ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

Similar documents
Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

DLP200M 2 Relay Module for Heating and Cooling Plants

Process Transmitter RMA 422

PRINCIPLES AND APPLICATIONS

Process transmitter RMA422

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

DLP600M 6+1 Relay Module for Heating and Cooling Plants

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

I N S T R U C T I O N D A T A

REGO Start&Go USER MANUAL

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Generator protection relay

Model IQ4-PC User Manual Revision Date:

Standard signal metering in wall-mounting case

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

TC3005(LED/ELED/LASER) User's Manual

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

TeamWork Kits Installation Guide

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

Figure 1: Device components

Standard RS232 RS ma

ST-FO4K18GB-RS-LC. HDMI over Optical Fiber Extender VER 1.4

SERCOS TSX CSY 84 Module V

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

EGE-IR Bi-directional Infrared Matrix

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

DIAS power supply and DIC 221 fibre optic cable coupling module

Telemetry Receiver Installation Guide

Cylindrical Photoelectric Sensor CY-100 SERIES

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

10Gbps SFP+ Optical Transceiver, 10km Reach

Panel-mounting thermostats, type series EM

Trusted 40 Channel Analogue Input FTA

Quick Operation Guide of LTN7700/7600 Series NVR

INSTALLATION & USER GUIDE

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Power Injector 1520 Series

Local Control Network

Aegis Electronic Group

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

CHE-HDF18G01. Pro AV/IT HDMI 18G Fiber Extender TX/RX Kit up to 3300ft

High performance circuit breakers

Bill of Materials: Super Simple Water Level Control PART NO

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

HDBaseT Wall-plate Transmitter (2-Gang US Decora)

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

USER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

MICROMASTER Encoder Module

Model 1421 Distribution Amplifier

Miniature Synchronous/Asynchronous Fiber Optic Modems

EA350. Generator Automatic Voltage Regulator Operation Manual

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

E R A I GATE OPENERS DEPARTMENT

Amplifier for fiber optics. Dimensioned drawing

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

Description Diagram Page

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

TC1630. T1/E1 FIBER OPTIC MODEM User's Manual

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

APPLICATIONS. Automatic warehouse. Trasportation lines

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

Owners SW-LCD 2.0 Manual & Specifications

VHF & UHF REMOTE RECEIVERS INSTALLATION AND PROGRAMMING INSTRUCTIONS MODEL NUMBERS TMP-5414 & TMP 5428

Installation Instructions

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:

F M2SDI 2 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485 & Aux. User Manual

Trusted 40 Channel 120 Vac Digital Input FTA

Operating instructions Electronic preset counter Type series 717

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA

Dual HD-SDI Output (MCX + BNC connector) HD- SDI Cable Driver. HDMI DVI Tx connector. Optical HD- SDI Output LC - connector. 8pin

Tech Support: Customer Service: General Tech Questions: Tech Docs:

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Telemetry Receiver Installation Guide

CAMTO LTD. Arc detecting system DC/AC

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

Transcription:

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL Installation and programming Manual v2.2 1

MARSS Solar Defender SYSTEM This guidebook provides the essential instructions to install and configure the concentrator model ALM-6813/6812, operating in stand-alone mode. About operation mode on BUS RS-485, please refer to the control panel ALM-6800 installation and configuration manual. Important: Marss srl reserves the right to make changes to the product, specifications, or guide without prior notice, in order to improve quality and performance for product and system installation. Installation and programming Manual v2.2 2

Table of Contents Optical Fiber anti-theft system Solar Defender for panels...4 Optical Fiber module Solar Defender...5 Cautions for installation...5 Module Description...6 Bus Input Terminal Block...6 Fuse F4...7 Bus Output Terminal Block...7 Tamper Terminal Block...8 TX and RX Fiber optic connector...9 Loop Fiber 1 and Loop Fiber 2 relays...10 Reset Button...10 Open Collector OC1 and OC2 outputs...11 Open Collector OC1 use...11 First mode to use...12 Second mode to use...12 Third mode to use...13 X7 auxiliary power supply terminal block...14 Dip-switch SW2 Function...15 Dip-switch SW1 Address...16 Jumper JP3...18 Seven segment display...18 Fiber stripping...18 Optical Fiber cabling by...20 Fiber minimum curvature...22 Power Supply features...23 Power supply terminal blocks description...23 Spetification...25 Installation and programming Manual v2.2 3

