabriele

2014 Music Style and Composition GA 3: Aural and written examination

USING MICROPHONE ARRAYS TO RECONSTRUCT MOVING SOUND SOURCES FOR AURALIZATION

The acoustics of the Concert Hall and the Chinese Theatre in the Beijing National Grand Theatre of China

GROSSE POINTE SOUTH HIGH SCHOOL BAND AUDITIONS

Prelude. Name Class School

Norman Public Schools MUSIC ASSESSMENT GUIDE FOR GRADE 8

Flint School of Performing Arts Ensemble Audition Requirements

Greater Cleveland Instrumental Solo and Ensemble Contest Association. RULES AND REGULATIONS (revised September 2016)

Proceedings of Meetings on Acoustics

Workshop Friday, June 27th 1:00 PM

Simple Harmonic Motion: What is a Sound Spectrum?

Binaural dynamic responsiveness in concert halls

HIGH SCHOOL BAND, ORCHESTRA, AND PERCUSSION ENSEMBLE Audition Requirements

Quarterly Progress and Status Report. An attempt to predict the masking effect of vowel spectra

Year 7 revision booklet 2017

LBSO Listening Activities. Fanfare for the Common Man Suggested time minutes

WMEA WIAA State Solo and Ensemble Contest 2018

Trends in preference, programming and design of concert halls for symphonic music

OBJECT-AUDIO CAPTURE SYSTEM FOR SPORTS BROADCAST

FLOW INDUCED NOISE REDUCTION TECHNIQUES FOR MICROPHONES IN LOW SPEED WIND TUNNELS

The Story of the Woodwind Family. STUDY GUIDE Provided by jewel winds

ELECTRO-ACOUSTIC SYSTEMS FOR THE NEW OPERA HOUSE IN OSLO. Alf Berntson. Artifon AB Östra Hamngatan 52, Göteborg, Sweden

A typical example: front left subwoofer only. Four subwoofers with Sound Field Management. A Direct Comparison

CONCERT HALL STAGE ACOUSTICS FROM THE PERSP- ECTIVE OF THE PERFORMERS AND PHYSICAL REALITY

Sound design strategy for enhancing subjective preference of EV interior sound

Requirements for the aptitude tests at the Folkwang University of the Arts

THE EFFECT OF PERFORMANCE STAGES ON SUBWOOFER POLAR AND FREQUENCY RESPONSES

Acoustics and the Performance of Music

Articulation Guide. TIME macro.

WMEA WIAA State Solo and Ensemble Contest 2012

LAMONT SCHOOL OF MUSIC

WMEA WIAA State Solo and Ensemble Contest 2011

Music for the Hearing Care Professional Published on Sunday, 14 March :24

Audition Guidelines & Repertoire Lists Season

MUSIC (MUSC) Bucknell University 1

Guide to Band Instruments

Technical Guide. Installed Sound. Loudspeaker Solutions for Worship Spaces. TA-4 Version 1.2 April, Why loudspeakers at all?

Welcome to the West Babylon Musical Instrument Program!

about half the spacing of its modern counterpart when played in their normal ranges? 6)

Physics HomeWork 4 Spring 2015

about half the spacing of its modern counterpart when played in their normal ranges? 6)

hhh MUSIC OPPORTUNITIES BEGIN IN GRADE 3

ROOM LOW-FREQUENCY RESPONSE ESTIMATION USING MICROPHONE AVERAGING

LIVE SOUND SUBWOOFER DR. ADAM J. HILL COLLEGE OF ENGINEERING & TECHNOLOGY, UNIVERSITY OF DERBY, UK GAND CONCERT SOUND, CHICAGO, USA 20 OCTOBER 2017

HIGH SCHOOL BAND, ORCHESTRA, & PERCUSSION ENSEMBLE

Binaural Measurement, Analysis and Playback

FC Cincinnati Stadium Environmental Noise Model

CHAPTER 14 INSTRUMENTS

Articulation Guide. Berlin Orchestra Inspire 2.

