Flow Measurement SITRANS F M

Similar documents
SITRANS F M. Transmitter MAG 5000/6000 4/33

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Flow Measurement SITRANS F M

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement RF Capacitance switches

Capacitance Level Measurement Electronic insert FEC 12

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Level Measurement Continuous level measurement - Capacitance transmitters

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Process Transmitter RMA 422

TFRN Industrial RTD temperature sensor. CombiTemp TM

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/224 Siemens FI Overview.

Wall-/Pipe-Mount Level Indicator

Process transmitter RMA422

TFRN Industrial RTD temperature sensor. CombiTemp TM

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Level Measurement. Continuous level measurement Radar transmitters. SITRANS LR250 Flanged Encapsulated Antenna. 4/228 Siemens FI

Dissolved Oxygen Transmitter

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

TFR5 Room or outdoor temperature sensor. CombiTemp TM

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

Dissolved Oxygen Transmitter

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Pendant Light Fitting IEC Series 6470/2

Inductive sensor NI3-EG08K-Y1-H1341

Nessie Coils for VDH and VDHT valves

Modular Lube Lubrication Systems System Controls

Inductive sensor BI1.5-EG08K-Y1

Fibre Optic Modem ODW-611

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331i / DMP 333i LMP 331 i

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

DATA SHEET Panorama Rudder Indicator, TRI-2

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Level Measurement Continuous level measurement Radar transmitters

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Absolute Encoders Multiturn

DATA SHEET ML210 ML210_IT_EN_DS017REV12_IS

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement silometer FMC 420, FMC 423

Level Measurement Continuous level measurement - Radar transmitters

Mechanical flow switch for On/Off control

Sensor technologies Proximity sensors Series ST4. Brochure

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

AF-300 E11 Adjustable Frequency Drive

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Single Point Flow Monitor SW118 SW119

FLOMAT Electromagnetic Insertion Flowmeter

Generator protection relay

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Fibre Optic Modem ODW-622

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Level Measurement Continuous level measurement Radar transmitters

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

ODW-621. RS-232 Point-to-point applications

LAUREL ELECTRONICS, INC.

Horn loudspeaker, Ex proof, short/long flare

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor NI10-M18-Y1X-H1141

Fibre optic router for TP/FT-10 LRW-112PP

SQM40/41 Actuators for air and gas dampers

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

ABB. Measure IT Uvisor System MFD Multi Flame Detector - Control Unit. Product Data Sheet (Rev. C)

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

PROPORTIONAL VALVES Sentronic plus

02/11/2015

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

LD OEM/LD PDS/LD PeCo

RMA42. Technical Information

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Multifunction devices

ELE C TRO MAG N E T I C FLO W M E T E RS

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Photoelectrics Through-beam Type PA18C.T..., DC

Liquid Level Sensor Type AKS 4100U

Coils for solenoid valves

IMPAC Infrared Thermometers

Magnecraft Power Relays

Datasheet - SRB301LC 24VAC/DC

TUC: Universal thermostat

Transcription:

Overview Design The transmitter is designed as either IP67 NEMA 4X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP20/NEMA 1 (prepared for IP65/NEMA 2 display side) Back of panel mounting IP20/NEMA 1 Wall mounting IP66/NEMA 4X Several options on 19 versions are available such as: Transmitters mounted in safe area for Ex ATEX approved flow sensors (incl. barriers) Transmitters with electrode cleaning unit on request compact version (left) and 19 insert version (right) The MAG 5000 and 6000 are transmitters engineered for high performance, easy installation, commissioning and maintenance. The transmitters evaluate the signals from the sensors type MAG 1100, MAG 1100 F, MAG 100, MAG 100 P and MAG 5100 W. Transmitter types: MAG 5000: Max. measuring error 0.4 % 1 mm/s (incl. sensor) MAG 6000: Max. measuring error 0.2 % 1 mm/s (incl. sensor, see also sensor specifications) and with additional features such as: "plug & play" add-on bus modules; integrated batch functions. Benefits Superior signal resolution for optimum turn down ratio Digital signal processing with many possibilities Automatic reading of SENSORPROM data for easy commissioning User configurable operation menu with password protection. lines, 20 characters display in 11 languages. Flow rate in various units Totalizer for forward, reverse and net flow as well as additional information available Multiple functional outputs for process control, minimum configuration with analogue, pulse/frequency and relay output (status, flow direction, limits) Comprehensive self-diagnostic for error indication and error logging (see under diagnostics) Batch control (MAG 6000 only) Custody transfer approval: PTB, OIML R 117, OIML R 49, MI- 001, PTB K 7.2 and OE12/C 040 for chilled water MAG 6000 with add-on bus modules for HART, FOUNDATION Fieldbus H1, DeviceNet, Modbus RTU/RS 485, PROFIBUS PA and DP Application The flowmeters are suitable for measuring the flow of almost all electrically conductive liquids, pastes and slurries. The main applications can be found in: Water and waste water Chemical and pharmaceutical industries Food and beverage industries Power generation and utility Function The MAG 5000/6000 are transmitters with a build-in alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic sensors and also fulfil the task of a power supply unit which provides the magnet coils with a constant current. Further information on connection, mode of operation and installation can be found in the data sheets for the sensors. Displays and controls Operation of the transmitter can be carried out using: Control and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication PC/laptop and SIMATIC PDM software using PROFIBUS or Modbus communication Transmitter Operating and display panel HART communication Master HART- Communicator PROFIBUS DP PROFIBUS PA communication + Coupler with power supply Coupling module PC/ laptop RS 22 PROFIBUS PA... min. 20 Ω Transmitter with PROFIBUS PA interface T Bus term. Siemens FI 01 2016 /

