Hardware Specifications

Similar documents
Hardware Specifications

Hardware Specifications

WaveReady WRT Gbps Extended-Reach DWDM Tunable Transponder with XFP Client Interface

Hardware Specifications

Long Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, CWDM, 3R Transponder WaveReady Transponder 740 LR CWDM

DWDM Cards. 6.1 DWDM Card Overview CHAPTER

Extended Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, DWDM, 3R Transponder WaveReady Transponder 740 XLR

Hardware Specifications

FTS-R27G-S31L-002DI. Multirate SFP 125Mbps-2.67Gbps, 1310nm, single-mode, 2km

PRE-QSFP-LR4L 100G QSFP 28 Dual Range Optical Transceiver, 10km. Product Features: General Product Description:

10Gbps SFP+ Optical Transceiver, 10km Reach

FOM-9010, FOM-9011 and FOM-9012

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

Cisco 10GBASE Dense Wavelength-Division Multiplexing XFP Modules

SNS-XFP-10GD-LR 10 Gbps Multi-Rate XFP Transceivers OC192/STM-64, 10GE or 10G FC 1310nm, Single-Mode 10Km, with Digital Diagnostics.

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

FTS-S12G-B53Y-005. SFP 1000Base-LX, BiDi, 1550/1310nm, single-mode, 5km

Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

Install Cards and Fiber-Optic Cable

Install Cards and Fiber-Optic Cable

Install Cards and Fiber-Optic Cable

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

Intel Ethernet SFP+ Optics

2.5 Gb/s Transponder with Mux/Demux (1310 and 1550 nm) 54TR Series

Dual Fiber SFP Series

10Gbps 10km Range SFP+ Optical Transceiver

Optical Add/Drop Cards

Install Cards and Fiber-Optic Cable

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

40G SWDM4 MSA Technical Specifications Optical Specifications

OC-48/STM-16 Bi-directional SFP Transceiver (40km) RBT25SI2

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

10Gbps 10km Range 1310nm SFP+ Optical Transceiver

LambdaFLEX Zero Chirp Tunable XFP Module TL8800ZPCND

IES-3162GC. >> Industrial 18-port Managed Ethernet Switch with 16x10/100Base-T(X) Ports and 2xGigabit combo ports. Industrial Ethernet Switch

The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting postamplifier

FTS-M12G-S85L-55M. SFP 1000Base-SX, 850nm, multi-mode, 550m

EMPOWERFIBER 10Gbps 2km SFP+ Optical Transceiver EPP C

Features. CPU Version. Non-CPU Version

10G SFP+ Modules. 10G SFP+ Module Series

Pluggable Transceivers Installation Guide

FX-1310-F10 10Gbps XFP Optical Transceiver, 10km Reach

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs

Specification. Small Form Factor Pluggable Transceiver (MSA) LC Receptacle SFP+ 12 Gigabit SDI TIM-A1CB1-F11

The expandable test solution to 10 Gb/s. SpectralBER. Specifications

Product Specification XFP 10G LR 20km LC Optical Transceiver

ODW-621. RS-232 Point-to-point applications

EDS-G205-1GTXSFP/G308 Series

OC-48/STM-16 SFP Transceiver (SR) RSP25SS1

LambdaFLEX Negative Chirp Tunable XFP Module TL8900NACND

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

40G SWDM4 MSA Technical Specifications Optical Specifications

CWDM / 12 Gb/s Medium Power SM Video Digital Diagnostic SFP+ Transceiver

Job Aid Server and CSS Separation Avaya S8700 Media Server

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

Fibre Optic Modem ODW-611

Small Form-Factor Pluggable (SFP) Module Installation Guide

100G-FR and 100G-LR Technical Specifications

LONWORKS Fibre Optic Converter

Ordering Information. Industrial Ethernet Solutions

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

DS3850R0112. FibroLAN broad portfolio of optical transceivers include SFP, SFP+ and XFP series

T A S A 2 N B 1 F A H

Module 11 : Link Design

Tunable SFP+ DWDM 10G 80Km ZR SLSSD-10GE-ZR-T

Single mode 9/125µm, duplex

HDMI over CAT5 HDBaseT Extender - RS232 - IR - Ultra HD 4K ft (100m)

Product Specification. RoHS-6 Compliant 10Gb/s 10km XFP Optical Transceiver FTLX1412M3BCL

Fibre optic router for TP/FT-10 LRW-112PP

LONWORKS Fibre Optic Router

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS. Logic Symbol Name/Description Note 1 - GND Module Ground 1

Fibre Optic Modem ODW-622

CWDM / 3 Gb/s Medium Power SM Video Digital Diagnostic SFP Transceiver

Applications LX xDR 10Gb. Gb/s 10km XFP Optical Transceiver

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

400G-FR4 Technical Specification

GIGALIGHT 300m XFP Optical Transceiver GX SRC

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions.

