Model 7600(M)/7602(M) Wideband Power Am pli fier DC to 1MHz 141V/282V rms 17/34 Watts. Op er at ing and Main te nance Man ual

Similar documents
COHU, INC. Elec tron ics Di vi sion In stal la tion and Op era tion In struc tions

De voted to Prof. Pavel Povinec 65-th an ni ver sary. 241 Am source was used in the test cham ber. The beam was collimated by me chan i cal

Op er at ing In struc tions

Telex. RadioCom TM. Op er at ing In struc tions FM-1 QSB-1 SMP. Professional Wireless Intercom System Management

User Manual. DIGIspy. Firmware B3.07 DIGITAL AUDIO TRANSMISSION ANALYZER. Protocols. Transmission Errors. Audio Levels. Audio Signals.

AGASTAT 2100 Series, Miniature Electropneumatic Timing Relay

clipping; yellow LED lights when limiting action occurs. Input Section Features

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

TA2000B-x GHz Fast Pulse / Timing Preamplifier User Manual

SM In ter faces

200 Se ries Communications Head sets


ScopeMeter 190 Series Specifications

Technical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

Instruction Manual Model # Block Upconverter

UNIFORM PRIVATE LAW CONVENTIONS AND THE LAW OF TREATIES

12 Channel Media Splitter MS12 Mk2 User manual

Data Pattern Generator

Advanced Test Equipment Rentals ATEC (2832)

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR AUTOMATIC VIDEO CORRECTOR TEKTRONIX, MODEL 1440 (NSN )

WVR500 Waveform/Vector Monitor

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

USER MANUAL. Blackburst, Sync, Audio Tone Generator. For Models BSG-50, RM-50/BSG, SR-50/BSG. Doc Rev. F (C) Copyright 2014

Please take a few minutes to read this manual so that you will better understand the featues and capabilities of your MF80. MF80 Owner s Manual 1

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

R&S RT-Zxx High-Bandwidth Probes Specifications

Clamp 200 A AC/DC (+ V AC/DC + Ω)

Using an oscilloscope - The Hameg 203-6

TDS 520B, TDS 540B, TDS 620B, TDS 644B, TDS 680B, TDS 684B, TDS 724A, TDS 744A, & TDS 784A

Distribution Unit. User Guide

Model /29S RF Splitter

TSG 90 PATHFINDER NTSC Signal Generator

Specifications. Reference Documentation. Performance Conditions

Sept. 16, 1969 N. J. MILLER 3,467,839

Instruction Manual Model BlockUpconverter

College of MUSIC. James Forger, DEAN UNDERGRADUATE PROGRAMS. Ad mis sion as a Ju nior to the Col lege of Mu sic

Advanced Test Equipment Rentals ATEC (2832)

CR-6 MIXER USER MANUAL ENGLISH. Order Code: MIXE01

Single-Output 2000 W

University of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope

Noise Detector ND-1 Operating Manual

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

DA : Series of Narrowband or Wideband Distribution Amplifiers

Waveform Monitor/Vectorscope, PM 5661 Waveform Monitor/Vectorscope, Sc-H, PM 5661/70

Sphinx II. Owner s Manual. Tube Hybrid Integrated Power Amplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 08/01/16

PicoScope 6407 Digitizer

CPH-10 SUBWOOFER OWNERS MANUAL

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

University of Utah Electrical Engineering Department EE1050/1060 Oscilloscope. Name:, Lab TA:

OPERATING INSTRUCTIONS FOR SYLVANIA. Type I08 Cathode-Ray Oscilloscope. Sylvania Electric Products Inc. Industrial Apparatus. Emporium, Pennsylvania