Technical specifications Mode of operation and design Measuring principle Empty pipe Excitation frequency Electrode input impedance Input Digital input Activation time Current Output Current output Signal range Load Time constant Electromagnetic with pulsed constant field Detection of empty pipe (special cable required in remote mounted installation) Depend on sensor size > 1 x 10 14 11... 0 V DC, R i = 4.4 K 50 ms I 11 V DC = 2.5 ma, I 0 V DC = 7 ma 0... 20 ma or 4... 20 ma < 800 0.1 0 s, adjustable Digital output Frequency 0... 10 khz, 50 % duty cycle (uni/bidirectional) Pulse (active) 24 V DC, 0 ma, 1 K R i 10 K, short-circuitprotected (power supplied from flowmeter) Pulse (passive) 0 V DC, max. 110 ma, 200 R i 10 K (powered from connected equipment) Time constant 0.1 0 s, adjustable Relay output Time constant Load Low flow cut off Galvanic isolation Max. measuring error (incl. sensor and zero point) 1) MAG 5000 MAG 6000 Rated operation conditions Ambient temperature Operation Storage Mechanical load (vibration) Compact version Changeover relay, same as current output 42 V AC/2 A, 24 V DC/1 A 0... 9.9 % of maximum flow All inputs and outputs are galvanically isolated. 0.4 % 1 mm/s 0.2 % 1 mm/s Display version: -20... +60 C (-4... +140 F) Blind version: -20... +60 C (-4... +140 F) MI-001 version -25... +55 ºC (-1... +11 ºF) Custody transfer (CT) version -20... +50 ºC (-4... +122 ºF) -40... +70 C (-40... +158 F) 18... 1000 Hz,.17 g RMS, sinusoidal in all directions to IEC 68-2-6 19 insert 1... 800 Hz, 1 g, sinusoidal in all directions to IEC 68-2-6 Degree of protection Compact version IP67/NEMA 4X/6 to IEC 529 and DIN 40050 (1 mh 2 O 0 min.) 19 insert IP20/NEMA 1 to IEC 529 and DIN 40050 EMC performance IEC/EN 6126-1 (all environments) IEC/EN 6126-2-5 Display and keypad Totalizer Display Time constant Design Enclosure material Compact version 19" insert Back of panel Panel mounting Wall mounting Dimensions Compact version Two eight-digit counters for forward, net or reverse flow Background illumination with alphanumeric text, x 20 characters to indicate flow rate, totalized values, settings and faults; Reverse flow indicated by negative sign Time constant as current output time constant Fiber glass reinforced polyamide; stainless steel AISI 16/1.446 (IP65) Standard 19 insert of aluminum/steel (DIN 41494), width: 21 TE, height: HE IP20/NEMA 1; Aluminum IP20/NEMA 1 (prepared for IP65/NEMA 2 display side); ABS plastic IP66/NEMA 4X; ABS plastic See dimensional drawings 19 insert See dimensional drawings Weight Compact version 0.75 kg (2 lb) 19 insert See dimensional drawings Power supply 115... 20 V AC +10 % -15 %, 50... 60 Hz Power consumption Certificates and approvals Custody transfer approval (MAG 5000/6000 CT) 11... 0 V DC or 20 V AC: 17 VA 24 V AC: 9 VA, I N = 80 ma, I ST = 8 A (0 ms) 12 V DC: 11 W, I N = 920 ma, I ST = 4 A (250 ms) 24 V DC: 8.4 VA, I N = 50 ma, I ST = 4 A (10 ms) I ST = 4 A (250 ms): For solar panel please secure stable current supply CE, C-UL general purpose, C-tick; FM Class I, Div 2, CSA Class I, Div 2, CMC/CPA Cold water: MI-001, PTB/OIML R 49 (pattern approval DE/DK) Chilled water: PTB K 7.2; OE12/C 040 Other media than water (milk, beer etc.): PTB and DANAK OIML R 117 (pattern approval DE/DK) (MAG 6000 CT) Communication Standard MAG 5000 Without serial communication or HART as option MAG 6000 Prepared for client-mounted addon modules Optional (MAG 6000 only) HART, Modbus RTU/RS 485, FOUNDATION Fieldbus H1, DeviceNet, PROFIBUS PA, PROFIBUS DP as add-on modules MAG 5000/6000 CT No communication moduls approved 1) For detailed accuracy specifications, see page /22 /4 Siemens FI 01 2016

