Capacitors and banks 50 Hz 0 400/415 V network voltage

Similar documents
MIKRO POWER FACTOR CORRECTION COMPONENTS

02/11/2015

POWER FACTOR CORRECTION

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Gamma instabus. Technical product information

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

LED control gear Compact fixed output

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

LED Driver Compact fixed output

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Series CT7N Bimetallic Overload Relays

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Type: DILM25 10(24V50HZ) Article No.:

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

LED Driver Compact fixed output

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Type: DILM12 10(24VDC) Article No.:

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Power Factor Correction Power Quality Solutions

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Power Quality Solutions

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Modular Power System acc. VG MoFess Module for Military Ground Vehicles

LED Driver Compact dimming

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Product Range Power Supplies

PRINCIPLES AND APPLICATIONS

GV2ME. Main. Device short name. Device application

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Catalogue Ignitors and power switches for HID

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Power Factor Correction Power Quality Solutions

Interface Relays and Optocouplers Product group picture

LED Driver Linear / area fixed output

Magnecraft Power Relays

AS09..S 3-pole Contactors - Spring Terminals

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

GV2ME. Main. Device short name. Device application

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Pluggable interface relays CR-M Miniature relays

Magnetic and Hydraulic-Magnetic Circuit Breaker

GV2P05. Main. Device short name. Device application

R.2. Power capacitors, LV. Power factor correction and harmonic filtering. Homepage : Circutor-NRW Büro Köln

GR circuit breaker - hydraulic magnetic, Datasheet

Minicontactorrelay,2NO/2NC,DCoperated

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

A V 50Hz / V 60Hz

Process Transmitter RMA 422

Modular pulse operated latching relay 16 A

POWER FACTOR REGULATOR

Indoor Linear 80W Driver SI-C215280N2KR

Film Capacitors Power Factor Correction

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Process transmitter RMA422

Product Data Sheet 8506 VW-691

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

COHERENCE ONE PREAMPLIFIER

EMC Solutions Noise filtering

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

MAP110 AC-DC Series Data Sheet

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual

Power Circuit of a UL508A Panel. Typical UL489 Application

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Datasheet - SRB-E-201ST

Product Data Sheet 4656 ZW

Product Data Sheet 4656 EZ

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

Panel-mounting thermostats, type series EM

GR circuit breaker - hydraulic magnetic, Datasheet

SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Immersion Pumps HCT (High Chem) sealless

Fibre Optic Modem ODW-611

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Fibre Optic Modem ODW-622

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Transcription:

Capacitors and anks 50 Hz 0 Varplus M capacitors 051327 E92427 E92428 E89596 E89598 The range of Varplus M modular capacitors consists of the Varplus M1 and Varplus M4 capacitors, whose different assemly cominations cover power ratings from 5 to 100 kvar under 400 V/50 Hz. The range is availale in different types according to the level of harmonic pollution. Varplus M1 and M4 218 Weight of Varplus M1: 2.5 kg Weight of Varplus M4: 10 kg Accessories for Varplus M1 E89595 E89597 M8 210 95,5 116 95,5 211,5 210 192 218 192 83 95,5 ref. 52461 100 M8 325 350 445,5 113 ref. 52460 Standard type capacitors No polluted network (Gh/Sn y 15 %) Varplus M1 Varplus M4 400/415 V 400 V 415 V 5 52417 50 50 52422 7.5 52418 60 65 52423 10 52419 12.5 52420 15 52421 Overrated type capacitors Polluted network (15 % < Gh/Sn y 2 5%) Varplus M1 Varplus M4 400 V 470 V 400 V 415 V 470 V 4 6 52424 40 45 57.5 52429 5.5 8 52425 45 50 60 52430 7.5 10 52426 10 14.5 52427 11.5 16 52428 Detuned type Highly polluted network (25 % < Gh/Sn y 50 %) On request. capacitor rated voltage: v standard type: 415 V, three-phase 50 Hz v overrated type: 470 V, three-phase 50 Hz. maximum assemly power ratings: v several Varplus M1: 60 kvar v Varplus M4 and several Varplus M1: 100 kvar. Note: two Varplus M4 capacitors cannot e assemled together. HQ protection system uilt into each single-phase element: v high current fault protection y an HRC cartridge fuse v low current fault protection y the comination of an overpressure disconnect device with an HRC fuse. capacitance value tolerance: -5, +10 % insulation level: v withstand 50 Hz 1 min: 6 kv v impulse wave withstand 1.2/50 µs: - 25 kv if the rear panel is at least 15 mm away from all metal frames - 11 kv if the rear panel is up against a metal frame. maximum permissile current: v standard type: 1.31 In (400 V) v overrated type: 1.5 In (400 V). maximum permissile voltage (8 hours over 24 hours as in IEC 60831): v standard type: 456 V v overrated type: 517 V. internal discharge resistors: 50 V 1 min. losses (discharge resistors included): v from 400 to 690 V: y 0.55 W/kvar v 230 V: y 0.65 W/kvar temperature class (400 V): temperature of amient air (min. -25 C). Power Max. Highest average over all periods of ( C) 24 hrs 1 year Up to 65 55 45 35 67.5 to 90 50 40 30 92.5 to 100 45 35 25 v lifetime: 130 000 hours (temperature class D). colour: v ase and accessories: RAL 9002 v elements: RAL 9005. standards: IEC 60831 1/2, NF C 54-104, VDE 0560 Teil 41, CSA 22-2 No190, UL 810. Accessories for Varplus M1 Three-phase cale entry ox (IP42) 52460 Set of three terminal covers- 52461 ref. 52462 Accessories for Varplus M4 ref. 52464 Accessories for Varplus M4 Three-phase cale entry ox (IP42) 52464 Set of three terminal covers- 52462 Installation Assemly on vertical support (elements must e horizontal). For a lightning withstand of 25 kv, respect a distance of 15 mm etween the rear panel and all metal frames. 7 mars 2005 437E3065_Ver6.0.fm/1

