Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

Similar documents
3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater. Installation and Operations. Manual

DIGILINK DLT710 FUNCTION MODULE

SERIAL DIGITAL VIDEO FIBER OPTIC TRANSPORT & DISTRIBUTION MODULAR SYSTEM FOR HDTV & SDTV

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

FiberLink 3500 Series Transceivers

FiberLink 3350 Series

FiberLink 3355 Series

8 Port HD/SD-SDI Switch

Model 7600 HD/SD Embedder/ Disembedder Data Pack

CardModule. Reference Manual. Series C DA Channel SDI to CVBS Converter. Version 1.0

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

Instruction Manual RT-91600D-SL RR-91600D-SL Sixteen Channel Video Multiplexer With Remote Diagnostic Interface

8 Port HD/SD-SDI Video Switch with 2 Port Splitter

INSTRUCTION MANUAL VF MultiDyne. Harnessing The Power of Light

3G/HD/SD-SDI to HDMI Converter

INSTRUCTION MANUAL. FiberSaver Series, FS-6000, FS-12000, FS-18000

SDI-SDHDXPRO User Manual. Version1.2

SDI-HDRPTPRO. User Manual. HD-SDI Repeater with Signal Equalization & Re-clocking. Version 1.2

Reference Manual D VD 5820

FiberLink 7142 Series

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

IQORX30 / IQORX31. Single Mode Fiber Optic Receivers for 3G/HD/SD-SDI Signals

OptEnet OC48 Regenerator Module User Manual

TECHNICAL MANUAL INTEGRITY 600 SERIES MDX644 HD/SD, AES/DOLBY E AUDIO DE-EMBEDDER/EMBEDDER

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Intraplex VF-25 Four-Port PCM E&M Voice Module

User Instruction Manual IQSDA30/IQSDA32. Intelligent Reclocking High Performance HD-SDI/SD-SDI Distribution Amplifiers. snellgroup.

OmniStar GX2 Headend Optics Platform

TECHNICAL MANUAL. Cheetah VIDEO MATRIX ROUTERS 3G VIDEO INPUT CARD WITH AUDIO DE-EMBEDDING AND 3G VIDEO OUTPUT CARD WITH AUDIO EMBEDDING

VGA to DVI Extender over Fiber SET

SDI-HDSDXPRO. USER MANUAL Version 1.1

User Manual TL-TP70-HDIR 70m Extender with ARC and IR All Rights Reserved Version: TL-TP70-HDIR_180723

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs)

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

ASSEMBLY INSTRUCTIONS

opengear OPG-1L 50 MHz-2.3 GHz

16 SFP ports and 16 BNC. built in. 24 SFP ports, 8 BNC

LWX-1. Satellite Weather Radio Module Installation Instructions A

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

FIM-108 MATRIX FIBER INTERFACE INSTRUCTION MANUAL

Product Operation Manual

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION DA-3G CONNECTIONS SPECIFICATIONS SERIAL VIDEO INPUT...

V pro8 QUICK START GUIDE

ChromaFlex. ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules HARDWARE INTERFACE MANUAL.

User Instruction Manual IQOTR31. 3G/HD/SD-SDI Single Mode Fiber Optic Transceiver. snellgroup.com

Prisma II Forward Receiver Installation and Operation Guide

Perle Fast Ethernet Media Converters

PATTERN GENERATOR PG-3D1X USER MANUAL V.2012PG-3D1X101.00

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

ACTIVE IF SPLITTER/COMBINER UHP-IFS

High Performance fibre systems

HD Digital Set-Top Box Quick Start Guide

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

DM1624, DM1612, DM812

Model 5240 Digital to Analog Key Converter Data Pack

ASP-FIBRS1 User Manual

Installation Manual. Fiber Optic Transmission Systems. VOS-1VGA-LT/R series 1-Channel VGA Extender over Fiber VOSCOM TECHNOLOGIES CO.

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

4, 8, 16 Port VGA and Audio Extender / Splitter with Audio over Single CAT5

VGA & RS232 Extender SET over Single CAT5 with RGB Delay Control

VGA, Audio & RS232 Extender SET over Single CAT5 with RGB Delay Control & IR Pass Through

Reprinted with kind permission from

8Ch CWDM 3G-SDI Fiber Extender kit User Manual L-XSDI-CWDM-3G-TX/RX

Mini HD-SDI Optical Transceiver Model No : VCF-MF01TXRX

OMNISTAR GX2. GX2-LM1000E Series 1310 nm Broadcast Transmitter DATA SHEET BENEFITS. 1 GHz bandwidth

Model 6010 Four Channel 20-Bit Audio ADC Data Pack

FS3. Quick Start Guide. Overview. FS3 Control

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

Perle Fast Ethernet Media Converters

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

F M2SDI 2 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485 & Aux. User Manual

FS1-X. Quick Start Guide. Overview. Frame Rate Conversion Option. Two Video Processors. Two Operating Modes

