Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

Similar documents
Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch. with 32 User Bands with Terrestrial input & 1 Legacy port

Satellite B or D. Satellite Inputs (LNB Trunk)

Installation location

Register your product and get support at SDV5122/27. EN User manual

User guide. Stand alone Multiswitches SMC Cascadable Multiswitches SMU Amplifiers. Multiswitches

User Manual. SCR Multiswitch Ref. 9744SKY, 9746SKY, 9748SKY


User s manual OLY 9X K OLY 9X OLY 9V. User s Guide. Headend cascade multiswitch OLY 9X K Cascade multiswitch OLY 9X. Cascade line amplifier OLY 9V

User Manual. dcss/dscr Multiswitch 9733PL 9734PL

Installation Manual VIP 1003

DMOD1200MS. HDMI Modulator. User Manual PLEASE READ THE MANUAL COMPLETELY BEFORE USE V.17.09


Multi-Channel Passive Transceiver Hubs Installation Sheet


2.0 Wall Mount TV Soundbar Instruction Manual

User Manual. dcss/dscr Multiswitch 9732

TVAC20000 User manual

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

Monochrome Video Monitors

Power Injector 1520 Series

ZVOX AccuVoice TV Speaker Model AV203

INSTALLATION MANUAL VIP 1903 / VIP 1903 T VIP 1963 / VIP 1963 T

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Thank you for purchasing a qualiton APR204 preamplifier!

ACTIVE IF SPLITTER/COMBINER UHP-IFS

SATRI AMPLIFIER AMP-51R. Owner s Manual

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

Operating Instructions

ROUGH DRAFT. Guide. Installation. Signal Booster. Wilson. AG Pro 75 Smart Technology In-Building Wireless 800/1900 Signal Booster.

CM-S23349SV. Vari-Focal IR Bullet Camera

ZVOX AccuVoice TV Speaker Model AV203

Outdoor IR Audio Camera

TV Ears TV Speaker Installation Guide

Unicable II Programmer. IDLU-PROG01-OOOOO-OPP Item: Installation & User Guide

Model 1606 Super. User Manual

CM-S38901SV TVL IR Long Range camera

HDMI 1-in 1-out Extender via CAT-5e/ CAT-6

ZIG-POEPRO-70A. HDBaseT HDMI Extender

DDW36C Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement

HD Digital MPEG2 Encoder / QAM Modulator Get Going Guide

HD Digital MPEG2 Encoder / QAM Modulator

Thank you for purchasing a qualiton PHONO preamplifier!


Warnings and Precautions

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

HD Digital MPEG2 Encoder / QAM Modulator

Indoor/Outdoor Security System with Quad Monitor User s Manual

UK. Multi Channel Programmable Filter-Equalizer. User Manual FEATURES. - Designed for both digital and analogue channels,

TS2.8 Sub OWNER S MANUAL

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

DisplayPort Extender over 2 LC Fibers

HD Digital Set-Top Box Quick Start Guide

ZvBox 150. HD video distribution over COAX Get Going Guide

ZIG-POC-100. HDBaseT HDMI Extender

Evolution Digital HD Set-Top Box Important Safety Instructions

User Manual. HDMI Modulator Ref & SW Release

OWNER S MANUAL HD-2CAT-1080P-130. Binary 2CAT Extender WELCOME TO THE BINARY BRAND OF PRODUCTS

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

DisplayPort Extender over 2 LC Fibers

HDMI Converter. Operating Instructions(P/N of this Instructions is INSYH0101)

EXT-HBT70-SET_2016V1.2

Operating Instructions

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

PH-1. Italian MM & MC Phono Preamplifier OWNER S MANUAL

1812R Blues King 12. User Manual

SyncGen. User s Manual

BP2-MM MM Phono Preamplifier Owner s Manual

Multi Channel Programmable Filter-Amplifier. User Manual I-II III V-U SAT. Stop Channel SAT Slope Start Channel SAT ON / OFF.

4KEX70-L. HDBase-T Lite Extender. User Manual

TRF STEP-DOWN TRANSFORMER USER MANUAL

User Manual TPHD-BYE. HDBaseT Extender Set 70m. All Rights Reserved. Version: TPHD-BYE_2014V1.0

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

User Manual CS-HDBTLPOER m HDBaseT Extender with Bi-directional PoE. Version: V1.0.0

DLP200M 2 Relay Module for Heating and Cooling Plants

LINK EXT40-4KUHD 4:4:4 HDR HDBaseT Extender. User Manual. Version: V1.0.1

HDTV Supply Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written

LIGHT COPILOT II. elationlighting.com Internet:

User Guide. TMDS 5x C Digital SCR Multiswitch for SkyQ. Version B Date 02/2016 EN TMDS 54 C TMDS 58 C

In-Line or 75 Ohm In-Line

Installation Guide VL-MV10. Model No.

