Channel Controller for Light Show with Remote Control. HomLiCon RCL164R

Similar documents
21 Channel Light Show PWM LED Controller with Remote Control

Part No./ 型号 : RGB-Controller-101

KNX Dimmer RGBW - User Manual

Please read this manual before using the C961 Display. Suzhou Bafang Electric Motor Science-Technology Co., LTD

The UK sequence is shown below. The duration of each phase can be easily adjusted during the programming to suit.

CT-DMX-300 LED Controller

HS-509 VIBRATION TRIP MODULE

Wireless Symphony LED Remote Controller with Screen Manual

Dimming actuators GDA-4K KNX GDA-8K KNX

Manual for WMR-252 built-in receiver with universal dimmer

LT-300 LED Controller

Luminaire installation box Surface-mounted box Ceiling installation box

Product Specification

AT450SAW Programmable Selective Amplifier

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

User manual. EVBIKE - LCD display C961

LCD Thermometer / Clock S No. 1253

HTP1502W1 Remote Controlled Multicolor Lighting System

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

MINI HIGH SPEED DOME CAMERA. User Manual

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

STX Stairs lighting controller.

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

SceneStyle2 User Guide

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

K9123, K9134, K9135 Remote Programming Instructions and Specifications

AT47SAW Programmable Selective Amplifier

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Complete Train Control. Run Your Trains, Not Your Track!

PRODUCT MANUAL LUMENTO X3 LED. LED Controller ZN1DI-RGBX3. Program Version: 1.0 Manual Edition: a

BLOCK OCCUPANCY DETECTOR

Light-It Decoder p/n Lighting decoder w/built-in white LED

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

RGB-3400-X RGB SEQUENCER / 3-CHANNEL UNIVERSAL LED DIMMER

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

Product Description. NAME: RF 8-key Controller MODEL: 32443

Complete Train Control. Run Your Trains, Not Your Track!

CONTROLLER STYRRING. LITE A/S. Østre Fælledvej 11, 9400 Nørresundby. t: m:

Owner s guide How to use your new Opalum Furniture Sound System

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

Installation Instructions

Operating Instructions

KNX / EIB Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 136

ATS50SAW Programmable Selective Amplifier

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

LED Backlight for Technics amplifiers

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Model IQ4-PC User Manual Revision Date:

T Series LED Remote Controller

LEVEL CROSSING MODULE FOR LED SIGNALS LCS2

LT A LED RGB Controller. User s Manual

AF-300 E11 Adjustable Frequency Drive

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

GAUGEMASTER PRODIGY EXPRESS

Aspect 2 Circuit Digital Scene Control

IP Roombox. Hotel Room Management

T Series LED Remote Controller

SHUTTLE WITH INFRA-RED DETECTION SAS2-IR

Winmate Communication INC.

RGB LED Controller and Dimmer Pro Plus RF Remote 3-Channels, 12 or 24 VDC Part No. RGB-3-Dimmer-Pro

Electrical connection

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

EA350. Generator Automatic Voltage Regulator Operation Manual

OWL micro+ WIRELESS ELECTRICITY MONITOR

DZ143. Z Scale. Mobile Decoder 1.25 Amp/2 Amp Peak 4 FX 3 Functions, 0.5 Amp. Fits Many Z, N and HO Scale Locomotives

POINTS POSITION INDICATOR PPI4

Basic Manual Light-DEC

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. KNX LED dimmer Constant voltage 4gang with power adaptor 6155/40-500

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

INSTRUCTIONS FOR USE Pro-Ject Receiver Box S

CMSDI G-SDI Matrix

EVC300i. Generator Automatic Voltage Regulator Operation Manual

IEFIS G3 Inputs, outputs and Alarms

Package Contents. LED Protocols Supported. Safety Information. Physical Dimensions

EVC600i. Generator Automatic Voltage Regulator Operation Manual

IMPORTANT SAFETY INSTRUCTIONS

2002 Martin Professional A/S, Denmark.

User Manual SM-7070WR

Multi-Zone Programmable RGB ColorPlus LED Touch Controller (Remote Control) and RGB ColorPlus LED Touch Controller (Receiver)

Behind this door is a slot for a future smart card. No smart card is included with this receiver.

