SignalCorrect Software and TCS70902 Calibration Source Option SC SignalCorrect software

Similar documents
Electrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

Electrical Sampling Modules

PAM4 Transmitter Analysis

Tektronix Logic Analyzer Probes P6900 Series Datasheet for DDR Memory Applications

Arbitrary Waveform Generators AWGSYNC01 Synchronization Hub Datasheet

Limit and Mask Test Application Module

C-PHY Essentials Transmitter Test Solution TekExpress C-PHY Essentials Tx

46 GBaud Multi-Format Optical Transmitter

Automated Limit Testing

Memory Interface Electrical Verification and Debug

Video Quality Monitors Sentry Edge II Datasheet

Memory Interface Electrical Verification and Debug DDRA DDR-LP4 Datasheet

5 Series MSO Serial Triggering and Analysis Applications 5-SRAUDIO, 5-SRAUTO, 5-SRCOMP, and 5-SREMBD Datasheet Serial triggering

Memory Interface Electrical Verification and Debug

Video Reference Timing with Tektronix Signal Generators

How-To Guide. LQV (Luminance Qualified Vector) Measurements with the WFM8200/8300

Analyzing 8b/10b Encoded Signals with a Real-time Oscilloscope Real-time triggering up to 6.25 Gb/s on 8b/10b encoded data streams

Memory Interface Electrical Verification and Debug DDRA Datasheet

Troubleshooting Analog to Digital Converter Offset using a Mixed Signal Oscilloscope APPLICATION NOTE

Debugging Memory Interfaces using Visual Trigger on Tektronix Oscilloscopes

Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope APPLICATION NOTE

Automatic Changeover Unit ECO8000 Datasheet

Quick Signal Integrity Troubleshooting with Integrated Logic Analyzers & Oscilloscopes

Tektronix Video Signal Generators

Video Quality Monitors

Black and Frozen Frame Detection

Automatic Changeover Unit ECO8020 Datasheet

Debugging a Mixed Signal Design with a Tektronix Mixed Signal Oscilloscope

Dual Scope Synchronization

Data Pattern Generator

Data Pattern Generator DG2020A Data Sheet

Optical Sampling Modules 80C01 80C02 80C07B 80C08C 80C10 80C11 80C12

The Benefits of External Waveform Monitors in Color Correction for Video. Application Note

The use of Time Code within a Broadcast Facility

Low Cost, High Speed Spectrum Analyzers For RF Manufacturing APPLICATION NOTE

Spearhead Display. How To Guide

Ethernet SFP+ QSFP+ Tx Compliance & Debug Solution SFP-TX, SFP-WDP Datasheet

Logic Analyzer Triggering Techniques to Capture Elusive Problems

Comprehensive Production Tool Solution for 4K/UHD, WCG and HDR Content Creation PRISM Datasheet

Network Line Card Testing using the TDS3000B DPO Application Note. Line Card Testing Example: Throughput = Shippable Dollars

Serial Triggering and Analysis Applications. Bus display. Bus decoding. Key features. Results table. Wave Inspector search

Timesaving Tips for Digital Debugging with a Logic Analyzer

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Optical Sampling Modules 80C02 80C07B 80C08C 80C10 80C10B 80C11 80C12

Video Quality Monitors Sentry Edge Datasheet

MPEG Solutions. Transition to H.264 Video. Equipment Under Test. Test Domain. Multiplexer. TX/RTX or TS Player TSCA

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

Keysight Technologies Achieve High-Quality Compliance Test Results Using A Top-Quality Test Fixture. Application Note

80C00 Optical Modules for DSA8300 Sampling Oscilloscope Datasheet

Agilent N4876A 28 Gb/s Multiplexer 2:1

100G and 400G Datacom Transmitter Measurements

A Simple, Yet Powerful Method to Characterize Differential Interconnects

Troubleshooting and Analyzing Digital Video Signals with CaptureVu

Serial Data Link Analysis Visualizer (SDLA Visualizer) Option SDLA64, DPOFL-SDLA64