2 MHz Lock-In Amplifier

DA E: Series of Narrowband or Wideband Distribution Amplifiers

Agilent 5345A Universal Counter, 500 MHz

PicoScope 6407 Digitizer

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

USER MANUAL Goldmund PH3.8 Phono Preamplifier

32 Channel CPCI Board User Manual

ModWright Instruments, Inc. PH 150 Tube Phono Stage Owner s Manual

Instructions. P MHz 1X/10X Passive Probe

Metal Electrode Meter

T L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

UTP ACTIVE TRANSCEIVER HUB

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Procurement of IC TESTER & TRAINER KITS, OSCILLOSCOPES, FG S, DECADE BOXES AND ANALOG METERS

AMU2-2MHD+ Audio monitoring Unit

Advanced Test Equipment Rentals ATEC (2832)

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

PM 6680B / PM 6681 / PM 6681R

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

CONVI104 SWITCHER & ANALOG TO SDI CONVERTER CONVI 104-M 15/03/2006

English. User Manual sub8 Subwoofer SUBWOOFER. Supporting your digital lifestyle

Microwave Counter, Power Meter and DVM in One Portable Package

Chameleon Labs Model 7720

ECP1 MC / MM PHONO PREAMPLIFIER OWNERS MANUAL

Ventilated Distribution Transformers 6

TABLE OF CONTENTS. 1) Introduction 2. 2) Unpacking the Ares 2. 3) Installing the Ares in your system 3. 4) Setting the Operational Parameters 4

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

INSTRUCTION MANUAL PELLAR PHONO PRE-AMPLIFIER. Extended 5-Year Warranty

This Level 3 amplifier features Audio Note Silver wire and Audio Note signal capacitors. UNPACKING AND INSTALLATION

RoHS. Atma-Sphere Music Preamplifier. model P-2 OWNER'S MANUAL. Please study this document carefully before using equipment

SAWM60 AUDIO/VIDEO MODULATOR

Modular Block Converter Systems

G.R.A.S. Sound & Vibration

FREQUENCY COUNTERS TO 18 GHZ USING THE DATUM FREQUENCY STANDARD

MICROWAVE MEASURING INSTRUMENTS

Assembly Level Service Guide

Agilent Technologies 54522A

Frequency. Range. HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz. Standard 10 MHz timebase: f10 ppm

GFT Channel Digital Delay Generator

USER MANUAL GOLDMUND PH3 Phono Preamplifier

R&S RT-Zxx High-Voltage and Current Probes Specifications

RMX-44 & RMX-62 MIXING MATRIX. Installation & Operation Manual

Transcription:

Model 7600(M)/7602(M) Wideband Power Am pli fier DC to 1MHz 141V/282V rms 17/34 Watts Op er at ing and Main te nance Man ual

Ser vice and War ranty Krohn-Hite Instruments are designed and manufactured in accordance with sound engineering practices and should give long trou ble-free ser vice un der nor mal op er at ing con di tions. If your in stru ment fails to provide satisfactory service and you are unable to locate the source of trouble, contact our Service Department at (508) 580-1660, giving all the information available concerning the failure. DO NOT return the instrument without our written or verbal authorization to do so. After contacting us, we will is sue a Re turn Au tho ri za tion Num ber which should be ref er enced on the pack ing slip and pur - chase or der. In most cases, we will be able to sup ply you with the in for ma tion nec es sary to re pair the in - stru ment, avoid ing any trans por ta tion prob lems and costs. When it be comes nec es sary to return the in strument to the fac tory, kindly pack it care fully and ship it to us pre paid. All Krohn-Hite prod ucts are war ranted against defective materials and workmanship. This warranty applies for a pe riod of one year from the date of de liv ery to the Orig i nal Pur chaser. Any in stru ment that is found within the one year war ranty pe riod not to meet these stan dards, will be re paired or re placed. This war ranty does not ap ply to elec tron tubes, fuses or bat ter ies. No other war ranty is ex pressed or im plied. Krohn-Hite Cor po ra tion re serves the right to make de sign changes at any time with out in cur ring any ob liga tion to in cor po rate these changes in in stru ments pre vi ously pur chased. Modifications to this instrument must not be made without the written consent of an authorized employee of Krohn-Hite Corporation.

