Overall vibration, severity levels and crest factor plus

Similar documents
Overall vibration, severity levels and crest factor plus 3 CF+ White Paper

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

An Introduction to Vibration Analysis Theory and Practice

9070 Smart Vibration Meter Instruction Manual

Affected Products: Product Line Category Device Version Machinery Health Management. Data Analysis

Reciprocating Machine Protection

MachineryMate 800 operating guide Handheld vibration meter

The above chart is used in ISO method to determine the alarm and trip limit for rotating machines equipped with rolling element bearings.

HOW TO START A PREDICTIVE MAINTENANCE PROGRAM. Richard D. Hall. National Electrical Carbon Products

Phase Analysis: the missing weapon

Full Disclosure Monitoring

System 1* Evolution - Part 2

MONITORING AND ANALYSIS OF VIBRATION SIGNAL BASED ON VIRTUAL INSTRUMENTATION

An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR

Work no. 2. Doru TURCAN - dr.ing. SKF Romania Gabriel KRAFT - dr.ing. SKF Romania

onitoring Bearing Vibration with Seismic Transducers

Pelletizer Motor Bearing Damage Detection Based on Vibration Data. John J. Yu Carl Feng Wang Tony Wei Zhou Nicolas Péton Haibo Lin Jun Quan

Machinery Diagnostic Plots Part 2 ORBIT Back-to-Basics: What does the data really tell us?

CASE HISTORY#3 COOLING TOWER GEARBOX BEARING FAULT. Barry T. Cease Cease Industrial Consulting

Enhanced Diagnostics through Ultrasound Imaging

Maintenance Strategies For Cost Reduction and Quality Improvement

Condition Monitoring Custom Products

Transient Vibration Analysis of Refinery Steam Turbines using Labview Program

Dramatic Vibration Improvement due to Ring-Section Pump Foundation Repair Based on ODS in a Power Plant

Getting Started with the LabVIEW Sound and Vibration Toolkit

Condition Monitoring Program: A Need to Improve Performance of Machineries

Machinery Diagnostic Plots Part 1 ORBIT Back-to-Basics: What does the data really tell us?

Test Report: Gamma Vibration & Shock

Laser measurements in the motor bearing diagnostics. Ariel Dzwonkowski 1, Leon Swędrowski 2

Roots * RAS-J Air & RGS-J Gas Blowers. GE Energy

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

DIRECT DRIVE ROTARY TABLES SRT SERIES

UNBALANCE DEFECT DETECTION IN ROTATING MACHINES BY MEANS OF SOUND ANALYSIS

Event recording (or logging) with a Fluke 287/289 Digital Multimeter

Sub-Synchronous PLACE Vibration FOR TITLE on Centrifugal Compressor with Tilt-Pad AUTHORS

The Turbomachinery Vibration Software

Real-time Chatter Compensation based on Embedded Sensing Device in Machine tools

LabVIEWTM. Order Analysis Toolkit User Manual. LabVIEW Order Analysis Toolkit User Manual. July C-01

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

Calibrating attenuators using the 9640A RF Reference

HyPrecision Waterjet. Optimizing waterjet performance

ECE438 - Laboratory 4: Sampling and Reconstruction of Continuous-Time Signals

Processing for Improved Spectral Analysis

Selection Table. Ordering Information

Spectrum Analyser Basics

Oscilloscopes for field applications

NetterVibration. Netter Electric External Vibrators Series NEG. Serving industry with vibration

Simple motion control implementation

Belt Faults. This paper looks at the vibrations produced by a bad belt.

ANALYSIS OF COMPUTED ORDER TRACKING

HyPrecision Waterjet. Optimizing waterjet performance

Defense Technical Information Center Compilation Part Notice

Dither Explained. An explanation and proof of the benefit of dither. for the audio engineer. By Nika Aldrich. April 25, 2002

SnapStak Stackable Snap-In Cable Hanger Electrical and Mechanical Testing Performance

HEAD. HEAD VISOR (Code 7500ff) Overview. Features. System for online localization of sound sources in real time

PSC300 Operation Manual

SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR

Compressor rub verified by rotating phase symptoms

Appendix D. UW DigiScope User s Manual. Willis J. Tompkins and Annie Foong

ROBOTEQ, INC. PRODUCT VIBRATION AND SHOCK TESTING of the Motor Controllers and Magnetic Sensor Report No A Proposal No.