0Varlogic N power factor controller 059646 059648 The Varlogic N controllers permanently measure the reactive power of the installation and control and dis of capacitor steps in order to otain the required power factor. Varlogic NR6/NR12 Varlogic NRC12 general data v operating temperature: 0 60 C v storage temperature: -20 C 60 C v colour: RAL 7016 v standard: - EMC: IEC 61326 - electrical: IEC/EN 61010-1. v panel mounting v mounting on 35 mm DIN rail (EN 50022) v protection class in panel mounting: - face: IP41 - rear face: IP20. v display: - NR6, NR12 type: acklighted screen 65 x 21 mm - NRC12 type: acklighted graphic screen 55 x 28 mm. - languages: English, French, German, Portuguese, Spanish v alarm contact v temperature internal proe v separate contact to control fan inside the power factor correction ank v access to the history of alarm. inputs v phase to phase or phase to neutral v insensitive to CT polarity v insensitive to phase rotation polarity v current input: - NR6, NR12 type: CT X/5 A - NRC12 type: CT X/5 A et X/1 A. outputs v potential free output contacts: - AC : 1 A/400 V, 2 A/250 V, 5 A/120 V - DC : 0,3 A/110 V, 0,6 A/60 V, 2 A/24 V. settings and parameters v target cos ϕ setting: 0,85 ind 0,9 cap v possiility of a dual cos ϕ target (type NRC12) v manual or automatic parameter setting of the power factor controller v choice of different stepping programs: - linear - normal -circular - optimal. v main step sequences: 1.1.1.1.1.1 1.2.2.2.2.2 1.2.3.4.4.4 1.1.2.2.2.2 1.2.3.3.3.3 1.2.4.4.4.4 1.1.2.3.3.3 1.2.4.8.8.8 v personalized sequences for NRC12 type v delay etween 2 successive switch on of a same step: - NR6, NR12 type: 10 600 s - NRC12 type: 10 900 s v step configuration programming (fixed/auto/disconnected) (NRC12 type) v 4 quadrant operation for generator application (NRC12 type) v manuel control for operating test. E88926 H 138 Dimensions Varlogic N Dimensions (mm) Weight H L D1 D2 (kg) Varlogic NR6/NR12 150 150 70 60 1 Varlogic NRC12 150 150 80 70 1 138 L D2 D1 Varlogic NR6, NR12, NRC12 437E3270_Ver2.0.fm/60 Schneider Electric

0Varlogic N power factor controller Type Numer of step Supply voltage (V) Measuring ref. output contacts network 50-60 Hz voltage (V) NR6 6 110-220/240-380/415 110-220/240-380/415 52448 NR12 12 110-220/240-380/415 110-220/240-380/415 52449 NRC12 12 110-220/240-380/415 110-220/240-380/415-690 52450 Varlogic N accessories Communication RS485 Modus set for NRC12 52451 Temperature external proe for NRC12 type. In addition to internal prole, allows measurement at the hotest point inside the capacitor ank. 52452 Better tuning of alarm and/or dis level. ref. Information supplied NR6/NR12 NRC12 Cos ϕ Connected steps Switching cycles and connected time counter Step configuration (fixed step, auto, disconnected) Step output status (capacitance loss monitoring) Network technical data: load and reactive currents, voltage, powers (S, P, Q) Amient temperature inside the cuicle Total voltage harmonic distortion THD (U) Total current harmonic distortion THD (I) Capacitor current overload Irms/I 1 Voltage and current harmonic spectrum (orders 3, 5, 7, 11, 13) History of alarms Alarms Threshold Action NR6/NR12 NRC12 Low power factor message and alarm contact Hunting (unstale regulation) message and alarm contact dis (2) Anormal cos ϕ < 0.5 ind or 0.8 cap message and alarm contact Overcompensation message and alarm contact Overcurrent > 115 % I 1 message and alarm contact Voltage low < 80 % Uo within 1 s message and alarm contact dis (2) Overvoltage > 110 % Uo message and alarm contact dis (2) Overtemperature θ u θo (θo = 50 C max) message and alarm contact dis (2) θ u θo - 15 C fan switch dis (2) Total harmonic distortion > 7 % message and alarm contact dis (2) Capacitor current overload (Irms/I 1 )> 1.5 message and alarm contact dis (2) Capacitor capacitance loss - 25 % message and alarm contact dis (2) Low current < 2,5 % message High current > 115 % message Under voltage 5 % Uo message Uo: input voltage (measurement) : alarm threshold values can e modified according to the installation (2): capacitor steps are automatically reconnected after fault clearance and a safety delay Schneider Electric 437E3270_Ver2.0.fm/61