Power (dbm) λ (nm) LINK DISTANCE SDI Bit Rate Max. Link Distance (km) 3G-SDI 2.97Gbps 30 HD-SDI 1.485Gbps 30 SD-SDI 270Mbps 30

FTX-S1XG-S55L-040DI. XFP 10GBase-ER, 1550nm, single-mode, 40km

I/A Series Hardware Fiber Optic LAN Converter

XFP Optical Transceiver

XFP ZR Optical Transceiver, 80km Reach GX ZRC

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

6ch LC duplex QSFP Receiver ROSA (4ch x 6Gbps) + μ-bosa (2.5Gbps) (2km) FVQ2-4R1B-SM2

LIIN-25 FO Pigtail FC (0.9mm)

MediaCento IPX 4K. Product Data Sheet VX-HDMI-4KIP-TX VX-HDMI-4KIP-RX. Overview. Basic Features blackbox.com

XFP Bi-Directional 10G 20Km 1270/1330nmTx / 1330/1270nmRx SLXFB-XXXX-20

XFP-1020-WA/B 10Gbps XFP Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

Very Long Haul Multi-rate Gigabit Ethernet SFP CWDM Transceivers with Digital Diagnostics

1550 nm TX / 1310 nm RX / 3 Gb/s Medium Power 1-Fibre SM Video SFP Transceiver

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Perle Fast Ethernet Media Converters

Table of Contents. Headend Optical Transport OmniStar Enhanced DFB Laser [AM-OMNI-ALM-*] file:////ncs-server-xp/temp/motorola CD 2001/frames.

SHQP28-100G-LR4-B. 103/112Gb/s QSFP28 Transceiver Hot Pluggable, Duplex LC, +3.3V, 1310nm DML/PIN, Single mode, 10km, 0~70 C

Transcription:

APPENDIXA Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "\ Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. This appendix provides detailed shelf assembly hardware specifications for the Cisco ONS 15600. A.1 Shelf Specifications This section provides bandwidth specifications; slot assignments; lists of cards and topologies; shelf dimensions; Cisco Transport Controller (CTC) specifications; the LAN, TL1, modem, and alarm interface specifications; and timing, database, environmental, and power specifications. A.1.1 Bandwidth Total bandwidth: 320 Gbps Optical bandwidth: 40 Gbps per slot A.1.2 Slot Assignments Total card slots: 14 Optical cards: Slots 1 to 4, 11 to 14 Timing and Shelf Controller (TSC): Slots 5, 10 Single Shelf Cross Connect (SSXC): Slots 6/7, 8/9 A.1.3 Cards TSC SSXC A-1

A.1.4 Configurations OC48/STM16 LR16 1550 OC48/STM16 SR16 1310 OC192/STM64 LR4 1550 OC192/STM64 SR4 1310 A.1.4 Configurations 1+1 APS (point-to-point and linear) Two-fiber path protection Path protected mesh network (PPMN) Two-fiber BLSR Unprotected A.1.5 Height: 83.9 inches (2130 mm) Width: 23.6 inches (600 mm) Depth: 23.6 inches (600 mm) Weight: 500 lb. (226.8 kg) (without cards) A.1.6 Cisco Transport Controller 10/100BaseT TSC access: RJ-45 connector Backplane access: RJ-45 connector A.1.7 External LAN Interface 10/100BaseT Ethernet Backplane access: RJ-45 connector A.1.8 TL1 Craft Interface Speed: 9600 bps Backplane (CAP) access: EIA/TIA-232 DB-9 type connector A.1.9 Modem Interface Hardware flow control A-2

