HP SMA BFOC. Brief instruction. Version. 4en.

Similar documents
PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Industriefunkuhren. Technical Manual. Model 7248/7248RC. Fibre Optic Converter Board ENGLISH

Single mode 9/125µm, duplex

Fibre Optic Modem ODW-611

ODW-621. RS-232 Point-to-point applications

PHOX TM. Camera Link Fiber Extender. Base Configuration KEY FEATURE APPLICATIONS PHOX-BM PHOX-BL-10/20/40/50

DIAS power supply and DIC 221 fibre optic cable coupling module

PHOX TM. Camera Link Fiber Extender. Dual Base Configuration KEY FEATURES APPLICATIONS PHOX-B2M-250 PHOX-B2L-10/20/40/50

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

Operating Instructions

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Fibre Optic Modem ODW-622

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Compact live fiber identifier with integrated optical power meter

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

LONWORKS Fibre Optic Converter

Fiber Optic GaAIAs LED OPF32_, OPF34_ Series OPF37_, OPF39_ Series OPF67_, OPF69_ Series

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

Fibre optic router for TP/FT-10 LRW-112PP

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

One channel video link With duplex data and contact closure

Optical Perfection. HIGHYAG Beam Delivery Products

Long Range Wireless HDMI/SDI HD Video Transmission Suite LINK-MI LM-SWHD01. User manual

DisplayPort Extender over 2 LC Fibers

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

BUS UNITRONIC BUS CAN

I/A Series Hardware Fiber Optic LAN Converter

I N S T R U C T I O N D A T A

LONWORKS Fibre Optic Router

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. June 2015 Part Numbers FIBER DRIVER

Analog HD video over fiber converters for smart HD CCTV

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

PreCONNECT Mobile PRODUCT INFORMATION

Compact EGC Fiber Deep Nodes A90100 and A90300

HDO750 OPTICAL AMPLIFIER FAMILY

OTS-300 Express Series Power Meters/Sources and Testers

PHORCE (standalone version)

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

PRO SERIES FIBRE-150M

RS-232 to Multi-Mode Fiber Optic Media Converter

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

LD OEM/LD PDS/LD PeCo

THE ART OF ENGINEERING

Siemens Automation. Optical link module SIMATIC NET. Network components/profibus Optical link module. Introduction 1. Description of the device 2

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Long Range Wireless HDMI/SDI HD Video Transmission Suite LINK-MI LM-SWHD01. User manual

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

SERCOS TSX CSY 84 Module V

*Prefer. 600 MHz 4K ULTRA. 60Hz, 4:4:4. over one SC-Terminated Fiber-Optic Cable EXT-DP-4K600-1SC. User Manual. Release A1

Data Sheet GU-LCT-RY-V1-10 GU-LCT-RY-V1-11

User manual. Long Range Wireless HDMI/SDI HD Video Transmission Suite

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

SPECTRO Series. SPECTRO-1-30-UV/VIS-9x1. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

R&S ZN-Z154 Calibration Unit Specifications

The Art of Engineering

Fast Ethernet to Optical Media Converter MCE300T Data Sheet

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Ethernet Media Converters

Assembly. Front view. LEDs. Parametrization interface. Power Bus

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

VGA to DVI Extender over Fiber SET

Local Control Network

VIPA Accessories. ProfiHub B BE00 Manual

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

Product Information. RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

THE ART OF ENGINEERING

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

Scope: Using Wave Division Multiplexing (WDM) for the Protection Data Interface (PDI) of the 7SD5 / 7SD61.

TC3005(LED/ELED/LASER) User's Manual

MultiMode FOMs -ST and -SMA

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

Electrical connection

DisplayPort Extender over 2 LC Fibers

IMPAC Infrared Thermometers

Miniature Synchronous/Asynchronous Fiber Optic Modems

SY-HDBT-SLIM-100S Extender Set

INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

Capacitance Level Measurement Electronic insert FEC 12

DATA SHEET. Two (2) fibers Detachable DisplayPort 1.2 Extender, DPFX-200-TR

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

OPTICAL POWER METER WITH SMART DETECTOR HEAD

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Product model and standard

Light Source. Specification & User Manual

ST800K-U Optical Power Meter. User Manual V1.0

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Operating Instructions Rev. No. 4.1 July 07, LTC and VITC Reader with Serial Interface TC 60 RLV

STD800LED Large display panel for photovoltaic systems

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

CAMTO LTD. Arc detecting system DC/AC

Aegis Electronic Group

FORWARD PATH TRANSMITTERS

Compressed Air Management Systems SIGMA AIR MANAGER Pressure flexibility Switching losses Control losses next.

PROFIBUS Optical networks with OLM

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Transcription:

HP SMA BFOC Version 4en www.helmholz.com

Application and function description The OPTopus PROFIBUS Optical Link is a normal PRO- FIBUS repeater despite its small dimensions. It permits the conversion of electrical PROFIBUS/MPI interfaces to optical PROFIBUS/MPI interfaces. It regenerates the signals with their rate of change, level, and pulse duty factor. It also provides the advantages of optical signal transmission for your PROFIBUS/MPI network. The OPTopus is deliverable with 3 different connector types: Connector type, Versatile Link¹ resp. HP, 650 nm 700-991-1AA01 Connector type, BFOC² resp. ST², 650 nm 700-992-1AA01 Connector type, SMA, 650 nm 700-993-1AA01 1. Check the bus termination setting (switch on the top of the housing). If the OPTopus PROFIBUS Optical Link is at the end of a segment, the bus termination must be ON. If the OPTopus PROFIBUS Optical Link is in the middle of a segment (for example, to start a stub line), you must switch the bus termination OFF. 2. Connection of the FO cable to the underside of the device. The following fibers can be used: Polymer optical fiber (POF) 980/1000 µm Wavelength: 650 nm Attenuation approx. 160 db/km Polymer-clad fiber (PCF³ resp. HCS³) 200/230 µm Wavelength: 650 nm Attenuation approx. 10dB/km Note: If a non-assembled POF to be used with the included connectors, please perform the steps A to C first (see reverse side). For the PCF³ resp. HCS³ assembling are extra PCF³ resp. HCS³ connectors, and a special assembly tool according to the required plug connection-technology required. You get the corresponding PCF³ resp. HCS³ plugs from your FO cable supplier.

