SOFT LED 4 Vari-White INSTRUCTION MANUAL

Similar documents
SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

INSTRUCTION MANUAL 1. INTRODUCTION

BROTHER, BROTHER & SONS

BROTHER, BROTHER & SONS

SUPER LED F6 120W LED Fresnel SPOTLIGHT 100/120V or 230/240V 50/60 Hz (white light, either Tungsten or Daylight balanced Correlated Color Temperature)

S30-RP LED Soft Light

LEDONARDO 2 USER MANUAL. BROTHER, BROTHER & SONS ApS

S30-C LED Soft Light LIGHTING - PRODUCT SPECIFICATION V1.0

L5-C LED Fresnel L I G H T I N G - P R O D U C T S P E C I F I C A T I O N V2.2

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

LED Thunder S-150 Code 1097

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc..

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Mini LED Pin Spot Light Model: PLS00571

DMX LED light effect with 4 lenses

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

Yoke Safety cable loop. Up Light Bulb

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

ETC Quick Guide. Source Four LED Profile

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

2X2 Panel. 1X2 Panel

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

PRODUCT SPECIFICATIONS

Stratos Duo RGB. User Manual. Order code: EQLED371

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

Spectra Batten (Order code: LEDJ95)

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE April 2014 version

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

9X9W LEDS BLINDER WITH LCD DISPLAY USER GUIDE December 2013 Version 1.12

The features shown in the following graphics may not appear on all Desire Series fixtures. LCD Power In DMX In

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7

Ref. No.: LCB-48IP LED COLORUNIT 16X3W TRI DMX

6X3W TRICOLOUR LEDS COMPACT PROJECTOR

Octagon Theater CW/WW/A 20 6W LED PAR. user manual

PRO PAR HEX 12. User Manual

Color mixing or White-light LED (Light Emitting Diode) ERS-style product

LED Spot 300W. Please read this user manual before your operation

TABLE OF CONTENTS PART 5 APPENDIX TROUBLE SHOOTING MAINTENANCE A CTIVATE THE PASSWORD...13.

2x2 DUAL COLOR LED SOFTLIGHT

192 Channel DMX Controller

Led Dynamic DMX Tri Curtain Manual

SHOWLINE SL PAR 155 LED LUMINAIRE SPECIFICATIONS.

JunoScan MK-II LED scanner. user manual

1440/2880 HP RGB+WW+CW

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

180w led gobo moving USER MANUAL

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS

Fusion 120 Zoom. User Manual. Order code: EQLED068

SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS.

Chroma-Q Studio One 100 D

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

Sirio 150 / 150DV. Code 02E010 - Sirio 150 Code 02E011 - Sirio 150DV OPERATING INSTRUCTIONS. COEF srl. Revision 1

MH-X50+ LED spot moving head. user manual

LED-PAR200B USER MANUAL. COLORsplash 200B

Altman Lighting AP-150 RGBW Par Specification

LED MOVING HEAD LedWash. 36 x 10w RGBW 4in1 Zooming USER MANUAL. Version 1.0 beta

SquareLED - Aura Bar & Matrix Beam Light 100

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

aorun manual V2.0 MARCH 2018

LED-BANK4 USER MANUAL. COLORbank 4

ORDER CODE: EQLED65 USER MANUAL

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating

Quick Reference Guide

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

Tube Rotator. User Guide. Version 1.2

Liner Quattro AC XB RGBW

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Nila light fixtures are intended for indoor use only (unless clearly specified for outdoor use).

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

Installation and Operation Manual Next Generation On-Camera Prompter Displays

Ilumipanel 36X3 IP Optic RGB

RevEAL CW with TrueSource Technology Operating Manual

LED Pot 12 1W RGBW LED PAR. user manual

www. eklights.com Guangzhou Liangyi Lighting Equipments Co.,Ltd. 37 Gongyedadao, Xinhua, Huadu, Guangzhou PC:510800

USER GUIDE IRLEDS SERIES - LED PAR PROJECTORS WITH INFRARED REMOTE CONTROL

SHOWLINE SL BEAM 100 LED LUMINAIRE SPECIFICATIONS.

