Temposonics. Magnetostrictive Position Sensors. L Series (Model LH) to G-Series Linear-Position Sensor. Cross Reference A

Similar documents
Accessories EXTENSION CABLE OPTIONS - HOW TO ORDER. Standard 6-Pin connector type (D60) used with R-Series G-Series. Type DJ.

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

Highlights: Cables & Adaptors. Stock Cable Assemblies Custom Cable Assemblies Multi-conductor Cables Patch Panels Connector Adaptors

MOTION CONTROL SYSTEMS, MSC SERIES AUGUST 1998 EFC-240X ENCODER/FIBER OPTIC CONVERTER INSTRUCTION BOOK

Electromechanical Automation Applications Note

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

Agilent 11713A Attenuator/Switch Driver

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Absolute Linear Encoder

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

DMC550 Technical Reference

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm)

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

C-19-2 Microdot 100-Ω Miniature Cable with one BNC male plug and one microdot male plug; 0.61-m (2-ft) length.

4.9 BEAM BLANKING AND PULSING OPTIONS

GV 460 / GV 461 Impulse Splitters for Incremental Encoders with Potential Separation between Input and Outputs

TELEDYNE HASTINGS INSTRUMENTS

PT9150. Heavy Industrial Incremental Encoder

Cryostat Instrumentation Cabling Grounding and Shielding. Eric Hazen Boston University 12/15/08 1

HD-EXT2-C. HDMI over Shielded Twisted Pair Extender

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Revision 1.2d

Follow The Leader In Shielded Technology

canfield connector

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

Product Information. RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Linear encoders without bearings incremental System for linear motion feedback

Magnetic Sensor - Incremental EHP

MODEL LDL-C Miniature Non-Contacting Linear Encoder Kit

LD-V4300D DUAL STANDARD PLAYER. Industrial LaserDisc TM Player

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

DRAW WIRE SENSOR. Series LX. Key-Features:

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

Precision Linear Motor / Stepper Motor Stage Reference Manual (Open and Closed Loop Versions)

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Extra long-range RFID (proximity) card reader

16-BIT LOAD CELL/DUAL STATUS INPUT

WLC60 Heavy Duty LED Light - PWM Dimmable

Special Applications Modules

DL-AR2 Technical Specifications Universal HDMI Adapter Ring Rev

Type SCH94FO. Type SCH94FO. Description

Absolute Encoders Multiturn

Clamps, mounting plate EN :1993, 100 g/11 ms, 100 shocks EN :1995, 20 g 10 Hz-2 khz, 10 cycles

Advanced Test Equipment Rentals ATEC (2832)

DVB-LR10. Compatible with Land Rover touch-screen navigation systems version 2

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

Linear measuring technology

EZ Encoder : Optical Incremental

DX-10 tm Digital Interface User s Guide

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

EVALUATION KIT AVAILABLE 12.5Gbps Settable Receive Equalizer +2.5V +3.3V V CC1 V CC. 30in OF FR-4 STRIPLINE OR MICROSTRIP TRANSMISSION LINE SDI+ SDI-

Technical data. General specifications. Indicators/operating means

UC5 Cable Ordering Guide

Material: Weight: IP Rating: Cable: Connector:

TIL311 HEXADECIMAL DISPLAY WITH LOGIC

SCALE & WEIGHT DISPLAYS

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

Camera Setup Instructions

AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio

COPYRIGHT NOVEMBER-1998

User Manual. HDBaseT Receiver CMHDBTBRX. Front View Panduit Dr, Tinley Park, IL (708)

SignalTap Plus System Analyzer

Migatronic Tig - Plasma Welding machine /Fanuc robot Interface. Adapted for RJ3 Controller: Adapted for RJ2 Controller:

PROPORTIONAL VALVES Sentronic plus

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

MODEL ED32i TTL LINEAR ENCODER

Data Sheet. Electronic displays

Harmonica & Bassoon Digital Servo Drive Cable Kits

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

DataSAT ACU-2 Controller Wiring Configuration - Operation

4 x 4 VGA Matrix Switch

bmam connectors DIVIDER PAGE

Linear Array with Intensity Adjustment

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 65 MSPS DUAL ADC

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

LD OEM/LD PDS/LD PeCo

DVB-C25. Compatible with navigation systems Mercedes Benz Comand 2.5

INVISILED ACCESSORIES

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

Operating Instructions for Throttle Valves Using VRC Valve Positioner

Contact-Type Digital Displacement Sensor. HG-S Series. User's Manual WUME-HGS panasonic.net/id/pidsx/global

PT9232. Heavy Industrial RS232 Communication

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

DT1-LR10. Compatible with Land Rover touch-screen navigation systems version 2

Transcription:

Temposonics Magnetostrictive Position Sensors L Series (Model LH) to G-Series Linear-Position Sensor 550956 A Cross Reference Replacement and retrofit options for the L-Series Model LH sensor L-Series model LH number descriptors Sensor model A Flange type B Connection type C Integral cable length D Stroke length E Input voltage F Output L H T D 6 0 0 U # # # # 1 V 0 S M S # # M # # # # 2 A 0 M R B A 1 N R G A 2 B R 0 A 3 R 1 R 0 R 2 N 0 R 3 D I # # R M D E # # H 0 G-Series model number descriptors (Model LH retrofit options) Sensor model A Flange type B Stroke range C Connection type D Input voltage G H T # # # # U D 6 0 1 V # (C) S # # # # M R B # 2 A # (C) M F M # R 0 (#) B R # # N 0 (#) F # # D I # D E # 1. Many of the G-Series backwards compatible options as shown above are not included in other G-Series literature. 2. The characters (C) and (#) in parenthesis, as shown above, indicate model number characters that are not usually needed, and are used only for certain options. E Output type (Note 2) Contact MTS Applications Engineering for any model LH options that are not cross referenced in this document. All specifications are subject to change. Please contact MTS for specifications that are critical to your needs. Go to http://www.mtssensors.com/prodspec.htm for the latest list of G-Series support documentation.