Loudness and Sharpness Calculation

Audition Information

Generating the Noise Field for Ambient Noise Rejection Tests Application Note

What do we hope to measure?

INTERMEDIATE BAND, ORCHESTRA, AND PERCUSSION ENSEMBLE Audition Requirements

Measurement of overtone frequencies of a toy piano and perception of its pitch

CUSSOU504A. Microphones. Week Two

Mathematics in Contemporary Society - Chapter 11 (Spring 2018)

It is the responsibility of the Region/Area Band Chair to ensure that sites chosen for auditions are ADA compliant.

A few white papers on various. Digital Signal Processing algorithms. used in the DAC501 / DAC502 units

Physics Homework 4 Fall 2015

BASIC VOCABULARY. Bow: arco. Slide brass instruments: instrumentos de viento metal de varas. To bow: frotar.

Instruments of the orchestra

PROGRAMMING FOR THE YOUTH AND COMMUNITY ORCHESTRA: BEETHOVEN AND SCHUBERT AS MODELS FOR SELECTION A CREATIVE PROJECT SUBMITTED TO THE GRADUATE SCHOOL

The String Family. Bowed Strings. Plucked Strings. Musical Instruments More About Music

MUSIC (MUAP, MUEN, MUSI)

Danville Public Schools Music Curriculum Preschool & Kindergarten

Transcription:

Measurements of musical instruments with surrounding spherical arrays G. K. Behler, M. Pollow and M. Vorländer RWTH Aachen University, Institute of Technical Acoustics, Templergraben 55, 52056 Aachen, Germany gkb@akustik.rwth-aachen.de 761

The directivities of natural sound sources such as musical instruments are often neglected in auralization, both when working with measured or simulated acoustical environments. This is due to the complex nature of both the radiation of musical instruments and the post-processing involved in this task. However, as the directivity patterns constitute an audible part of the tonal characteristic of a musical instrument in a room, it is advisable to take their directivities into account. To conduct the measurements, a large surrounding spherical microphone array was constructed that allows to fully encompass the musician in an anechoic chamber. Hereby great care has to be taken in the design process of the recording device in order to obtain a broad-band omnidirectional sensitivity of the used microphones. The acquired multi-channel audio data can be then used to analyze the directivities of the recorded instrument. 1 Introduction In auralization of acoustic scenery consisting of source, transfer path and receiver, the directivity patterns of the sound sources are often neglected and thus implicitly assumed to be of omnidirectional type. The international standard for room acoustical measurements ISO 3382-1 even demands omnidirectional sources for the use in such measurements in order to make different measurements comparable. New studies, however, show that the direcitvity of sound source matters more than commonly expected [1]. Even in the late part of the impulse responses the influence of the radiation pattern can still be noticed, even if the sound field is already highly diffuse at that time [2]. Musical instruments owe a part of their character to their tonal color, which varies for different directions [3]. Including these specific spectral differences for the sound radiation in different directions, the auralization is expected to be enhanced in terms of natural perception. Any measured or simulated room impulse responses for omnidirectional sound sources are lacking these varying directional dependent tonal color and cannot be modified afterwards to include the described effect. In order to take the directivities of musical instruments into account, the radiation patterns need to be measured and prepared for the use in room acoustical measurement and simulations. For the analysis of these instrument specific properties, a large surrounding spherical microphone array was constructed to record the sound radiation of a source in many directions simultaneously. This paper deals with questions regarding hardware setup, full calibration of the measurement chain and issues as how to obtain clean and correct data of the emitted sound. These data can be used later on for studies to analyze data such as the emitted sound power of instruments or the radiated directivity patterns. 3 Surrounding spherical microphone array In order to capture the radiation of naturally excited musical instruments, all directions have to be measured simultaneously, due to the lack of repeatability. This motivates the construction of a lightweight and transportable spherical microphone array. The chosen geometry of the array is a truncated icosahedron, distributing 32 microphones regularly on the surface of a sphere with a diameter of 4.20 m. In Figure 1 a sketch of the geometry is depicted. The array consists of 90 flexible fiber glass sticks that can be connected to hold the microphones on a spherical surface. With some attached strings the whole array forms a light but very stable construction. The complete setup can be placed in an anechoic chamber in order to avoid any reflections from the walls and the ground floor, as depicted in Figure 2. If the height of the anechoic chamber is not sufficient for the full array, a reduced version can be used by omitting the highest and/or the lowest microphone of the array. Each of the two microphones save about 40 cm in the required height. In the center of the array an adjustable chair is placed that can be used to place the musician approximately into the geometrical center. The stand can be extended in height to quickly to set the height of the musician in order to move them as close as possible to the geometric center of the array. However, for large instruments as the contrabass the placement is too low; this has to be accounted for in postprocessing. [12] 2 Previous work The first approach to collect data for a directivity database goes back to the 1970s with Jürgen Meyer publishing the measured radiation of various instruments in averaged octave bands [4]. More recently Otondo and Rindel measured the directivity with a set of microphones distributed around the musician, using 13 microphones distributed on the median plane and on the horizontal plane [5]. In 2010 Pätynen and Lokki [6] used a slightly denser distribution of 22 microphones and recorded pieces of music. A spherical microphone array with 64 channels was constructed in Graz, Austria, designed for optimal spherical harmonic processing [7]. Figure 1: Sketch of the geometry of the spherical microphone array with a diameter of 4.20 m 762