Model 7600(M) and 7602(M) Wideband Power Am pli fier DC to 1MHz, 17W and 34W Se rial No. Op er at ing and Main te nance Man ual Beijing Torion Trading Co.,Ltd. Tel: 13801253818; Fax: 010-84067150 Email: sales@torion.cn Ser vice: sales@torion.cn www.torion.cn Copy right 2004 Krohn-Hite Cor po ra tion. All rights re served. Contents of this publication may not be reproduced in any form without the written perrmission of Krohn-Hite Corporation. Printed 5-04, Rev 3.1

Model 7600 Model 7602 Model 7600M ("M" is the Me ter Op tion Pack age) Model 7602M ("M" is the Me ter Op tion Pack age)

Ta ble of Con tents 1.0 GEN ERAL DE SCRIP TION 1-1 1.1 IN TRO DUC TION 1-1 1.1.1 Ship ping to Krohn-Hite for Re pair or Cal i bra tion...1-1 1.2 SPEC I FI CA TIONS 1-1 1.2.1 OUT PUT (All rms val ues are for sinewave sig nals)......... 1-1 1.3 IN PUT 1-3 1.4 GEN ERAL 1-3 1.5 OP TIONS 1-4 2.0 OP ER ATION 2-1 2.1 IN TRO DUC TION 2-1 2.2 POWER RE QUIRE MENTS 2-1 2.3 TURN-ON PRO CE DURE 2-1 2.4 OP ER A TION 2-3 2.4.1 Front Panel.................................. 2-3 2.4.1.1 Power Switch 2-3 2.4.1.2 Mode 2-3 2.4.1.3 AC/DC Cou pling 2-3 2.4.1.4 Gain db 2-4 2.4.1.5 Vari able Gain db Con trol 2-4 2.4.1.6 DC Off set 2-4 2.4.1.7 Variable DC Offset Control 2-4 2.4.1.8 Me ter Se lect Switch (Me ter Op tion) 2-4 2.4.1.9 Con nec tors 2-5 2.4.1.10 Out put Dis con nect/ Con nect Switch 2-5 2.4.1.11 LED In di ca tors 2-5 I

2.4.2 Rear Panel................................... 2-5 2.4.2.1 Op tion 002 Con nec tors 2-5 2.4.2.2 Chas sis/float ing Ground Switch 2-5 2.4.2.3 Fuse Re cep ta cle 2-6 2.4.2.4 AC Power Re cep ta cle 2-6 2.4.2.5 Line Switches 2-6 3.0 IN COM ING AC CEP TANCE 3-1 3.1 IN TRO DUC TION 3-1 3.2 TEST EQUIP MENT RE QUIRED 3-1 3.3 IN COM ING PRO CE DURE 3-1 3.3.1 DC Off set and Peak Volts Me ter Cal i bra tion Check......... 3-1 3.3.2 Squarewave Broad Band ing Check................... 3-2 3.3.3 Squarewave Rise And Fall Time Check................. 3-3 3.3.4 Slew Rate Check............................... 3-3 3.3.5 Gain Cal i bra tion Check.......................... 3-4 3.3.6 Fre quency Re sponse Check........................ 3-4 3.3.7 1K Load Max i mum Power......................... 3-5 3.3.8 Dis tor tion Check............................... 3-6 ii