Model 7130 HD Downconverter and Distribution Amplifier Data Pack

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

User Manual TP70L. HDBaseT Extender. All Rights Reserved. Version: TP70L2016V1.1

Z-IP Stream 004/008. User Guide and Installation Manual. Four or Eight Input QAM Encoder / Modulator

APSPB PUSH BUTTON ZERO Installation Manual

EXT-SDHDX. Mini SDI to HDMI Converter

I N S T R U C T I O N D A T A

MONOPRICE. BitPath AV SDI Extender over Single Cat6 Cable, 120m. User's Manual P/N 16227

INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

CLUX-SDI2HC. 3G SDI Extender with HDMI Converter. Operation Manual CLUX-SDI2HC

HD-3500 Series. HD Video, Audio, Data & Tally/GPIO Channels FEATURES

3G fiber. TL7075/76 Optical 3Gbit/s Link solution with full duplex Communication Channel. TL Features. TL Features

Truck router (3Gbps/HD/SD/ASI)

blink USER GUIDE Bluetooth capable Reclocker Wyred 4 Sound. All rights reserved. v1.0

User Guide. HDMI Fiber Optic Extender. DVI-7350a

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

Transcription:

Manual DigiLink DLC156 Function modules Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI Installation and Operations Manual WWW.ARTEL.COM

ii DLC156 Function Modules Installation and Operations Manual

DLC156 Function Modules Six-Channel TDM Multiplexer for 3G, HD, SDI, and ASI Installation and Operations Manual Document Number: AR200-008201-00_F Released: September, 2017 DLC156 Function Modules Installation and Operations Manual iii

iv DLC156 Function Modules Installation and Operations Manual

COPYRIGHT This manual is produced and copyrighted by Artel Video Systems Corporation. Any use or reproduction of the contents of this manual without the prior written consent of Artel Video Systems Corporation is strictly prohibited. NOTICE All title and copyrights to this document are owned by Artel Video Systems Corporation. No part of the contents of this document may be reproduced or transmitted in any form or by any means without the written permission of Artel Video Systems Corporation. Artel Video Systems Corporation shall not be liable for errors contained herein. Artel Video Systems Corporation shall not be liable for any damages whatsoever, including, without limitation, damages for loss of business profits, business interruption, loss of business information, or other pecuniary loss arising out of the use of this documentation even if Artel Video Systems Corporation has been made aware of the possibility of such damages. Information contained in this document is subject to change without notice. While every effort is made to ensure that the information is accurate as of the publication date, users are reminded to update their use of this document with documents published by Artel Video Systems Corporation subsequent to this date. Updates may be available at www.artel.com or by contacting Artel Video Systems Corporation. Third-party product information is for informational purposes only, and constitutes neither an endorsement nor a recommendation. Artel Video Systems Corporation assumes no responsibility with regard to the performance of the third-party products. Copyright 2017 by Artel Video Systems Corporation ALL RIGHTS RESERVED Printed in U.S.A. Artel Video Systems Corporation 5B Lyberty Way Westford, MA 01886 (978) 263-5775 www.artel.com DLC156 Function Modules Installation and Operations Manual v

Revision history for the DLC156 Function Modules Installation and Operations Manual. Table 0-1. Manual Revision History Revision History Revision Document Number Date Reason for Change A AR200-008201-00_A May, 2013 Initial release. B AR200-008201-00_B May, 2015 Copy edits and new graphics. C AR200-008201-00_C July, 2015 Modified Related Documentation section. D AR200-008201-00_D February, 2016 Updated Artel logo. E AR200-008201-00_E December, 2016 Updated images, block diagram, copy edits. F AR200-008201-00_E September, 2017 Modified Cabling the DLC156D Module section and Table 9. DLC156D Front and Rear Panel Status LEDs vi DLC156 Function Modules Installation and Operations Manual

Table of Contents About This Manual Audience... ix Related Documentation... ix Symbols and Conventions... x Artel Customer Service... x DLC156 Function Modules Information About the DLC156...1 Understanding and Using the DLC156M...2 DLC156M Module Functional Description...2 Overview of the DLC156M Module...3 Configuring the DLC156M Module...5 Configuring the Video Rate with SW1, SW2, and SW3... 5 Enabling Channels with DIP Switch SW4... 6 Configuring Repeater and EMS Features with DIP Switch SW5... 7 Installing the DLC156 Module and XFP...8 Cabling the DLC156M Module... 10 Monitoring the DLC156M Module Operation... 10 Understanding the DLC156M Status LEDs...10 Using the DLC156M Monitor Jack...12 Removing the XFP and DLC156 Module... 12 Removing the XFP...12 Removing the DLC156 Module...13 Understanding and Using the DLC156D...13 DLC156D Module Functional Description... 13 Overview of the DLC156D Module... 15 Configuring the DLC156D... 16 Enabling Channels with Switch SW1...17 Enabling Video Alarm, Optical Repeater, and EMS with DIP Switch SW2...17 Installing the DLC156D Module and XFP... 18 Cabling the DLC156D Module... 18 Monitoring the DLC156D Module Operation... 19 Understanding the DLC156D Status LEDs...19 Using the DLC156D Monitor Jack...21 Removing the XFP and DLC156D Module... 21 Index DLC156 Function Modules Installation and Operations Manual vii

