MULTIS L72. Operating instructions

Similar documents
MULTIS LMp / LMg. Systèmes de Coupure et de Protection Switching and Protection Systems

DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL

USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements

Time-Lag Relays. User s Handbook (General Model)

AS09..S 3-pole Contactors - Spring Terminals

02/11/2015

multi-function meters

Style 5S Clock / Timer

Actuators IC 20, IC 40

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Electronic converter for level transmitters MT03L Instructions manual

Operating Manual RISH OPTIMA VAF

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Datasheet - SRB301LC 24VAC/DC

Ordering details. Approval. Classification

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Datasheet - SRB-E-201ST

Series CT7N Bimetallic Overload Relays

Kuhnke Technical Data. Contact Details

Operating instructions Electronic preset counter Type series 717

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

IP Roombox. Hotel Room Management

Multifunction Digital Timer

A V 50Hz / V 60Hz

LED Driver Linear / area fixed output

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

MT03A Electronic converter for flow rate transmitters

G 400 CURRENT GENERATOR. programmable, ± points. User handbook Valid for instruments with version 01.xx

LW10-T600. P10 Led Wall Display

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Standard RS232 RS ma

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Modular pulse operated latching relay 16 A

VAT 20 Adjustable Frequency Drive

LED Driver Compact fixed output

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Operating instructions

LED MODULES READYLINE DL

POWER MONITORS ENERIUM RANGE. Minimize your energy consumption and optimize your installation

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Type: DILM25 10(24V50HZ) Article No.:

I/A Series Hardware Fiber Optic LAN Converter

LED control gear Compact fixed output

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

LED Driver Compact fixed output

PRINCIPLES AND APPLICATIONS

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Rack mounted telephone- and leased line modem for industrial applications

Type: DILM12 10(24VDC) Article No.:

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

SQM40/41 Actuators for air and gas dampers

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

PQ-Box 100 Quick Start Instructions

Process transmitter RMA422

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

PowerLogic power-monitoring units

FOREST SHUTTLE S / L / M RECEIVER

Inductive sensor BI1.5-EG08K-Y1

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Type SCH94FO. Type SCH94FO. Description

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

Single-phase bidirectional energy meter with S0 pulse output

Standard signal metering in wall-mounting case

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

19 / 20.1 / 22 WIDE SCREEN TFT-LCD MONITOR

Operating Instructions

Certificate of Calibration

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LED Driver Compact fixed output

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features:

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

REGO Start&Go USER MANUAL

SAUTER flexotron RDT405 Manual

Transcription:

GB MULTIS L72 Operating instructions

2 SOCOMEC - Ref. : 876 091B

ENGLISH GB Contents PRELIMINARY OPERATIONS 4 GENERAL INFORMATION 5 PRESENTATION 4 INSTALLATION 5 Mechanical environment Climatic environment Safety instructions Connections to the network PROGRAMMING 6 OPERATION 8 Display Keys TECHNICAL CHARACTERISTICS 9 SOCOMEC - Ref. : 876 091B 3

PRELIMINARY OPERATIONS For the safety of personnel and equipment, it is essential that you read these instructions carefully before use and familiarise yourself fully with their contents. When you receive the package, check that: the packaging is in good condition, the product has not been damaged during transit, the reference number of the device conforms to your order, the package contains the product as well as the operating instructions. GENERAL INFORMATION The Multis L72 is a digital LV threephase measuring device. It displays instant average or maximum values for voltages and currents. It is supplied in a flush-type switch body enclosure 72 x 72 x 83 with a display consisting of 3 lines of 4 LED displays, so that the 3 phases can be viewed simultaneously. In addition to these values, for monitoring generator set or transformer feeders, as well as the previous values, it can display frequency, max. values and hour run metering. This product can be configured (winding ratio and integration period of the max. I) by programming. It is compatible with all electrical networks (single-phase, two-phase, three-phase, three-phase + neutral). The device is self-powered or can run on an external power source depending on the wiring chosen. TYPE Multis L72 M instant U + V + I + Io + F + h Measurement AVG average Umoy, Vmoy, Imoy MAX maximum Umax, Imax, Iomax Product reference 192 J 8100 PRESENTATION The Multis L72 multi-indicator comprises a 3 x 4-digit and 3 display, programming and reset keys as well as signalling LEDs. LED display Display LEDs Display and programming keypad MULTI 047 A 1 3 2 4 SOCOMEC - Ref. : 876 091B