A.1.10 Alarm Interface Backplane (CAP) access: EIA/TIA-232 DB-9 type connector A.1.10 Alarm Interface Visual: Critical, Major, Minor, Remote Audible: Critical, Major, Minor, Remote Alarm contacts: 0.045 mm, 48 VDC, 50 ma Backplane (CAP) access: Alarm pin fields A.1.11 BITS Interface 2 DS-1 BITS inputs 2 derived OC-N outputs A.1.12 System Timing Holdover stability: Stratum 3E per Telcordia GR-253-CORE Free running accuracy: +/ 4.6 ppm Reference: External BITS, line, internal A.1.13 Database Storage Nonvolatile memory: 512 MB, IDE FLASH memory A.1.14 Environmental Specifications Operating temperature: 23 to 122 degrees Fahrenheit ( 5 to +50 degrees Celsius) Operating humidity: A.1.15 Power Specifications Input voltage: 48 VDC Input current: 80 A per channel (six channels provided) Power terminals: Lug Table A-1 lists the power requirements for each card. A-3

A.2 Card Specifications Table A-1 Power Requirements for Individual Cards Card Type Card Name Watts Control Cards TSC 58 SSXC 165 Optical Cards OC48/STM16 LR16 1550 170 OC48/STM16 SR16 1310 180 OC192/STM64 LR4 1550 165 OC192/STM64 SR4 1310 180 Table A-2 lists the power requirements for an individual fan in the fan-tray assembly. Table A-2 Power Requirements for Individual Fans Condition Watts Amps BTU/Hr. Min. at 48 V (ambient temperature less than 25 degrees 12 0.25 41 Celsius (77 degrees Fahrenheit) Max at 48 V (ambient temperature greater than 25 degrees Celsius (77 degrees Fahrenheit) 46 0.95 157 A.2 Card Specifications This section provides specifications for the TSC, SSXC, OC48/STM16 LR/LH 16 Port 1550, OC48/STM16 SR/SH 16 Port 1310, OC192/STM64 LR/LH 4 Port 1550, OC192/STM64 SR/SH 4 Port 1310, and Filler cards. A.2.1 TSC Card Specifications Table A-3 shows the TSC card specifications. Table A-3 TSC Card Specifications CTC Software TL1 Craft Interface Synchronization Interface: 10/100BaseT LAN Backplane (CAP) access: RJ-45 Speed: 10/100BaseT LAN Front panel access: RJ-45 type connector Backplane access: RJ-45 and EIA/TIA-232 DB-9 type connector Stratum 3E, per Telcordia GR-1244 Free running access: accuracy 4.6 ppm Holdover stability: 3.7 x10-7 ppm/day including temperature (< 255 slips in first 24 hours) Reference: External building-integrated timing supply (BITS), line, internal A-4

A.2.2 SSXC Specifications Table A-3 TSC Card Specifications (continued) 23 to 122 degrees Fahrenheit ( 5 to +50 degrees Celsius) Width: 1.10 in. (28 mm) Card weight: 4.0 lb (1.81 kg) A.2.2 SSXC Specifications Table A-4 shows the SSXC card specifications. Table A-4 SSXC Card Specifications Cross-Connect Connection setup time: 7 microseconds Latency: 0.5 microseconds 23 to 122 degrees Fahrenheit ( 5 to +50 degrees Celsius) Width: 2.36 in. (60 mm) Card weight: 5.0 lb (2.27 kg) A-5

A.2.3 OC48/STM16 LR/LH 16 Port 1550 Specifications A.2.3 OC48/STM16 LR/LH 16 Port 1550 Specifications Table A-5 shows the OC48/STM16 LR/LH 16 Port 1550 card specifications. Table A-5 OC48/STM16 LR/LH 16 Port 1550 Card Specifications Line Transmitter Receiver Loopback Mode Bit rate: 2.49 Gbps Code: Scrambled nonreturn to zero (NRZ) Fiber: 1550 nm single-mode Loopback mode: Facility Connectors: OGI : SONET Telcordia GR-253 Max. transmitter output power: +3 dbm Min. transmitter output power: 2 dbm Center wavelength: 1500 nm to 1580 nm Nominal wavelength: 1550 nm Transmitter: Distributed feedback (DFB) laser Note The Cisco Transport Controller (CTC) Maintenance > Transceiver tab shows the OPT levels. CTC might show OPT levels at 1 dbm more or less than the actual card OPT level. Max. receiver level: 9 dbm Min. receiver level: 28 dbm Receiver: InGaAs APD photo detector Link loss budget: 26 db minimum, with 1 dbm dispersion penalty Facility (Line) Note You must use a 19 to 24 dbm (15 to 20 dbm is recommended) fiber attenuator when connecting a fiber loopback to an OC48/STM16 LR/LH 16 Port 1550 card. Never connect a direct fiber loopback. 23 to 122 degrees Fahrenheit ( 5 to +50 degrees Celsius) Width: 1.50 in. (38 mm) Card weight: 5.0 lb (2.27 kg) SONET Telcordia GR-253 Eye safety compliance: Class 1 (21 CFR 1040.10 and 1040.11) and Class 1 (IEC 60825) laser products A-6

