The Mannie Manim Technical Specifications

Similar documents
Barney Simon Theatre Technical Specifications

Market Theatre The John Kani Theatre Technical Specifications

Matt Dann Cultural Centre

DEREHAM MEMORIAL HALL

THE STREET THEATRE. Technical Specifications

JERWOOD VANBRUGH THEATRE

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

New Theatre Royal Lincoln Technical Information

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Technical Data Sheet

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

TECHNICAL SPECIFICATIONS

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

2017 TECHNICAL SPECIFICATIONS

Technical Pack. Attenborough Arts Centre

Sandusky State Theatre Technical Specifications

Latrobe Performing Arts Centre

Theatre Technical Specifications

Technical Information

Technical Specifications

CHELSEA THEATRE. Technical Specifications

CENTRE FOR PERFORMING ARTS

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Main Stage Technical Specs - Hall #2

RPAC REDLANDS PERFORMING ARTS CENTRE

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

FASO DANCE COMPANY KALAKUTA REPUBLIK

Technical Specification

Queensland Performing Arts Centre

Technical requirements & conditions for hirers

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Pleasance London Main House Visiting Company Information Pack May 2017

Main House Technical Specifications

Technical Specifications

The Haymarket Basingstoke Technical Specifications

Technical Specification Pavilion Dance

Main House Technical Specification

Studio 180. Electronic and Print versions of the venue ground plan are available from the Technical Director.

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

The Georgian Theatre Royal Technical Information For Visiting Companies

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Hopgood Theatre NOARLUNGA CENTRE

Technical Information

SHUBERT THEATER 247 College Street, New Haven, CT

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

ISLAND HALL TECHNICAL INFORMATION

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

COURTYARD!!!!! THEATRE

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

Technical Specifications. Taylor Little Theater

Technical Specifications Updated 01/10/2017. Stage

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Facility Information

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

2012 HSC Entertainment Industry Sample Answers

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Shouson Theatre Venue Specifications (updated Jan 2017)

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

SAINT ANSELM COLLEGE DANA CENTER

Technical Specifications

TOWER THEATRE TECHNICAL INFORMATION & GENERAL SPECIFICATIONS 2014 PLEASE DIRECT ALL ENQUIRIES TO THE OPERATIONS MANAGER:

The Standard Bank Studio is a music venue made from the choir stalls and the stage of the Cape Town City Hall Auditorium. It

Downtown Arts Center Tech Packet. General Information

AKI STUDIO THEATRE Information and Technical Specifications

INFORMATION FOR VISITING COMPANIES

JANE RUTTER AUSTRALIA S FIRST LADY OF THE FLUTE

Technical Information

Source 4 Junior Zoom Profile 575W 14 part of universal rig

HIRE AND TECHNICAL INFORMATION

Technical Specifications

Technical Specifications and Inventory Spring 2018

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

Avant Garde Dance & The Place Fagin s Twist Tech Spec 2016

Darlington Hippodrome Technical Specification

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

The set is very simple. It consists of one small box, a small stool, and a small ping- pong table.

The Lantern Technical Information

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Dr JOHN GALLAGHER CONCERT CHAMBER

TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE

John Leslie Theatre. Technical Specifications. Updated July 2018

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

TECHNICAL SPECIFICATIONS: STICKS STONES BROKEN BONES Company: Bunk Puppets, contact :Jeff Achtem,

Technical Specification

Technical Specifications

Transcription:

The Mannie Manim Technical Specifications 1

TECHNICAL CONTACTS Hailey Kingston Production Manager +27 72 236 5978 haileyk@markettheatre.co.za Thapelo Mokgosi Production Manager/Lighting Designer +27 82 873 7661 thapelom@markettheatre.co.za Motlalepule Makhate Senior Stage Manager +27 82 678 0867 motlalepulem@markettheatre.co.za Nomvula Molepo Head of Lighting +27 82 549 5129 nomvulam@markettheatre.co.za Thuli Mbuli Senior Front of House Manager +27 74 158 4014 thulim@markettheatre.co.za Mavis Nengovhela Front of House Manager +27 82 385 9095 mavisn@markettheatre.co.za 2

STAGE STAGE DIMENSIONS END ON Width wall to wall lower level 10138mm Perimeter Width balcony to balcony upper level 8338mm Depth back wall to first row of seats 6862mm Width of Upper level balcony back wall to fence 1094mm Height Floor to balcony 2593mm Height Floor to grid 5935mm Height Balcony to grid 3108mm Height Balcony width on 1 st level 850mm Back wall- there are 4 ventilation panels on the back wall, these cannot be covered as it prevents circulation in the theatre and trips the aircon. If you require a backdrop in the end on position it is advised to a gauze or permeable material. THRUST Width 6749mm Depth Underneath the balcony to first row 6251mm Balcony width 850mm Depth from edge of balcony to first row 6521mm Height: Floor to balcony 2593mm Height: Floor to grid 5935mm Height Balcony to grid 3108mm 4 rows of seating 155 seats 4 emergency exits The thrust configuration takes 3 days to turnaround Passage leading to dressing room is an emergency exit. FLY SYSTEM The Mannie Manim DOES NOT have a fly system. Legs, Borders and Set are dead hung directly from the Mannie Manim Theatre Grid. All rigging requirements must be advanced with the theatre prior to load in. 3