microphones revealed that this is caused by the reflexion at the fiberglass sticks attached to the microphone housing. Whereas any regular frequency deviation from a flat frequency spectrum can easily be compensated (or can even be ignored for directivity measurements as it occurs on all microphones), this symmetry yields a sensitivity which is highly dependent on the angle of incidence. This was further verified using a boundary element method simulation of the housing as depicted in Figure 4, confirming the strong influence of the direction of sound incidence. This effect cannot be compensated for later on, an aligned sound source can thus help to minimize such deviations between the effective microphone sensitivities encountered for a given direction of incoming sound. [8] Figure 2: Mounted surrounding spherical microphone array with 32 microphones 4 Calibration of the microphones The correct calibration of the microphones is crucial for precise measurements. This includes both the sensitivities of the capsules as well as the mounting situation, e.g. the housing of the microphones. The captured sound is supposed to consist purely from direct sound radiation without any reflections or diffraction of objects in the vicinity that do not belong to the musician or the musical instrument. An acoustical transparent behavior of the array is thus desirable. 4.1 Housing of the microphones The housing of the microphones is very important as any additional sound path arriving at the microphone (e.g. due to reflections on the housing) can cause highly frequency dependent comb-filter effects. As the array is highly symmetric several small reflections can sum up to arrive at the same time instance and cause significant interference, so great care has to be taken to avoid any reflection on the mechanical structure. Figure 3: Close-up of the microphone array without additional absorbers, electret capsule at the narrow end of the conical shape, preamplifier in the rear end Even the thin structure as shown in Figure 3 is sufficient to cause on-axis comb filter effects starting from frequencies as low as 2 khz. Sensitivity measurements of the Modulus in db 10 5 0 5 0 [db re 1] 20 [db re 1] 40 [db re 1] 10 200 400 1k 2k 4k 6k 10k 20k Frequency in Hz Figure 4: Boundary-element simulation to quantify the influence of the microphone housing without attachment for different angles of incidence, cf. [8] In order to improve the array in terms of constant sensitivity over the angle of sound incidence several attachments for the microphones were tested: a solid drop shaped material (as used in a similar project [9]) and several types of acoustical foam in different shapes. Finally, a dense acoustic foam in sphere-like shape was chosen due to its smooth frequency response over a range of sensible angles of incidence. 4.2 Calibration of the electret capsule To measure the individual sensitivities of the used electret microphones, each capsule was mounted in a rigid wall in the floor of an hemi-anechoic chamber, so that the front face of the microphone is aligned with the rigid wall. A reproducible sound pressure was applied and the resulting spectrum was compared with a high quality G.R.A.S. quarter inch pressure microphone (type 40BP) with a flat frequency response. This measurement procedure allows to derive the microphone sensitivities as functions of frequency. In general the obtained sensitivity spectra show very similar characteristics but differ in their absolute levels. An equalization of the sensitivities as measured at a single frequency is thus sufficient for high quality electret microphones such as the used Sennheiser KE 4-211-2. However, the broad band sensitivities were used as measured for the evaluation of this data. The result is a frequency dependent microphone sensitivity that accounts for the sensitivity of the individual electret capsule as well as for the influence of its housing. 5 Recording setup The recording setup consists of a standard workstation PC or Laptop running a multitrack recording software of 763