A.2.4 OC48/STM16 SR/SH 16 Port 1310 Specifications A.2.4 OC48/STM16 SR/SH 16 Port 1310 Specifications Table A-6 shows the OC48/STM16 SR/SH 16 Port 1310 card specifications. Table A-6 OC48/STM16 SR/SH 16 Port 1310 Card Specifications Line Transmitter Receiver Loopback Mode Bit rate: 2.49 Gbps Code: Scrambled NRZ Fiber: 1310 nm single-mode Loopback mode: Facility Connectors: OGI : SONET Telcordia GR-253 Max. transmitter output power: 3 dbm Min. transmitter output power: 10 dbm Center wavelength: 1266 nm to 1360 nm Nominal wavelength: 1310 nm Transmitter: Fabry Perot laser Note The CTC Maintenance > Transceiver tab shows the optical power transmitted (OPT) levels. CTC might show OPT levels at 1 dbm more or less than the actual card OPT level. Max. receiver level: 3 dbm Min. receiver level: 18 dbm Receiver: Positive-intrinsic-negative (PIN) diode Link loss budget: 8 dbm min., with 1 dbm dispersion penalty Facility (Line) Note You must use a 3 dbm fiber attenuator when connecting a fiber loopback to an OC48/STM16 SR/SH 16 port 1310 card. Never connect a direct fiber loopback. 23 to 122 degrees Fahrenheit ( 5 to +50 degrees Celsius) Width: 1.50 in. (38 mm) Card weight: 5.0 lb (2.27 kg) SONET Telcordia GR-253 Eye safety compliance: Class 1 (21 CFR 1040.10 and 1040.11) and Class 1 (IEC 60825) laser products A-7

A.2.5 OC192/STM64 LR/LH 4 Port 1550 Specifications A.2.5 OC192/STM64 LR/LH 4 Port 1550 Specifications Table A-7 shows the OC192/STM64 LR/LH 4 Port 1550 card specifications. Table A-7 OC192/STM64 LR/LH 4 Port 1550 Card Specifications Line Transmitter Receiver Loopback Mode Connectors Bit rate: 9.96 Gbps Code: Scrambled NRZ Fiber: 1550 nm Single mode Max. transmitter output power: +7 dbm Min. transmitter output power: +4 dbm Center wavelength: 1530 nm to 1565 nm Nominal wavelength: 1550 nm Transmitter: Lithium Niobate (LN) external modulator transmitter Max. receiver level: 9 dbm Min. receiver level: 22 dbm Receiver: APD/TIA Link loss budget: 24 db min., with no dispersion or 22 db optical path loss at BER = 1 12 including dispersion Payload Note You must use a 19 to 24 db (15 to 20 is recommended) fiber attenuator when connecting a fiber loopback to an OC192/STM64 LR/LH 4 Port 1550 card. Never connect a direct fiber loopback. OGI 23 to 122 degrees Fahrenheit ( 5 to +50 degrees Celsius) Width: 1.50 in. (38 mm) Card weight: 12.0 lb (5.44 kg) SONET Telcordia GR-253 Eye safety compliance: Class 1 (21 CFR 1040.10 and 1040.11) and Class 1 (IEC 60825) laser products A-8

A.2.6 OC192/STM64 SR/SH 4 Port 1310 Specifications A.2.6 OC192/STM64 SR/SH 4 Port 1310 Specifications Table A-8 shows the OC192/STM64 SR/SH 4 Port 1310 card specifications. Table A-8 OC192/STM64 SR/SH 4 Port 1310 Card Specifications Line Transmitter Receiver Loopback Mode Connectors Bit rate: 9.96 Gbps Code: Scrambled NRZ Fiber: 1310 nm Single mode Max. transmitter output power: 1 dbm Min. transmitter output power: 6 dbm Center wavelength: 1290 nm to 1330 nm Nominal wavelength: 1310 nm Max. receiver level: 1 dbm Min. receiver level: 11 dbm Link loss budget: 5 db min., with no dispersion or 4 db optical path loss at BER = 1 12 including dispersion Payload Note You must use a 3-dBm fiber attenuator when connecting a fiber loopback to an OC192/STM64 SR/SH 4 Port 1310 card. Never connect a direct fiber loopback. OGI 23 to 122 degrees Fahrenheit ( 5 to +50 degrees Celsius) Width: 1.50 in. (38 mm) Card weight: 12.0 lb (5.44 kg) SONET Telcordia GR-253 Eye safety compliance: Class 1 (21 CFR 1040.10 and 1040.11) and Class 1 (IEC 60825) laser products A-9