Capacitors and anks 50 Hz PB100029-60 The detuned reactors (DR) are designed to protect capacitors and avoid harmonic amplification present on the network. Detuned reactors 400 V - 50 Hz : 4.3 (215 Hz) Power losses y the assemly 6.25 kvar/400 V - 50 Hz 4.71 9 100 51573 12.5 kvar/400 V - 50 Hz 2.37 17.9 150 52404 25 kvar/400 V - 50 Hz 1.18 35.8 200 52405 0.592 71.7 320 52406 100 kvar/400 V - 50 Hz 0.296 143.3 480 52407 : 3.8 (190 Hz) Power losses y the assemly 6.25 kvar/400 V - 50 Hz 6.03 9.1 100 51568 12.5 kvar/400 V - 50 Hz 3 18.2 150 52352 25 kvar/400 V - 50 Hz 1.5 36.4 200 52353 0.75 72.8 300 52354 100 kvar/400 V - 50 Hz 0.37 145.5 450 51569 : 2.7 (135 Hz) Power losses y the assemly 6.25 kvar/400 V - 50 Hz 12.56 9.3 100 51563 12.5 kvar/400 V - 50 Hz 6.63 17.6 150 51564 25 kvar/400 V - 50 Hz 3.14 37.2 200 51565 1.57 74.5 400 51566 100 kvar/400 V - 50 Hz 0.78 149 600 51567 three phase, dry, with magnetic circuit, impregnated cooling: natural degre of protection: IP00 class: H standard: IEC 60289, EN 60289 rated voltage: 400/415 V three phase 50 Hz tuning order (relative impedance): 4.3 (5.4 %) ; 3.8 (6.9 %) ; 2.7 (13.7 %) tolerance on L per phase: - 5, +5 % maximum permissile current: v Imp = 1.31. I 1 for tuning order 4.3 v Imp = 1.19. I 1 for tuning order 3.8 v Imp = 1.12. I 1 for tuning order 2.7 harmonic current spectrum: in % of current (I 1 ) Imp = [( 11. I 1 ) 2 + I 2 3 + I 2 5 + I 2 7 + I 2 11 ] 4.3 3.8 2.7 Current I 3 2 % 3 % 6 % Current I 5 69 % 44 % 17 % Current I 7 19 % 13 % 6 % Current I 11 6 % 5 % 2 % insulation level: 1.1 kv thermal withstand Isc: 25 x Irms, 2 x 0.5 second dynamic withstand: 2.2 Isc (peak value) dielectric test 50 Hz etween windings and windings/earth: 3.3 kv 1 minute thermal protection connected on terminal lock 250 V AC 2 A. 437E3285_Ver1.0.fm/2

Capacitors and anks 50 Hz Conditions of use use: indoor storage temperature: -40 C, +60 C relative humidity in operation: 20 to 80 % withstand in salt mist: 250 h operating temperature/altitude: Altitude Minimum Maximum Highest average over all periods of: (m) ( C) ( C) 1 year 24 h 1000 0 55 40 50 > 1000 y 2000 0 50 35 45 Installation forced cooling system compulsory windings of the detuned reactors fitted in upright position to ensure a good cooling system power : v screw type connector for detuned reactors 6.25 and 12.5 kvar v drilled terminals for detuned reactors 25, 50 and 100 kvar capacitors to e used in conjunction with detuned reactors must e rated at 470 V for a 400/415 V network. DB102283 Dimensions : 4.3 (215 Hz) y the assemly 6.25 kvar/400 V - 50 Hz 110 x 87 230 200 140 8.6 12.5 kvar/400 V - 50 Hz 205 x 110 230 245 140 12 25 kvar/400 V - 50 Hz 205 x 110 230 240 140 18.5 270 260 160 25 100 kvar/400 V - 50 Hz 205 x 120 330 380 220 42 : 3.8 (190 Hz) y the assemly 6.25 kvar/400 V - 50 Hz 110 x 87 230 200 140 8.5 12.5 kvar/400 V - 50 Hz 205 x 110 230 245 140 10 25 kvar/400 V - 50 Hz 205 x 110 230 240 140 18 270 260 160 27 100 kvar/400 V - 50 Hz 205 x 120 330 380 220 42 : 2.7 (135 Hz) y the assemly 6.25 kvar/400 V - 50 Hz 110 x 87 230 200 140 9 12.5 kvar/400 V - 50 Hz 205 x 110 230 245 145 13 25 kvar/400 V - 50 Hz 205 x 110 230 240 140 22 270 260 160 32 100 kvar/400 V - 50 Hz 205 x 120 330 380 220 57 205 x 120 or 205 x 130 mm. 437E3285_Ver1.0.fm/3