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Remote Control. degraded, causing unreliable operation. The recommended effective distance for remote operation is about 16 feet (5 meters).

Sphinx II. Owner s Manual. Tube Hybrid Integrated Power Amplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 08/01/16

Complete Train Control. Run Your Trains, Not Your Track!

Standard Digital Terminal High-Definition Digital Terminal. User Guide

OPERATING INSTRUCTIONS

ATEA LED ACDC User Manual (0) ATEA LED

PRODUCT MANUAL. Chroma Flow PRO RGB LED Controller. and Receiver. Product Description. Main Functions: This manual reviews: Receiver.

Low Voltage Multifunctional LED Controller / DMX Decoder. Specification

(RGBW)

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

COLOUR CHANGING USB LAMP KIT

Twin Beam Scale Operation Manual. April Specialists in Industrial Weighing

Welcome to W light up your life

Transcription:

16 + 4 Channel Controller for Light Show with Remote Control Application: Managing dynamic illuminated advertising signs, spectacular light walls, podiums, etc. Managing groups of lamps 120V/60Hz or 230V/50Hz - 16 channels Managing groups of LEDs and LED strips - 4 channels Specifications: Number of active channels: 9 20 Number of channels 120/230V: 16 Maximum output current per channel: 0.5A Maximum output power per channel: 60W(120V) or 110W(230V) Maximum total output current: 8A Number of levels for each channel: 100/120 Number of channels 12-24V: 4 Supply voltage: 5 30V DC (by an ext. PSU) Maximum output current per channel: 2A Maximum total output current: 8A Supply voltage: 110 130V/60Hz or 200 240V/50Hz Ambient temperature: 5 40 C Dimensions RCL164R: 160 x 115 x 40 mm Dimensions Remote: 178 x 46 x 20 mm Main features: RCL164R is intended primarily for management of advertising signs. The number of the channels used can be adjusted from 9 to 20. When the number of active channels is up to 16 channels, the channels 17-20 automatically go into running lights mode with possible application as illuminated arrow signs, dynamic light figures and others. 2015 mc-kit.net Page 1

For each possible number of active channels (9 to 29) can be used up to 16 lighting effects divided into two groups: 8 effects with smooth change of light 8 effects with ON/OFF control Each of the 16 effects can be deactivated, thereby selecting only the necessary effects. Each of the programs (effects) has three phases: Filling (channels are turned on in particular order) Retention (channels remain switched on from 0 to 7 seconds) Turning off (channels are turned off in particular order) All settings can be performed by remote control from a distance up to 8 meters which can make it easier to choose the right settings, especially with bigger light objects. Settings options for all effects: Number of active channels: 9 20 Backlight - light level of the channels that are turned off Level of external illumination for ON / STANDBY of the controller through phototransistor Settings options for individual effect: Speed of channel switching Number of repetitions of effect 1 8 Retention time 0 7 seconds Warning: The device works with HIGH VOLTAGE! Touching any of the elemets of the device when plugged in can be life threatening. Outputs do NOT have protection from short circuit, overload or reverse voltage. Improper connection will lead to a damaged controller. LED must be connected by a series resistor limiting the current to nominal (in LED strips embedded). 2015 mc-kit.net Page 2