choice. Each of the microphones is connected to a preamplifier and from there to the sound card which is connected with the computer. Studio quality microphones can be added to obtain a track of higher quality for auralization of the recorded data. A calibration of the setup including the studio microphones can be performed to allow correct sound tracks in terms of referenced sound pressure level at the distance of the array microphones. Alternatively, these microphones can also be placed at closer ranges than the array microphones to obtain a nearfield recording of the emitted sound. The additional high quality microphones are suitable for auralization, as the array microphones have a rather high selfnoise level (approx. 35 dba) rendering them insufficiently noisy when used for recordings at a distance of 2 m from the source. tones without any vibrato or tremolo and to keep in a steady position to be able to compare the directivities of sequentially played tones. 5.1 Artificial reverb via headphones Musicians usual find it strange to perform in the acoustical environment of an anechoic chamber. To avoid disturbances the recording of their sound radiation was looped back through a reverberator and presented to the musician by headphones. In-ear headsets or closed headphones are suitable in order not to contribute to the measured radiation pattern during the recording. 5.2 Recorded audio material Contrarily to some other studies, each instruments was recorded with clean single tones, encompassing all possible pitches and (depending on the instrument) also the playing style. All these tones were recorded in two different levels, pianissimo (as soft as possible) and fortissimo (as loud as possible). This choices were motivated due to the focus of TU Berlin to measure the sound power of both historical and modern symphonic instruments. [10, 11] With the described setup it is possible to record the musician simultaneously with fully calibrated microphones. Depending on the desired results, it can make sense to record individual tones of chromatic scales or a full piece of music [12]. Woodwinds (Bassoon, Contrabassoon, Oboe, English horn, Clarinet, Bass clarinet, Alto saxophone, Tenor saxophone) Brass instruments (Trumpet, Tenor trombone, Bass trombone, Tenor saxophone, Tuba, French horn) Percussion (Timpani) Singer (Soprano, Gregorian choir) String instruments (Viola, Violin, Cello, Doubleaction pedal harp, Contrabass, Classical guitar) Figure 5: Exemplary setup of the recording hardware To measure the directivity of a musical instrument, the musician is placed on an elevated seat as centered as possible within the array. This positioning can be problematic due to practical limitations in the setting as mounted in the full anechoic chamber. Large instruments, such as the contrabass, the timpani or the harp, had to be measured out of center with the help of additional structures to keep musician and instrument in a position in the array. Perspective photos help to track down the location and to compensate for the de-centered position. For each instruments the electrical levels are adjusted and re-calibrated if necessary to be suitable for the emitted levels of the measured instrument. After starting the recording, the musicians can be instructed to play either chromatic scales (to get the full range of possible tones) or a piece of music (to obtain a dynamic recording to be used as is for auralization). All the musicians were asked to play clean and steady Flutes (Western concert Boehm flute) Except for the Gregorian choir (which was recorded at the University of Madrid) the recordings were performed in a joint project at anechoic chamber at the Audio Communication Group, TU Berlin. 6 Conclusion A high quality set of data was obtained, using a surrounding microphone array with 32 channels. Full calibration allows the determination of the actual sound pressure values at the microphone positions. These data can be used to gain knowledge about the distinct characteristics of musical instruments, like radiated sound power and directivity. The directivities obtained from this study can be used to measure or simulate the room impulse response with respect to a specific directivity. A method for the measurement can be found in [13], algorithms for the use in simulation software can be found in [14]. 764

