Axio Vert.A1 Simply Get All Information from Your Cells

Similar documents
CONFOCAL MICROSCOPE. Instrument Details: Make: Zeiss. Modal: LSM 700. Specifications: Microscopes

Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 53 Cooling incubators with thermoelectric cooling

120cm (4x36 Watt) incl. Splitter Instruction Manual

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model KT 170 Cooling incubators with thermoelectric cooling

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

LED MODULES READYLINE DL

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

Centrifuge 5418/5418 R

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Features. Typical Applications

Indiana Center for Biological Microscopy. Zeiss LSM-510. Confocal Microscope

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Surgical Solutions. Brilliance. Focus. Comfort. HarmonyAIR M-Series Surgical Lighting System. One Integrated Approach to Healthcare

Actuators IC 20, IC 40

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Quick-disconnect cables. Adjustable mounting brackets

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

ABB. Measure IT Uvisor System MFD Multi Flame Detector - Control Unit. Product Data Sheet (Rev. C)

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Model ED 23 Drying and heating chambers Classic.Line with natural convection

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

Photoelectric Sensors E3F2

KARL STORZ GI SILVER SCOPE Series

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Quick-disconnect cables. Adjustable mounting brackets

Model KBF 115 Constant climate chambers with large temperature / humidity range

Gamma instabus. Technical product information

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

X-Cite XLED1. Advanced LED Illumination for Fluorescence Microscopy. Resetting the standard for LED illumination

Steady-Lite Model 13plus Variable Intensity Fluorescent Illuminator High Frequency (85 khz) - Lite Mite Series

VAT 20 Adjustable Frequency Drive

Operating Instructions Dimmer for V Incandescent Lamps

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

Type: DILM25 10(24V50HZ) Article No.:

PRELIMINARY Sunny Boy 240-US

SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL

Type: DILM12 10(24VDC) Article No.:

Quick-disconnect cables. Adjustable mounting brackets

Model KBF 720 Constant climate chambers with large temperature / humidity range

Manual for WMR-252 built-in receiver with universal dimmer

Modular pulse operated latching relay 16 A

HDMI Over Single Coax Extender

MX215. Your advantages. 2MP Medical-Display

Fusion 120 Zoom. User Manual. Order code: EQLED068

Re-defining the utility-scale inverter

PAM-1840 Preamplifier Operation Manual

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Cylindrical Photoelectric Sensor CY-100 SERIES

LED Driver Linear / area fixed output

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

V 180 Series Photoelectric Switches

CTC Series. Compact Temperature Calibrator

LED STADIUM LIGHTING WS-STAD-xxx Gen6

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

721N Spectrophotometer. Operating Manual

GI V E YOUR TA LENT THE TOOL S IT DESERV ES.

LD OEM/LD PDS/LD PeCo

Product Data Sheet 4650 N-465

High performance circuit breakers

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Caveled Tunnel Lighting Series. SL-Caveled/100277AC (UL) - B Type - UL certified (E326344) Features. Typical Applications.

KRF EMC Filters Installation, Operation and Maintenance Manual

Product Description Sheet Loctite CL10 Quad LED Controller

Product Data Sheet 4656 EZ

MonoBright LED DAYLIGHT 750

LED Driver Compact fixed output

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

InSight Pro. Valuable real-time process insight

Generator protection relay

Henkel Installation Handbook LINEGUARD 2001

Product Data Sheet 4656 ZW

Safety Light Curtains

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

Simply clever! The digital DIN-rail time switches by Grässlin

18W Low Energy Dusk-Dawn Bulkhead E-290B

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

LFV2 Series. LFV2-CP Series. LFV2-5 Series LFV2 50 RD LFV2-35 LFV2-CP-13 LFV2-CP-18 LFV2-50 LFV2-70 LFV2-5-2 LFV2-100 LFV2-5-5 LFV2-130 LFV2-5-12

Catalogue Ignitors and power switches for HID

DUCAT-IV Adjustable Aim Recessed LED Downlight

IP Roombox. Hotel Room Management

Customer Responsibilities. Important Customer Information. Agilent 1260 Infinity Clinical ed. LC Site Preparation Checklist

Product Data Sheet 8506 VW-691

Optical Component Environmental Test System

ORDER CODE: EQLED65 USER MANUAL

intro Automation for swing gates with leaves up to 4 m Kg, undergroung installation

Prisma Optical Networks Ancillary Modules

LTC 46xx and LTC 47xx Series Fiber Optic Transmission Units

LTC 4600 and 4700 Series Fiber Optics

Features. High Brightness SMD LED Light source

CITOCUT Plasma inverter cutting range

If you have questions or problems in providing anything described as Customer

Transcription:

