Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

Similar documents
Manufacturer since 1873

Cooling systems for ORBIMAT

Model KT 115 Cooling incubators with thermoelectric cooling

Model KBF 115 Constant climate chambers with large temperature / humidity range

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Model KT 53 Cooling incubators with thermoelectric cooling

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Magnetic Stirrers Magnetic Stirr

UNIGAS Hand-held combustion gas analyzer with 3 sensors

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Hotplate/Stirrers. Performance, Selection, Control

Model ED 400 Drying and heating chambers Classic.Line with natural convection

IKA Analytical line Calorimeters C 2000

Model KBF 720 Constant climate chambers with large temperature / humidity range

Model KT 170 Cooling incubators with thermoelectric cooling

ROTARY EVAPORATOR BOECO ROTARY EVAPORATOR RVO 400 SD

Pipe Testing. Peel resistance page 4. Cathodic Disbonding page 7. Indentation hardness page 9. According to ISO, DIN, CAN/CSA standards

Küba comfort DP. Draught-free ventilation and extremely quiet operation

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Model KMF 240 Constant climate chambers with expanded temperature / humidity range

DMP 331i / DMP 333i LMP 331 i

IMPAC Infrared Thermometers

Bartels Micropumps. ( ) Rev. 2.8

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

Level Measurement silometer FMC 420, FMC 423

CTC Series. Compact Temperature Calibrator

TUC: Universal thermostat

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Up to 85% higher Service Life due to efficient sealing method.

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Immersion Pumps HCT (High Chem) sealless

LABSONIC M The ultrasonic homogenizer for every application. Benefits

TENSIONED ELPRO CONCEPT Motorized projection screen for wall or ceiling installations

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

2x2 HDMI Matrix Switch - 4K with Fast Switching and Auto-Sensing

2.9 Sigma/ 2 Plunger Metering Pumps

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

PROPORTIONAL VALVES Sentronic plus

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

IONIVAC Transmitter ITR 90

Programat CS2. Fast and easy for flawless. IPS e.max CAD restorations. The glazing and crystallization furnace

Engineered to meet your needs T he oldest name in stud welding,

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Panel-Mounted Thermostat

Infra-Red Vortex-Evaporator. User manual Version 3.4

Programat P310. Economical firing performance. Top-quality results. The user-friendly furnace. Now with new OSD display

PRESTOJET Plasma inverter cutting range

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Centrifuge 5418/5418 R

Solenoid valves VZWD, directly actuated

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Bimetal Temperature Switch

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

OPTICAL POWER METER WITH SMART DETECTOR HEAD

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

SHARP Plasma inverter cutting range

Solenoid valves VZWD, directly actuated

User Manual RTHDBT402PT & RTHDBT402PR

CITOCUT Plasma inverter cutting range

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:

Series description: Wilo-Jet HWJ

VarioSynergic 3400 / 4000 / 5000 VarioSynergic / / MIG/MAG welding PERFECT WELDING

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Selection Table. Ordering Information

VLHDMIEXTFIB_2017V1.0

Oscilloscopes for field applications

ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Hybrid Chart Recorder 250 mm (10")

VBOX 3i Dual Antenna Measures Slip and Pitch/Roll (RLVB3iSL)

CITOCUT Plasma inverter cutting range

Gear Pump Units For single-line centralized lubrication systems

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

P-2 Installing the monitor (continued) Carry out as necessary

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

515 PIPEMASTER. Features. Options PROGRAMMABLE POWER SOURCE FOR ORBITAL WELD HEADS

Colour Explosion Proof Video Camera USER MANUAL VID-C

DIGITAL STROBOSCOPE OPERATION MANUAL. Model : DT-2239A

Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer

Data Pattern Generator DG2020A Data Sheet

Agilent High Capacity RV Pumps & Roots Pumping Systems

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

Transcription:

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic) ISO 1516, ISO 1523, ISO 13736, DIN 51755-1, DIN 53213 (obs.), EN 456 (obs.), EN 924, IP 113 (obs.), IP 170, IP 304-1 (obs.), IP 304-2 (obs.), IP 491, IP 492, NF M07-011 (obs.), NF M07-036, NF T66-009, BS 3442-2 (obs.) Product group(s): User group(s): Scope: Flammability Biofuel, Fuel, Paint, Solvent, Varnish The Abel-Method describes the determination of the closed-cup flash-point of petroleum products and other liquids having flash-points between -30 C and +70 C. The Equilibrium-Method describes the determination of the closed-cup flash/no flash temperature of paints, varnishes, paint binders, solvents, adhesives, petroleum & related products between -30 C and +110 C. The Abel-Pensky-Method describes the determination of the closed-cup flash-point of petroleum products and other combustible liquids having flash-points between -30 C and +65 C. Extended Measuring Range up to +110 C for greater versatility. Allows users to go beyond the conventional scope of the Abel method. Economical Standard Version for the operating span +10 C to +110 C with fan-cooled Peltier elements. This avoids messy tubing on the laboratory bench and minimizes cooling water usage. Low Temperature Version for an operating span of -30 C to +110 C. Requires limited tap water (lowest achievable temperature -20 C) or a small coolant circulator. Barometric Pressure Correction by a built-in pressure sensor to measure the pressure directly at the ABA 4. User Definable Test Programs to make customized test methods. Equilibrium-Simulation Mode Search Mode saves time, when a flash-point of a sample to be tested is not known. Rapid Heating Mode for samples with a high flash-point. The sample is first heated with boosted power and then the heating rate is automatically reduced to the standardized rate when approaching the critical testing phase. Compact Design occupies a bench-top area of only 23 cm wide and 47 cm in depth. Effectively using the work bench depth and not wasting its valuable length. A serious consideration when the ABA 4 is placed in a fume hood. Easy to operate: Insert the filled test cup, complete with the lid and shutter assembly, plug-in the multi-detector and shift the multi-function-head - ONE TWIST into its test position. All electrical connections and the coupling of the stirring motor are carried out automatically. Pressing a key selects the suitable test method from a list of programmed standards or one of the self defined USER-programs. Or simply recall one of the stored test runs from the program library. Even better: FPPnet software allows remote control of the ABA 4 and test data storage capability on a PC. Two igniter systems: gas flame and electrical igniter are both included. The performance of the electrical igniter is permanently checked, which results in better reproducibility and a longer life of the igniter. This control also signals when the igniter is to be changed, possibly due to excessive aging or damage. If the gas flame is used, a sensor watches the ignition flame and causes an automatic relighting or stops the test, if this should not be possible. Outside Flame Sensor for samples having no conventional flashpoint (e.g. due to flame inhibiting components) but burn outside the test cup. Probe Verification Program checks the proper function of the temperature probe and allows a bias adjustment, using a special accessory kit. automatic Barometric Pressure Correction 2 User Definable Test Programs Equilibrium-Simulation Mode Peltier element system (only for air cooled version) Rapid Heating Mode swivel-around Multi-Function-Head - ONE TWIST integrated Flame Sensor Software Windows compatible Page: 1