Safety barrier (e/ia) Application Ex approval For use with MAG 5000/6000 19 and MAG 1100 Ex ATEX/MAG 100 Ex ATEX MAG 1100 Ex [EEx e ia] IIB ATEX MAG 100 Ex [EEx e ia] IIC ATEX Cable parameter Group Capacity in F Inductance in mh Electrode IIC 4.1 80 Ambient temperature During operation During storage Enclosure IIB 45 87 IIA 45 87-20... +50 C (-4... +122 F) -20... +70 C (-4... +158 F) Material Standard 19 insert in aluminum/steel (DIN 41494) Width 21 TE (4.75 ) Height HE (5.25 ) Rating IP20 / NEMA 1 to EN 60529 Mechanical load 1 g, 1 800 Hz sinusoidal in all directions to EN 60068-2-6 Siemens FI 01 2016 /5

Selection and Ordering data Transmitter MAG 5000 Transmitter MAG 6000 Transmitter MAG 5000 Blind for compact and wall mounting; IP67/NEMA 4X/6, fibre glass reinforced polyamide 11... 0 V DC/ 7ME6910-1AA0-0AA0 115... 20 V AC, 50/60 Hz 7ME6910-1AA10-0AA0 Transmitter MAG 5000 Display for compact and wall mounting; IP67/NEMA 4X/6, fibre glass reinforced polyamide 11... 0 V DC/ 7ME6910-1AA0-1AA0 115... 20 V AC, 50/60 Hz 7ME6910-1AA10-1AA0 115... 20 V AC, 50/60 Hz, with HART Transmitter MAG 5000 CT for compact and wall mounting, approved for custody transfer (only with approval marks, no verification only a complete flowmeter can be verified, i.e. sensor together with the transmitter); IP67/NEMA 4X/6, fibre glass reinforced polyamide 11... 0 V DC/ 115... 20 V AC, 50/60 Hz Transmitter MAG 5000 for 19 rack and wall mounting 11... 0 V DC/ 7ME6910-1AA10-1BA0 7ME6910-1AA0-1AB0 7ME6910-1AA10-1AB0 7ME6910-2CA0-1AA0 115... 20 V AC, 50/60 Hz 7ME6910-2CA10-1AA0 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Transmitter MAG 6000 Blind for compact and wall mounting; IP67/NEMA 4X/6, fibre glass reinforced polyamide 11... 0 V DC/ 1AA0-0AA0 115... 20 V AC, 50/60 Hz 1AA10-0AA0 Transmitter MAG 6000 for compact and wall mounting; IP67/NEMA 4X/6, fibre glass reinforced polyamide 11... 0 V DC/ 1AA0-1AA0 115... 20 V AC, 50/60 Hz 1AA10-1AA0 11... 0 V DC/ 115... 20 V AC, 50/60 Hz Transmitter MAG 6000 CT for compact and wall mounting, approved for custody transfer, without verification (no approval marks - only a complete flowmeter can be verified, i.e. sensor together with the transmitter); IP67/NEMA 4X/6, fibre glass reinforced polyamide 11... 0 V DC/ 115... 20 V AC, 50/60 Hz Spare part transmitter for CT systems produced before 04/2016 11... 0 V DC/ 115... 20 V AC, 50/60 Hz Transmitter MAG 6000 SV for compact and wall mounting; special excitation 44 Hz settings for Batch application DN 25/1 IP67/NEMA 4X/6, fibre glass reinforced polyamide 11... 0 V DC/ Transmitter MAG 6000 for compact and wall mounting; IP65/NEMA 4, stainless steel AISI 16/1.446 (only for sensor with SS terminal box) (for remote installation order SS terminal box separately) 1QA0-1AA0 1QA10-1AA0 1AA0-1AD0 1AA10-1AD0 1AA0-1AB0 1AA10-1AB0 1AB0-1AA0 115... 20 V AC, 50/60 Hz 1AB10-1AA0 Transmitter MAG 6000 for 19 rack and wall mounting 11... 0 V DC/ 2CA0-1AA0 115... 20 V AC, 50/60 Hz 2CA10-1AA0 /6 Siemens FI 01 2016