The Cathode Ray Tube

E X P E R I M E N T 1

Product Overview. Rotary Encoders for the Elevator Industry

CR7000. CRT Analyzer & Restorer. Easily Test And Restore CRTs With The Most Complete Tests Available For Added Profit And Security.

Zero Crossover Dynamic Power Synchronization Technology Overview

Application of cepstrum prewhitening on non-stationary signals

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing

Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders

EngineDiag. The Reciprocating Machines Diagnostics Module. Introduction DATASHEET

EngineDiag. The Reciprocating Machines Diagnostics Module. Introduction DATASHEET

EDDY CURRENT IMAGE PROCESSING FOR CRACK SIZE CHARACTERIZATION

HyPrecision Waterjet. The world's most profitable waterjets

Eddy Current Probe System

Analysis of vibration signals using cyclostationary indicators

White Paper JBL s LSR Principle, RMC (Room Mode Correction) and the Monitoring Environment by John Eargle. Introduction and Background:

Choosing an Oscilloscope

LabView Exercises: Part II

Low-Noise, High-Efficiency and High-Quality Magnetron for Microwave Oven

Transducers and Sensors

EE-217 Final Project The Hunt for Noise (and All Things Audible)

ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor

(Refer Slide Time: 00:55)

Screw pump Series ALLFUEL AFT

VARIABLE SPEED USER MANUAL. Premium Efficiency Variable Speed Motor

3500/42M Proximitor * /Seismic Monitor Bently Nevada* Asset Condition Monitoring

BY ADRIAN MESSER, UE Systems, Inc.

Davis December 18, 2009

3500/42E Vibration Monitor

Improved Synchronization System for Thermal Power Station

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Oscilloscopes for field applications

Manipulator Technical Specification Welding/Cutting expert

Mechanical aspects, FEA validation and geometry optimization

Transporting NV Standardized Testing from the Lab to the Production Environment

Investigation of Digital Signal Processing of High-speed DACs Signals for Settling Time Testing

RF Safety Surveys At Broadcast Sites: A Basic Guide

Incremental Encoder DFS60 in a class of its own. The high-resolution incremental encoder range

3500/42M Proximitor*/Seismic Monitor

Latvis Interview Reprint

Transcription:

WHITE PAPER Overall vibration, severity levels and crest factor plus By Dr. George Zusman, Director of Product Development, PCB Piezotronics and Glenn Gardner, Business Unit Manager, Fluke Corporation High frequency 4,000 Hz to 20,000 Hz 01/09/2011 09:10 AM Bearing 3 CF+ Bearing vibration (CF+) Low frequency 10 Hz to 1,000 Hz GOOD Overall Vibration 0.42 in/s (cal pk) Overall vibration Temperature -20 C to 200 C UNACCEPTABLE Temperature 68.7 F ID :FAN1:BEARING1 TYPE :Axial Fan RPM :> 600 IR Temperature Severity Scale GOOD SATISFACTORY No immediate repair is recommended. No immediate repair is required. Increase the frequency or measurements and monitor the condition of the machine. UNSATISFACTORY Have knowledgeable vibration technician conduct more advanced testing at the earliest opportunity. Consider taking maintenance action during the next planned downtown or maintenance period. UNACCEPTABLE Have knowledgeable vibration technician conduct more advanced testing as soon as possible. Consider immediate shutdown of the machine to make repairs and prevent failure. Introduction Mechanical Vibration is a notoriously difficult subject matter to master. A quick glance at a textbook in the field shows that the advanced practitioner must master sophisticated concepts in mathematics and physics in order to accurately collect and interpret vibration data. This has caused a major problem for industrial plants the benefits of a vibration testing program are well known, but far too many plants choose to avoid vibration testing because of the perceived complexity. Fluke aims to solve this dilemma by developing easy to use vibration products that yield significant benefits without requiring advanced training by end-users. Fluke s first vibration product, released in 2010, was the 810 Vibration Tester (see picture on next page). The 810 is a vibration spectrum analyzer that includes an automated diagnostic engine that identifies the four most common root causes of abnormal machinery vibration: Misalignment, Unbalance, Looseness, and Bearing Faults. The 810 is dramatically easier to use than existing spectrum analyzers because the interpretation of frequency spectrum data is automated. The user simply sees a severity scale for each of the four faults listed above. Fluke s second vibration product, the 805 FC Vibration Meter, was released in 2012. The 805 FC is an overall vibration meter, as compared to a spectrum analyzer like the Fluke 810. The 805 FC provides the user a simple overall vibration number for both low frequency (10 1,000 Hz) and high frequency (4,000 20,000 Hz) ranges. In addition to the overall vibration value, the 805 FC provides a severity scale for both frequency ranges. The low frequency severity scale can be adjusted to reflect the particular type of machine being tested (pump, compressor, etc.), and is a great way to screen for problems such as misalignment, unbalance, looseness, bent rotors, etc. The high frequency severity scale, known as the Crest Factor Plus scale, uses a novel proprietary method of processing time domain vibration signals to identify bearing flaws. The 805 FC also provides the user a non-contact temperature reading for all vibration points tested. The 805 FC overall vibration meter is a screening tool. Once an adverse vibration condition has been identified by the 805 FC, it is recommended that the team perform more advanced testing to validate the problem and identify the root cause of the vibration.