viii DLC156 Function Modules Installation and Operations Manual

About This Manual This manual provides instructions for installing, configuring, and operating the DLC156 function modules, which consist of the DLC156M (mux) and DLC156D (demux) modules. Audience This manual is intended for the following trained and qualified service personnel who are responsible for installing and operating the DLC156: System installer Hardware technician System operator Related Documentation The following documentation contains material related to the DLC156 function module: Document Provides... DLC156M/DLC156D Data Sheet DLC156M Quick Start Guide and DLC156D Quick Start Guide DigiLink Media Transport Platform Installation and Operations Manual DigiLink Media Transport Platform Data Sheet DigiLink Manager Setup and Operations Manual Product operating and environmental specifications, and regulatory conformance information. Product configuration information using the DL Manager element management system and descriptions of the front panel status LED operations. Overview and installation instructions for the DigiLink media transport platform chassis options, including the following: DL4360x chassis Installation of this 12-slot chassis, power supplies, switch module, and function modules. DL4300 chassis Installation of this 12-slot chassis, power supplies, and function modules. DL4000 chassis Installation of this 4-slot chassis, power supplies, and function modules. Overview of the DigiLink media transport platform chassis options. Overview and operating instructions for the DigiLink Manager element management system. DLC156 Function Modules Installation and Operations Manual ix

Symbols and Conventions This manual uses the following symbols and conventions. Caution A caution means that a specific action you take or fail to take could cause harm to the equipment or to the data transmission. Warning A warning describes an action you take or fail to take that could result in death, serious physical injury, or destruction of property. Note: Important related information, reminders, and recommendations. Italics used for emphasis, for indicating the first occurrence of a new term, and for book titles 1. Numbered list where the order of the items is important Bulleted list where the items are of equal importance and their order is unimportant Artel Customer Service You can reach Customer Service by e-mail at customercare@artel.com or by telephone: In the US call (800) 225-0228, then select 1 for technical support. Outside the US call (978) 263-5775, then select 1 for technical support. When requesting assistance, please be ready to provide the following information: Your name and telephone number Product model and serial number Brief description of the problem List of symptoms Steps you have already taken to try to resolve the problem If the product is damaged If any portion of the unit is damaged, forward an immediate request to the delivering carrier to perform an inspection of the product and to prepare a damage report. Save the container and all packing materials until the contents are verified. Concurrently, report the nature and extent of the damage to Artel Customer Service so that action can be initiated to either repair or replace the damaged items. Do not return any items to Artel until you obtain instructions from Customer Service. Report the problem or deficiency to Customer Service along with the model number and serial number. Upon receipt of this information, Artel will provide service instructions, or a Return Authorization Number and shipping information. x DLC156 Function Modules Installation and Operations Manual

Information About the DLC156 DLC156 Function Modules Six-Channel TDM Multiplexer for 3G, HD, SDI, and ASI Information About the DLC156 This manual introduces the two DLC156 function modules and includes information for installing and configuring the modules. The DLC156 can transport up to six HD-SDI or three 3G-SDI digital video services over a single optical wavelength. Using time division multiplexing (TDM), each channel is assigned a fixed time-slot, eliminating complex configurations. The six-channel DLC156 is available in the following models: DLC156M Multiplexer that can aggregate six independent, mixed format video signals onto a single wavelength. Two time slots can be combined to carry 3G-SDI. The electrical inputs are received using the module s six BNC connectors. Optionally, in a switched chassis, up to five of the inputs can be received from other modules using backplane connections. DLC156D De-multiplexer that can receive the aggregated optical signals, separate them, and output them to six BNC connectors. Optionally, in a switched chassis, up to five of the channels can be output to other modules using backplane connections. The DLC156D can be configured to operate as a repeater to extend the range of a link while demultiplexing signals for local use. The DLC156 uses a 10.7 Gb/s XFP transceiver for WDM (1310 nm, 1550 nm), CWDM ITU G.694.2, and DWDM ITU G.694.1. You provision and monitor the DLC156 using DIP switches, LEDs, front panel monitor jack, or Artel s DigiLink Manager (DL Manager), which is an element management system (for more information, see the DigiLink Manager Setup and Operations Manual). This chapter contains the following additional major sections: Understanding and Using the DLC156M section on page 2 Understanding and Using the DLC156D section on page 13 DLC156 Function Modules Installation and Operations Manual 1