Transmitter MAG 6000 SV for 19 rack and wall mounting; special excitation 44 Hz settings for Batch application DN 25/1 11... 0 V DC/ 115... 20 V AC, 50/60 Hz MAG 6000 with IP66/NEMA 4X enclosure; 115... 20 V AC, 50/60 Hz; cable gland PG1.5 MAG 6000 with safety barrier for Ex-approved sensors, complete mounted with IP66/NEMA 4X wall mounting enclosure, ATEX, 115... 20 V AC, 50/60 Hz; cable gland PG1.5 For ATEX 2G D sensors MAG 6000 SV, 19 insert, in IP66/NEMA 4X, ABS plastic enclosure, excitation frequency 44 Hz for Batch application DN 25/1 ; cable gland PG1.5 11 0 V DC, 11 24 V AC, 50/60 Hz 115 20 V AC, 50/60 Hz 2CB0-1AA0 2CB10-1AA0 2EA10-1AA0 2MA11-1AA0 2EB0-1AA0 2EB10-1AA0 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Operating instructions for MAG 5000/6000 For MAG 5000/6000 IP67 German For MAG 5000/6000 19" This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Communication modules for MAG 6000 A5E02868 A5E02944982 A5E02082880 HART (not for MAG 6000 I) FDK:085U0226 Modbus RTU/RS 485 PROFIBUS PA Profile PROFIBUS DP Profile DeviceNet FOUNDATION Fieldbus H1 FDK:085U024 FDK:085U026 FDK:085U027 FDK:085U0229 A5E02054250 Operating instructions for SITRANS F add-on modules HART PROFIBUS PA/DP German Modbus German FOUNDATION Fieldbus German DeviceNet A5E0089708 A5E0072617 A5E01026429 A5E0075974 A5E0089262 A5E0218728 A5E02488856 A5E0089720 This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Accessories for MAG 5000 and MAG 6000 Accessory kit for remote use of sensor with two 5-pin terminal blocks Wall mounting unit for MAG 5000/6000 with IP67/ NEMA 4X/6 enclosure, wall bracket, terminal box in polyamide 1) 4 x M20 cable glands 4 x ½ NPT cable glands Sun lid for MAG 5000/6000 transmitter (Frame and lid) Cable for standard electrode or coil, x 1.5 mm² / 18 gage with shield PVC; Temperature range: -0... +70 C (-22... +158 F) 10 m ( ft) 20 m (65 ft) 40 m (10 ft) 60 m (200 ft) 100 m (0 ft) 150 m (500 ft) 200 m (650 ft) 500 m (1650 ft) A5E4827189 FDK:085U1018 FDK:085U105 A5E0228485 FDK:08F0121 FDK:08F0210 FDK:08F0211 FDK:08F0212 FDK:08F021 FDK:08F052 FDK:08F05 FDK:08F054 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. 1) For stainless steel wall mounting kit, order: - M20: FDK:085U1018 and A5E0086867 - ½ NPT: FDK:085U105 and A5E0086868 Siemens FI 01 2016 /7