In this white paper, we ll discuss the following topics: The difference between frequency spectrum analysis and overall vibration analysis. Overall vibration analysis and severity scales Crest Factor Plus: High frequency overall vibration analysis and severity scales Vibration spectrum analysis vs. overall vibration analysis All vibration data is collected in the time domain. When using a spectrum analyzer or overall vibration meter, this time domain data is typically collected from a piezoelectric accelerometer. The accelerometer is placed in rigid contact with a vibrating machine. The machine vibration is transferred to the accelerometer, which in turn strains the piezoelectric element within and creates a voltage signal proportional to the vibration. This voltage signal is captured by the spectrum analyzer or overall vibration meter. A sample time domain signal is shown on next page (Fig A). Once the time domain signal has been captured, there are two common analysis methods that can be performed: spectrum analysis or overall vibration analysis. Slight Moderate Serious Extreme No repair action is recommended. Retest the machine and monitor condition after maintenance. (Months, even up to a year) - No immediate repair action required. Increase the frequency of measurements and monitor the condition of the machine. (Weeks) - Take maintenance action during the next planned downtime or maintenance period. (Days) - Immediate action is required. Consider shutting down the equipment and taking repair action now to avoid failure. In spectrum analysis, the time domain signal is transformed into a frequency domain signal using an algorithm known as the Fast Fourier Transform (FFT). A detailed description of the FFT is beyond the scope of this white paper, but in short it reconstructs the time domain signal using a series of harmonic sine waves. The amplitude of each of these sine waves is then plotted against the frequency of the sine waves. The result is known as a frequency spectrum plot. A sample frequency spectrum plot is shown on next page (Fig B). A properly trained vibration analyst can use the frequency spectrum to determine which, if any, machinery flaws exist. The analysis can be somewhat complicated, but a significant benefit is that the root cause of the vibration problem can typically be identified. Overall vibration analysis, by contrast, is much simpler. In overall vibration analysis, the time 2 Fluke Corporation Overall vibration, severity levels and crest factor plus