Optical Fiber anti-theft system Solar Defender for panels The system MARSS Solar Defender operates with POF (Plastic Optical Fiber). The main features that make the optical fiber the best support for data transmission are: the immunity at electric nose and weather conditions, the low sensibly at the temperature changes. The operating principle of the MARSS system at optical fiber is very simple: the fiber is passed through the fastening holes on the panels frame, using the locking system ALM-6006 patented by MARSS srl. ALM-6813/6812 wiring diagram Installation and programming Manual v2.2 4

Optical Fiber module Solar Defender The module ALM-6813/6812 manages up to 2 lines of 200mt linear POF (Plastic Optical Fiber), by 2 Loop. It can operate in stand-alone mode or in centralized mode on BUS RS-485. ALM-6813: Optical Fiber module with supervised power supply. ALM-6812: Optical Fiber module without supervised power supply. This guide is related to the only stand-alone operation mode. About operation mode on BUS RS-485, please refer to the control panel ALM-6800 installation and configuration guide. Cautions for installation Take the following precautions to prevent your own and other safety: To connect the 230v electric line, use cables with additional sheath to guarantee a larger protection. To avoid fire risks, replace the fault fuses on the panel s motherboard with fuses of the same value and model. To avoid explosion risks, replace the backup battery with battery of the same model. To protect the user and the equipments from over voltage or air discharges, connect the ground wire at any device. Installation and programming Manual v2.2 5

Module Description Bus Input A B C D Terminal Block Terminal block to connect the BUS RS-485 comes from the panel. (Only when the concentrator operates in on Bus mode; in stand-alone mode, it is not used). A Data Bus A (GREEN with MARSS cable model ALM-6021) B Data Bus B (YELLOW with MARS cable model ALM-6021) C Negative of supply towards the next concentrator (BLACK with MARSS cable model ALM-6022 and with any other cable) D Positive +24V towards the next concentrator (RED with MARSS cable ALM-6022 is used) Installation and programming Manual v2.2 6

Fuse F4 Rapid Fuse 1A to protect the BUS supply coming from the control panel. Bus Output A B C D Terminal Block Terminal block to connect the BUS RS-485 to the next concentrator. A Data Bus A ( GREEN with MARSS cable model ALM-6021) B Data Bus B (YELLOW with MARSS cable model ALM-6021) C Negative of supply towards the next concentrator ( BLACK with MARSS cable model ALM-6022 and with any other cable) D Positive +24V towards the next concentrator( RED with MARSS cable ALM-6022) Installation and programming Manual v2.2 7

Tamper Terminal Block The concentrator is equipped with a long lever microswitch, to protect the case from possible openings. In on BUS operating mode, the concentrator will signal the manomission to the panel by BUS. In stand-alone mode, it s possible to use the terminal block to connect at any anti-theft panel or alarm communication device (dialer, radio link, etc ): in this case, the jumper JP2 and JP5 have to be removed. Note: In both operation modes, on BUS and stand-alone, after the installation and testing of the module, please remove the jumper on the external tamper terminal block, otherwise the tamper will remain inactive. Installation and programming Manual v2.2 8

TX and RX Fiber optic connector The concentrator is equipped with 4 fiber connectors: 2 for TX and 2 for RX (it s not necessary to make a perfect lapping before to connect the fiber). The TX and RX are calibrated to use POF of 200mt maximum length. In case of fiber interruption, the optical transmitter detects the light change and sends information at the module. In BUS operating mode, the control panel Solar Defender (ALM-6800) inquires in polling the single modules, detects the status and manages the events as an alarm. In standalone mode, the alarm relay related the interested Loop fiber, will activate. Installation and programming Manual v2.2 9