Flash-Point Abel Test Equipment to be composed of: - Flash-Point Tester - ABA 4 (air cooled or liquid cooled) - Circulation Cooler - Hose-Set Technical Data Temperature Range: Programs: Ignition Type: Stirring Speed: Sensing System: Barometric Pressure Sensor: Safety: Hardware Clock: Interface: Gas Connection: +10 to +110 C (internal cooled) -30 to +110 C (external cooled) (according to international standards) 2x ISO-Standards 2x Rapid-Heating 2x Search Run 2x Equilibrium 2x User Defined (Abel-Pensky Meth. preset) gas and electric (included) 0 and 100 rpm (adjustable) differential-thermocouple Automatic Barometric Pressure Correction overheat protection automatic shut-off Included RS232 for printer RS232 for computer download (USB-converter available) for propane/butane or natural gas (max. 0.05 bar) Display: selection of C or F high x wide: 56 x 90 mm digit size: 25 mm Dimensions: Width 230 mm Depth 470 mm Height 460 mm Weight 8 kg, net Power Consumption: approx. 180 Watts Power Supply: 230/115 V, 50/60 Hz (selectable) Main Unit 12-0501 / 107097 ABA 4 - Automatic Flash-Point Tester Abel Method (air cooled) Abel Method: IP 170 (BS 3442-2) - ISO 13 736 (NF M07-011) Abel Bitumen Method: NF T66-009 (IP 113) Equilibrium Method: ASTM D 3941 - ISO 1523 - IP 492 (IP 304-1) - EN 924 Equilibrium Method (flash/ no flash): ASTM D 3934 - ISO 1516 - IP 491 (IP 304-2) with further accessories for: Abel-Pensky Method: DIN 51 755-1 - NF M07-036 (DIN 53 213) high-grade stainless steel housing with two-color powder coating, touch-key panel with large LC-display (visible in up to 10 m distance), swivel-mounted Multi-Function-Head - ONE-TWIST, stirrer drive, two RS232-interfaces for data printer and computer connection, different test-programs, data-transfer and software upgrading through bi-directional interface, Peltier element system, automatic barometric pressure control (correction), automatic overheat protection, power controlled/monitored electric igniter, gas igniter with auto-relighting and safety shut-off, re-cooling fan Page: 2

PC-Software "FPPnet" (Windows ): A control & analysis program for easy handling, data storage and program transfer. Providing online display of sample & heater block temperature, gradient (also in an XY-diagram) and test status. Easy to read tableau indicating: sample no., sample name, C/ F, expected flash point, program, status, found flash point, corrected flash point, corrected rounded flash point. Test results are stored together with all program and device parameters in one file. The simultaneous connection of different Petrotest flash point devices is possible. To simplify the device management they can be named individually. Supplied with: 1 cup "ABA" 1 cover "ABA" 1 multi-detector "ABA" 1 gas igniter 1 electric igniter 1 stopper 1 tong for cup 1 tray for cup and multi-detector 1 stirrer coupling 1 PC-software "FPPnet" Temperature Range: +10 to +110 C (+50 to +230 F) Power supply: 115/230 V, 50/60 Hz, 180 W, EU-plug 12-0502 / 108319 ABA 4 - Automatic Flash-Point Tester, Abel Method (air cooled) Like 12-0501 but: Power supply: 115/230 V, 50/60 Hz, US-plug 12-0503 / 107098 ABA 4 - Automatic Flash-Point Tester, Abel Method (liquid cooled) Abel Method: ISO 13 736 (NF M07-011) - IP 170 (BS 3442-2) Equilibrium Method: ASTM D 3941 - ISO 1523 - IP 492 (IP 304-1) - EN 924 Equilibrium Method (flash/ no flash): ASTM D 3934 - ISO 1516 - IP 491 (IP 304-2) with further accessories for: Abel-Pensky Method: DIN 51 755-1 - NF M07-036 (DIN 53 213) see 12-0501 (air cooled), but with cooler connections for external liquid cooling. Software (Windows ): see 12-0501 (air cooled) Supplied with: see 12-0501 (air cooled) Note: Circulation cooler (e.g. 25-0382) is required. Temperature Range: -30 to +110 C (-22 to +230 F) Power supply : 230 V, 50/60 Hz, EU-plug 12-0504 / 108320 ABA 4 - Automatic Flash-Point Tester, Abel Method (liquid cooled) Like 12-0503 but: Power supply : 115 V, 60 Hz, US-plug Page: 3