LCB-320 LED COLORS 320X10MM DMX 16SEG

Altman Lighting Spectra Cyc 50 Specification

CHALICE PENDANT LED DOWNLIGHT 70 Watt LED

Hex-color RGBAW+UV LED strip light

CHALICE PENDANT LED DOWNLIGHT 150 Watt LED

Snapshot. Kinta X USER MANUAL

LEDWash RGBW USER MANUAL

User Manual MAINTENANCE AND CLEANING. CAUTION Disconnect from mains before starting maintenance operation. KEEP THIS MANUAL FOR FUTURE NEEDS

LED IP65 Slimline Par RGBWA +UV 7x12W

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

sequenza 1000/1250 al manuale di istruzioni instruction manual 1^ edizione, ottobre st edition october 1996

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT

Transcription:

SOFT LED 4 Vari-White 180W LED SOFTLIGHT 90-250V 50/60 Hz (white light, with tunable correlated color temperature from 2.800 to 6.600 K) INSTRUCTION MANUAL Manual Operated (Pole Operated available, not shown) REPRESENTATIVE MANUFACTURER ILT Italy S.r.l. Via Cancelliera # 10a, 00041 Albano Laziale (Rome- Italy). Tel. +39/06/902901 Fax. +39/06/90231051 U.R.L.: E-mail: desisti@desisti.it 1. INTRODUCTION Congratulations on your purchase of a SOFT LED 4 Vari-White lighting fixture. Our commitment to Total Customer Satisfaction and our consolidated experience and leadership in design innovation and manufacturing of lighting products for the professional Entertainment Industry means you can depend upon the quality of this product. The SOFT LED 4 Vari-White is a innovative 360W LED SOFTLIGHT, with a COLOR RENDERING INDEX CR higher than 95 at any CCT within a range, from a minimum of 2.800 K to a maximum of 6.600 K; it provides a smooth and soft shadow projecting beam, yet within a controlled field that makes it ideal for multiple camera set ups. The Lighting Fixture is DMX Controlled and includes a number of parameters that can be set locally, it is equipped with either a 90-250V 50/60Hz power supply for AC feed and the front Remote Phosphors Panel is easily interchangeable and it is available with either Tungsten or Daylight Balanced CCT. Standard accessories are available such as Black or White Honeycombs with either narrow or medium cells for different beam shaping and control, Colour Frame, Beam Intensifier and a special yoke for multiple fixtures configuration, for background lighting applications.

2. YOKE AND ACCESSORIES ASSEMBLY

3. POWER AND DMX DAISY CHAIN The SOFT LED permits both POWER and DMX DAISY CHAIN. In fact each Fixture is respectively equipped with: For DMX: 1 XLR5 pin Panel Mount Male (DMX IN) 1 XLR5 pin Panel Mount Female (DMX OUT) For Mains Supply 1 20A Powercon NAC3MPA BLUE (POWER IN) 1 20A Powercon NAC3MPB WHITE (POWER OUT) It is recommended to Daisy Chain a Max of 10 fixtures, even if the limitations imposed by DMX Standards are for an higher q.ty of units and even if the Powercon Connections are rated for 20A max. 4. SAFETY INSTRUCTIONS Professional use: This luminaire has been designed for professional use and must be operated by qualified personnel only. Not for residential use. Grounding: WARNING: THIS LUMINAIRE MUST BE GROUNDED WARNING: Disconnect Power CORDS before any maintenance work or opening the FUSE HOLDER. Risk of serious injury. Electrical connections: IMPORTANT The cores in this mains lead are colored in accordance with the following code: Europe America Ground Green & yellow Green or green & yellow Neutral Blue White Live Brown Black In case the colors of the cores do not correspond to the colors of the connection points on your plug, please proceed as follows: the green or green and yellow core must be connected to the connection point marked with the letter E or with the symbol in green or in green - yellow; the blue (or white) core must be connected to the connection point marked with the letter N or colored in black; the brown (or black) core must be connected to the connection point marked with the letter L or colored in red. or colored Working Position Lighting fixture: Max. Tilting ±90 from horizontal Ambient Temperature, t a at the place of installation and Storage Humidity at the place of installation and Storage Minimum distances from inflammable surfaces Minimum 10 C, maximum +40 C 25-80% (not condensing) Top Back Sides Front 0,2 m. 0,1 m. 0,1 m. 0,75 m.