Model 7600/7602 Section 1 - General Description SECTION 1 GENERAL DESCRIPTION 1.1 IN TRO DUC TION The Model 7600 and 7602 are 17 watt and 34 watt wideband power am pli fi ers that of fer ex tended out put power and volt age ca pa bil i ties, low dis tor tion, ver sa til ity and the lat est in hy brid CMOS power op er a- tional amplifier technology, with performance features not available in other power amplifiers. The unit pro vides 17 watts of con tin u ous power (34 watts at dc) and 141V rms from dc to 500kHz. The frequency re sponse is ±0.1dB to 10kHz, and the dis tor tion con trib uted by the am pli fier is <0.01% to 5kHz and <0.3% to 100kHz. The volt age gain can be ei ther in vert ing or non-in vert ing and has selectable ranges from 0dB to 14dB, 14dB to 28dB and 28dB to 42dB (a volt age gain step of 5), and is con tin u ously vari able be tween the ranges. Other fea tures in clude: modes of A, A B and B; com mon mode re jec tion of 80dB; in put cou pling of ac or dc; a meter that is selectable to display heat sink temperatures in C, output peak voltage and average output cur rent. A dc off set con trol is also pro vided that is vari able from 0V to ±200V. The Model 7602 provides the same capabilities as the Model 7600 but also provides a balanced output and is able to de liver 34 watts of con tin u ous power (68 watts at dc), and 282V rms (800V p-p). It can also pro - vide plus and mi nus volt ages simultaneously. Claim for Dam age in Ship ment to Pur chaser The Model 7600 and 7602 are care fully in spected, tested and aged be fore ship ment to en sure that it is work ing prop erly. The unit should be thoroughly inspected immediately upon ar rival to pur chaser. All items shipped should be checked against the en closed pack ing list. Krohn-Hite will not be re spon si ble for shortages against the packing list unless notified immediately. If for some reason the in strument is not work ing prop erly, or ap pears to have been dam aged in ship ment, in form the freight car rier and file a claim for the dam age, then no tify Krohn-Hite or its near est sales of fice immediately (to obtain a quotation to repair the ship ment dam age). The fi nal claim and ne go ti a tions with the car rier must be com pleted by the customer. 1.1.1 Ship ping to Krohn-Hite for Re pair or Cal i bra tion All ship ments of Krohn-Hite in stru ments should be made via United Par cel Ser vice or Best Way pre - paid. The instrument should be shipped in the original shipping container; or if not available, use any suitable con tainer that is rigid and of ad e quate size. If a sub sti tute con tainer is used, the unit should be wrapped in pa per and sur rounded with at least four inches of shock-ab sorb ing ma te rial. 1-1

Section 1 - General Description Model 7600/7602 1.2 SPEC I FI CA TIONS 1.2.1 OUT PUT (All rms val ues are for sinewave sig nals) For the Model 7602, specifications apply to each output to ground. Frequency Range: dc to 1MHz. Power Voltage 1k Ohm Load: 17W rms, 34W dc and peak, dc to 500kHz; 5W rms to 1MHz. 600 Ohm Load: 10W rms, 100Hz to 1MHz; 5W rms, 10W dc and peak, dc to 100Hz. No Load: ±200V dc and peak, 141V rms. 1k Ohm Load: ±184V dc and peak, 130V rms, dc to 500kHz; ±113V peak, 80V rms at 1MHz. 600 Ohm Load: ±113V peak, 80V rms, 100Hz to 1MHz; ±78V dc and peak, 55V rms, dc to 100Hz. Current: 910 ohm load, ±200mA peak, 141mA rms, dc to 500kHz. Frequency Re sponse: ±0.1dB, dc to 10kHz; ±0.25dB to 200kHz; ±0.5dB to 500kHz, 0-130V rms; ±0.5dB to 1MHz 0-80V rms. Harmonic Distortion: <0.01% to 5kHz and 175V peak out put; <0.05% to 200V peak; <0.3% to 100kHz. Voltage Gain: 0dB to 42dB in three ranges; 0dB to 14dB, 0dB to 28dB, 0dB to 42dB; con tin u ously vari - able be tween ranges. Step Ac curacy: ±0.1dB plus fre quency re sponse spec i fi ca tion. Gain steps are 14dB at max vari able gain con trol set ting or a volt age gain of 5. Stability: <0.001dB change for a 10% change in line volt age. Dynamic Range: >80dB. Hum and Noise (2MHz band width): re ferred to out put, <10mV rms; <20mV rms on the 0dB to 42dB gain range. Phase Shift: A in put 0 ±1, B in put, 180 ±1 dc to 10kHz in creas ing lin early 60 lag ging at 1MHz. Model 7602: (In verted out put rel a tive to non-in verted) 180, 0.3 at 10kHz; 180, 3 at 100kHz; 180, 20 at 1MHz. Squarewave Re sponse Rise/Fall Times: 120ns to 50Vp-p. Slew Rate: >600V/μs, 400Vp-p. Aberrations: <5%. 1-2