INSTALLATION MECHANICAL ENVIRONMENT Recommendations: avoid proximity with systems that generate electromagnetic disturbances, avoid vibrations including accelerations of more than 1 G for frequencies of less than 60 Hz. To install the device correctly, it is necessary to respect the cut-out plan below. 68 + 0,7-0,0 72 68 + 0,7-0,0 ENGLISH 63 11 MULTI 038 A 72 CLIMATIC ENVIRONMENT To guarantee optimum operation, it is recommended that this device be used within a temperature range of - 10 C to + 50 C with maximum relative humidity between 20 and 95% inclusive. The device can operate at temperatures as low as -15 C SAFETY INSTRUCTIONS To avoid damage to the device and to guarantee its correct operation, please, ensure before connecting it, that the following points are respected: the indications on the enclosure, the frequency of the network: 50 or 60 Hz, maximum current of 6 A, voltage of 230 V AC or 400 V AC ± 20 %, do not earth the point of common coupling of the current inputs. NB: The maximum tightening torque for each screw is 0.4 Nm. CONNECTIONS TO THE NETWORK Do not connect the CT secondary to the earth Single phase network 3-wire three-phase network 4-wire three-phase network I1 I2 I3 S1 S2 S1 S2 S1 S2 1 3 5 7 9 11 N L1 L2 L3 10 12 14 2 4 6 8 I1 I2 I3 S1 S2 S1 S2 S1 S2 1 3 5 7 9 11 N L1 L2 L3 10 12 14 2 4 6 8 I1 I2 I3 S1 S2 S1 S2 S1 S2 1 3 5 7 9 11 N L1 L2 L3 10 12 14 2 4 6 8 0 230V Aux. supply 1 0 400V 230V Aux. supply 1 0 400V 230V Aux. supply 1 L1 (R) L2 (S) L3 (T) L1 (R) L2 (S) L3 (T) L1 (R) L2 (S) L3 (T) N N MULTI 044 A 1 Fuses 0.5 A MULTI 045 A 1 Fuses 0.5 A MULTI 046 A 1 Fuses 0.5 A SOCOMEC - Ref. : 876 091B 5

PROGRAMMING 1 ENTER PROGRAMMING MODE KEY INSTRUCTIONS MESSAGE and Press on both keys at the same time for 3 seconds. NB: it is necessary to enter a secret code 100 to be able to programme this device, proceeding as follows: The key is used to increment a digit or scroll a list of choices. The key is used to change digit or validate and change menu. 2 codes are set: Installer code: Allows access to the electrical configuration of the Multis L72 (network, CT, integration time). By default, it is set at 100 It is possible to modify it after the administrator code is entered. Administrator code: The administrator code is set at and equal to 312. This code allows access to the modification of the installer code (no access to the electrical configurations). On the 1st and 2nd lines cod and mod are displayed respectively. The 3rd line being used for the modification of the installer code (312 being of course forbidden as it is used as the administrator code ). After entering the installer code: 2 PROGRAMMING OF THE TYPE OF NETWORK (net) 1st display: 3rd display: net (Network) type of network for the choice of network to validate the network chosen 1L = single phase (phase to neutral connection) 2L = two phase (phase to phase connection) 3L = three phase (3 phase connection) 4L = three phase (3 phase + neutral connection) 3 PROGRAMMING OF THE CT RATIO (Ct) 1st display: 3rd display: Ct (Current transformer) CT primary to choose the value of the primary of the CTs. to validate the primary chosen The CT rating values are standardised: 5, 10, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 125, 150, 160, 200, 250, 300, 400, 500, 600, 750, 800, 1000, 1200, 1250, 1500, 1600, 2000, 2500, 3000, 4000, 5000, 6000, 7500, 8000. 6 SOCOMEC - Ref. : 876 091B

PROGRAMMING (continued) 4 PROGRAMMING THE INTEGRATION TIME FOR THE MAXIMUM CURRENTS 1st display: 3rd display: It (Integration time) value of the integration time to choose the value of the integration time to validate the value chosen The integration time values are pre-programmed: 5, 8, 10, 15, 30, 60, 120. 5 TO EXIT PROGRAMMING MODE to make your choice to validate your choice Ce menu permet de quitter la configuration avec ou sans sauvegarde. ENGLISH Choice: { QUIT (1st display) NO (3rd display) Return to the 1st menu Programming of the type of network { QUIT (1st display) SAVE (3rd display) Saves the configuration programmed and quits configuration mode. { QUIT (1st display) NO (2nd display) SAVE (3rd display) Quits configuration mode without saving. SOCOMEC - Ref. : 876 091B 7

