RPAC REDLANDS PERFORMING ARTS CENTRE

Similar documents
2017 TECHNICAL SPECIFICATIONS

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE

Yan Yean Theatre Technical Specifications

Matt Dann Cultural Centre

John Leslie Theatre. Technical Specifications. Updated July 2018

The Haymarket Basingstoke Technical Specifications

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Latrobe Performing Arts Centre

Theatre Technical Specification

Technical Specifications

Esso BHP Billiton Wellington Entertainment Centre

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Alexander Theatre. Technical Specifications. Monash University VIC enter via Wellington Road

Theatre Technical Specifications

Marjorie S. Deane Little Theater

DEREHAM MEMORIAL HALL

Monash Academy of Performing Arts (MAPA) Alexander Theatre. Technical Specifications

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

CENTRE FOR PERFORMING ARTS

Dr JOHN GALLAGHER CONCERT CHAMBER

Technical Specifications

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

Technical Director of Production Andrew Quick Ext 252

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

D A R E B I N A R T S & E N T E R T A I N M E N T C E N T R E

Access to back stage is off Fletcher St on the eastern side of the building

New Theatre Royal Lincoln Technical Information

Shouson Theatre Venue Specifications (updated Jan 2017)

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Main House Technical Specification

Arcadia Performing Arts Center Technical Specifications and Information

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

Technical Specification (Studio Theatre)

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

ISLAND HALL TECHNICAL INFORMATION

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

THEATRE EQUIPMENT DECEMBER 2017

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

THEATRE Technical Specifications

JERWOOD VANBRUGH THEATRE

Technical Specification Pavilion Dance

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Mildura Arts Centre. Mildura Arts Centre Theatre. Technical Specifications. Updated 23/6/06

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Specification Ardhowen Theatre

Sandusky State Theatre Technical Specifications

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Concert Hall Technical Specifications

Monash Academy of Performing Arts

Technical Specification

332 fixed seats (max capacity) with reserved space for disable access

Technical Specification

Monash University Academy of Performing Arts

MONASH University Academy of Performing Arts

TECHNICAL RIDER. STAGE 32 m wide x 13 m deep (from setting line / mid point)

Technical Specifications Nov 2016

YOUR TOOLKIT TO AMPLIFY YOUR SHOW

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Technical Specifications and Inventory Spring 2018

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Technical Specification for the Alley Theatre, Strabane

Theatre Technical Specifications

Technical Specifications

Dale F. Halton Theater Technical Specifications

There are 10 dressing rooms in Theatre Kerkrade.

Main House Technical Specifications

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Technical Data Sheet

Powerhouse Theatre technical information and general specifications 2017

Queensland Performing Arts Centre

Darebin Arts & Entertainment Centre. Theatre

Technical Specification (Drama Theatre)

Technical Specification (Studio Theatre)

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Hopgood Theatre NOARLUNGA CENTRE

Pleasance London Main House Visiting Company Information Pack May 2017

Technical Specification. Updated: April 2016

T1 National Theater. Auditorium (Basement 1): 324 Under Balcony (Ground floor): 388 Royal Circle (Level 1): 161 Level 2: 316 Level 3: 422

Main Stage Technical Specs - Hall #2

Where performance matters

Gosford City Council

Technical Information

Technical Specifications

Concert Hall Technical Specifications

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Camden Opera House Theater. Technical Information

SHUBERT THEATER 247 College Street, New Haven, CT

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

CHELSEA THEATRE. Technical Specifications

Technical Rider. STAGE 32 m wide x 13 m deep (from the prompt)

Transcription:

RPAC REDLANDS PERFORMING ARTS CENTRE CONCERT HALL Technical Specifications STAGE FACILITIES Soft Proscenium Theatre mode (see stage masking) Concert Platform (open area with acoustic walls on PS, OP and US) Forestage Lift 14 off electric pile wind winches with lifting capacity (WLL) 500kg CONCERT PLATFORM DIMENSIONS Platform Width DS: Platform Width US: 18m 16m Platform Depth: 12.5m Platform Depth including forestage 16.1m Height of platform from auditorium level 1050mm Platform to rigging points 9.14m Forestage Lift Depth 3.6m Forestage Lift Width 13m Created 23/11/2018 1

FORESTAGE LIFT (When lift is at lowest position, a small orchestra or ensemble can be accommodated below the audience stage sightlines) Static Load Limit Working Load Limit (Dynamic lifting capacity) Uniform Distributed Load (Static or Dynamic) Maximum Point Load Speed (regardless of load) 6000kg 6000kg 7.5kPa 4.5kN 2.5 m/min FLYING SYSTEM Fixed Pile Wind Electric winches (WLL 500kg) 14 Chain Motors ¼ ton (speakers only) 3 Chain Motors ½ ton (available for hire) 3 Five line pickup (3.75m centres) 5mmwires Batten Dimensions 75 x 50 RHS Batten Length 15.6m Batten Drift 8m WLL 500kg Please note that bars cannot be swung HOUSE CURTAIN Manual Operation House Curtain is Velour with 100% fullness Traverse Created 23/11/2018 2