The luminaire should never be OPERATED close to inflammable materials. The ones indicated in the above table are the minimum distances recommended. Other requirements for safe use are: A. Do not cover the apertures of the luminaire housing. They are essential for correct ventilation. B. Use only original accessories and spares from De Sisti Lighting. C. Before hanging the luminaire ensure that the suspension point (or the stand) is properly rated to accept the luminaire weight. D. In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting. E. A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between the suspension point and the eyelet at the front of the body F. WARNING : DO NOT MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE 5. INSTALLATION INSTRUCTIONS The following procedure should be adopted: Before connecting the luminaire to the electrical mains ensure that: A. Earth line is present on the power socket. B. The mains voltage is within the rated range of the luminaire (see technical data on the rating label) C. The front safety Shield is present and in good condition. It consists of a Remote Phosphors Panel 305 x 107 mm. WARNINGS : Do not operate the product if the ambient temperature exceeds 40 C Provide a minimum clearance of 0,1m (4 in.) around fans and air vents. SHIELDS, LENSES SAFETY OR DICHROIC GLASSES SHALL BE CHANGED IF THEY HAVE BECOME VISIBLY DAMAGED TO SUCH AN EXTENT THAT THEIR EFFECTIVENESS IS IMPAIRED, FOR EXAMPLE BY CRACKS OR DEEP SCRATCHES. THE LUMINAIRE SHALL ONLY BE USED COMPLETE WITH ITS PROTECTIVE SHIELD D. Applying power: Never connect to dimmer power. Install a power plug on the power cable using the following pin assigment: 1 : Neutral 2 : Live Green/Yellow : Ground - This fixture must be connected to ground. Make sure the local power voltage is within the range specified. If so; connect the power cable and turn the power on. E. Stand Alone operation: Using the navigation buttons and display readout ( refer to the Local Menu chapter ) navigate to Manual and set the desired intensity (for additional operations see Local Menu chapter) F. DMX operation: Connect a DMX cable Navigate to Address mode (Addr) and set the desired address, (refer to the Local Menu chapter). Connect to DMX controller (refer to the Channel Setting in the Local Menu chapter) and Use it. 6. LOCAL MENU The SOFT LED4 Vari-White has a GRAPHIC DISPLAY backlit, with two local knobs, each one having a push/click function in addition to the rotation:

KNOB 1 It is as a DEFAULT the CCT Variation Knob, By rotating it clockwise the CCT Changes from 2.750 K up to 6.900 K. If such a knob is kept pushed, it provides a FAST ACTION on the KNOB 2 which is normally the DIMMING Display It is a Graphic, backlit LCD Display. It contains all the relevant information for the product setup and performances, such as CCT, DMX Address, DMX Level, LED Temperature and local dimming. When the local knobs are not used for more than 5 seconds the display back illumination will go OFF and the display itself will go in STAND BY Mode. It will go ON again anytime a KNOB is activated. KNOB 2 It is as a DEFAULT the DIMMING Variation Knob, By rotating it clockwise the Dimming of the Light Changes from 0utput to Full Light Output. If such a knob is pushed, it has the selection or enter function to, for instance, enter into a Menu DEFAULT SETTINGS ARE INDICATED IN BOLD LETTERS ON THE FOLLOWING TABLE: The following are the BASIC FUNCTIONS and COMMANDS that are provided on the LOCAL MENU of the SoftLED. The unit is provided with a USER MENU accessible instantly on the product. 1st menu displayed 2nd menu displayed Explanation of each menu function DMX ADDRESS This Function is to SET the DMX address from 1 to 512 The Product is delivered with a default setting of the DMX address at 1. As indicated next to each picture, it is required to reach the DMX addr Menu, select the preferred base DMX Address and Select it. Once the DMX Address is SET, in order to return to the MAIN MENU, it is necessary to rotate KNOB 2 counter-clock-wise to return to the EXIT item and then select it by pressing KNOB 2 itself.