Figure A Figure B domain data is used to calculate one single overall vibration value. This single value can be used as an indicator of the overall health of the machine. (Note: there are multiple methods available for calculating the overall vibration value. They are described in the appendix for the interested reader). The benefit of overall vibration analysis is its simplicity there is only one number to examine. However, there are three limitations of using overall vibration analysis that are worth noting: Different machines have different healthy levels of overall vibration. Certain machinery flaws, particularly bearing flaws, will not impact the overall vibration value until significant damage has occurred. Overall vibration analysis does not identify the root cause of vibration Despite these limitations, overall vibration meters are still very valuable as a screening tool. Technicians can use them to trend values over time, and if any adverse trends are identified a more thorough analysis (such as spectrum analysis) should be performed to validate the problem and identify the root cause. It is noteworthy that Fluke has designed the 805 FC vibration meter to help mitigate these limitations, as discussed on the next page. Overall vibration analysis and severity scales As discussed in the previous section, there are three key limitations of overall vibration analysis. In this section we ll explain a bit more about each of these limitations, and then show how an overall vibration meter can be an effective vibration screening tool despite the limitations. We ll also show how the Fluke 805 FC vibration meter specifically helps to overcome the three limitations of a conventional vibration pen. The value of an overall vibration meter There are many advantages to overall vibration analysis, including: Overall vibration analysis does not require extensive training to implement. Nearly any technician can utilize an overall vibration meter, which enables the testing of a much broader base of machines at a plant. An overall vibration meter, when used as a screening tool, can very effectively identify machines which should be given more in-depth vibration testing. Any machine that shows an adverse trend in overall vibration level over time, or that shows an abnormally high overall value in any one test, should be tested further using more advanced techniques. Overall vibration meters are inexpensive they can be purchased for about one tenth the cost of a vibration spectrum analyzer. In addition, to these advantages, Fluke put in a tremendous amount of effort into designing the 805 FC Vibration Meter such that the limitations of an overall vibration meter are mitigated. For example: 1. The Fluke 805 FC includes a severity scale for overall vibration for 37 commonly found industrial machinery types (categories). When using the 805 FC, simply select the machine category you are testing from the list within the device and the 805 FC will provide you with a severity scale showing how severe the overall vibration value you ve measured is. Please see the appendix for a listing of the 37 machinery types (categories) covered by the Fluke 805 FC. 3 Fluke Corporation Overall vibration, severity levels and crest factor plus

High frequency 4,000 Hz to 20,000 Hz Low frequency 10 Hz to 1,000 Hz Temperature -20 C to 200 C 01/09/2011 09:10 AM Bearing 3 CF+ GOOD Overall Vibration 0.42 in/s (cal pk) UNACCEPTABLE Temperature 68.7 F ID :FAN1:BEARING1 TYPE :Axial Fan RPM :> 600 Bearing vibration (CF+) Overall vibration IR Temperature 2. The Fluke 805 FC uses a new proprietary algorithm known as Crest Factor Plus that identifies bearing flaws much earlier than a simple overall vibration meter is capable of. The Crest Factor Plus algorithm utilizes high accuracy high frequency measurements, and is described in the next section. 3. The Fluke 805 FC is wireless enabled and syncs through the Fluke Connect system directly to your smart phone, tablet, or CMMS software without manual transcription. This feature allows measurements to be assigned to a specific asset for maintenance baselines and histories, trending over time for intermittent issues, and collaboration through ShareLive in the Fluke Connect app. The measurements can be included in work orders via PDF, excel, or screen captures. 4. The Fluke 805 FC includes the ability to download results to an Excel template for tracking and trending. Although a spectrum analyzer is the best tool for determining the root cause of a high vibration condition, the tracking and trending of overall vibration values is a great way to identify machines which may have flaws and should be considered for more advanced testing. Crest factor plus and high frequency severity scales Certain machinery flaws (bearing flaws in particular) don t reveal themselves in an overall vibration value until significant damage has already occurred. This occurs for a simple reason: the early warning signs of a bearing failure are very short duration spikes in the time domain signal. Since these spikes are short in duration, they carry very little energy, and therefore they don t have a significant impact on the overall vibration value. In an effort to better identify early signs of bearing damage, some overall vibration analysts began using the Crest Factor, which is defined as the ratio of the Peak / RMS of a time domain signal (where the RMS = Root-mean-square). The Crest Factor was actually very good for identifying early signs of bearing failure, because the significant difference between the short duration peak value and the RMS value caused the Crest Factor value to increase rapidly during the early stages of bearing failure. However, a problem occurred as the bearing damage worsened. The significant bearing damage caused the RMS value of the time domain signal to increase significantly. Since RMS is in the denominator of the Crest Factor ratio, this actually caused the Crest Factor value to decrease. Counter-intuitively, the value of the Crest Factor would decrease as bearing damage worsened. The analyst who saw a low Crest Factor value could not be certain whether the bearing was healthy or near failure - clearly not an acceptable state of affairs. In an effort to overcome this problem with Crest Factor analysis, the Fluke 805 FC utilizes a proprietary algorithm known as Crest Factor Plus. Crest Factor Plus values can be related to bearing damage according to the following chart: CF+ Severity 0 to 5 Good 6 to 10 Satisfactory 11 to 15 Unsatisfactory above 15 Unaccepatable The Crest Factor Plus algorithm is a significant step forward from traditional crest factor vibration analysis because the output value (CF+) increases continually as the bearing damage worsens. Some technical details about the algorithm are provided in Appendix 2. The three limitations of overall vibration analysis The first limitation of Overall Vibration Analysis is that different machines have different healthy levels of overall vibration. Rotary blowers, for example, have very high overall vibration levels even when they are in a healthy state. This is caused by the basic mechanical design of the machine, which consists of two parallel shafts with interleaving lobes rotating in synchronization to compress air. By comparison, single-end suction centrifugal pumps (which have only one rotating shaft and an impeller rotating inside of a volute) tend to have very low overall vibration levels in the healthy state. An overall vibration level of 0.300 in/s on the centrifugal pump is indicative of a problem with the machine, whereas that same vibration level on a rotary lobe compressor indicates a healthy machine. The second limitation of overall vibration analysis is that certain machinery flaws, particularly bearing flaws, will not cause an alarm in the overall vibration level until significant damage has occurred. When a bearing is first starting to fail due to a flaw on the outer race, inner race, or ball/roller, very short duration spikes will appear in the time domain each time the flaw makes 4 Fluke Corporation Overall vibration, severity levels and crest factor plus