Electrode cable for empty pipe or low conductivity 1), double shielded, x 0.25 mm². Temperature range : -0... +70 C (-22... +158 F) 10 m ( ft) 20 m (65 ft) 40 m (10 ft) 60 m (200 ft) 100 m (0 ft) 150 m (500 ft) 200 m (650 ft) 500 m (1650 ft) Low-noise electrode coax cable for low conductivity and high vibration levels of cables, x 0.1 mm 2 2 m (6.6 ft) 5 m (16.5 ft) 10 m ( ft) Cable kit with standard coil cable 1), x 1.5 mm²/18 gage with shield PVC and electrode cable double shielded, x 0.25 mm² Temperature range: -0... +70 C (-22... +158 F) 5 m (16.5 ft) 10 m ( ft) 15 m (49 ft) 20 m (65 ft) 25 m (82 ft) 0 m (98 ft) 40 m (10 ft) 50 m (164 ft) 60 m (200 ft) 100 m (0 ft) 150 m (500 ft) 200 m (650 ft) 500 m (1650 ft) Potting kit for terminal box of flow sensors for IP68/NEMA 6P FDK:08F020 FDK:08F095 FDK:08F094 FDK:08F09 FDK:08F092 FDK:08F056 FDK:08F057 FDK:08F058 A5E02272692 A5E0227272 A5E0227270 A5E0229629 A5E01181647 A5E02296464 A5E01181656 A5E02296490 A5E02296494 A5E01181686 A5E02296498 A5E01181689 A5E01181691 A5E01181699 A5E0118170 A5E01181705 FDK:085U0220 Back of panel mounting enclosure for 19 insert (21 TE); IP20/NEMA 1 enclosure in aluminum Back of panel mounting enclosure for 19 insert (42 TE); IP20/NEMA 1 enclosure in aluminum IP66/NEMA 4X, wall mounting enclosure for 19 inserts (without back plates). Use with PCB A5E0255981 or A5E02559814. Cable glands (FDK:08G0288) not included FDK:08F502 FDK:08F50 21 TE FDK:08F507 42 TE FDK:08F508 Front cover (7TE) for panel mounting enclosure Sun shield for remote MAG 5000/6000 transmitters Sun Shield for compact MAG 5000/6000 transmitters on MAG 100 (DN 15... 2000 (½"... 78") or MAG 5100 W (DN 150... 1200 (6"... 48") FDK:08F4525 A5E01209496 A5E01209500 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. 1) Special cables cannot be used with 19" safety barrier 19 safety barrier (21 TE) 1) [EEx e ia] IIC for MAG 1100 Ex sensors and MAG 100 Ex sensors 12... 24 V, 115... 20 V, incl. back plate (A5E02559810) Panel mounting enclosure for 19 insert (21 TE); IP65/NEMA 2 enclosure in ABS plastic for front panel mounting Panel mounting enclosure for 19 insert (42 TE); IP65/NEMA 2 enclosure in ABS plastic for front panel mounting FDK:08F504 FDK:08F500 FDK:08F501 /8 Siemens FI 01 2016

Spare parts Connection board (for polyamide terminalbox) Cable glands (polyamide), 4 pcs. 12... 24 V A5E02559817 M20 A5E00822490 115... 20 V Connection board (for stainless steel terminalbox) 12... 24 V 115... 20 V 19 enclosure, 12... 24 V, 115... 20 V Connection board for standard 19 transmitter A5E02559816 A5E02604280 A5E02604272 A5E02559809 ½ NPT PG 1.5, 2 pcs. Sealing screws for sensor/ transmitter, 2 pcs Terminal box, in polyamide, inclusive lid, terminal blocks, gasket and screws M20 ½" NPT A5E00822501 FDK:08G0228 FDK:085U0221 FDK:085U1050 FDK:085U1052 ½ NPT M20 Terminal box lid, in polyamide FDK:085U100 Connection board for transmitter ia and safety barrier Connection board for transmitter ia/ib and safety barrier (only for sensors produced before October 2007) Connection board for transmitter and cleaning unit SENSORPROM memory unit (Sensor code and serial numbers must be specified on order) 2 kb (for MAG 5000/6000/ MAG 6000 I) A5E02559810 A5E02559811 FDK:08F412-1 pc. FDK:085U1005-10 pcs. FDK:08F5052 250 B (for MAG 2500/000) Display unit for MAG 5000/6000 Black neutral front FDK:085U1008 FDK:085U108 Terminal box, in stainless steel, inclusive lid, terminal blocks, gasket and screws, for MAG 6000 in stainless steel and for all Ex sensors, M20 ½" NPT Terminal box (A) for MAG 1100 F in polyamide, inclusive lid, terminal blocks, gasket and screws M20 ½" NPT Spare part kit for remote use of sensor with 20 pcs. 5-pin terminal blocks Wall unit enclosure IP66, 12... 24 V, 115... 20 V PCB for standard transmitter A5E0086867 A5E0086868 A5E00822478 A5E00822479 A5E44687 A5E0255981 PCB for transmitter ia/e and safety barrier A5E02559814 Siemens front FDK:085U109 PCB for transmitter ia/ib and safety barrier (7ME610, 7ME6150 and 7ME60) A5E02559812 PCB for transmitter and cleaning unit A5E02559815 SENSORPROM programmer with RS 22 interface FDK:08H4246 HW key On request We can offer shorter delivery times for configurations designated with the Quick Ship Symbol. For details see page 9/5 in the appendix. Siemens FI 01 2016 /9