Wiring diagram: 2015 mc-kit.net Page 3

Settings and operation: All settings are performed by the included remote control. It is possible to use another remote control with NEC protocol. The settings are divided into seven groups as the main group is the choice of the number of active channels and the rest can be changed only when necessary. The access to each group is possible with combination of 2 buttons to avoid accidental changes. It is possible to test the adjustments for the current group without being saved into the memory and change the existing settings. Settings are made by pressing and releasing the buttons listed in the following order: MENU, 1 Setting the number of the active channels. After submission of this sequence the active channels turn on and the last channel turns on/off every 0.5 seconds. By buttons + and - you can set the number of active channels (the last one always flashing). To save the settings of this group and restart use, to reboot without changing the settings press. MENU, 2 Settings for the group of eight programs (effects) with gradual change of light (PWM). After submission of this sequence, Effect 1 is visualized. Button switches to the next effect (up to 8), and button - switches to previous (back to 1). The settings apply to the current effect and can be different for each effect, except the level of backlight. To deactivate the current effect and visualize the next one (previous, if next doesn t exist) press C. Activation of a particular deactivated effect is not possible. Instead, the entire group of 8 effects is activated (effect 1 is visualized) by pressing button TEST. To indicate that all 8 effects in the group are deactivated, channels 2 and 4 will turn on.. This is possible only when in another group there is at least one active effect. Adjusting the level of the backlight can be made by pressing buttons 6 increase and 9 decrease. The settings of the level apply to all 16 effects at all times and affect the perception and the speed of the programs (effects) with a smooth change of the light. It is recommended to set up the initial configuration. The ability to change the settings for each effect is used for visualization and selection of the appropriate level. After each change of the backlight, the current effect starts from the beginning. The rate for each effect is different and can be adjusted using + and - buttons. The number of repetition for the current effect can be adjusted by pressing the buttons 4 and 7, and can be from 1 to 8, where for visualization are used channels 1-8. Pressing the button once serves only for visualization. Pressing it again serves for regulation. After the visualization the current effects start from the beginning. The retention time for which channels remain on after the filling phase is adjusted by the buttons 5 and 8, and may be from 0 to 7 seconds. For visualization channels 1-8 are used. Pressing the button once serves only for visualization. Pressing it again serves for regulation. After the visualization the current effects start from the beginning. To save the settings of this group and restart use, to reboot without changing the settings press. 2015 mc-kit.net Page 4

MENU, 3 Settings of the group with eight programs (effects) with a rapid change of light (ON / OFF). After submission of this sequence, Effect 1 is visualized. With button can be switched to next effect (up to 8), and with - previous (to 1) The described settings apply to the current effect and are different for each effect except for the level of backlight. To deactivate the current effect and visualize the next one (previous, if next doesn t exist) press C. Activation of a particular deactivated effect is not possible. Instead, the entire group of 8 effects is activated (effect 1 is visualized) with the button TEST. To indicate that all 8 effects in the group are deactivated, channels 2 and 4 will turn on.this is possible only when in another group there is at least one active effect. Adjusting the level of the backlight can be made by pressing buttons 6 increase and 9 decrease. The settings of the level apply to all 16 effects at all times and affect the perception and the speed of the programs (effects) with a smooth change of the light. It is recommended to set up the initial configuration. The ability to change the settings for each effect is used for visualization and selection of the appropriate level. The rate for each effect is different and can be adjusted using + and - buttons. The number of repetition for the current effect can be adjusted by pressing the buttons 4 and 7, and can be from 1 to 8, where for visualization are used channels 1-8. Pressing the button once serves only for visualization. Pressing it again serves for regulation. After the visualization the current effects start from the beginning. The retention time for which channels remain on after the filling phase is adjusted by the buttons 5 and 8, and may be from 0 to 7 seconds. For visualization channels 1-8 are used. Pressing the button once serves only for visualization. Pressing it again serves for regulation. After the visualization the current effects start from the beginning. To save the settings of this group and restart use, to reboot without changing the settings press. MENU, 4 (indication - Channel 4) Speed settings of the effects (running lights) on channels 17-20. The adjustment can be made by pressing the + and - buttons. This option is available only if the number of active channels is up to 16. MENU, 5 (indication - channel 5) Mode selection: - Normal mode (effects depending on settings) - Button - Turning on all active channels TEST button MENU, 6 (indication - channel 6) Reset the user settings and return to the original (factory). To select reset press button 0, the indication becomes channel 6 and 8. If they are not stored in an interval of 3 seconds it is cancelled. 2015 mc-kit.net Page 5

MENU, 7 (indication - channel 7) Settings of the level for ON / STANDBY of the controller according to the external light. The adjustment of the level of 1 to 6 can be made with the + and - buttons. As an indication channels 1-6 are used. Level 1 ON/OFF in high brightness (afternoon / late morning)... level 5 in low light (late night / early morning). At level 6 the controller is always enabled. Channel 8 is used for indication whether the controller will be ON/OFF according to the set level and the current light conditions. Changing the brightness or the set level takes 6 second due to averaging the data in order to avoid activation from accidently directed light. In normal mode the following commands are possible: TEST, ON / STANDBY TEST, Current group of effects (PWM or ON / OFF) can be skipped and effect 1 is visualized from the other group. Arrangement of the buttons on the remote control: 2015 mc-kit.net Page 6