A Flange Type (and hydraulic application housing) L H T G H T LH Model GH Description T T US cust. threads, raised-faced hex S S US cust. threads, flat-faced hex M M Metric threads, flat-faced hex N Not available Metric threads, raised-faced hex B B Sensor cartridge only (no hydraulic application housing) B Connection Type L H T R 0 0 5 G H T R 0 5 Reverse-acting outputs, please note: If the G-Series sensor is replacing an L-Series sensor, where the reverse-acting output, 10 to 0 Vdc, 20 to 4 ma or 20 to 0 ma is being used, then the wire connections must be changed at the controller. If an old or new D6 (D60) style extension cable will be used, reference the Wiring/Connections section of the G-Series User s Manual for the correct wiring at the controller. Otherwise, please reference the corresponding table and/or notes for the connection option chosen below. LH D6 RB RG MS R0 R1 or R2 R3 GH retrofit options Your LH has an integral D6 male connector. To retrofit, the GH model has the same option available: Select option D60 for integral 6-pin DIN male connector. Your LH has an integral RB male connector. To retrofit, the GH model has 3 options available: 1. Select option D60 for integral 6-pin DIN male connector, AND replace your complete extension cable (sold separately), or replace just the extension cable connector with the field-installed in-line 6-pin DIN female connector, part no. 370423, soldering required, (sold separately). See Table A on page 4. 2. Select option D60 for integral 6-pin DIN male connector, AND use the adapter cable part no. 253243-x or 253244-x, (sold separately). See Table B on page 4. (For reverse-acting outputs, see Note 2 under Table A.) 3. Select option RB# for integral cable with in-line RB male connector. Select RB1 for 1 foot integral cable length, (standard), or RB2 for 5 foot integral cable length. (For reverse-acting outputs, see Note 2 under Table A.) Your LH has an integral RG male connector. To retrofit, the GH model has 2 options available: 1. Select option D60 for integral 6-pin DIN male connector, AND replace your complete extension cable (sold separately), or replace just the extension cable connector with the field-installed in-line 6-pin DIN female connector, part no. 560700, soldering required, (sold separately). See Table C on page 4. 2. Select option D60 for integral 6-pin DIN male connector, AND use the adapter cable part number 253248-1 (1 foot) or 253248-2 (5 feet), (sold separately). (For reverse-acting outputs, see Note 1 under Table C on page 4). Your LH has an integral 10-pin MS male connector. To retrofit, the GH model has 3 options available: 1. Select option D60 for integral 6-pin DIN male connector, AND replace your complete extension cable (sold separately), or replace just the extension cable connector with the field-installed in-line 6-pin DIN female connector part number 560700, soldering required, (sold separately) See Table D on page 5. 2. Select option D60 for integral 6-pin DIN male connector, AND use the adapter cable part no. 253245-x, or 253246-x, (sold separately). See Table E on page 5. (For reverse-acting outputs, see Note 2 under Table D on page 5). 3. Select option FM# for integral cable (polyurethane jacket) with the in-line MS male connector. Select FM1 for 1 foot integral cable length, (standard), or FM2 for 5-foot integral cable length. (For reverse-acting outputs, see Note 2 under Table D on page 5.) Your LH has an integral cable, pigtail termination. To retrofit, the GH model has 1 option available: Select option R## for integral cable, pigtail termination, encode ## with the desired cable length (01 to 99 ft.) (For reverse-acting outputs, reference the Wiring/Connections section of the G-Series User s Manual for the correct wiring at the controller.). Your LH has an integral cable and an in-line 6-pin MS male connector. To retrofit, the GH model has 2 options available: 1. See Table F on page 5 or contact MTS Applications Engineering to see if you can connect the GH model sensor directly to your controller / interface card, and no longer use the Analog Output Module (AOM), or the Digital Interface Box (DIB) that is in your system. 2. If the AOM or DIB is still required in your system, select option D60 for integral 6-pin DIN male connector, AND use the adapter cable part no. 253302-1 (for R1) or 253302-2 (for R2), (sold separately). 3. If the AOM or DIB is still required in your system, select option R## for integral cable with pigtail termination, (encode ## for cable length), AND install an in-line 6-pin MS female connector, part no. 370015, soldering required, (sold separately). See Table G on page 6. Your LH has an integral cable and an in-line 10-pin MS male connector. To retrofit, the GH model has 3 options available: 1. Select option D60 for integral 6-pin DIN male connector, AND replace your complete extension cable (sold separately). 2. Select option D60 for integral 6-pin DIN male connector, AND use the adapter cable part no. 253245-3, (1 foot length), or 253246-3, (5 foot length), (sold separately). 3. Select option R## for integral cable with pigtail termination, (encode ## for cable length) AND install an in-line 10-pin MS male connector, part no. 370160, soldering required, (sold separately). See Table H on page 6. 2