Section 1 - General Description Regulation: <0.1%, No load to 1k ohm load, dc to 10kHz, ris ing to 2% at 1MHz. Coupling: DC. DC Level: Nominal zero volts; vs. temperature, 2mV/ C. DC Off set Con trol (no load): 0V to ±200V. DC Level Sta bil ity Vs. Line: <1mV for a 10% change in line volt age. Vs. Temperature: <0.01%/ C or 2mV/ C whichever is greater. Internal Impedance: <0.5 ohms, dc to 10kHz; 5 ohms at 100kHz; 20 ohms at 1MHz. Output Protection: Pro tected from over loads with a unique foldback lim iter which keeps the out put cur - rent within safe op er at ing re gions. Kick back di odes clamp kick back volt ages to the sup ply. 1.3 IN PUT Modes: A, A B, B. Maximum Volt age (without damage): ±200V dc referred to ground. Maximum Common Mode: 0dB to 14dB range, ±200V peak; 14dB to 28dB range, ±40V peak; 28dB to 42dB range, ±8V peak. Common Mode Rejection: 80dB, dc to 200Hz; 60dB to 1kHz; 40dB to 10kHz; ris ing to 20dB at 1MHz. Sensitivity: ±1.6V peak. Coupling: Direct (dc) or capacitive (ac) with low frequency cutoff of approximately 1Hz. Impedance: 1 Meg ohm in par al lel with 30pF with front in puts only; 65pF with front and op tional rear in - puts, independent of input gain setting. 1.4 GEN ERAL Load Impedance: Capable of driving any resistive load within the current and voltage limitations of the amplifiers foldback lim iter. Ca pable of driving reactive loads within voltage and current limitations. Temperature Range: 0 C to 45 C. Controls Front panel: Power switch, 5-position input MODE switch, 2-position INPUT COUPLING switch, 3-position GAIN control switch, variable GAIN db potentiometer, 10-turn variable DC OFFSET potentiometer, 3-position offset RANGE switch, 4-position METER SELECT switch, output CON- NECT/DISCONNECT switch. Rear panel: CHAS SIS/FLOAT GROUND switch. 1-3

Section 1 - General Description Front Panel Warn ing LED Indicators: Over TEMP, CLIP PING, out put H.V. (high volt age). Terminals: BNC A in put, BNC B in put, bind ing post out put. Rear Panel: Power receptacle, optional BNC A input, B input and binding post output. Power Requirements: 90-132/198-264 volts, 50Hz-400Hz, 200 watts. Dimensions and Weights: 3 1 2 (9cm) high, 8 1 2 (21.8cm) wide, 18" (46ttttttttt.2cm) deep; 12 lbs (5.4kg) net, 14 lbs (6.3kg) ship ping. Accessories: 3-terminal line cord, operating manual. 1.5 OP TIONS 7600M/7602M Me ter - Op tion Pack age Heat Sink Temp C: Measures the heat sink temperature in the vicinity of the output power amplifier IC. Used as an indicator of operating conditions and air flow to the unit. Output Peak Voltage: Mea sures the larg est peak volt age in de pend ent of po lar ity with a 1 sec ond time con stant. Accuracy (at 1kHz): ±0.5V. Frequency Response: ±2%, 10Hz to 100kHz; 5% to 1MHz. Average Output Cur rent: Mea sures av er age dc sup ply cur rent delivered to the output amplifier as an indicator of output amplifier load. Quiescent current is nulled out. Can be used to find resonances in a load. Accuracy: ±5% ±1 digit. Rack Mount ing Kit: Part No. RK-37, per mits installation of the Models 7600/7602 into a standard 19" rack spac ing. Option 003: Rear panel input and output connectors. 1-4