Healthy time domain signal Both CF and CF+ levels are low Early bearing damage time domain signal Both CF and CF+ levels are medium Heavy bearing damage time domain signal CF level returns to a low value, but CF+ level is high contact with an adjacent bearing component. These spikes have very low energy, and therefore cause very little change to the overall vibration value. As the bearing damage progresses, the spikes will continue to increase in energy along with the baseline vibration of the machine, and ultimately will cause the overall vibration value to increase prior to catastrophic failure. However, it would be ideal to identify a bearing flaw early on in the process when the spikes still have low energy, and overall vibration analysis is a poorly suited tool to accomplish this. The third limitation of overall vibration analysis is that once a severe level of vibration has been detected, it is not possible to determine the root cause of this vibration using overall vibration analysis alone. Frequency spectrum analysis, by comparison, allows the experienced analyst to identify the likely root cause of the vibration by looking for patterns in the spectrum that are indicative of flaws such as unbalance, misalignment, looseness, bearing damage, worn or loose belts, etc. Conclusion In this white paper we ve focused on two vibration analysis methodologies that can be used to examine accelerometer-based vibration data: frequency spectrum analysis and overall vibration analysis. We learned that both methods have strengths and limitations. Frequency spectrum analysis is ideal for identifying the root cause of a vibration problem, but requires rather advanced training to implement. Fluke designed the 810 to overcome this limitation by including a diagnostic engine that automatically identifies the severity of the four most common machinery problems: misalignment, unbalance, looseness, and bearing damage. Overall vibration analysis is inexpensive and easy to implement, but faces some key limitations, including: different machine types exhibit different levels of overall vibration in a healthy state; and bearing damage does not impact the overall vibration reading until significant damage has occurred. Fluke designed the 805 FC to overcome these two problems, respectively, by including severity scales tailored to 37 different machine categories and by including the Crest Factor Plus algorithm for earlier detection of bearing flaws. In a robust predictive maintenance program, both frequency spectrum analysis and overall vibration analysis have their proper place. Both tools should be used in conjunction to identify machinery flaws early so that corrective action can be taken prior to machine failure. 5 Fluke Corporation Overall vibration, severity levels and crest factor plus