C Integral cable length L H T R 0 0 5 G H T R 0 5 LH Model GH Description 01 to 99 ft. 01 to 99 ft. Cable length in feet 01 to 30 meters 01 to 30 meters Cable length in meters Encode length in feet if using US customary stroke length, in meters if using metric stroke length. D Stroke length L H T R 0 0 5 U 0 1 2 0 G H T 0 1 2 0 U R 0 5 LH GH Description U.. U Stroke length in inches and tenths, 2 to 300 in. (Encode in 0.1 in. increments) M M Stroke length in millimeters, 50 to 7620 mm. (Encode in 5 mm increments) E Input voltage L H T R 0 0 5 U 0 1 2 0 1 G H T 0 1 2 0 U R 0 5 1 2 1. Compared to the L-Series the input voltage options 1 and 2 have basically swapped values for the G-Series. (The G-Series follows the convention established by the E-Series and R-Series sensors.) 2. For the above example, when retrofitting LH sensors with stroke lengths < or = to 60 inches, the appropriate GH option ( 1 or 2 ) must be selected based on the customer s actual power supply used in the application. Option LH GH 1 +13.5 to 26.4 Vdc (For stroke lengths < or = 60 inches) +24 Vdc (+20%, -15%), standard 2 +24 Vdc (+10%, - 10%) (For stroke lengths > 60 inches) +9 to +23 Vdc F Output type L H T R 0 0 5 U 0 1 2 0 1 G H T 0 1 2 0 U R 0 5 1 2 LH GH Description Start/Stop R0 R0(#) Start/Stop output. If the sensor has more than one magnet, the (#) denotes the number of magnets in hexadecimal, (i.e. 2 - F). If the sensor has only one magnet, leave the (#) character in the model number blank. N0 N0(#) Start/Stop output wired for square wave neuter ( +Stop signal used for compatible neuter output pulse). If the sensor has more than one magnet, the (#) denotes number of magnets in hexadecimal, (i.e. 2 - F). If the sensor has only one magnet, leave the 15th character in the model number blank. Pulse-Width Modulated (PWM) D a b c D a b PWM output. The first character (a) indicates the type of interrogation, (E = external, I = internal), for both LH and the GH model. The other characters (b-c) for LH indicate the number of circulations. For the GH model encode this value, (now limited between 1 and 15), for the single character (b) using hexadecimal, (1 to F). Analog Voltage (format below is: Voltage [value at Null (Setpoint 1)] to [value at Span (Setpoint 2)] V0 V0 0 to +10 Vdc (If the 10 to 0 Vdc output is being used, select option V1. See note for reverse-acting outputs under section B, Connection Type.) A0 A0 4 to 20 ma A1 A1 20 to 4 ma (See note for reverse-acting outputs under section B, Connection Types.) A2 A2 0 to 20 ma A3 A3 20 to 0 ma (See note for reverse-acting outputs under section B, Connection Types.) C0 or CC suffix Non-standard output. Consult MTS Application Engineering. Usually signifies custom analog setpoints. 3