CHANNEL SETTING (RESOLUTION & FUNCTION) This function is to SET THE DIMMING RESOLUTION either at 8 bits or at 16 bits. Select DMX resol by rotating and pushing KNOB2, the following choices are available: - 8 bits resolution (the display will show 8 bit). The fixture utilizes 1 DMX Circuit for the Light Dimming, which is the BASE CIRCUIT set in the ADDRESS. - 16 bits: 16 bits resolution (the disply will show 16 bit and this is the default setting). The fixture utilizes 2 DMX Circuits: The Base Circuit set in the address is the Coarse Dimming, the second Circuit (Base +1) is the Fine Dimming. Of course the benefit of the 16 bits function the corresponding circuits on the DMX Lighting Board shall also beset at 16 bits. LOCAL DIMMING CONTROL This function is to LOCALLY DIM THE LED INTENSITY from 0 to 100% (Product is delivered with default setting of the Dimmer at 0) he right knob is doing the dimming action and it goes with a fine tuning in normal condition, or a fast dimming when rotating KNOB 2 while keeping KNOB 1 pressed in. LOCAL CORRELATED COLOUR TEMPERATURE CONTROL This Function is to LOCALLY ADJUST the CORRELATED COLOUR TEMPERATURE from 2.800 K to 6.600 K (Product is delivered with d efault setting of the CCT at 2.800 K). The rotation of KNOB 1 will determine CCT increments according to the following table (STEP MODE). If a continuous CCT adjustment is required (LINEAR MODE) it is necessary to operate through a DMX Console: please see DMX parameters above. local dimming setting will be maintained and will be automatically recalled after power off, when LOCAL OR REMOTE CONTROL SETTINGS The LED Fresnel has the facility to block the LOCAL DIMMING and CCT SETTING and maintain it when the Power is turned first OFF and then ON again. This allows for the Light to be tuned and focused locally and its dimming plus CCT level can be blocked, so tghat for instance a system lighting a Set can be operated by a remote switch or simple brackers by turning POWER ON. The machine is set to Auto save OFF as default: in this condition the Fixture can be controlled locally until a DMX device is connected to it. Once the Console will be acting it will take priority over any local control. To turn the Autosave ON please follow these instructions: - rotate KNOB 2 and select Auto save OFF - press KNOB 2 to highlight the status of Auto save, in this case OFF - rotate KNOB 2 to turn the status od Auto save to ON and press it - leave the setting in this condition: the light will ignore any DMX control In this code any local dimming setting will be maintained and will

INFORMATION PROVIDED ON THE DISPLAY Display of Correlated Colour Temperature Display of LED Case TEMPERATURE Display of DMX Leve DMX Address Display of local potentiometer level (when in local control or turned off turned DMX controller) Graphic Scale of Dimming 7. CHARACTERISTICS AND PERFORMANCE DATA DESCRIPTION VALUE DESCRIPTION VALUE LED Power 180 W Protection Type IP 22 Power Consumption DMX Data link USITT DMX512-A DMX Channels: 200W @230V / 205W @ 120V Max Housing temperature 70 C 5-pin XLR for DMX in & out. Use shielded data cables. Do not overload the daisy chain. Up to a maximum of 32 devices can be used on a single DMX chain. 1 at 8bit: Dimmer 2 at 16bit: Dimmer Protection Class Class 1 ground connection required Weight of Fixture With yoke (integrated PSU) Color Temperature & CRI/TLCI of Diffuser Panels Front Fixture s Opening M.O. P.O. 5,5 kg. 6,7 kg. CRI>95 TLCI >96 2800 K from 6600 K Front 27,5 cm.(base) x 20,7cm. (height) = surface 569 cm 2 Specifications subject to change without notice.

8. DIMENSIONS Dimensions: Black=mm. Red=inches Dimensions: Black=mm. Red=inches 9. PERIODIC INSPECTION & MAINTENANCE This product requires very little routine maintenance, if any, but has special cleaning instructions: Disconnect fixture from power and allow it to cool for 10 min. 1. Vacuum or gently blow away any dust from fan blades and grills 2. Very gently clean the LED with Isopropyl alcohol. 3. Clean the Diffuser Panel with a soft damp cloth. 4. Check the condition of the safety shield (see chapter: Installation Instructions) before every use. 5. Check Power supply cable and DMX control cable proper conditions 10. SAFETY STANDARDS Europe: The product conforms the Applicable European Directives & Standards Low Voltage Directive: 73/23/EEC (as amended by 93/68/EEC) EMC Directive: 89/336/EEC (as amended by 92/31/EEC & by 93/68/EEC) Europen Standards:: EN 60598-2-17, EN 60598-1, EN 55015, EN 61547 Disposing of this product: Help preserve the environment! Ensure that this product is recycled at the end of its life. This product is in compliance with the RoHS and WEEE directives.