DLC156 Function Modules Understanding and Using the DLC156M This section, which describes how the DLC156M works and how to configure, install, and cable the module, contains the following topics: DLC156M Module Functional Description (page 2) Overview of the DLC156M Module (page 3) Configuring the DLC156M Module (page 5) Installing the DLC156 Module and XFP (page 8) Cabling the DLC156M Module (page 10) Monitoring the DLC156M Module Operation (page 10) Removing the XFP and DLC156 Module (page 12) DLC156M Module Functional Description This section provides a functional description of the DLC156M, including Figure 1, which is a functional block diagram of the module. Figure 1. DLC156M Module Functional Block Diagram Electrical Inputs and Outputs The DLC156M uses the following electrical inputs and outputs: Six rear panel BNC connectors for channels A to F inputs. 2 DLC156 Function Modules Installation and Operations Manual

Understanding and Using the DLC156M Backplane connectors for receiving inputs from other host chassis modules. Front-panel monitor jack, which is a 75 Ohm HD-BNC connector that allows you to monitor the input video signals on each channel. Optical Inputs and Outputs A single XFP socket provides the optical interface for outputting the aggregated optical signal. The XFP modules use LC connectors. Optical performance is dependant on the quality of your optical fiber and fiber interconnects, and on the selected XFP module, which must be specifically qualified by Artel. Consult Artel for available XFP options. Overview of the DLC156M Module This section provides an overview of the components that make up the DLC156M. Figure 2. DLC156M Module Major Components 8 9 10 1 2 5 6 7 3 4 11 DLC156 Function Modules Installation and Operations Manual 3

DLC156 Function Modules Table 1. DLC156M Elements Item DLC156M Element for details, see... 1 BNC channel connectors for receiving SD and HD video when used individually or SD, HD, and 3G when used as channel pairs as follows: A Paired with Channel B for 3G operation B C Paired with Channel D for 3G operation D E Paired with Channel F for 3G operation F 2 Rear panel BNC channel input status LEDs: STAT Input status indicator RATE Input rate indicator 3 XFP socket for the following optical connections: TX Transmits the aggregated video signal RX Receive (not used) 4 Rear panel module status LEDs: EMS Element management system indicator OK Alarm indicator Cabling the Video Input BNC Connections (page 10) Understanding the DLC156M Status LEDs (page 10) Cabling the XFP Connections (page 10) Understanding the DLC156M Status LEDs (page 10) 5 Rate selector switches SW1, SW2, and SW3. Configuring the DLC156M Module (page 5) 6 Channel enable DIP switch SW4. 7 Video alarm enable and EMS enable DIP switch SW5. 8 Front panel status LEDs: TX XFP transmit status indicator RATE A F BNC receive rate indicator OK Alarm indicator EMS Element management system indicator STATUS A F Channel status indicator 9 Front panel Channel Select switch Allows you to select the channel signal to monitor. Understanding the DLC156M Status LEDs (page 10) Using the DLC156M Monitor Jack (page 12) 10 Front panel monitor 75 Ohm HD-BNC output jack. 11 Backplane connector Provides power to the module, allows the module to share signals with other function modules, and is used for alarm and management signals. N/A 4 DLC156 Function Modules Installation and Operations Manual

Understanding and Using the DLC156M Configuring the DLC156M Module This section describes how to configure the operation of the DLC156M. You must configure the module while it is out of the chassis because the configuration switches are mounted to the top of the module printed circuit board. Artel ships the DLC156M configured to operate as follows: All six channels enabled No video detected alarm disabled EMS override enabled (DL Manager can change the DLC156M configuration) All 3G inputs disabled This section contains the following topics: Configuring the Video Rate with SW1, SW2, and SW3 (page 5) Enabling Channels with DIP Switch SW4 (page 6) Configuring Repeater and EMS Features with DIP Switch SW5 (page 7) Configuring the Video Rate with SW1, SW2, and SW3 Switches SW1, SW2, and SW3 enable or disable 3G video rate operation for each channel. Each switch controls the operation of a channel pair. For example, SW1 controls the operation of Channels A and B as follows: ON 3G video rate operation is disabled and Channels A and B can independently transmit SD or HD video. OFF 3G video rate operation is enabled and Channel A only can transmit SD, HD, or 3G video. Channel B is disabled. Figure 3. DLC156M Switches SW1, SW2, and SW3 Table 2 describes the switch SW1, SW2, and SW3 configuration options. The factory-set configuration settings are shown in bold type. DLC156 Function Modules Installation and Operations Manual 5