Tables Table A Wire color code for RB style extension cable Replace RB connector on extension cable by Installing 6-pin DIN female connector, part no. 370423 RB pin no. Wire colors Pin-out for Analog output Pin-out for Digital-Pulse output Pin-out for Neuter output only 1 White 6 6 6 2 Brown No Connection No Connection No Connection 3 Gray 2 1 1 (Note 1) 4 Pink 1 2 No Connection 5 Red 5 5 5 6 Blue No Connection No Connection No Connection 7 Black 3 (Note 2) No Connection No Connection (Note 3) 8 Violet 4 (Note 2) No Connection 2 9 Yellow No Connection 3 3 (Notes 4, 5) 10 Green No Connection 4 4 (Notes 4,5) 1. The G-Series output signal, (-) Stop, is not used when providing the backwards compatible neuter type connection. However, this signal wire / connector pin is used for RS-422 TX- during serial programming of the sensor. When the sensor output is active, (not in programming mode), this signal must be left unconnected to allow the proper neuter type output. 2. If the G-Series sensor is replacing a L-Series sensor where the reverse-acting output, 10 to 0 Vdc, is being used, then the wire connections must be changed at the controller. The black wire (RB pin 7) will now be used for Programming (RS-485+) by the G-Series sensor instead of the 10 to 0 Vdc reverse-acting output. Also, the violet wire (RB pin 8) will now be used for Programming (RS-485-) by the G-Series sensor instead of the return connection for the reverse-acting output. The input connections at the controller will now need to use the pink wire (RB pin 4) for the 10 to 0 Vdc sensor signal, and the gray wire (RB pin 3) for the output return connection. 3. If the black wire (RB pin 7) was originally used as DC ground for the L-Series sensor being replaced then the DC ground connection at the controller must be changed to use the white wire (RB pin 1). 4. When connecting to an Analog Output Module (AOM), or to a Digital Interface Box (DIB), or to a custom interface/controller that requires singleended interrogation, always connect the unused interrogation lead, (+) Start or (-) Start to ground at the AOM / DIB / controller. 5. For improved noise rejection and stable operation when using external interrogation use the positive and negative interrogation signals, (+) Start and (-) Start, to provide differential inputs to the sensor. Table B Female straight exit D6 to male RB connection adapter cables 1 ft. cable length, standard, for G-Series analog output sensors Part no. 253243-1 1 ft. cable length, standard, for G-Series digital-pulse and neuter output sensors Part no. 253243-2 5 ft. cable length, for G-Series analog output sensors Part no. 253244-1 5 ft. cable length, for G-Series digital-pulse and neuter output sensors Part no. 253244-2 For reverse-acting outputs, see Note 2 under Table A. Table C Wire color code for RG style extension cable Replace RG connector on extension cable by installing 6-pin DIN female connector, part no. 560700 RG pin no. Color Pin-out for Analog outputs and for Digital-pulse outputs 1 Gray 1 2 Pink 2 3 Yellow 3 (Note 1, 2, 3) 4 Green 4 (Note 1, 2, 3) 5 Red or Brown 5 6 White 6 7 No connection No connection 1. If the G-Series sensor is replacing a L-Series sensor where the reverse-acting output, 10 to 0 Vdc, 20 to 4 ma or 20 to 0 ma, is being used, then the wire connections must be changed at the controller. The yellow wire (RG pin 3) will now be used for Programming (RS-485+) by the G-Series sensor instead of the reverse-acting output. Also, the green wire (RG pin 4) will now be used for Programming (RS-485-) by the G-Series sensor instead of the return connection for the reverse-acting output. The input connections at the controller will now need to use the gray wire (RG pin 1) for the 10 to 0 Vdc, 20 to 4 ma or 20 to 0 ma sensor signal, and the pink wire (RG pin 2) for the output return connection. 2. When connecting to an interface/controller that requires single-ended interrogation, always connect the unused interrogation lead, (+) Start or (-) Start to ground at the controller. 3. For improved noise rejection and stable operation when using external interrogation use the positive and negative interrogation signals, (+) Start and (-) Start, to provide differential inputs to the sensor. 4