The results are used in the virtual reality system at RWTH Aachen University, where directivity patterns are usually applied in third octave bands to allow for computation in real time. Furthermore, only the absolute value is needed, as the simulated data is based on a stochastic model. The data can also be used to gain knowledge about the distinct characteristics of musical instruments, like radiated sound power and directivity. Acknowledgments The authors thank the Audio Communication Group at TU Berlin and the Research Group in Architectural Acoustics at Universidad Politécnica de Madrid for performing the directivity recordings in cooperate projects. Furthermore we thank everyone involved in the recording sessions. References [1] M. C. Vigeant, L. M. Wang, J. H. Rindel, Investigations of multi-channel auralization technique for solo instruments and orchestra, 19th International Congress on Acoustics, Madrid (2007) [2] T. Knüttel, I. Witew, and M. Vorländer, Einfluss der Quellenrichtcharakteristik auf die Raumimpulsantwort Fortschritte der Akustik: 37. Deutsche Jahrestagung für Akustik (2011) [3] G. Weinreich, Directional tone color, The Journal of the Acoustical Society of America, vol. 101, p. 2338 (1997) [4] J. Meyer, U. Hansen, Acoustics and the performance of music: manual for acousticians, audio engineers, musicians, architects and musical instruments makers, Springer (2009) [5] F. Otondo, J. H. Rindel, The influence of the directivity of musical instruments in a room, Acta Acustica united with Acustica, vol. 90, p. 1178 1184 (2004) [6] J. Pätynen, T. Lokki, Directivities of Symphony Orchestra Instruments, Acta Acustica united with Acustica, vol. 96, p. 138 167 (2010) [7] F. Hohl, Kugelmikrofonarray zur Abstrahlungsvermessung von Musikinstrumenten, Master thesis, IEM, Universität für Musik und darstellende Kunst Graz, Austria (2009) [8] M. Pollow, G. K. Behler, and F. Schultz, Musical Instrument Recording for Building a Directivity Database, Fortschritte der Akustik: 36. Deutsche Jahrestagung für Akustik (2010) [9] M. Pollow, B. Masiero, P. Dietrich, J. Fels, and M. Vorländer, Fast Measurement System For Spatially Continuous Individual HRTFs, 25th AES UK Conference: Spatial Audio in Today s 3D World, York (2012) [10] J. Krämer, F. Schultz, M. Pollow, and S. Weinzierl, Zur Schalllleistung von modernen und historischen Orchesterinstrumenten I: Streichinstrumente, Fortschritte der Akustik: 36. Deutsche Jahrestagung für Akustik (2010) [11] E. Detzner, F. Schultz, M. Pollow, and S. Weinzierl, Zur Schalllleistung von modernen und historischen Orchesterinstrumenten II: Holz- und Blechblasinstrumente, Fortschritte der Akustik: 36. Deutsche Jahrestagung für Akustik (2010) [12] M. Pollow, G. K. Behler, and M. Vorländer Postprocessing and center adjustment of measured directivity data of musical instruments, Acoustics 2012, Nantes (2012) [13] M. Pollow, P. Dietrich, M. Kunkemöller, and M. Vorländer, Synthesis of Room Impulse Responses for arbitrary source directivities using spherical harmonic decomposition, IEEE Workshop on Applications of Signal Processing to Audio and Acoustics (2011) [14] S. Pelzer, M. Pollow, and M. Vorländer Auralization of a Virtual Orchestra using Directivities of Measured Symphonic Instruments, Acoustics 2012, Nantes (2012) 765