DLC156 Function Modules Table 2. DLC156M Switch SW1, SW2, and SW3 Settings Switch ON OFF SW1 Channels A and B support SD or HD. Channel A supports SD, HD, or 3G. Channel B is disabled. SW2 Channels C and D support SD or HD. Channel C supports SD, HD, or 3G. Channel D is disabled. SW3 Channels E and F support SD or HD. Channel E supports SD, HD, or 3G. Channel F is disabled. Enabling Channels with DIP Switch SW4 DIP Switch SW4 determines which video channels are enabled or disabled. Figure 4. DLC156M DIP Switch SW4 Table 3 describes the DIP switch SW4 configuration options. The factory-set configuration settings are shown in bold type. Note: All reserved switches must be left in the ON position. Table 3. DLC156M DIP Switch SW4 Settings Switch Channel ON OFF Switch Channel ON OFF S1 A Enabled Disabled S5 E Enabled Disabled S2 B Enabled Disabled S6 F Enabled Disabled S3 C Enabled Disabled S7 Reserved (leave ON) X S4 D Enabled Disabled S8 Reserved (leave ON) X 6 DLC156 Function Modules Installation and Operations Manual

Understanding and Using the DLC156M Configuring Repeater and EMS Features with DIP Switch SW5 DIP Switch SW5 enables or disables the video alarm and EMS functions. Figure 5. DLC156M DIP Switch SW5 Table 4 describes the DIP switch SW5 configuration options. The factory-set configuration settings are shown in bold type. Note: All reserved switches must be left in the ON position. Table 4. DIP Switch SW5 Settings Switch Function ON OFF S1 Reserved (leave ON) X S2 Reserved (leave ON) X S3 Video alarm No alarm. Loss of video on an enabled input causes a major alarm. S4 Reserved (leave ON) X S5 Reserved (leave ON) X S6 Reserved (leave ON) X S7 Reserved (leave ON) X S8 EMS Enable DL Manager can override the local switches. DL Manager cannot override the local switches. DLC156 Function Modules Installation and Operations Manual 7

DLC156 Function Modules Installing the DLC156 Module and XFP The DLC156 and associated XFP are hot swappable, enabling you to safely install them while power is applied to the host chassis. Before you install the DLC156, see the DLC156 data sheet for a detailed description of the module specifications including environmental requirements that you must adhere to when installing the module. Note: This procedure applies to the DLC156M and DLC156D modules, which are double-high function modules that require two host chassis slots each. To install the DLC156 in the host chassis (see Figure 6), perform the following steps: 1. From the back of the chassis, determine the two slots that the module is to occupy. 2. Remove the two screws that secure the blank trays to two of the unused function module slots (if necessary). Use any available function module slots. 3. Slide the DLC156 into the double-high chassis slot using the printed circuit board guide rails on either side of the slot. 4. Push the DLC156 in until it is firmly seated into the backplane and flush with the chassis. 5. Tighten the two mounting screws that secure the module to the chassis. Note: Failure to properly secure the DLC156 to the chassis with the two mounting screws can result in disconnecting the module from the backplane when you attach a cable to the monitor connector located on the front panel. 6. Install the Artel-approved XFP in the DLC156 with the handle on top as shown in Figure 6. Push the XFP into the socket located on the right side of the function module until it is firmly seated into the socket. Note: When you do not install an XFP, the TX LED located on the DLC156 front panel will flash. See Table 5 (DLC156M) or Table 9 (DLC156D) for other LED status indications. 7. Insert a blank tray in any unused chassis module slots to maintain proper ventilation. 8 DLC156 Function Modules Installation and Operations Manual

Understanding and Using the DLC156M Figure 6. DLC156 Module and XFP Installation DLC156 Module Mounting Screws (2) XFP (handle on top) Depending on the DLC156 model, proceed to one of the following sections: Cabling the DLC156M Module (page 10) Cabling the DLC156D Module (page 18) DLC156 Function Modules Installation and Operations Manual 9

DLC156 Function Modules Cabling the DLC156M Module The DLC156M can receive video network signals over BNC electrical cable connections (see Figure 7) and optionally from the backplane connector for channels E and F. The DLC156M transmits signals through an optical XFP. The cabling configuration that you use depends on your application. Figure 7. DLC156M BNC Connectors and XFP Socket Cabling the Video Input BNC Connections Use a high quality 75 Ohm precision video coax cable, such as Belden 1694A cable, when cabling to the DLC156M BNC connectors to the video source devices. Cabling the XFP Connections Use a single mode fiber when connecting to the LC connectors of the DLC156M XFP. To cable the optical connections, perform the following tasks: 1. Remove the XFP safety plug that protects the TX port. Cover the unused RX optical port to keep the port clean. 2. Connect the fiber optic cable between the XFP transmit optical connector (TX) on the DLC156M and the destination video device. Monitoring the DLC156M Module Operation This section describes how to monitor the DLC156M operations using the front and rear panel LEDs and the front panel monitor connector. This section contains the following topics: Understanding the DLC156M Status LEDs (page 10) Using the DLC156M Monitor Jack (page 12) Understanding the DLC156M Status LEDs Table 5 describes the different states of the DLC156M status LEDs as shown in Figure 8. 10 DLC156 Function Modules Installation and Operations Manual