STAGE MASKING LEGS-Black wool with 75% fullness BORDERS-Black wool with 75% fullness TABS-Black (traverse) wool with 75% fullness CYCLORAMA-Filled cloth white Cyclorama 6 of 8m x 4m 3 of 2m x 16m 2 of 8m x 9m 1 of 16m x 8m ACCESS Loading Dock Door 3.2mW x 4.6H Load-in door dimensions (STAGE) 1.8m W x 3mH Crossover location Rear of Acoustic wall Access to grid and LX bars 25ft and 30ft EWP Created 23/11/2018 3

LIGHTING FACILITIES LIGHTING CONTROL ETC GIO with 2 x 20 fader wing Located in Bio Box at the rear of Auditorium DIMMERS JANDS HPX 12ch 2.4k 10amp Racks (4 x wall mount) 10 Patching via flexible patch system FOLLOW SPOTS Canto MK2 1200w MSR 2 The Follow Spot room is located above the Control room at the rear of the auditorium LIGHTING POSITIONS FRONT OF HOUSE BALCONY BAR - located above the last row of seating at the rear of the auditorium. There are ten x 10amp outlets spaced at 1.5m behind the rigging bar LIGHTING BRIDGE - located approximately 8m above the middle of the auditorium. There are twenty x 10amp outlets spaced at 1m behind the rigging bar LIGHTING BOOMS Two lighting booms are located at OP and PS of the auditorium (four in total). Booms are spaced approximately 4.6m apart. There are six x 10amp outlets at each boom position Created 23/11/2018 4

LIGHTING POSITIONS STAGE Five stage lighting bars with 24 x 10amp outlets are rigged in permanent positions above the stage. An additional lighting bar is rigged in permanent position above the forestage thrust. All stage lighting bars are 16m in length ALLOCATED LIGHTING INSTRUMENTS BALCONY BAR 10 of 750w ETC 19 ellipsoidal spot LIGHTING BRIDGE 24 of 1K Selecon Pacific 14/35 6 of 1K Selecon Pacific 7.5/19 FOH LIGHTING BOOMS 8 of 750w ETC 36 ellipsoidal spot 2 of 750w ETC 19 ellipsoidal spot 2 of 750w ETC 50 ellipsoidal Spot STAGE 36 of Pro Shop HEX18 RGBWAUV LED PAR 18 of 1.2k 80v Selecon Pacific Rama Fresnels 8 of 750w ETC 36 ellipsoidal spot 4 of 750w 26 ellipsoidal spot 14 of Selecon PLCYC 2 RGBW LED units FORESTAGE 6 of 1.2k 80v Selecon Pacific Rama Fresnels Additional lighting equipment including moving lights can be obtained for hire on request to the Technical Manager Created 23/11/2018 5

SOUND FACILITIES MIXING DESK 1 of Yamaha LS9 32 channel mixer The mixer is located between/behind the middle of the last row in the house and can be moved to the Bio Box on request to the Technical Manager DIGITAL STAGE RACK 1 of Yamaha Rio3224-D L&R SPEAKERS 12 of d&b audiotechnik Yi8 loudspeakers (30D amplifiers) (Permanently rigged and patched) CENTRE SUB SPEAKERS 4 of d&b audiotechnik Yi subwoofers (30D amplifiers) (Permanently rigged and patched) FRONT FILL 6 of d&b audiotechnik E4 loudspeakers (10D amplifier) SIDE FILL 4 of d&b audiotechnik 12S loudspeakers (30D amplifier) (Permanently rigged and patched) FLOOR MONITOR SPEAKERS 10 of d&b audiotechnik MAX2 monitors (D20 amplifiers) FLOOR MONITOR SUB SPEAKER 1 of d&b audiotechnik 18S subwoofer (D20 amplifier) CD PLAYBACK CD RECORDER (CD player/recorder) 2 of Denon DN-C615 1 of HHB CD 830 PLUS Created 23/11/2018 6

SOUND FACILITIES cont MICROPHONES Large Selection available for hire WIRELESS MICROPHONES 16 channel Sennheiser 2000 series handheld and bodypack transmitters COMMUNICATIONS Clearcom 4 channel Talkback System Leon Audio 14 channel Cue Light Station WILLIAMS SOUND INFRARED HEARING ASSIST SYSTEM Automated acoustic blankets are fitted to the walls of the auditorium and may be flown in or out on request to the Technical Manager. AUDIO VISUAL Panasonic PT-DW11KE DLP projector (equipment hire) - Panasonic ET-D75LE50 Fixed Short Throw Lens - Panasonic ET-D75lE6 Short Short Throw Zoom Lens - Panasonic ET-D75LE10 Long Throw Zoom Lens STUMPFL 24 x 13 6 16:9 MONOBLOX 64 projection screen with rear and front projection skins (equipment hire) Roland V-800HD MK II video switcher (equipment hire) Krammer VP-728 Switcher/Scaler (equipment hire) Blu-Ray player (equipment hire) MacBook with ProVideoPlayer2 (equipment hire) Created 23/11/2018 7