Loop Fiber 1 and Loop Fiber 2 relays The module is equipped with two signalling relays: Line1 for the Loop1 (TX1-RX1) and Line2 for the Loop2 (TX2-RX2). The two relays will be active in case of fiber break or cut. Reset Button The S1 button is used to reset the concentrator after an alarm signal. It can also be resetted by an external device (GSM dialer, etc...), using the "External Reset" terminal block (normally open contact). Installation and programming Manual v2.2 10

"OC1 and OC2" Open Collector Outputs Open collector outputs with negative closing. The operating scheme is as follows: When the transistor is at rest, on the collector there is no tension. When it is activated through the base resistor, the transistor enters in conduction, giving out a negative voltage. To test the output operation, just connect a voltmeter between the positive and the collector (on the positive of the module there is a voltage of +12 V). When the open collector output is switched on, between the collector and the positive of supply, will measure a voltage of 12V. Note :On the module is active only the OC1 output. The OC2 output is currently not used. OC1 Open Collector Output use The output OC1 is a module operation security check. It 's always-on until the module is plugged on 230V and / or backup battery and is in function. In case of lack of the both power supplies, or Fuse F1 failure (module ALM-6812), there will be no tension on the OC1 output. It 's very important to use this output when using theconcentrator ALM6813 or ALM6812 in stand-alone mode. In on BUS mode these reports, are managed by the control panel ALM- 6800. Important Note: Use the output OC1 is necessary for reporting the failure of the module. The following article describes three ways to use this output. These rules also apply to any open collector output of any system, with close to negative. Installation and programming Manual v2.2 11

First mode to use Open collector output direct connection to a 12V relay This is the easiest way to connect an open collector output with negative closing. The transistor on the ALM-6813/6812 is always on. It is disabled when there is the complete lack of 230V and backup battery. In this case the connected relay is always on. It switches off only with the absence of the power. This affects of about 20mA on the total absorption of the concentration (the absorption varies with the type of relay used). Note: When the concentrators operate on BUS, all these signals are automatically managed by the control panel. This connection is used only in stand-alone mode. Second mode to use Open Collector output direct connection to an alarm input The OC1 open collector output can be directly connected to an alarm input of any burglar alarm system or telephone dialer with the zones operate at negative. To verify this, just check on the panel, the dialer or the expansion input at issue, the continuity between the commonbase of the alarm zones and the negative power: if there is continuity, is possible to connect the OC1 as the above wiring diagram. 0V is any negative power on the module (for convenience, use the negative of the X9 auxiliary power terminal described on next page). Otherwise, avoid this method of connection. Note: In on BUS mode, all these signals are automatically managed by the control panel. This connection is used only in s tand-alone mode. Installation and programming Manual v2.2 12

Third mod to use Open Collector output connection to a relay separate form the concentrator The main problem of the first connection method described above, is that the relay is always on, increasing of about 20mA (it depends on the type of relay connected) the power consumption for each module. To resolve this problem just use, in addition to the relay, some components easy to find and use. R1: Resistor 470ohm 1/4W 5% R2: Resistor 15Kohm 1/4W 5% T1: Transistor NPN type BC337B D1: Diode type 1N4007 Relay: Relay 12V DC coil, type SMI-12VDC-SL-C With this connection mode, the relay will be activated only when the modules turn-off themselves totally, by starting an alarm signal for lack of supply on the concentrators. Note: When the module operates on BUS mode, all these reports are automatically managed by the control panel ALM-6800. This connection is used only in stand-alone mode. Installation and programming Manual v2.2 13

X7 auxiliary power supply terminal block The power supply on board is equipped with backup battery charging circuit with load and operation test. In on Bus mode, all modules have the control of the power supply and batteries. In case of a fault, the optical fiber module ID number with the power supply in fault is reported directly on the control panel by Bus. However it s possible to use any other 12V power supply brand model (1.5 A minimum). In this case it is not possible to manage the control of power presence and efficiency of the backup battery. Fuse F1 Rapid Fuse 1A to protect the auxiliary power. Replace only with equal value. Jumper JP6 JP3:Actives the line termination. To be activated only if requested by MARSS Technical Service JP6:Enables the module starting in stand-alone mode. On Bus mode only, it must be removed. Installation and programming Manual v2.2 14