Product Information Simply Get All Information internet-link Release 1.0

All Contrasts. All Information. All Flexible. In Brief Choose from all standard contrasting techniques, including DIC, to investigate your cell cultures. produces brilliant images to answer your questions. is the only system in its class with such a large range of features, compact enough in fact to sit directly beside your incubator. Look into the very essence of your research while keeping your cell culture in its own protected environment. 2

: Simpler. More Intelligent. More Integrated. The Advantages Using All Standard Contrast Techniques, It s in a Class of its Own Brightfield, Phase contrast, PlasDIC, VAREL, improved Hoffman Modulation Contrast (ihmc) and Fluorescence contrast s range reads like an index of contrast techniques. Alone in its class, it also employs Differential Interference Contrast. With DIC you visualize even the finest structures in your cells. And the new IVF contrast system is particularly impressive in IVF labs: without modifying the stand, you can switch freely between ihmc, PlasDIC and DIC as you investigate your samples. LED Excitation Gentle on Your Living Samples You are working with fluorescence-labeled cells or specify transfection rates? With your samples remain safe in gentle LED light. This microscope brings you tomorrow s standard today: LED excitation has no unwanted UV component, so you will see a significant increase in the survival rate of your cells. Profit from an extremely long life time of the light source. Homogeneous illumination saves you time and bother on adjustments. LED illumination immediately works with full intensity there is no heating and cooling period required. Ergonomic Design Makes Your Work Easier Ease of use is built right into : Whether you are sitting or standing, simply use intermediate pieces to work comfortably in an upright position. The ergo tube lets you tilt the eyepieces as much as you need. You can always view your samples easily. Thanks to ergonomic design of all operating parts, your routine tasks and workflows will be easier especially when you re in a particular hurry. 3

Your Insight Into the Technology Behind it The IVF contrast system unites ihmc, PlasDIC and DIC without mod ification The new IVF contrast system is particularly effective in IVF labs: switch at will between ihmc, PlasDIC and DIC without modifying the stand. unites all three contrast techniques in one condenser and gives you enough room for micromanipulation. The stable transmitted light arm provides precision you can rely on Adapt all standard micromanipulators to the stable transmitted light arm of your. Your work will be free of vibration: you regulate your movements under the microscope with extreme precision. The Applications ihmc reveals even finest structures in the cell nucleus PlasDIC improves your ICSI results DIC delivers brilliant images for IMSI You examine embryos and assess cell nuclei? ihmc shows nucleus shape and nucleoli brilliantly. Structures such as the Zona pellucida of oocytes are brought out particularly well by PlasDIC contrast technique. You can judge precisely where to inject, thanks to the strong and brilliant relief effect. Top marks to DIC with IMSI for producing brilliant images at high magnifications. You can easily assess the shape and vacuole count of sperm cells. Embryo: Nucleus with nucleoli visible in right cell ICSI: Oocyte with Zona pellucida IMSI: Vacuoles in sperm cells ihmc PlasDIC DIC 4

at Work The Applications Keratinocytis of epidermis - DIC HeLa cells - PlasDIC Embryo: nucleus with nucleoli visible in right cell - ihmc HeLa cells - Phase contrast Tobacco, protoplasts - Brightfield HeLa cells - 2-channel fluorescence 5

: Your Flexible Choice of Components. 5 4 2 3 The System 1 1 Microscope, transmitted light FL, transmitted light and fluorescence FL-LED, transmitted light and LED fluorescence 2 Objectives A-Plan LD A-Plan LD Plan-NEOFLUAR 3 Illumination Transmitted light: halogen lamp, LED (wavelength 400 to 700 nm, peak at 460 nm) Reflected light: HBO 50, HBO 100, HXP 120 C, LED modules (wavelength, nm): 365, 385, 420, 445, 455, 470, 505, 530, 590, 615, 625 or neutral white: 540-580 nm 4 Cameras Recommended cameras: AxioCam ERc 5s AxioCam ICc 1 AxioCam ICc 3 AxioCam ICm 1 AxioCam MRc AxioCam MRm 5 Software ZEN lite ZEN pro 6

: System Overview The System 7

Technical Specifications Technology and Details Microscope FL FL-LED Stand Dimensions (W x D x H, including required space for cabling and plugs) manual inverted stand, transmitted light manual inverted stand, transmitted light and fluorescence manual inverted stand, transmitted light and LED fluorescence 235 x 560 x 560 mm 235 x 560 x 560 mm 235 x 560 x 560 mm Weight 10.5 kg 11.7 kg 12.3 kg Eyepieces Field number 23 (W-Pl 10x/23 br foc), diameter: 30 mm 8