Section 2 - Operation SECTION 2 OPERATION 2.1 IN TRO DUC TION This sec tion de scribes the op er a tion of the Model 7600 and 7602. It in cludes the proper ac re quire ments, the rec om mended turn-on pro ce dure and a de tailed explanation of all the operating controls. 2.2 POWER RE QUIRE MENTS The Model 7600 and 7602 Power Am pli fier is de signed to op er ate from a sin gle-phase, 50Hz to 400Hz ac power source of 90 to 110, 108 to 132, 198 to 242 or 216 to 264 volts. The LINE SWITCH lo cated on the rear panel al lows the unit to be pow ered from one of the four volt age ranges above. The ac power re cep tacle is a standard 3-pin connector and complies with the European I.E.C. standard. A detachable 3-wire line cord is pro vided with the unit. 2.3 TURN-ON PRO CE DURE 1. Set the LINE SWITCHES for the de sired range. For the 90 to 110 volt range, set the volt age range switch to 120V and the NORM/LOW switch to LOW. For the 108 to 132 volt range, set the volt age range switch to 120V and the NORM/LOW switch to NORM. For the 198 to 242 volt range, set the volt age range switch to 240V and the NORM/LOW switch to LOW. For the 216 to 264 volt range, set the volt age range switch to 240V and the NORM/LOW switch to NORM. 2. Ob serve that the POWER switch is in the off po si tion. 3. To se lect the de sired ground ing, switch the CHAS SIS/FLOATING GROUND slide switch lo cated on the rear panel to the proper set ting. WARNING The chas sis of the Model 7600 and 7602 can be con nected to signal ground via the CHAS SIS/FLOATING GROUND switch. For safety pur poses, con nect the line cord to a 3-ter mi nal ac out let. 2-1

Section 2 - Operation 4. Plug the line cord into the unit and then into the ac out let. 5. Turn the POWER switch on and al low the unit to warm-up for sev eral min utes. CAU TION Be cause of po ten tially dan ger ous volt age within the Model 7600 and 7602, the cov ers should not be re moved when the unit is con - nected to an ac out let, un less it is by qual i fied per son nel. The Model 7600 and 7602 is now ready to am plify. 2.4 OP ER A TION To op er ate the Model 7600 and 7602 Power Am pli fier, pro ceed as fol lows: 1. Make the appropriate power connections ( refer to TURN-ON Procedure). 2. Set the DC OFF SET switch to the OFF po si tion. 3. Set the GAIN db switch to 0dB. 4. Set the MODE switch to OFF. 5. Set the In put Cou pling switch to the de sired mode (AC or DC). 6. Set the METER SE LECT switch to the PEAK VOLTS po si tion. 7. Connect a voltmeter to the OUTPUT ter mi nals and check for 0V dc. Allow the unit to warm-up for 30 minutes to obtain rated performance specifications. CAU TION The Model 7600 and 7602 is ca pa ble of as much as 200V peak (7600) and 400V peak (7602) on its OUT PUT ter mi nals. To pre - vent the possibility of electrical shock, set the OUTPUT connect switch to DISCONNECT when connecting or disconnecting any ca ble or load from the am pli fier s OUT PUT ter mi nals. 2-2

Section 2 - Operation 2.4.1 Front Panel Fig ure 2.1 Model 7600M with Me ter Op tion Pack age Fig ure 2.2 Model 7602M with Me ter Op tion Pack age 2.4.1.1 Power Switch I is the ON po si tion, 0 is the OFF po si tion. 2-3