VLHDMIEXTFIB_2017V1.0

Zigen ZIG-PAX. Premium Digital / Analog Audio Extender. 4K 60 Hz 4:4:4 HDCP 2.2 ZigNet, Full Web Interface and System Diagnostics

SAFETY INFORMATION. 7. Do not force switched or external connections in any way. They should all connect easily, without needing to be forced.

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

User Instructions. 16 SCB Sync Station.

Operating Instructions

Q-TV2. User Manual. for Screens

01. Stay safe. Privacy information

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

TV Ears Wireless Speaker User Manual

MX-DIGITAL COAXIAL CONVERTER MX-1226

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

ER-100 Eurorack 8 Channel Stereo, Transformer Balanced Out Summing Mixer User Manual

User Manual TP70P. HDBaseT Extender Set 70m. All Rights Reserved. Version: TP70P_2016V1.0

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

Contents. Disclaimer of Product and Services

Technical Specifications

Passive Four Channel Stereo/Mono Mixer/Splitter. Artcessories. User's Manual

User Manual TP70L. HDBaseT Extender. All Rights Reserved. Version: TP70L2016V1.1

Transcription:

Satellite multiswitch Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16) EMP-CENTAURI is a registered trademark

Dear Customer, Thank you for buying the EMP-Centauri satellite multiswitch. Before installing and operating the multiswitch read carefully these instructions for use. Keep these instructions for use in a safe place. The multiswitch may be installed and connected only in strict compliance with these instructions for use and applicable standards. Field of Multiswitch Application, Warranty The multiswitch is designed for the distribution of television and radio signals, both satellite and terrestrial, in home installations. The warranty does not apply to products used for other purposes than those specified herein. The user shall be responsible for any injury or loss of property incurred as a result of any use which was not in agreement with these instructions for use. The product uses technologies protected by copyrights and patents. Any disassembling of the multiswitch and any changes thereof are prohibited. To ensure quality warranty and after-warranty services, please keep all documents about your purchase and repairs of the product, if any. We recommend keeping the original packaging of the product throughout the warranty period. Product takeover Make sure the following accessories are enclosed to the multiswitch: Screws and dowels to fix the multiswitch on the wall 4 pieces F connectors designed for installation on the coaxial cable, whose number corresponds to the number of multiswitch input and output connectors Terminators for impedance adjustment of unused outputs 2 pcs If some accessories are missing, please contact your dealer. Device placement Fix the multiswitch firmly on a wall or another hard and inflammable surface. Use the enclosed screws and dowels for installation. Drill holes for the screws as shown in the drawing below: P. 154-UP, P. 155-UP: 4 x Ř 5,0 P. 150-UP-12, P. 150-UP-16: 4 x Ř 5,0 145,0 145,0 296,0 416,0-1-

The multiswitch shall be in no case held only with the connected cables. Place the multiswitch in a dry environment, do not expose it to rain or excessive humidity or dropping or running water. Do not place any containers with liquids (vases etc.) on the device. Do not install the multiswitch close to heat sources such as radiators or air ventilators, in places exposed to direct sunshine or in places with high dust pollution, mechanical vibrations or impacts. Choose an installation place where the device is protected against liquids (water) or foreign objects. Make sure that the multiswitch and its electric connections are out of the reach of children. Make sure that the ventilation openings on the device are not covered or blocked, e.g. with a newspaper, tablecloth or curtains and that the space around the device is sufficiently ventilated. The free space on sides should be at least 20 cm and the space over its top at least 50 cm. The installation place should enable easy access to the power cable so that the device can be readily disconnected from the grid if needed! Device connection Use the following or similar connection diagram to install the multiswitch: Terrestrial input LED diode Earthing terminal Power supply (50-60 Hz) lever switches Installation openings for fixing screws Terrestrial input LED diode Earthing terminal Power supply (50-60 Hz) lever switches Installation openings for fixing screws -2-