A.2.7 ASAP Specifications A.2.7 ASAP Specifications Table A-9 shows the ASAP card specifications. Table A-9 ASAP Card Specifications Carrier Card (CC) 4PIO Pluggable I/O Card Payloads SFP Support Connectors Power Contains slots for four pluggable ASAP I/O cards, which can be used to provide a variety of optical line interfaces. The CC provides 4 electrical STS-48 or Gigabit Ethernet signals to each ASAP I/O card (for 16 total) and 16 redundant electrical STS-48 matrix interfaces to the backplane. For SONET interfaces, the CC card provides pointer processing and overhead extraction/insertion. The ASAP 4PIO module is a four port multi-rate optical interface card. It has four slots for small form-factor pluggable (SFP) optics. The four ports can be provisioned on a per port basis as OC-3, OC-12, OC-48, or Gigabit Ethernet interfaces Nonconcatenated and/or concatenated payloads at STS-1, STS-3c, STS-6C, STS-9C, STS-12c, STS-24C, and STS-48C are supported. For Gigabit Ethernet interfaces, Layer 1 Ethernet transport is also implemented ONS-SE-Z1: Supports OC-3 SR-1, OC-12 SR-1, OC-48 IR-1 or GE LX ONS-SI-155-L2: Supports OC-3 LR-2 ONS-SI-622-L2: Supports OC-12 LR-2 ONS-SE-2G-L2: Supports OC-48 LR-2 Up to 16 SFP connectors (4 per 4PIO module) at front edge of card. 150 W to 200 W (maximum) 23 to 131 degrees Fahrenheit ( 5 to +55 degrees Celsius) Width: 1.50 in. (38 mm) Card weight: approximately 6 lb (13.22 kg) SONET Telcordia GR-253 Eye safety compliance: Class 1 (21 CFR 1040.10 and 1040.11) and Class 1 (IEC 60825) laser products A-10

A.2.8 Filler Card Specifications A.2.8 Filler Card Specifications Table A-10 shows the Filler card specifications. Table A-10 Filler Card Specifications Width:1.50 in. (38 mm) Card weight: 2.5 lb (1.134 kg) A.3 SFP Specifications Table A-11 lists the specifications for available SFPs for the Cisco ONS 15600. Note The ASAP card will only accept SFPs listed in Table A-11. Table A-11 SFP Specifications SFP Interface Transmitter Output Power Min/Max (dbm) ONS-SI-622-L2 OC-12, STM-4 3.0 to 2.0 28 to 8 ONS-SI-155-L2 OC-3, STM-1 5.0 to 0 34 to 10 ONS-SE-2G-L2 OC-48, STM-16 2.0 to 3.0 28 to 9 ONS-SE-Z1 OC-3/12/48, STM-1/4/16 Receiver Input Power Min/Max (dbm) 5.0 to 0 23 to 3 (155.52/ 622.08 Mbps) 19 to 3 (1250 Mbps) 18 to 0 (2488.32 Mbps) Table A-12 provides cabling specifications for the SMF SFPs. The ports of the listed SFPs have LC-type connectors and the minimum cable distance for all SFPs listed is 6.5 feet (2 m). Maximum cable distance for all SFPs listed is 328 ft (100 m). Table A-12 Single-Mode Fiber SFP Port Cabling Specifications SFP Wavelength 1 Fiber Type Cable Distance ONS-SI-622-L2 1550 nm 9 micron SMF 80 km (49.71 mi.) Long Reach ONS-SE-2G-L2 1530 nm 9 micron SMF 80 km (49.71 mi.) ONS-SE-Z1 1310 nm 9 micron SMF 15 km (9.3 mi.) ONS-SI-155-L2 1530 nm 9 micron SMF 80 km (49.71 mi.) 1. Typical loss on a 1310-nm wavelength SMF is 0.6 db/km. A-11

A.3 SFP Specifications A-12