Understanding and Using the DLC156M Figure 8. DLC156M Status LEDs and Monitor Connector Front Panel Rear Panel Table 5. DLC156M Front and Rear Panel Status LEDs LED Indicates... State Description OK DLC156M module status Off If power is applied to the system, an internal fault with the DLC156M may exist. Green Yellow Red Normal operation. Minor alarm condition exists. Major alarm condition exists. EMS DL Manager system status Off The module s configuration is controlled by the onboard configuration switches. Green The module s configuration has been set by DL Manager EMS. When green, the configuration switches have no effect on the module s operation. TX (front panel only) RATE A F XFP transmitter status Green Normal TX operation. Red (flashing) No XFP is installed or a transmitter fault exists. Channel input rate Off SD-SDI or ASI input signal detected. Green HD-SDI input signal detected. Yellow 3G-SDI input signal detected. DLC156 Function Modules Installation and Operations Manual 11

DLC156 Function Modules Table 5. DLC156M Front and Rear Panel Status LEDs (Continued) LED Indicates... State Description STATUS A F Channel input status Off Channel disabled. Green Video detected on channel. Yellow No video detected on channel. Red Input signal rate is outside the frequency range (+/-100 PPM). Red (flashing) 3G-SDI detected when 3G is not enabled. See the Configuring the Video Rate with SW1, SW2, and SW3 section on page 5 if needed. Using the DLC156M Monitor Jack You can monitor the video that the DLC156M receives by using the front panel monitor port and associated Channel Select push button switch. To connect a monitor the DLC156M to view the transmit and receive signals on Channels A and B, perform the following steps: 1. Connect the monitor cable between the monitor and the 75 Ohm HD-BNC monitor jack located on the DLC156M front panel (see Figure 8). 2. Push the CHANNEL SELECT button switch to sequentially monitor each channel s receive and transmit signals. When you push the switch, the selected signal s front panel LED blinks for 5 seconds to show which channel is being monitored. To advance to the next signal, push the switch again while it is blinking. Removing the XFP and DLC156 Module You can safely remove either the XFP from the DLC156 from the host chassis while power is applied to the module. Note: This procedure applies to the DLC156M and DLC156D modules. This section contains the following topics: Removing the XFP (page 12) Removing the DLC156 Module (page 13) Removing the XFP To remove the XFP from the DLC156, perform the following steps: 1. Remove the fiber optic cables from the XFP. 2. Pull down on the XFP handle to dislodge it from the DLC156. 3. Using the XFP handle, pull the XFP out of the module. 12 DLC156 Function Modules Installation and Operations Manual

Understanding and Using the DLC156D Removing the DLC156 Module To remove the DLC156 from the host chassis, perform the following steps: 1. Remove the fiber optic cables from the XFP. 2. Remove the coaxial cables from the BNC connectors. 3. Loosen the two mounting screws that secure the DLC156 to the host chassis. 4. Using the two mounting screws, pull the DLC156 out of the host chassis. Caution To avoid problems associated with overheating, do not leave a function module slot open when power is applied to the chassis. Every module slot must contain a module or blank tray to ensure proper ventilation when power is applied. Understanding and Using the DLC156D This section, which describes how the DLC156D works and how to configure, install, and cable the module, contains the following topics: DLC156D Module Functional Description (page 13) Overview of the DLC156D Module (page 15) Configuring the DLC156D (page 16) Installing the DLC156D Module and XFP (page 18) Cabling the DLC156D Module (page 18) Monitoring the DLC156D Module Operation (page 19) Removing the XFP and DLC156D Module (page 21) DLC156D Module Functional Description This section provides a functional description of the DLC156D, including Figure 9, which is a functional block diagram of the module. DLC156 Function Modules Installation and Operations Manual 13

DLC156 Function Modules Figure 9. DLC156D Module Functional Block Diagram Electrical Outputs The DLC156D uses the following electrical outputs: Six rear panel BNC connectors for channels A to F outputs. Backplane connector for transmitting outputs to other host chassis modules. Front-panel monitor jack, which is a 75 Ohm HD-BNC connector that allows you to monitor the output video signals on each channel. Optical Inputs and Outputs A single XFP socket provides the DLC156D optical interface that receives the aggregated video signal. When configured to operate as a repeater, the XFP transmits the reclocked aggregated video signal. The XFP modules use LC connectors. Optical performance is dependant on the quality of your optical fiber and fiber interconnects, and on the selected XFP module, which must be specifically qualified by Artel. Consult Artel for available XFP options. 14 DLC156 Function Modules Installation and Operations Manual

Understanding and Using the DLC156D Overview of the DLC156D Module This section provides an overview of the components that make up the DLC156D. Figure 10. DLC156D Module Major Components 7 8 9 1 2 5 6 3 4 10 Table 6. DLC156D Elements Item DLC156D Element for details, see... 1 BNC channel connectors for transmitting SD and HD video when used individually or SD, HD, and 3G when used as channel pairs as follows: A Paired with Channel B for 3G operation B C Paired with Channel D for 3G operation D E Paired with Channel F for 3G operation F Cabling the Video Output BNC Connections (page 19) DLC156 Function Modules Installation and Operations Manual 15