To connect the multiswitch inputs and outputs use high-quality coaxial cable designed for satellite reception and F connectors. Use a high-shielding coaxial cable, min. 90dB. If F connectors are not attached onto the cables, remove first the outer cable sheath in the length of approx. 15 mm. Then roll up the metal shielding braid and the shielding foil underneath and cut the shielding with scissors to ca. 5 mm. Then remove ca. 10 mm of the inner plastic insulation so that ca. 5 mm of the insulation remains in place. Then carefully screw on the F connector on the cable end until the plastic insulation levels with the connector opening. Prevent short circuit between the inside conductor and the shielding. The short circuit prevents reception, it is difficult to identify and in extreme cases it may even damage the multiswitch or satellite receiver! The coaxial cables shall not be broken; the minimum bending radius shall be 5 cm. Connect the cables from the s and satellite converters () to the multiswitch connectors identified with symbols. When making connections pay close attention to identification of converter connectors! Connect the input marked 13V/0kHz ( A) with the output of Vertical converter in case of the converter, or with the output of Vertical Low in case of the converter. Connect the input marked 18V/0kHz ( B) with the output of Horizontal converter in case of the, converter, or with the output of Horizontal Low in case of the converter. Connect the input marked 13V/22kHz ( C) with the output of Vertical converter in case of the converter, or with the output of Vertical High in case of the converter. Connect the input marked 18V/22kHz ( D) with the output of Horizontal converter in case of the, converter, or with the output of Horizontal High in case of the converter. Connect the input marked 13V/0kHz ( E) with the output of Vertical converter in case of the converter, or with the output of Vertical Low in case of the converter. Connect the input marked 18V/0kHz ( F) with the output of Horizontal converter in case of the converter, or with the output of Horizontal Low in case of the converter. Connect the input marked 13V/22kHz ( G) with the output of Vertical converter in case of the converter, or with the output of Vertical High in case of the converter. Connect the input marked 18V/22kHz ( H) with the output of Horizontal converter in case of the converter, or with the output of Horizontal High in case of the converter. Also Quad-type converters can be used (with an integrated multiswitch) or Universal for reception of the High Band. The multiswitch is provided with four miniature lever switches situated close to the multiswitch output connectors. If the switch 3 is in the ON position the multiswitch continually transmits to inputs G and H a signal of 22kHz which switches the corresponding outputs to the High Band. If the switch 4 is in the ON position the multiswitch continually transmits to inputs C and D a signal of 22kHz which switches the corresponding outputs to the High Band. Further the multiswitch transmits 13VDC to inputs A, C, E, G and 18 VDC to inputs B, D, F, H. The Quad converter then operates as converter and the Universal converter operates as Dual converter for High Band reception. Switching between the satellite system A, i.e. the four inputs A through D, and the satellite system B, i.e. the four inputs E through H, is possible with commands DiSEqC Position A and B from the satellite receiver. Connect the multiswitch input marked Terr. Antenna with the output for reception of terrestrial TV and radio. This input additionally enables to power supply the pre-amplifier with the current up to 100mA and 12 to 13 VDC is brought to the input provided the mini switch 2 is in the ON position. Provided the current consumed by the pre-amplifier exceeds 100 ma an internal fuse disconnects the power supply of the pre-amplifier. The may be also connected directly to the Terr. Antenna multiswitch input; in this case the power supply voltage is short-circuited and disconnected at the multiswitch input, however the signal quality for terrestrial TV and radio is not affected. The attenuation controller at the Terr. Antenna input may regulate the level of signals from the terrestrial TV and radio or from the pre-amplifier. If the mini switch 1 is in the OFF position, the internal amplifier of the terrestrial TV and radio is switched off and the multiswitch operates as a passive hub for terrestrial TV and radio. In this case the multiswitch is able to transmit the so-called reverse channel. -3-