Tables continued Table D Wire color code for MS style extension cable (10-pin MS connector) Replace 10-pin MS connector on extension cable by installing 6-pin DIN female connector, part no. 560700 MS pin no. Color Pin-out for Analog output Pin-out for Digital-Pulse output A White 6 6 B No connection No connection No connection C Gray 2 1 D Pink 1 2 E Red 5 5 F No connection No connection No connection G & J (Note 1) Yellow 3 (Note 2) 3 (Notes 3, 4) H & K (Note 1) Green 4 (Note 2) 4 (Notes 3, 4) 1. The MS style extension cable is assembled with the yellow wire connected to pin G only, and the green wire connected to pin H only. However, pins G & J are connected together, and H & K are connected together via the interconnect board within the L-Series sensor model having the MS style connection. 2. If the G-Series sensor is replacing a L-Series sensor where the reverse-acting output, 10 to 0 Vdc, 20 to 4 ma or 20 to 0 ma, is being used, then the wire connections must be changed at the controller. The yellow wire (MS pin G) will now be used for Programming (RS-485+) by the G-Series sensor instead of the reverse-acting output. Also, the green wire (MS pin H) will now be used for Programming (RS-485-) by the G-Series sensor instead of the return connection for the reverse-acting output. The input connections at the controller will now need to use the pink wire (MS pin D) for the 10 to 0 Vdc, 20 to 4 ma or 20 to 0 ma sensor signal, and the gray wire (MS pin C) for the output return connection. 3. When connecting to an interface/controller that requires single-ended interrogation, always connect the unused interrogation lead, (+) Start or (-) Start to ground at the controller. 4. For improved noise rejection and stable operation when using external interrogation use the positive and negative interrogation signals, (+) Start and (-) Start, to provide differential inputs to the sensor. Table E Female straight exit D6 to male MS connection adapter cables 1 ft. cable length, standard, for G-Series analog output sensors Part no. 253245-1 1 ft. cable length, standard, for G-Series digital-pulse sensors Part no. 253245-2 5 ft. cable length, for G-Series analog output sensors Part no. 253246-1 5 ft. cable length, for G-Series digital-pulse sensors Part no. 253246-2 For reverse-acting outputs, see Note 2 under Table D. Table F If your system has an Analog Output Module (AOM) You can connect the GH model sensor directly to your controller/interface card (bypassing the AOM) if: 1. The AOM output is displacement only (voltage or current). 2. There is no velocity output from the AOM. 3. There are no dual channel outputs from the AOM. 4. There are no external null or scale adjustment potentiometer inputs to the AOM. If your system has a Digital Interface Box (DIB) You can connect the GH model sensor directly to your controller/interface card (bypassing the DIB) if: The DIB is configured to use 15 or less recirculations. Contact MTS Applications Engineering for the appropriate retrofit GH model number, or if you have questions. Contact MTS Applications Engineering for the appropriate retrofit GH model number, or if you have questions. 5

Tables continued Table G GH Model Installing 6-pin MS female connector, part no. 370015, onto GH model sensor with integral cable Integral Wire Color Code Output for Square Wave Neuter (Using +Stop ) For R1 connection type: (positive interrogation) For R2 connection type: (negative interrogation) Gray (-) Stop No Connection (note 1) No Connection (note 1) Pink (+) Stop (Compatible Neuter Output Pulse) C C Yellow (+) Start E B (note 2) Green (-) Start B (note 2) E Red or Brown Supply Voltage (+Vdc) F F White DC Ground (for supply) B B 1. The G-Series output signal, (-) Stop, is not used when providing the backwards-compatible neuter type connection. However, this signal wire is required for RS-422 TX during serial programming of the sensor. Pin A of the 370015 connector can not be used for this signal since the Analog Output Module (AOM), or the Digital Interface Box (DIB), provides +12 to +14.5 volts output on this pin when connected. Upon installing the 370015 connector the gray wire must be left disconnected, and the serial programming feature of the sensor is no longer available. 2. When connecting to an AOM, or to a DIB, or to a custom interface/controller that requires single-ended interrogation, always connect the unused interrogation lead to ground at the AOM/DIB/Controller. Table H GH Model Installing 10-pin MS male connector, part no. 370160 (for R3 connection type only), onto the GH model sensor with integral cable Integral Wire Color Code Digital pulse Output Pin No. Gray (-) Gate for PWM (-) Stop for Start/Stop K Pink (+) Gate for PWM (+) Stop for Start/Stop G Yellow (+) Interrogation for PWM (note 1) (+) Start for Start/Stop E (See Note below) Green (-) Interrogation for PWM (note 1) (-) Start for Start/Stop D (See Note below) Red or Brown Supply Voltage (+Vdc) H White DC Ground (for supply) A For improved noise rejection and stable operation when using external interrogation, use the positive and negative interrogation signals, (+) Start and (-) Start, to provide differential inputs to the sensor. Part Number: 04-05 550956 Revision A Temposonics is a registered trademark of MTS Systems Corporation. All other trademarks are the property of their respective owners. All Temposonics sensors are covered by US patent number 5,545,984. Additional patents are pending. Printed in USA. Copyright 2005 MTS Systems Corporation. All Rights Reserved.