BALCONY Underneath the balcony on 1 st level we have a sprinkler system. No smoke machines allowed directly underneath the balcony area, as we may trigger the smoke alarm. SOFT GOODS Black Curtain Surround No borders No Legs PIANO (Tunings and Piano moving will be charged to the incoming productions and Dependent of availability) Weimar Baby Grand Piano Yamaha Upright piano STAGE ACCESSORIES Various Standard Stock rostra 1000 x 2440 Adjustable legs - height intervals of 300, 450, 600 and 900 Stairs can be made available for rostra Images of rostra and adjustable legs can be provided Cladding for rostra can be provided if required Podium (depending on availability) FACILITY STAFFING The Market theatre will provide the following staff for incoming productions: Production Manager (set up and strike only) Stage Manager Technical Coordinator (set up and strike only) Lighting Technician (At a cost) Laundry Mistress (Day time hours only) 4

SEATING CAPACITY END ON Auditorium: 155 END ON THRUST Auditorium: 155 LOADING DOCK There is a loading lock, doors open directly onto stage. PARKING There is a parking for a 10ton Truck for offloading only Parking will be provided in the FNB Parking lot, cnr Miriam Makeba Str and Jeppe Street. DRESSING ROOMS Dressing Room A Cupboards 1 Basin Plug Points 6 Stations with mirrors Dress Rail Dressing Room B 6 Stations with mirrors Plug Points Cupboards Dress Rail LAUNDRY Wardrobe Room: located in the Production office. 2 Speed Queen Washing Machine 2 Driers 1 Steamer 2 Irons and Ironing Boards Wardrobe requirements must be advanced with the theatre prior to Load in. 5

EQUIPMENT HOUSE LIGHTING PLOT The Mannie Manim Theatre has a fixed grid, from which lights are hung. The grid formation- Only a PDF plan to be supplied House Light- are 6 LED LIGHTING EQUIPMENT IN THE LAAGER THEATRE: Profiles Make Model Angle Detail/Accessories Wattage Quantity Strand Quartet 22/40 Gel frame, Shutters 650 24 Strand Quartet 15/25 Gel frame, Shutters 650 12 Fresnel s Make Model Angle Detail/Accessories Wattage Quantity Strand Quartet F 10/40* Gel frame,4 Leaf 650 24 rotatable barndoors Strand Cantata F Gelframe,4 Leaf rotatable barndoors 1000 18 Par Cans Make Model Angle Detail/Accessories Wattage Quantity Toshiba Classic Pro CP60, CP61,CP62 Gel frame 1000 6 Birdies Gel frame 50w 8 Accessories Item Size Quantity Gobo Holder M-Size 8 DIMMERS Total Dimmers 96 x 3k ETC sensor Dimmer Rack. Control Desk GrandMA2 Ultra-Light Dimmer Locations In the theatre upstairs in an allocated space. HOUSE LIGHTS Control Controlled on a desk as well as manually Control Positions In a control area upstairs, position is decided by the configuration of the performance area. 6

6 LED Lights in total Able to change rig to accommodate the seating configuration CHANNEL 100, 101 104 and 105 ARE USED FOR HOUSE LIGHTS COLOUR MEDIA AND COLOURS Gel and Gobos inventory is constantly changing. Market Theatre stock predominantly LEE colours Please contact the Head of Lighting and Production Manager to check availability Any additional gel or gobos that must be purchased for clients will be charged back at applicable rates. SOUND EQUIPMENT MIXING SYSTEM O1v 96 16 Channel Yamaha Digital Console FRONT OF HOUSE PA SYSTEM 2 x EV ZLX12 Speakers L+R 2 x QS 350 Quest speakers (Delays) 3 x PS8 Speakers (Delays) 2 x JBL Subs SYSTEM DRIVER 2 x QA1000 Quest Amplifiers 1 x Camco Tecton 24.4 Amplifier w/ Processor 1 x 31 band Graphic Equalizer CD PLAYER 1 x Denon D4500 Dual CD Player BACKLINE Subject to availability MICROPHONES Subject to availability 7

COMMUNICATION PACKS Subject to availability VIDEO EQUIPMENT Subject to availability from the John Kani Theatre HEALTH AND SAFETY SECURITY ACCESS CONTROL- Market Theatre has a Sign In policy as you enter the building. In coming productions to advance a list of names to FOH and Stage Manger for sign in purposes. 1 Security guard is provided during the day and 4 security guards at night. Personal items left in the dressing rooms and auditorium are done so at your own risk Smoking is prohibited in the theatre. Shows requiring open flames or smoke need to inform the production manager in advance. CLEANERS The theatre and dressing rooms will be cleaned every morning, daily. Cleaners are in the building from 08:30-16:00 daily. ACCESS The Theatre is open 7 days a week. There are no performances on Monday, work can continue as normal between 9h00-17h00, unless otherwise arranged by the production manager at the Market Theatre. SAFETY Stage Managers at the Market Theatre are Health and Safety representatives during the production. Stage Managers will brief incoming productions on arrival of Health and Safety regulations at the Market Theatre. Health and Safety matters can also be raised with FOH and the Production Department. Visiting technical crew are not to work on the grid without safety gear and without a Market Theatre Technical Staff member in the venue. 8

The Market Theatre Production Manager and Head of Lighting will provide ground plans and lighting plans on request.. 9