Appendix 1: Methods for calculating the overall vibration value There are multiple methods available for calculating the overall value of a vibration signal. The key differences are: Peak vs. RMS Time domain vs. frequency domain Units: Acceleration vs. velocity vs. displacement Peak vs. RMS Overall vibration can be expressed as either a peak or an RMS value. The peak value is simply defined as the absolute value of the highest magnitude peak above or below the origin in a time domain signal. In the time waveform show below the peak value is approximately 4.0 because the highest peak is 4.0 units away from the origin. The RMS value, by contrast, is calculated using all of the values in the time waveform according to the following formula: where x(t) are the individual values of the time series data. Units: Acceleration vs. velocity vs. displacement The overall vibration can also be expressed in different units: Acceleration [most commonly expressed in g s], Velocity [most commonly expressed in or ], or Displacement [most commonly expressed in mils (i.e. thousandths of an inch) or µm (micro-meters)]. By definition, accelerometers collect time series data in acceleration units. Therefore, accelerometer time series data must be integrated once prior to calculating the overall velocity value, and then again prior to calculating the overall displacement value. Other sensors are available that collect data directly in velocity units (e.g. velocity coils) or in displacement units (e.g. proximity probes), but the Fluke 805 FC and 810 exclusively use accelerometers. In summary, when performing overall vibration analysis, always be careful to utilize the same calculation method (peak vs. RMS) and units (acceleration vs. velocity vs. displacement) when comparing two values. Here is an example plot that shows a trend of Overall Vibration as the machine health worsens. 0.7 0.6 Overall Vibration 0.5 0.4 0.3 0.2 0.1 0 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT Time Domain vs. Frequency Domain The RMS value of a vibration signal can actually be calculated in the time domain or the frequency domain. The equation above shows how to calculate in the time domain. Parseval s theorem guarantees that we would obtain the same exact value if we calculated the RMS value in the frequency domain as follows: where X(f) is simply the fourier transform of the time series signal x(t). 6 Fluke Corporation Overall vibration, severity levels and crest factor plus

Appendix 2: Crest factor plus technical description Here is an example graph that shows ordinary crest factor varying from 3 to 7 and back to 4 as bearing wear worsens, whereas CF+ increases steadily from 3 to 12 as the bearing damage worsens. 14 12 10 8 6 CF CF+ 4 2 0 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT 7 Fluke Corporation Overall vibration, severity levels and crest factor plus

Appendix 3: List of machine categories for the Fluke 805 FC CHILLERS (Refrigeration) Reciprocating (open motor and compressor separate) Reciprocating (hermetic motor & compressor) Centrifugal (hermetic or open motor) Fans Belt-driven fans 1800 RPM to 3600 RPM Belt-driven fans 600 RPM to 1799 RPM General direct drive fans (direct coupled) Vacuum blowers (belt or direct drive) Large forced draft fans (fluid film bearings) Large Induced Draft Fans (fluid film bearings.) Shaft-mounted integral fan (extended motor shaft) Axial flow fans (belt or direct drive) Cooling tower drives Long, hollow drive shaft (motor) Belt drive (motor & fan) Direct drive (motor & fan) Centrifugal pumps Vertical pumps (12 to 20 Height)* Vertical pumps ( 8 to 12 Height)* Vertical pumps ( 5 to 8 Height)* Vertical pumps ( 0 to 5 Height)* Direct coupled Horizontal centrifugal end suction pumps Horizontal centrifugal double suction pumps Turbine or motor driven Boiler feed pumps * Height from grade to top motor bearing, may be necessary to specify lower alarm for the lower motor bearing and for upper pump bearing (depending on height). Positive displacement pumps Positive displacement horizontal piston pumps (Under Load) Positive displacement horizontal gear pumps (Under Load) Air compressors Reciprocating Rotary screw Centrifugal with or without external gearbox Centrifugal internal gear (axial meas.) Centrifugal internal gear (radial meas.) Blowers Lobe-type rotary blowers (belt or direct drive) Multi stage centrifugal blowers (direct drive) Generic gearboxes (Rolling element bearings) Single stage gearbox Machine tools Motor Gearbox input Gearbox output Spindles roughing operations Spindles machine finishing Spindles critical finishing Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com 2013-2017 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 3/2017 4314907c-en Modification of this document is not permitted without written permission from Fluke Corporation. 8 Fluke Corporation Overall vibration, severity levels and crest factor plus