DLC156 Function Modules Table 6. DLC156D Elements (Continued) Item DLC156D Element for details, see... 2 Rear panel BNC channel transmit status LEDs: STAT Output status indicator RATE Output rate indicator 3 XFP socket for the following optical connections: TX Transmit RX Receive 4 Rear panel module status LEDs: EMS Element management system indicator OK Alarm indicator Understanding the DLC156D Status LEDs (page 19) Cabling the XFP Connections (page 19) Understanding the DLC156D Status LEDs (page 19) 5 Channel enable DIP switch SW4. Configuring the DLC156D (page 16) 6 Video alarm, optical repeater function, and EMS enable DIP switch SW5. 7 Front panel status LEDs: TX XFP transmit status indicator RX XFP receive status indicator RX ERR Receive error indicator RATE A F BNC receive rate indicator OK Alarm indicator EMS Element management system indicator STATUS A F Channel status indicator 8 Front panel Channel Select switch Allows you to select the channel signal to monitor. Understanding the DLC156D Status LEDs (page 19) Using the DLC156D Monitor Jack (page 21) 9 Front panel monitor 75 Ohm HD-BNC output jack. 10 Backplane connector Provides power to the module, allows the module to share signals with other function modules, and is used for alarm and management signals. N/A Configuring the DLC156D This section describes how to configure the operation of the DLC156D. You must configure the module while it is out of the chassis because the configuration DIP switches SW1 and SW2 are mounted to the top of the module printed circuit board. Artel ships the DLC156D configured to operate as follows: All six channels enabled Optical transmit (TX) disabled Optical receive (RX) enabled 16 DLC156 Function Modules Installation and Operations Manual

Understanding and Using the DLC156D Alarm for loss of video is disabled EMS override enabled (DL Manager can change the DLC156D configuration) This section contains the following topics: Enabling Channels with Switch SW1 (page 17) Enabling Video Alarm, Optical Repeater, and EMS with DIP Switch SW2 (page 17) Enabling Channels with Switch SW1 DIP Switch SW1 determines which video channels are enabled or disabled. Figure 11. DLC156D DIP Switch SW1 Table 7 describes the DIP switch SW1 configuration options. The factory-set configuration settings are shown in bold type. Note: All reserved switches must be left in the ON position. Table 7. DIP Switch SW1 Settings Switch Channel ON OFF Switch Channel ON OFF S1 A Enabled Disabled S5 E Enabled Disabled S2 B Enabled Disabled S6 F Enabled Disabled S3 C Enabled Disabled S7 Reserved (leave ON) X S4 D Enabled Disabled S8 Reserved (leave ON) X Enabling Video Alarm, Optical Repeater, and EMS with DIP Switch SW2 DIP Switch SW2 enables or disables the video alarm, optical repeater function, and EMS function. Note: All reserved switches must be left in the ON position. DLC156 Function Modules Installation and Operations Manual 17

DLC156 Function Modules Figure 12. DLC156D DIP Switch SW2 Table 8 describes the DIP switch SW2 configuration options. The factory-set configuration settings are shown in bold type. Table 8. DIP Switch SW2 Settings Switch Function ON OFF S1 Reserved (leave ON) X S2 Reserved (leave ON) X S3 Video alarm No alarm. Loss of video on an enabled input causes a major alarm. S4 Repeater mode disabled Repeater mode is disabled. TX laser is off. Repeater mode is enabled. TX laser is on. S5 Reserved (leave ON) X S6 Reserved (leave ON) X S7 Reserved (leave ON) X S8 EMS Enable DL Manager can override the local switches. DL Manager cannot override the local switches. Installing the DLC156D Module and XFP Installation of the DLC156D is the same as installing the DLC156M as described in the Installing the DLC156 Module and XFP section on page 8. Cabling the DLC156D Module The DLC156D receives optical video signals through an XFP and transmits electrical video signals over BNC cable connections (see Figure 13). The cabling configuration that you use depends on your application. 18 DLC156 Function Modules Installation and Operations Manual

Understanding and Using the DLC156D Figure 13. DLC156D BNC Connectors and XFP Socket Cabling the Video Output BNC Connections Use a high quality 75 Ohm precision video coax cable, such as Belden 1694A cable, when cabling to the DLC156D BNC connectors to the destination devices. Cabling the XFP Connections Use a single mode fiber when connecting to the LC connectors of the DLC156D XFP. To cable the optical connections, perform the following tasks: 1. Remove the XFP safety plug that protects the RX and TX ports. If you are not using the optical repeater function, cover the unused TX optical port to keep the port clean. 2. Connect the fiber optic cable between the XFP receive optical connector (RX) on the DLC156D and the source device. If you are using the optical repeater function, connect the fiber optic cable between the XFP transmit optical connector (RX) on the DLC156D and the destination device. Monitoring the DLC156D Module Operation This section describes how to monitor the DLC156D operations using the front and rear panel LEDs and the front panel monitor connector. This section contains the following topics: Understanding the DLC156D Status LEDs (page 19) Using the DLC156D Monitor Jack (page 21) Understanding the DLC156D Status LEDs Table 9 describes the different states of the DLC156D status LEDs as shown in Figure 14. DLC156 Function Modules Installation and Operations Manual 19