Dip-switch SW2 Function The dip-switch SW2 has 4 micro switches. The microswitch 2 is not used. The microswitch 1 is used to disable the Loop fiber 2. This function is used when on the concentrator is active a Loop fiber only. Micro switch 1 on ON => Loop2 Off (Dot 7-segment display on) Micro switch 1 on OFF => Loop2 On (Dot 7-segment display off) The micro switch 3 and 4 are used to activate the function control of the fiber signal level reading. In this way you can be sure of the best reading/transmission of the signal through the fiber. When the function is enabled (for single channel), the 7-segment display will show a value between 0-9. Installation and programming Manual v2.2 15

0 Reading/transmission value too low 1 Reading/transmission value too low 2 Reading/transmission value acceptable 3 Reading/transmission value medium 4 Reading/transmission value medium 5 Reading/transmission value optimal 6 Reading/transmission value optimal 7 Reading/transmission value optimal 8 Reading/transmission value optimal 9 Reading/transmission value optimal Micro switch 3 => ON Control Function active on Loop1 Micro switch 4 => ON Control Function active on Loop2 Important Note: The control function must be enabled one Loop for time. After the test on Loop1, return the micro-switch 3 on OFF position and proceed with the micro switch 4. After testing, make sure both the micro switch (3 and 4) are OFF. Dip-switch SW1 Address micro switch 1, 2, 3, 4, 5, 6 The module can be connected on Bus mode and managed by the control panel ALM-6800. In this way an only panel can manage up to 48 concentrator modules connected on a single RS- 485 Bus. In On Bus mode, each concentrator module must have its own unique ID address. Installation and programming Manual v2.2 16

The following table shows all combinations to address the module. Remember: made the addressing operation with the module off Address Dip-6 Dip-5 Dip-4 Dip-3 Dip-2 Dip-1 00 (not used) OFF OFF OFF OFF OFF OFF 01 OFF OFF OFF OFF OFF ON 02 OFF OFF OFF OFF ON OFF 03 OFF OFF OFF OFF ON ON 04 OFF OFF OFF ON OFF OFF 05 OFF OFF OFF ON OFF ON 06 OFF OFF OFF ON ON OFF 07 OFF OFF OFF ON ON ON 08 OFF OFF ON OFF OFF OFF 09 OFF OFF ON OFF OFF ON 10 OFF OFF ON OFF ON OFF 11 OFF OFF ON OFF ON ON 12 OFF OFF ON ON OFF OFF 13 OFF OFF ON ON OFF ON 14 OFF OFF ON ON ON OFF 15 OFF OFF ON ON ON ON 16 OFF ON OFF OFF OFF OFF 17 OFF ON OFF OFF OFF ON 18 OFF ON OFF OFF ON OFF 19 OFF ON OFF OFF ON ON 20 OFF ON OFF ON OFF OFF 21 OFF ON OFF ON OFF ON 22 OFF ON OFF ON ON OFF 23 OFF ON OFF ON ON ON 24 OFF ON ON OFF OFF OFF 25 OFF ON ON OFF OFF ON 26 OFF ON ON OFF ON OFF 27 OFF ON ON OFF ON ON 28 OFF ON ON ON OFF OFF 29 OFF ON ON ON OFF ON 30 OFF ON ON ON ON OFF 31 OFF ON ON ON ON ON 32 ON OFF OFF OFF OFF OFF 33 ON OFF OFF OFF OFF ON 34 ON OFF OFF OFF ON OFF 35 ON OFF OFF OFF ON ON 36 ON OFF OFF ON OFF OFF 37 ON OFF OFF ON OFF ON 38 ON OFF OFF ON ON OFF 39 ON OFF OFF ON ON ON 40 ON OFF ON OFF OFF OFF 41 ON OFF ON OFF OFF ON 42 ON OFF ON OFF ON OFF 43 ON OFF ON OFF ON ON 44 ON OFF ON ON OFF OFF 45 ON OFF ON ON OFF ON 46 ON OFF ON ON ON OFF 47 ON OFF ON ON ON ON 48 ON ON OFF OFF OFF OFF Addressing the module, the stand-alone operation mode and the P1 reset button will be automatically disabled. In case of lock of the module, a reset is possible by switching off and switching on after a few seconds the power supply. To reactivate the stand-alone mode, just put all the addressing micro switches (1, 2, 3, 4, 5, and 6) on OFF with the module turned off. Installation and programming Manual v2.2 17