Options & Accessories 25-0382 / 106535 Circulation Cooler (-20/+40) with insulated hose set For cooling of instruments without circulation pump (external tempering). Economical solution for cooling without tap water. Cooler with tank, Pt-100, digital display, pump and liquid level indication. Supplied with: 1 insulated hose-set (Ø 8 mm, 2x 2m) Technical Data: Working range: -20 to +40 C (+5 to +32 C at ambient temp.) Display / Resolution: digital / 0.1 C Cooling capacity: 300 W at +15 C Pump-Pressure capacity: 10 l/min, 200 mbar Pump-Suction capacity: 17 l/min, 180 mbar Volume: 1.4 l Sockets for: hose (Ø 8 /12 mm) Dimensions / Weight: 23 x 36 x 38 cm (WxDxH), 23 kg Power supply: 230 V, 50/60 Hz, 2.8 A, EU-plug 25-0228 / Hose-Set (Ø 8 mm) insulated, 2 x 2 m, incl. fittings 12-0518 / 106247 Insulating Hood - ABA/TAG to protect the cover and shutter assembly from icing. Recommended for low temperature flash-point tests, made of Styrofoam. 12-0520 / 107191 Calibration Set - ABA 1 calibration cover, 1 thermometer IP 74C, 1 thermometer IP 2C 12-1760 / 107247 Holding Device for Multi-Detector (PMA & ABA/TAG) suitable for: - calibration services: to calibrate the Pt-100 - customers: to check the functionality of Pt-100 & thermocouple requires: laboratory stand (e.g. 50-5001, 50-5013, 50-5031) and multi-meter (Ohm & mv) 25-0282 / 109446 Impact Printer (mono) for single sheets & continuous paper to record data like test results, duration of test, etc. (instead of a PC) Supplied with: 2 data cables (9-pin 25-0304, USB 25-0918), 1 ink ribbon (black) Technical Data: Line spacing: 80 characters per line (10 cpi) Page size : 257 x 364 mm (sheet), 254 x 558.8 mm (roll) Ports: serial (9-pin), USB (1.1) Dimensions: 37 x 28 x 16 cm (WxDxH) Weight: 5 kg Power supply: 220/240 V, 50/60 Hz 11-0599 / 106749 USB/RS232-Converter (verified for Petrotest units) with 2 m cable connecting 1 serial port with the USB-port of a PC or Hub 12-0574 / 107200 Milli Cover - pab, with shutter assembly Note! Flash-point results of milli test inserts may deviate from standard results. 12-0575 / 107201 Milli Cup - pab for sample quantity between 2... 15 ml, ideal 7 ml Page: 4

12-0577 / 107202 Multi-Detector - pab/pta for milli-tests or rapidflash-tests, with flash-point detector and temperature probe 12-1512 / 107238 Cover - ABEL-PENSKY, for older AP standards with shutter assembly (without a stirrer) fits Standard Cup "ABA" and Standard Multi-Detector "ABA" 12-0510 / 107185 Standard Test Insert - ABA (incl. in ABA 4) 1 cup and 1 cover, 1 multi-detector 12-2513 / Standard Multi-Detector - ABA, with DKD-certificate Like 12-0513 but: with officially certified values at -35 / 0 / +35 / +70 C 12-5793 / 108323 Handle for permanent fixing at a ABEL or PENSKY-MARTENS cup 12-1509 / Stand to hold 12 multi-detectors 12-5508 / Draft Deflector 5, transparent (recommended for gas ignition tests) Spare Parts 12-0511 / 107186 Standard Cup - ABA, 79 ml 12-0512 / 107187 Standard Cover - ABA, with shutter assembly 12-0513 / 107188 Standard Multi-Detector - ABA with flash-point detector (thermocouple) and temperature probe 12-0778 / 107206 Electric Igniter with connector cable and plugs 12-0509 / 107184 Gas Igniter with 25 cm hose 12-0514 / 107189 Safety Detector to control gas igniter and external inflammation 12-5600 / 109327 Tray to hold cup, multi-detector or ignitor 12-0790 / 107218 Tong for test cups without handle safe handling of hot test inserts 12-1507 / 107237 Stirrer Couplings, pack of 10 12-0791 / 107219 Stopper, brass (Ø 18 mm) to close the thermometer or multi-detector opening of the cover before use Order Guideline Minimum equipment: 1x 12-0501 or 1x 12-0503, 1x 25-0382, 1x 25-0228 Spares (approx. 1 year): 1 each: 12-0778, 12-0513, 12-1507 Additional requirements: gas supply, PC recommended Page: 5