Dimensional drawings Transmitter IP67/NEMA 4X/6 compact polyamide 155 (6.10) 6 (0.24) 11 (5.16) 71 (2.80) 178 (7.01) Ø8 (0.1) Ø12 (0.47) Ø8 (0.1) 1 (0.51) 1 (0.51) 71 (2.80) 240 (9.45) 155 (6.10) 102 (4.02) 155 (6.10) 0 (1.18) 50 (2.0) 170 (6.70) Transmitter compact mounted, dimensions in mm (inch) Transmitter, 19 IP20/NEMA 1 standard unit Transmitter wall mounted, dimensions in mm (inch) 19 (7.60) 14 (0.6) 106 (4.17) 91 (.58) 175 (6.89) 168 (6.61) 128 (5.04) 122 (4.80) 2.8 (0.11) Weight incl. back print 0.8 kg (1.8 lbs) /40 Siemens FI 01 2016

Transmitter, wall mounting IP66/NEMA 4X, 21 TE 1 (0.51) 210 (8.27) 25 (9.25) 90 (.54) 120 (4.72) 146 (5.75) 90 (.54) 1 (0.51) 22 (0.86) 192 (7.56) Weight excl. transmitter: 2. kg (5.0 lbs) Transmitter, wall mounting IP66/NEMA 4X, 42 TE 1 (0.51) 90 (.54) 120 (4.72) 1 (0.51) 57 (14.05) 9 (1.5) Weight excl. transmitter: 2.9 kg (7.0 lbs) 22 (0.87) 90 (.54) 146 (5.75) 25 (9.25) Siemens FI 01 2016 /41

Transmitter, panel front IP20/NEMA 1, 21 TE 197 (7.75) 144 (5.67) 184 (7.24) 198 (7.80) 50 (1.97) 140 (5.51) Weight excl. transmitter: 1.2 kg (2.7 lbs) 185 (7.28) Transmitter, panel front IP20/NEMA 1, 42 TE 294 (1.57) 144 (5.67) 281 (1.06) 198 (7.80) 50 (1.97) 140 (5.51) Weight excl. transmitter: 1.6 kg (.5 lbs) 282 (1.10) /42 Siemens FI 01 2016

Transmitter, back of panel IP20/NEMA 1, 21 TE 16 (6.42) 144 (5.67) 117 (4.61) 218 (8.58) 12 (5.20) 57 (2.24) Weight: 0.7 kg (1.6 lbs) Transmitter, back of panel IP20/NEMA 1, 42 TE 269 (10.59) 25 (9.96) 22 (8.87) 218 (8.58) 12 (5.20) 57 (2.24) Weight: 0.9 kg (2.0 lbs) Siemens FI 01 2016 /4

Schematics Electrical connection Grounding PE must be connected due to safety class 1 power supply. Mechanical counters When mounting a mechanical counter to terminals 57 and 58 (active output), a 1000 µf capacitor must be connected to the terminals 56 and 58. Capacitor + is connected to terminal 56 and capacitor - to terminal 58. Output cables If the output cable length is long in noisy environment, we recommend to use shielded cable. Power supply Transmitter 115... 20 V AC L1 N Outputs 1 2 Passive output (External powered) 56 57 58 R Active output (Powered from transmitter) 56 57 58 Relay output 44 NO 45 NC 46 Common Digital input 77 78 L Current output (Powered from transmitter) R N PE 11... 0 V DC 11... 0 V DC/ Digital output Vx... 0 V max. 110 ma PLC-Digital input 24 V max. 0 ma Counter or PLC-Digital input Input 1 2 Relay 24 V DC/1 A 42 V AC/2 A PE 0/4-20 ma Load 800 Ω Menu setup Negative: Positive: R = Pull up/down resistor 1... 10 KΩ may be required - depending on Cables/Input resistance 91 92 9 94 95 96 97 Reserved for communication modules Sensor Sensor connection 1) 81 82 0 8 84 85 86 Electrode cable Coil cable 81 82 0 8 84 85 86 Shield 1) Note: Special cable with individual wire shields (shown as dotted lines) are only required when using empty pipe function or long cables. /44 Siemens FI 01 2016