Coherent Lightwave Signal Analyzer

Accuracy Delta Time Accuracy Resolution Jitter Noise Floor

Keysight Technologies N4974A PRBS Generator 44 Gb/s. Data Sheet

Keysight Technologies ad Integrated RF Test Solution

RFM220 ISDB-Tb Measurement Demodulator

Video Quality Monitors Sentry Datasheet

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

TLA5000B Series logic analyzers combine debug power with simplicity and affordability

Agilent 87405C 100 MHz to 18 GHz Preamplifier

Agilent M9362A-D01-F26 PXIe Quad Downconverter

Keysight Technologies

Troubleshooting Your Design with Tektronix MSO and DPO Series Oscilloscopes

Data Pattern Generator DG2020A Data Sheet

Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note

Agilent N4876A 28 Gb/s Multiplexer 2:1

How to Guide. Closed Caption Monitoring. WFM6120/7020/7120 & WVR6020/7020/7120 Version Software

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

MultiView Zoom Simplifies Navigation of Long Records to Speed Debugging and Analysis

Analog Dual-Standard Waveform Monitor

Measuring and Interpreting Picture Quality in MPEG Compressed Video Content

Microwave/Counter/Analyzer with Integrated Power Meter MCA3000 Series Datasheet

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster

Serial Triggering and Analysis Application Modules

The XYZs of Logic Analyzers

How to Use a Mixed Signal Oscilloscope to Test Digital Circuits APPLICATION NOTE

Using Triggered Video Capture to Improve Picture Quality

R&S RT-Zxx High-Bandwidth Probes Specifications

FlexRay Physical Layer Eye-diagram Mask Testing

Evaluating Oscilloscope Mask Testing for Six Sigma Quality Standards

Installation Instructions. What This Option Provides

Memory-Depth Requirements for Serial Data Analysis in a Real-Time Oscilloscope

Agilent Series Harmonic Mixers

Keysight Technologies Decoding Automotive Key Fob Communication based on Manchester-encoded ASK Modulation

Using FastFrame Segmented Memory

Calibrate, Characterize and Emulate Systems Using RFXpress in AWG Series

Exceptional performance

Boosting Performance Oscilloscope Versatility, Scalability

Keysight N1085A PAM-4 Measurement Application For 86100D DCA-X Series Oscilloscopes. Data Sheet

Standard Definition Waveform Monitors WFM601A WFM601E WFM601M Data Sheet

Agilent Series Preselected Millimeter Mixers

TDA2320 PREAMPLIFIER FOR INFRARED REMOTE CONTROL SYSTEMS

Transcription:

SignalCorrect Software and TCS70902 Calibration Source Option SC SignalCorrect software Eye of signal after de-embed using SignalCorrect Features and benefits Measurement and de-embed: Characterize cables and fixtures and de-embed their effects to gain margin and reduce failures or costly over design. SignalCorrect allows quick characterization of cables, fixtures and other types of interconnects using the TCS70902 fast step source and the captured response on a DPO/MSO70000 series real-time oscilloscope. Based on this characterization, SignalCorrect can design a de-embed filter that compensates for the losses that occur in the interconnects, and offers a flat response, enabling signal margin recovery, leading to more accurate measurements. Eye of original signal Eye of signal through 9 inch cable Step-by-step characterization process: Easily characterize cables and fixtures and get repeatable results making the solution approachable to novice users. De-embed differential and common mode: Enables de-embed of fixtures that may have significant differential coupling and non-ideal common mode behavior. Two fast step outputs enables dual input measurements and full deembed of single ended, differential and common mode cases. Create and compare: Create multiple filters based on single measurement. Enables comparison of raw waveform with different filter designs. 9.4 ps step output: Enables de-embed for greater than 50 GHz (also dependent on oscilloscope bandwidth) useful for next generation designs. Small form factor of the step source: Makes it easy to take the source close to the Interconnect Under Test (IUT) for more accurate measurements. Stand alone source at lower cost. Same performance across all oscilloscope models. Reference sine wave output: Enables deskew to < 1 ps to the ends of the cables or fixtures for more accurate measurements. Output variation: TCS70902 outputs are based on sampling TDR technology that is well characterized for minimal changes over temperature and time. Generic API: Enables integration of the TCS70902 Calibration Source for use in other applications. www.tek.com 1

