CA-800 Tear Module. Rick Gaudenti. Product Manager, Refraction Mar 2017

Similar documents
Arthur Cummings FRCSEd

Vision Call Statistics User Guide

PYROPTIX TM IMAGE PROCESSING SOFTWARE

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

Index. - Registration assistant of momit Home 1 - Start of session/registration 2 - Registration of devices. - momit Home App 1.

Getting started with Spike Recorder on PC/Mac/Linux

HBI Database. Version 2 (User Manual)

Premium treatment starts with premium diagnosis

Novel Microscope Mounted Digital Keratoscope for Intra-Operative Toric IOL Alignment

NanoTrack Cell and Particle Tracking Primer

Operating Manual. CenterVue COMPASS Operating Manual Page 1 of 83

Calibrating and Profiling Your Monitor

Silver Mountain Targets V2 Software Reference Guide. July 22, 2015

To show the Video Scopes, click on the down arrow next to View located in the upper- right corner of your playback panel.

User Guide. S-Curve Tool

Quick Reference Manual

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

Lab experience 1: Introduction to LabView

Operations Manual RD-BR1. Radian Research, Inc. CT Burden & Ratio Analysis Module

Scanning Electron Microscopy (FEI Versa 3D Dual Beam)

4/9/2016. Sources of. Single-angle vs. double-angle plots for astigmatism data. Commercial Toric IOL calculators. Unexpected residual astigmatism!

Motion Amplification

Connection for filtered air

The Customizable Robot Face Module

Field Test 2. Installation and operation manual OPDAQ Installation and operation manual

Software Quick Manual

Rack-Mount Receiver Analyzer 101

ViewCommander- NVR Version 3. User s Guide

D-Lab & D-Lab Control Plan. Measure. Analyse. User Manual

Configuring and Troubleshooting Set-Top Boxes

Operating Instructions

SIDRA INTERSECTION 8.0 UPDATE HISTORY

Software Quick Manual

1 About the Terason Ultrasound System

Technical Specifications

CAVITY EYE SMART MOULDING CONTROL USER MANUAL

PulseCounter Neutron & Gamma Spectrometry Software Manual

Software Quick Manual

TI-Inspire manual 1. Real old version. This version works well but is not as convenient entering letter

E X P E R I M E N T 1

EAN-Performance and Latency

VISSIM TUTORIALS This document includes tutorials that provide help in using VISSIM to accomplish the six tasks listed in the table below.

Pre-Processing of ERP Data. Peter J. Molfese, Ph.D. Yale University

The Diverse Multimedia & Surveillance System Via Dico2000 with PC DICO Operation Manual

Source/Receiver (SR) Setup

What s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven

GETTING STARTED... 2 ENVIRONMENT SCAN... 2

Version Users Manual

Logic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display

Spectacle Motion Board Hookup Guide

DektakXT Profilometer. Standard Operating Procedure

Disclosure. Getting Up to Date with LASIK. Modern advancements LASIK. What we re curing. Changing the corneal surface

EYE TRACKING DATA ANALYSIS TOOL

Evaluation Tools. Journal Impact Factor. Journal Ranking. Citations. H-index. Library Service Section Elyachar Central Library.

Analysis of WFS Measurements from first half of 2004

Nature Neuroscience: doi: /nn Supplementary Figure 1. Ensemble measurements are stable over a month-long timescale.

Edit Daily Schedules

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

YouCompose User Manual

MultiQ Digital signage template system for widescreen monitors

Dektak Step by Step Instructions:

4. ANALOG TV SIGNALS MEASUREMENT

LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution. A. Plotting a GM Plateau. This lab will have two sections, A and B.

MAutoPitch. Presets button. Left arrow button. Right arrow button. Randomize button. Save button. Panic button. Settings button

Word 4 Activity 1 - Report

A-ATF (1) PictureGear Pocket. Operating Instructions Version 2.0

User Guide for Customers Register & Reserve Colours

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

FAST MOBILITY PARTICLE SIZER SPECTROMETER MODEL 3091

Diamond Piano Student Guide

TUTORIAL IGBT Loss Calculation in the Thermal Module

GBA 327: Module 7D AVP Transcript Title: The Monte Carlo Simulation Using Risk Solver. Title Slide

After Effects Compositing Basics

Figure 1. MFP-3D software tray

Audio Compression Technology for Voice Transmission

Setup Guide. Klein K-10CP Colorimeter. Rev. 1.1

VM15 Streamer V User s Guide

Activity P27: Speed of Sound in Air (Sound Sensor)

White Paper. Astigmatism Management With Toric IOLs The Importance of Rotational Stability After IOL Implantation. Xiaolin Gu, M.D., PhD.