OPERATION DISPLAY LED display: 3-line, 4-digit, 7-segment display. Measured values indicator LED. LEDs indicating type of value: average value AVG, maximum value MAX. MULTI 048 A 1 3 4 5 6 2 KEYS The device has 3 keys: - Key : successive pressing on this key, M, allows the selection of the instant values measured. Thanks to sampling, the Multis L72 displays TRMS values up to number 15. The values displayed are refreshed every 500 ms. The choice of measurement is indicated by LEDs. - Key : allows the selection of the type of values required : In average mode (key AVG), U I F or V I F are displayed simultaneously. These values are instant averages of the 3 phases. MAX : value max of U, I or In (led ). The Max values (key Max), are the maximum measurements over an integrated period (5 to 120 ) for currents, and the maximum instant value for voltages (L-L, L-N or single-phase). - Key (max = 0) to reset the Max values after pressing for at least 3 seconds. Resetting to zero can be done whilst the max. value in question is displayed. 8 SOCOMEC - Ref. : 876 091B

TECHNICAL CHARACTERISTICS ENCLOSURE Connection using tunnel terminals Rigid wires up to 2.5 mm 2 / Flexible wires up to 2.5 mm 2 Weight: 250 gr Dimensions: Flush-type: l x h x p = 72 x 72 x 83 DISPLAY 3 lines, 4 digits, 7 segments / refreshment 0.5 sec. Size of digits: 10 x 6 mm Display unit / range of measurement: TRMS measurement up to harmonics number 15 Current (according to CT): 0.1 A: 3-digit display for values < 100 A 0.5 A: 4-digit display for values < 1000 A 5 A: 4-digit display for values < 10 000 A Voltage: 1 V Hour metering: 0.1 h (incrementation if U12 > 35 V) 999 999.9 Frequency: 0,1 Hz / measured on phase 1 40.0 at 80.0 Hz Protection index (front panel): IP54 ENGLISH INPUTS CURRENT From a current transformer with: Configurable primary: Secondary: Measurement range: Consumption: Inputs: Overload: VOLTAGE Measurement range: Consumption: AUXILIARY SUPPLY 5 to 8000 A 5 A non-insulated permanent at 1,2 In / (3h) at 2 In / (1 ) at 5 In / (1 ) at 10 In Terminals 10 and 12: 230 VAC ± 20 % Terminals 10 and 14: 400 VAC ± 20 % Possibility of self-supply by external wiring between U aux and the voltage inputs Consumption: secondary from 0.1 to 6 A at In 0.5 VA 35 V at 480 V (L-L) 0.5 VA 2.5 VA ACCURACY Accuracy index: Voltage, current 0,5 % ± 1 digit from 45 to 65 Hz Frequency ± 0,2 Hz for the frequency OPERATING CONDITIONS Operating temperature: -15 to +50 C Storage temperature: -20 to +70 C Relative humidity: 95 % STANDARDS Category of measurement Relating to CE marking:iec 61000-4-2 electrostatic discharge (Air 8kv, contact 4 kv) IEC 61000-4-3 electromagnetic radiation (10v/m) IEC 61000-4-4/5/6/8/11 EN 50081-1 EN 50081-2 Relating to operating conditions: IEC 68-2-11/30 Subject to technical modifications and availability III SOCOMEC - Ref. : 876 091B 9

SOCOMEC - Réf. : 876 091 A - 12/03 HEAD OFFICE SOCOMEC GROUP Switchgear and UPS S.A. capital de 10 836 000 R.C. Strasbourg 5484500 149 B SOCOMEC 1, rue de Westhouse - B.P. 10 F - 67235 Benfeld Cedex - FRANCE Tel. +33 (0)3 88 57 41 41 - Fax +33 (0)3 88 57 78 78 SALES MANAGEMENT DIVISION SOCOMEC 95, rue Pierre Grange F - 94132 Fontenay-sous-Bois Cedex - FRAN- CE Tel. +33 (0)1 45 14 63 40 - Fax +33 (0)1 48 77 31 12 scp.dcm@socomec.com Industrial Switching & Protection Systems www.socomec.com This document is not contractual. SOCOMEC reserves the right to modify features without prior notice in view of continued improvements.