Connect the two devices via a cross-over cable, that is, the TxD fiber of the communication partner is connected to the RxD connection of the OPTopus PROFIBUS Optical Link. Connect the TxD connection of the OPTopus to the RxD connection of the communication partner. 3. The OPTopus PROFIBUS Optical Link is plugged directly into the SUB D female connector of the PRO- FIBUS station instead of the normal PROFIBUS device connector. It is locked in place with the two screws top and bottom. The PROFIBUS station provide the OPTopus with 5 V / 100 ma. Note: Please check this in the relevant manual of the PROFIBUS station. Power Green Blue Bus termination switched on Bus termination switched off Displays the status of the OPTopus Baud rate search: flashing Baud rate found: continuous PB Red Incorrect data are being received on the PROFIBUS interface Yellow Data are being received on the PROFIBUS interface FO Red Incorrect data are being received on the FO interface Yellow Data are being received on the FO interface Note: When the power supply is connected, all the LEDs of the OPTopus light up briefly (approx. 0.5 seconds). If the OPTopus does not find a valid baud rate or if no data exchange is performed on the PROFIBUS or the FO interface, the OPTopus will perform an internal restart every 8 seconds. During this restart, the red error LEDs of the PROFIBUS and FO interface light up for 2 seconds and then the Power LED will begin to flash (repeated baud rate search).

POF-LWL Assembling A) Cutting the fibre Slide the fibre into an opening of the cutting tool and press the blade down. Note: each opening of the cutting tool may only be used for one cut of a cable. B) Removing the Fibre Cladding The length of fibre cladding to be removed is dependent on the type of fibre. Versatile Link¹ resp. HP: approx. 3 mm SMA: approx. 6 mm BFOC² resp. ST²: approx. 11 mm Note: Only use the specially designed tool (not a copper cable stripper) as otherwise the cladding of the cable can be damaged leading to higher losses in the connector and thereby to reduced range of the cable. C) Connecting the connector to the fibre BFOC² resp. ST² or SMA connector: Slide the connector over the fibre and screw the connector housing on with the lock nut. SMA connector Versatile Link¹ resp. HP connector: Slide the connector onto the fibre and press the housing sides together until they lock. Note: When attaching the connectors, make sure that the fiber ends flush with the connector at the front. The transmit or receive diode may be damaged if the fiber protrudes. Fixing the fiber too far inward can result in increased attenuation, shortening the transmission range of the system. BFOC² resp. ST² connector Versatile Link¹ resp. HP connector

Application examples Example 1: Generation of a completely electrically isolated subnetwork. PC PLC Subnetwork 1 up to 32 stations PC Subnetwork 2 up to 32 stations Example 2: Establishment of a link between two repeaters that is not subject to EMC interference. PLC PC R ON Subnetwork 1 up to 32 stations Subnetwork 2 up to 32 stations PLC R R ON ON Subnetwork 3 up to 32 stations Subnetwork 4 up to 32 stations Subnetwork 5 up to 32 stations

Dimensions (L x W x H) 64 x 40 x 17 Weight. approx. 30 g Housing degree of protection IP 20 Power supply Voltage Current consumption Permissible ambient conditions Ambient temperature during operation Temperature during transportation and storage +5 V DC typically 100 ma 0 C... +60 C -25 C... +75 C PROFIBUS interface Transmission rate 9,6; 19,2; 45,45; 93,75; 187,5; 500 Kbps, 1,5; 3; 6 and 12 Mbps automatic detection Protocol PROFIBUS DP according to EN 61 158-2:2011-09 Connector SUB-D 9-way Special features Quality assurance per ISO 9001:2008 Maintenance maintenance-free, no battery Optical interface Wavelength 650 nm Numerical aperture transmit diode 0,50 Launchable optical power/receiver sensitivity POF 980/1000 µm PCF³ resp. HCS 200/230 µm Overdrive limit receiver Max. transmission distance POF 980/1000 µm (160 db/km) PCF³ resp. HCS 200/230 µm (10 db/km) -7,5 dbm/-20 dbm -18 dbm/-22 dbm -3 dbm up to 65 m up to 250 m Note We have checked the content of this for conformity with the hardware and software described. Nevertheless, because deviations cannot be ruled out, we cannot accept any liability for complete conformity. The information in this is regularly updated. When using purchased products, please heed the latest version of the, which can be viewed in the Internet at www.helmholz.com, from where it can also be downloaded. Our customers are important to us. We are always glad to receive suggestions for improvement and ideas. 1) The Versatile Link connector is function compatible with HP-Simplex/Duplex connectors. 2) BFOC stands for Bajonett Fiber Optic Connector. This type of connector is function compatible with ST connectors. ST is registered trademark of company AT&T. 3) PCF stands for Polymer Cladded Fiber and is equivalent to HCS. HCS is a brand of Ensign-Bickford Optics Company. Helmholz GmbH & Co. KG Hannberger Weg 2 91091 Großenseebach Germany Phone +49 9135 7380-0 Fax +49 9135 7380-110 info@helmholz.de www.helmholz.com