Jumper JP3 Use only if requested by MARSS Technical Service 7-Segments Display The 7-segment display on board of the module, displays which of the 2 Loops fiber is tripped. The displayed alarms are: 1 Alarm Loop fiber 1 2 Alarm Loop fiber 2 1 Alarm Loop fiber 1 2 Alarm Loop fiber 2 _ Segment ON: Loop2 disabled. Segment OFF: Loop2 active. The module is now active and ready to operate H24. Fiber Stripping Installation and programming Manual v2.2 18

Case grommets Installation and programming Manual v2.2 19

Optical Fiber cabling by "Sigillo" ALM6006 Most of the photovoltaic panels have holes on the frame often not used. Through these holes you can pass the optical fiber, but with the risk of getting too tight curves that can drastically affect the transmission of optical signal. The passage of the fiber presents many difficulties and risks of excessive abrasion of the same. Installation and programming Manual v2.2 20

Sigillo Solar Defender model ALM-6006 has made to facilitate the installation of the optical fiber on the panels; it allows obtaining various advantages: 70% reduction of installation times. An accurate installation of the optical fiber. Mechanical protection of the panel. The optical fiber must be passed through the four cable glands on the module case. After the fiber installation, the cable glands must be tightened. Installation and programming Manual v2.2 21

Minimum curvature of the fiber The minimum radius for transmitting and reading the optical signal through the fiber must be greater than or equal to 50mm. A curvature radius lower than can cause damage to the fiber with the inevitable replacement of the same, and drastically reduce the transmission and reading signal, causing alarms cut fiber. The optimal reading of the signal through the fiber, is adjusted on a maximum length of about 200m. If you use greater lengths, the transmission/reading of the signal can be less of the threshold value setted on the module: cut fiber false alarms will be possible. The fiber can be fixed with cable ties, paying attention because all the curves made during installation will be the most possible "soft" (50mm minimum radius). Installation and programming Manual v2.2 22

Power supply features (only ALM-6813) Description of the terminal blocks 230V Terminal block 7.62 mm pitch terminal block to connect the mains voltage 230V AC 50Hz. The 230V line is protected by two rapid fuses 1A (F3, F5). Replace fuses F3 and F5 only with ones of equal values. Important: All the concentrators must be grounded through the power supply terminal block 230V. The absence of the connection can be cause of damage in case of lightning or surges. Installation and programming Manual v2.2 23

Connection Terminal Block The concentrator is powered by the 5-pin connector. The power supply has on board also an 8- pin terminal block Backup Battery autonomy TERMINAL BLOCK DESCRIPTION B- Negative Backup Battery Terminal Block B+ Positive Backup Battery Terminal Block PWCK OC output 230v line lack BTCK OC output battery fault PRST Input to reset the concentrator by BUS +12V Auxiliary output 12V max500ma Operating autonomy tested with 12V 7Ah battery is 60 hours (battery efficiency). The data refer to the concentrator ALM-6813. Note: The autonomy of battery depends on: the type of battery used; the condition of the battery used (recommended periodic replacement battery within 2 years and beyond, from installation; the possible load on the +12 V (500mA max). Switching power supply on board: Features Input Voltage 88 ~ 264VA Frequency 47 ~ 63Hz Output Voltage 15V (13.5 ~ 16.5V settable) Max power 1,7A Rated power 25W Dimensions 78x51x28mm Operating Temperature -20 C ~ 70 C Operating Humidity 20 ~ 90% Protection Input and Output Overcurrent and Overvoltage Installation and programming Manual v2.2 24

Note: Installation and programming Manual v2.2 26

Note: Installation and programming Manual v2.2 27

Installation and programming Manual v2.2 28