DLC156 Function Modules Figure 14. DLC156D Status LEDs and Monitor Connector Front Panel Rear Panel Table 9. DLC156D Front and Rear Panel Status LEDs LED Indicates... State Description OK DLC156D module status Off If power is applied to the system, an internal fault with the DLC156D may exist. Green Yellow Red Normal operation. Minor alarm condition exists. Major alarm condition exists. EMS DL Manager system status Off The module s configuration is controlled by the onboard configuration switches. Green The module s configuration has been set by DL Manager EMS. When green, the configuration switches have no effect on the module s operation. TX (front panel only) XFP transmitter status Off Repeater is disabled; laser is off. Green Green (flashing) Red (flashing) Normal repeater operation; TX is enabled. Locked to 10 Gig Ethernet and repeating Video outputs disabled No XFP is installed or a transmitter fault exists. 20 DLC156 Function Modules Installation and Operations Manual

Understanding and Using the DLC156D Table 9. DLC156D Front and Rear Panel Status LEDs (Continued) LED Indicates... State Description RX XFP receiver status Green Normal operation. Yellow Red High receiver power. No XFP installed or an invalid input signal detected. RX ERR Receive errors Off No optical errors detected. Green (flashing) Yellow (flashing) Error detected and corrected. Error detected and corrected; high error rate warning. Red Error detected that could not be corrected. RATE A F Channel input rate Off SD-SDI or ASI input signal detected. Green HD-SDI input signal detected. Yellow 3G-SDI input signal detected. STATUS A F Channel input status Off Channel disabled. Green Video detected on channel. Yellow No video detected on channel. Red Input signal rate is outside the frequency range (+/-100 PPM). Red (flashing) 3G-SDI signal blocked at source (DLC156M). Using the DLC156D Monitor Jack You can monitor the video that the DLC156D transmits out the BNC connectors by using the front panel monitor port and associated Channel Select push button switch. To connect a monitor the DLC156D to view the transmit signals of a selected channel, perform the following steps: 1. Connect the monitor cable between the monitor and the 75 Ohm HD-BNC monitor jack located on the DLC156D front panel (see Figure 14). 2. Push the CHANNEL SELECT button switch to sequentially monitor each channel s receive signals. When you push the switch, the selected signal s front panel LED blinks for 5 seconds to show which channel is being monitored. To advance to the next signal, push the switch again while it is blinking. Removing the XFP and DLC156D Module Removing the DLC156M module or XFP is the same as removing the DLC156M as described in the Removing the XFP and DLC156 Module section on page 12. DLC156 Function Modules Installation and Operations Manual 21

22 DLC156 Function Modules Installation and Operations Manual

Index A audience ix B backplane connector DLC156D 16 DLC156M 4 block diagram DLC156D 13 DLC156M 2 BNC connectors DLC156D 15 DLC156M 4 C cable interfaces DLC156D 18 DLC156M 10 caution definition x Channel Select switch DLC156D 16 DLC156M 4 conventions x Customer Service x E e-mail address, Customer Service x F functional description DLC156D 13 DLC156M 2 L LEDs front panel DLC156D 16 DLC156M 4 rear panel DLC156D 16 DLC156M 4 M module cable DLC156D 18 DLC156M 10 components DLC156D 15 DLC156M 3 install DLC156 8 remove DLC156 12 monitor jack DLC156D 21 DLC156M 12 monitor operations DLC156D 19 DLC156M 10 monitor output jack DLC156D 16 DLC156M 4 O operations, monitor DLC156D 19 DLC156M 10 R related documentation ix return authorization (RA) number x S shipment, damaged x status LEDs DLC156D 19 DLC156M 10 symbols x W warning definition x X XFP cable DLC156D 19 DLC156M 10 socket DLC156D 16 DLC156M 4 DLC156 Function Modules Installation and Operations Manual Index-1

Index Index-2 DLC156 Function Modules Installation and Operations Manual

Proven Products, Unrivaled Service, and Great Support Proven technology in a rugged, reliable package Supports all formats across all networks Intuitive and simplified user interfaces Integrated, modular, and flexible Compact and low power Off-the-shelf delivery Network requirements analysis and design services Training and installation support available 24x7x365 technical support available Artel Video Systems Corp. 5B Lyberty Way, Westford, MA 01886 USA T: 978-263-5775 F: 978-263-9755 Sales: sales@artel.com Technical Support: customercare@artel.com www.artel.com All specifications subject to change without notice. 2017