Datasheet Plot and save: Data such as calibration data, s-parameter data, filters can be plotted making it easy for visualization and saving for later use. Real-time scope based solution: Characterize a cable/fixture, design, create and apply a filter all on a real-time scope, eliminating the need for other expensive instruments. Use the same real-time scope to perform Jitter, Eye Diagram or standard specific measurements on the de-embedded waveform. Setup SignalCorrect provides a step-by-step setup process with connection diagrams to guide you in making the measurements required to characterize the interconnects under test. SignalCorrect overview The SignalCorrect software application runs on the Tektronix performance oscilloscopes. The application quickly characterizes fixtures, cables, and interconnects for accurate measurement and analysis. Using filter files produced by the application, you can de-embed probes or fixtures and embed a channel model. The output of the TCS70902 is measured to establish a baseline. A second measurement is taken after inserting the interconnect under test between the TCS70902 and the oscilloscope. The two measurements are compared to get the insertion loss of the interconnect under test. A filter is designed to compensate of for the losses in the interconnect under test and provide a flat response so that signal margin can be recovered to make more accurate measurements. 2 www.tek.com

SignalCorrect Calibration SignalCorrect guides you through selecting the calibration data to use or acquiring new calibration data. During the calibration process a reference measurement is taken to establish a baseline. During the calibration step: Factory calibration data stored on the source can be used if the Interconnect under test can be directly connected to the source. New calibration can be used in all other cases. Saved calibration data from previous calibration runs can be used to reduce time for characterization. Insertion loss SignalCorrect extracts the insertion loss of the interconnect under test. A plot of the insertion loss is also shown. Filter design SignalCorrect creates a filter that you can apply to your oscilloscope inputs to de-embed your device or interconnect under test. www.tek.com 3

Datasheet TCS70902 signal source Combined with SignalCorrect software the TCS70902 provides an easy to use solution that enables you to quickly characterize and de-embed interconnects under test for more accurate measurement and analysis. The TCS70902 Differential Calibration Source provides: Dual 9.4 ps step outputs on 1.85 mm female connectors Dual 5 GHz sine wave outputs phase matched to less than 1 ps on 2.92 mm female connectors Small form factor enables placement closer to IUT Can be used as a generic source for other applications such as deskewing oscilloscope inputs Programmatic interface to Turn the sine and the step outputs on/off Control the polarity of the step outputs Check the status of the outputs Control the output parameters like the delay, offset and level 292 Kit Phase matched 2.92 mm male to male short cables 1.85 mm male to 2.92 mm female adapters 240 Kit Phase matched 2.4 mm male to male short cables Connector kits Connector kits provide adapters and matched cables to connect your interconnects (cables and fixtures) under test to the calibration source and oscilloscope. 4 www.tek.com

SignalCorrect Specifications All specifications are guaranteed unless noted otherwise. Communication USB 2.0 host communication USB2.0 Compliant Mini USB B Device Port Fast edge in Fast edge in rise time (typical) Fast edge in levels (typical) 30 to 800 ps 10-90% rise time Supports the fast edge output of all DPO/MSO70000 series real-time oscilloscopes. -600 mv to 0 mv -150 mv to 300 mv Supports the fast edge output of all MSO/DPO70000 series real-time oscilloscopes. Step output Fast edge output connector 1.85 mm female connectors Fast edge rise time Rise (away from 0 V) time 10 ps, 10-90% Fast edge fall time Fall (toward 0 V) time 9.4 ps, 10-90% Primary fast edge amplitude (typical) Secondary fast edge amplitude (typical) Fast edge maximum repetition rate 200 mv step into 50 Ω 300 mv step into 50 Ω 10 MHz Sine output Sine wave output amplitude, peakto-peak (typical) Sine wave frequency (typical) Sine wave skew between outputs (typical) 250 mv into 50 Ω 5 GHz 1 ps www.tek.com 5