Using an IDT Redlake X4 High-Speed Camera with MiDAS DA

A low noise multi electrode array system for in vitro electrophysiology. Mobius Tutorial AMPLIFIER TYPE SU-MED640

Version 1.0 February MasterPass. Branding Requirements

McIDAS-V Tutorial Using HYDRA to Interrogate Hyperspectral Data updated September 2015 (software version 1.5)

WINDOWS GUIDE LIBRESTREAM.COM

Q-Lab Software. for the 8821Q-R OPERATION MANUAL

Tutorial 3 Normalize step-cycles, average waveform amplitude and the Layout program

Signal Stability Analyser

WindData Explorer User Manual

Analyzing Modulated Signals with the V93000 Signal Analyzer Tool. Joe Kelly, Verigy, Inc.

WIDEX FITTING GUIDE PROGRAMMING ZEN FOR WIDEX ZEN THERAPY COMPASS GPS INTRODUCTION BASIC WIDEX ZEN THERAPY FITTING STEPS FOR THE BASIC FITTING

U S E R G U I D E HD1000

Lab 1 Introduction to the Software Development Environment and Signal Sampling

With Export all setting information (preferences, user setttings) can be exported into a text file.

Total corneal astigmatism in older adults taking into account posterior corneal astigmatism by ray tracing

3D QUALITY CONTROL SOFTWARE MPES-3DQC1 USER S GUIDE. [English] 1st Edition (Revised 1) Software Version 1.10

Processor time 9 Used memory 9. Lost video frames 11 Storage buffer 11 Received rate 11

USER DOCUMENTATION. How to Set Up Serial Issue Prediction

sdiscope Signal Analysis Software Version 6

USER MANUAL Version 1.5.2

EDL8 Race Dash Manual Engine Management Systems

Transcription:

CA-800 Tear Module Rick Gaudenti Product Manager, Refraction Mar 2017

Meibomian Gland Imaging

Meibomian Gland [MEIB] Viewing Meibomian Images are displayed in the center of the screen Two types of an adjustable Contrast Enhancement are displayed directly below the image Thumbnails of additional images captured during the same exam are displayed below the main image

Meibomian Gland [MEIB] Viewing Contrast Enhancement Soft - 5% Soft - 50% Soft Contrast Enhancement Soft - 95% As the slider is increased the dark areas of the image are made darker relative to the bright areas

Meibomian Gland [MEIB] Viewing Contrast Enhancement Hard - 5% Hard Contrast Enhancement Hard - 50% Hard - 95% As the slider is increased the bright areas of the image are made darker relative to the dark areas

Meibomian Report Output The Meibomian Gland images can now be output as a report. Previous versions required using the screenshot output to export Meibomian Gland images

Meibomian Report Sample Patient information is included in the header at the top of the page Right eye [OD] is displayed above the Left eye [OS]

Tear Module

Tear Module The new Tear Module for CA-800 Introduces new Acquisition and Viewing modes to enhance the dry eye application of the CA-800 BLINK Blink Detection Records blinks over a period of time Calculates average blinks per minute and blink interval TBT Tear Film Break up Time Calculates First Break up and Average Breakup Allows video playback highlighting the corneal surface

Acquisition New TEAR category in Acquisition TEAR replaces the Extra category Adds Blink detection and Tear Breakup Time acquisition modes

BLINK Acquisition 1. Select the BLINK mode in the TEAR acquisition category 2. Align the CA-800 until the eye image appears clear 3. Press the joystick button to begin acquisition 4. Instruct the patient to blink normally 5. Press joystick button again to complete acquisition

BLINK Acquisition Blinks are automatically detected and counted Blinks per minute and average time between blinks are calculated

TBT(Tear Breakup Time) Acquisition 1. Align to the center of the rings until they become clear 2. Press the joystick button to activate the focusing guides [Red and Blue arrows] 3. Follow the arrows until Green marks are shown in the corners 4. You will see a message at the bottom of the window: CORRECT FOCUSING ASK PATIENT TO BLINK

TBT(Tear Breakup Time) Acquisition cont. 5. Blink is automatically detected and analysis of the Tear Film behavior begins 6. Acquisition stops automatically when a second blink is detected NOTE: If a second blink occurs within 5 seconds of the first blink, analysis is automatically restarted. Maximum duration is 50 seconds