All satellite multiswitch inputs are provided with attenuation controllers which provide the option to equalize signals of various strength at the inputs. This, however, requires adequate measuring instruments. The output connectors of the multiswitch are identified with OUT symbols. Run cables from the multiswitch outputs into terminal subscriber outlets or hubs for satellite and terrestrial signals. If the Terr. Antenna input is not connected the cables from outputs may run directly into satellite receivers. We recommend impedance adjustment of unused outputs (OUT) or Terr. Antenna input by screwing on terminators. Never connect the load to the satellite inputs! A stand by mode is used for power supply of converters. This means that individual fours of satellite inputs are disconnected from power provided none of the given four receives a signal. In practice, none of the receivers may be on and then all converters are disconnected and the multiswitch minimizes its consumption.. Safety The device shall be properly grounded for safety reasons. Use the earthing terminal to ground the multiswitch identified with the symbol. WARNING! Connect all devices into the grid only after they are completely connected and checked. Make sure the s are grounded properly. The multiswitch operation is indicated with a LED diode on the power supply. Never open the powered device as this may result in an electrical accident! Never work on the multiswitch, TV set or other powered devices during or before a storm! A lightning stroke into the may cause dangerous overvoltage in the device metallic parts. If you have any doubts about proper grounding of the feeder turn to a qualified electrician for help because s and their feeders are subject to earthing regulations. The device uses 100-250VAC with frequency 50-60Hz. Make sure the local grid voltage corresponds to the operating voltage of the device. Ensure sufficient air circulation to prevent internal overheating of the device. Use the device in dry conditions only. If the device gets into contact with liquids (e.g. dropping water or spilled drinks) it shall be disconnected from the grid immediately. Do not place any objects on the power supply line to prevent its damage or constriction and make sure it is not in contact with hot objects. To prevent an electric accident the cover can be opened, the device can be installed or cleaned only when disconnected from the power grid. Use only dry cloth to clean the device and do not use any liquid agents. The device should be disconnected from the grid also if it is not to be used for a long period of time. When disconnecting the device, never pull the cable but always the plug to prevent damage of the cable. Make sure the plug is firmly inserted into the outlet. Wobbly plugs and outlets result in fire risks. The device shall be serviced by qualified experts only. Troubleshooting Disconnect plugs of the multiswitch, satellite receiver and TV set from the grid whenever working with the connectors or equipment. Any work on energized equipment may result in a fatal electric accident! If you have to enter places with a risk of fall, pay attention to your safety. Repairs should be performed by qualified personnel only. In case of a failure, check systematically for potential defects. Make sure the satellite is properly fixed, connected and adjusted and that the satellite receiver is installed, connected and switched on according to the available instructions. A frequent defect is short-circuit in the cable which prevents power supply of converters. Check whether the connectors are carefully and correctly connected on the multiswitch, converters as well as satellite receiver. When the cable connected into the multiswitch input is short-circuited it disconnects the power supply to the multiswitch. The diode inside the power supply is off. If this is the case, disconnect the device from the grid and then find and remove the short circuit on the cable. Then re-plug the device into the grid. Broken or interrupted coaxial cables may cause defects as well. The most frequent defects are in connector joints, e.g. if the central conductor is too short and fails to make contact in the connector. Also the shielding braid shall make good contact with the connector coat. Sometime a reset of the multiswitch microprocessor is enough to fix the problem: pull out the power plug of the satellite receiver and of the multiswitch and then re-plug them a few seconds later. If you are unable to remove the defect yourselves, contact your distributor. -4-

Multiswitch maintenance Always disconnect power supply cables of all installed devices when performing any maintenance on the multiswitch installation or equipment! Check regularly the ventilation openings on the multiswitch power supply for blocking or fouling. Use only dry cloth for cleaning. Coaxial cables installed outdoors should be replaced once in a few years. Cables are exposed to climatic conditions, particularly if the outdoor cable length exceeds 20m. Not only the cables quality but also their age is of essence, particularly for receipt of weak satellite signal. Check regularly connection cables in the installation. Every 2 years unscrew the coaxial cable and clean connector contacts or shorten the coaxial cable by ca. 2 cm and screw on the F connector again because this is where corrosion occurs most frequently. Regularly check the power supply condition and its power cord. If the cord is damaged or worn on the surface, have the device serviced. Any damage of the power supply cover shall be serviced as well. Technical parameters Frequency Range inputs 950-2300 MHz Input Terr. Antenna 5-862 MHz (passive mode) 40-862 MHz (active mode) Outputs 5-2300 MHz (passive mode) 40-2300 MHz (active mode) Control of the multiswitch from a satellite receiver using commands 13/18V (10-14.5 / 15.5-20V), 0/22 khz, Tone Burst, or DiSEqC. Power supply: Main voltage 100 250VAC frequency 50/60Hz Maximum permitted power consumption 45W Output voltage of the power supply 18VDC at the max. current 2A The device can be used in dry environment only! Explanation of symbols on the device DIGITAL SATELLITE EQUIPMENT CONTROL DiSEqC (Digital Satellite Equipment Control) international standard for digital satellite equipment control Conformity marking For indoor use only Class II device Safety transformer DC power supply Fuse protected Disposal instructions According to the EU Directive, electric and electronic devices marked with one of the following symbols shall not be disposed of together with municipal waste. Use local waste collection and recycling systems to return retired devices. -5-

We also offer the following products from our production program: P. 142-UP (5/4), P. 143-UP (5/8), P. 146-UP (5/12), P. 147-UP (5/16) (50-60 Hz) (50-60 Hz) P. 149-AP-20 (5/20), P. 149-CP-20 (5/20), P. 149-AP-24 (5/24), P. 149-CP-24 (5/24), P. 149-AP-28 (5/28), P. 149-CP-28 (5/28) (50-60 Hz) (50-60 Hz) P. 150-AP-12 (9/12), P. 150-CP-12 (9/12), P. 150-AP-16 (9/16), P. 150-CP-16 (9/16) (50-60 Hz) (50-60 Hz) P. 170-AP-8 (17/8), P. 170-CP-8 (17/8), P. 170-AP-12 (17/12), P. 170-CP-12 (17/12), P. 170-AP-16 (17/16), P. 170-CP-16 (17/16) 4 x (50-60 Hz) (50-60 Hz) -6-

EMP-CENTAURI s.r.o. 5. května 690, 339 01 Klatovy Czech Republic info@emp-centauri.cz www.emp-centauri.cz