Technical Specifications 5x, H M27 H, 3x H Objective m n n 1.25x-100x Contrast methods (transmitted h n Technology and Details Illumination n m h Hal 100 (Halogen) 37 W, 1,5 to 12V 3 W, 1,5 to 12V n 90 VA 155 VA 120 210 VA n mount for for light n reflector for light included with stand optional not possible 9

Technical Specifications Technology and Details Accessories FL FL-LED Tubes Binocular tube 45, 23 Tubes, Ergo intermediate pieces Condensors Stages Accessories Binocular phototube, left 45, 23 (50:50) Binocular phototube, 45, 23 (50:50) Binocular ergotube, 30-60, 23 Intermediate phototube, H=50 mm, left port Ergo intermediate piece, H=25 mm for optimization of viewing height Ergo intermediate piece, H=50 mm for optimization of viewing height LD-condensor 0,3 for slider LD-condensor 0,4 for slider LD-condensor 0,4 for H Ph PlasDIC DIC ihmc LD-condensor 0,55 for H Ph PlasDIC DIC Specimen stage with optional object guide M for various mounting frames M Mechanical stage 130x85 R/L with short coaxial drive for various mounting frames K Gliding stage Z with stage inserts Scanning Stage 130x85 mot P; CAN for various mounting frames K Aquastop Mounting frames, heatable mounting frames, incubators Micromanipulation included with stand optional not possible 10

Technical Specifications Technology and Details Operational data Area of use Closed spaces Protection class / protection type I, IP 20 Electrical safety Overvoltage category Radio interference suppression acc. to DIN EN 61010-1 (IEC 61010-1) allowing for CSA and UL specifications II acc. to EN 55011 Class B Interference immunity acc. to DIN EN 61326-1 Power supply 100 to 240 V AC ±10 % Power frequency Power consumption internal mains adapter Power supply for HBO 100 Area of use 50 to 60 Hz max. 80 VA Closed spaces Protection class / protection type I, IP 20 Power supply Power frequency Power consumption with HBO 100 100 VAC... 240 VAC 50/60 Hz 155 VA Power supply for HBO 50 Area of use Closed spaces Protection class / protection type I, IP 20 Power supply 100 to 240 V AC ±10 % Power frequency 50 to 60 Hz Power consumption HBO 50 max. 90 VA Power supply for HXP 120 C Power supply 100 bis 240 V ±10 % Power consumption HXP 120 C max. 210 VA 11

Technical Specifications FL-LED LED-illumination in reflected light with changeable LED modules, wavelengths 365, 385, 420, 445, 455, 470, 505, 530, 590, 615, 625 nm or neutral white (540-580 nm) LED-classification LED-risk group 1 acc. DIN EN 62471:2009 FL Wave length 400 to 700 nm, peak at 460 nm LED-classification LED-risk group 1 acc. DIN EN 62471:2009 Technology and Details Fuses acc. to IEC 127 Stand Power supply for HBO 50 Power supply for HBO 100 Power supply for HAL 100 T 3,15 A/H, 5x20 mm T 1,6 A T 2,0 A/H, 5x20 mm T 5,0 A/H, 5x20 mm 12

Count on Service in the True Sense of the Word Your results really matter to us: we want you to get the best you expect from your microscope. Depend on Carl Zeiss and Sheerin Scientific for everything you need: technology, software, advice and service. We stay with you long after installation of your microscope on site. Sheerin Scientific specialists will continue to maintain your systems, repair them, supply spare parts and much more. Just call us: we are always here for you. Total Protection with Your Sheerin Scientific Service Contract It s the safe and practical way to preserve the efficiency of your microscope system. Our service contract protects you against expensive downtime. Preventive Maintenance Plus Optimizes Performance Our specialists will maintain and tune your system at regular intervals. You get valuable advice and comprehensive answers to any and all questions. We will also keep you right up to date on developments in your field of application. The Standard Contract Also Includes Repairs and Support Sheerin Scientific provides maintenance and repairs on all major brands of microscopes from the basic to the most complex. With over 30 years of experience, our service technicians are certified and warrant all of their work. Our technicians work within your lab to perform preventative maintenance on your microscope equipment. It is sometimes necessary to provide loaner equipment to keep our customers from being without a microscope. 13

The moment technology provides you with a result the first time. This is the moment we work for. 14

facebook.com/sheerinscientific youtube.com/zeissmicroscopy 9860 Pflumm Road Lenexa, KS 66215 Sales & Service E-Mail: sales@sheerinscientific.com