TBT(Tear Breakup Time) Acquisition Results When acquisition stops, the result of analysis is displayed. Three results are possible: Breakup Detected First Breakup and Avg Breakup results are displayed No significant breakup detected Wrong Sequence! Acquisition is discarded, repeat Tear Breakup Time acquisition

Tear Module Viewing A new tab is displayed on the left side of the Measurements Viewing screen TBT is added for viewing Blink detection and Tear Film analysis

Summary Tab The Summary Tab displays statistics and graphical data related to the Tear Film condition for all TBT acquisitions of the currently selected exam

Summary Tab Thumbnails Thumbnails Thumbnails of additional TBT acquisitions captured during the selected exam Color-coded Sector map shown for other acquisitions

Summary Tab Sector Map Sector Map Shows each sector where Breakup was detected for all TBT acquisitions of the selected exam Sectors color-coded by time when Breakup occurred

Summary Tab- Stats Δ5% Level BUT Average time at which the percentage of sectors with Breakup reached 5% IBI (Inter-Blink Interval) Time between blinks OPI < 1 indicates a potential Dry Eye issue OPI (Ocular Protection Index) Rate between Δ5% Level BUT and IBI (Δ5% Level BUT/IBI) for all TBT acquisitions of selected exam.

Summary Tab Breakup Graph Breakup Graph Plots % of sectors with Breakup over time for all TBT acquisitions of the selected exam

TBT Tab The TBT Tab displays statistics and graphical data related to the Tear Film condition for the selected TBT acquisition

TBT Tab Thumbnails Thumbnails Thumbnails of additional TBT acquisitions captured during the selected exam Color-coded Sector map shown for other acquisitions Yellow outline indicates selected Acquisition

TBT Tab Sector Map Sector Map Shows each sector where Breakup was detected for the selected TBT acquisition Sectors color-coded by type when Breakup occurred

TBT Tab - Stats Duration Measurement Time 5% Level TBT Time at which the percentage of sectors with Breakup reached 5% IBI (Inter-Blink Interval) Time between blinks OPI < 1 indicates a potential Dry Eye issue OPI (Ocular Protection Index) Rate between 5% Level TBT and IBI (5% Level TBT/IBI)

TBT Tab Breakup Graph Breakup Graph Plots % of sectors with Breakup over time for the selected TBT acquisition

Maps Tab The Maps Tab allows you to play back a recording of the selected acquisition with various optional overlays

Maps Tab Playback Modes Keratoscopy Play back the acquisition with no overlay to see the quality of the Placido rings Breaks Play back the acquisition with an overlay that highlights the quality of the tear film based on the Placido rings Map Play back the acquisition with an overlay of the Topography Maps Wavefront Play back the acquisition with an overlay of Wavefront Aberration maps Export Video To the left of the playback modes is an Export Video Icon that allows you to save the video to USB drive or shared network folder

Maps Tab - Keratoscopy Keratoscopy allows you to play back a recording of the selected acquisition so the quality of the Placido rings can be seen Rings at 8 seconds

Maps Tab - Breaks Breaks allows you to play back a recording of the selected acquisition with an overlay of the Tear Film Breakup color-coded by Breakup severity Green indicates good tear film Orange and Red indicate Breakup Breakup Graph is displayed along the bottom of the Breaks video showing % of Sectors w/breakup over time

Maps Tab - Map Map allows you to play back a recording of the selected acquisition with the Topography map overlay to see the change in topography caused by dry eye Axial or Tangential map types can be overlaid

Maps Tab - WaveFront WaveFront allows you to play back a recording of the selected acquisition with an overlay of Wavefront Aberrometry Maps to show the effect of the tear film breakup on the patients visual quality The user can choose to overlay any or all of the following Wavefront Aberrometry maps: OPD (total Wavefront Aberration) Astigmatism Spherical Aberration Coma High Order A Graph is displayed along the bottom of the WaveFront video showing total Wavefront RMS over time

Maps Tab Export Video Any of the Maps videos can be exported by touching the Export Video icon

Blink Tab The Blink Tab shows statistics related to the Blink Acquisition

Blink Tab - Stats Avg. IBI (Inter-Blink Interval) Average time between blinks IBI Std Dev Standard Deviation of average time between blinks Duration Amount of time of Blink Detection acquisition #Blink/min Number of blinks per minute

Thank you