Datasheet Power Power consumption < 8.6 VA Atmospherics Temperature Operating Non-Operating 5 C to +45 C, with 15 C/hour maximum gradient, non-condensing, derated 1.0 C per 300 meters above 1,500 meters altitude. -20 C to +60 C, with 30 C/hour maximum gradient. Humidity Operating 5% to 95% relative humidity (% RH) at up to +30 C, 5% to 45% RH above +30 C up to +45 C, non-condensing Non-Operating 5% to 95% RH (Relative Humidity) at up to +30 C, 5% to 45% RH above +30 C up to +60 C Altitude Operating Non-Operating Up to 3,000 meters, derate maximum operating temperature by 1 C per 300 meters above 1,500 meters altitude. Up to 12,000 meters. Physical characteristics Dimensions Height Width Depth Weight Construction material Does not include connectors, chains, connector savers, connector covers, pushbuttons, cables, strain reliefs, rubber boot, or lock down hardware protruding from front or rear panels. 31.2 mm (1.23 in.) 116.8 mm (4.6 in.) 105.7 mm (4.16 in.) 0.48 kg (1.06 lbs.) Main chassis parts constructed of aluminum; front panels constructed of plastic laminate; circuit boards constructed of glasslaminate. 6 www.tek.com

SignalCorrect Ordering information Models Ordering nomenclature Product Description TCS70902 Calibration source 9.4 ps step output. Includes: calibration source, USB cable, power adapter, and ESD strap. 292 Kit option Adapter kit for DUTs with 2.92 mm, 3.5 mm and SMA adapters. Includes: 2 Male to Female 1.85 mm to 2.92 mm adapters and 1 phase matched pair of 2.92 mm male to male cables. 240 Kit option Adapter kit for DUTs with 1.85 mm adapters. Includes: 2.4 mm adapters. 065099900 240KIT Adapter kit for DUTs with 2.92 mm, 3.5 mm and SMA adapters. Includes: 2 Male to Female 1.85 mm to 2.92 mm adapter and 1 phase matched pair 2.92 mm male to male cables. 065100000 292KIT Adapter kit for DUTs with 1.85 mm adapters. Includes: 2.4 mm adapters. MSO/DPO70000C/DX Product Description Option SC DPO-UP SC DPOFL-SC SignalCorrect - Cable and channel characterization software. SignalCorrect - Cable and channel characterization software upgrade. SignalCorrect - Cable and channel characterization software floating license. Certifications Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats. Product Area Assessed: The planning, design/development and manufacture of electronic Test and Measurement instruments. www.tek.com 7

Datasheet ASEAN / Australasia (65) 6356 3900 Austria 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium 00800 2255 4835* Brazil +55 (11) 3759 7627 Canada 1 800 833 9200 Central East Europe and the Baltics +41 52 675 3777 Central Europe & Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France 00800 2255 4835* Germany 00800 2255 4835* Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835* Japan 81 (3) 6714 3010 Luxembourg +41 52 675 3777 Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands 00800 2255 4835* Norway 800 16098 People's Republic of China 400 820 5835 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea +822 6917 5084, 822 6917 5080 Russia & CIS +7 (495) 6647564 South Africa +41 52 675 3777 Spain 00800 2255 4835* Sweden 00800 2255 4835* Switzerland 00800 2255 4835* Taiwan 886 (2) 2656 6688 United Kingdom & Ireland 00800 2255 4835* USA 1 800 833 9200 * European toll-free number. If not accessible, call: +41 52 675 3777 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tek.com. Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. 25 Feb 2016 61W-60242-1 www.tek.com