Section 2 - Operation 2.4.1.2 Mode The MODE se lec tor switch con sists of a 5-po si tion, ro tary switch that se lects the Mode of op er a tion. The following are a description of each position: OFF: When se lected, there will be no sig nal at the OUT PUT ter mi nals. A: When se lected, the in put sig nal will be non-in verted (in-phase) at the (sinewave) OUT PUT ter mi nal and in verted at the (in verted sinewave) OUT PUT ter mi nal. B: A B: When se lected, the in put sig nal will be in verted at the (sinewave) OUT PUT ter mi nal and non-in verted at the (in verted sinewave) OUT PUT ter mi nal. When se lected, the out put sig nal will be the math e mat i cal dif fer ence be tween each in put sig nal. 2.4.1.3 AC/DC Cou pling The AC/DC switch is a 2-po si tion ro tary switch with two selectable set ting: AC (ca pac i tive cou pling) or DC (di rect cou pling). In the AC po si tion, the low-cut off fre quency is ap prox i mately 1Hz. 2.4.1.4 Gain db The GAIN db switch con sists of a 3-po si tion ro tary switch with three ranges. A min i mum sig nal of 1.6V peak must be applied to the input in order to obtain the maximum output voltage of 200V peak. When used with the variable GAIN control, each position can be varied as follows: 0dB: 0dB to 14dB 14dB: : 0dB to 28dB 28dB: : 0dB to 42dB 2.4.1.5 Vari able Gain db Con trol The Variable Gain db Control is a single-turn potentiometer that has an overall gain of 5 at each range of the GAIN db range switch de scribed in para graph 2.4.1.2 above. Note When the Vari able Gain db Con trol is in the max i mum CCW po si tion, the am - plifier s output termi nals will still have a voltage or signal on them. In order to not have this con di tion oc cur, the MODE switch must be set in the OFF po sition, the Out put DIS CON NECT/CON NECT switch must be set to the DIS - CONNECT position, or the input signal must be removed. 2.4.1.6 DC Off set The DC OFF SET switch con sists of a 3-po si tion ro tary switch with three selectable set tings: 200, OFF and +200. When used with the vari able DC OFF SET con trol, the dc off set can be var ied from 0V to 200V dc and 0V to +200V dc. 2-4

Section 2 - Operation 2.4.1.7 Vari able DC Off set Con trol The Variable DC OFFSET Control consists of a 10-turn potentiometer that infinitely controls the Output DC Off set 0V to 200V peak or 0V to +200V peak. 2.4.1.8 Me ter Se lect Switch (Me ter Op tion) The Me ter Se lect Switch is a 4-po si tion ro tary switch that al lows the LED panel me ter to in di cate the fol - low ing: Heat Sink Temp C: Peak Volts: Av er age (I) +Sup ply: Av er age (I) Sup ply: In di cates the tem per a ture of the heat sink at the out put am pli fi ers. It gives the user a mon i tor ing de vice when the am pli fier is in an en vi ron ment that is not well ven ti lated. In di cates the out put peak volt age. In di cates the av er age cur rent of the plus sup ply. In di cates the av er age cur rent of the mi nus sup ply. 2.4.1.9 Con nec tors BNC con nec tors are pro vided for the In put sig nal, and Bind ing Posts are pro vided for the Out put sig nal. A Input BNC: Sensitivity is 1.6V peak. A signal of ±1.6V peak is needed to achieve maximum output. Ac tive when the MODE switch is se lected to the A or A B po si tions. B Input BNC: Sensitivity is 1.6V peak. A signal of ±1.6V peak is needed to achieve maximum output. Ac tive when the MODE switch is se lected to the B or A B po si tions. 2.4.1.10 Out put Dis con nect/ Con nect Switch I is the ON po si tion, 0 is the OFF po si tion. 2.4.1.11 LED In di ca tors Temp: Indicates the heat sink temperature has exceeded 57 C (with Meter option Package only). Clipping: Indicates when the output is beginning or actually clipping. >15V: Indicates when the output voltage is >15V (with Meter Option Package only). 2-5

Section 2 - Operation 2.4.2 Rear Panel 2.4.2.1 Op tion 002 Con nec tors BNC con nec tors are pro vided for the In put sig nal, and Bind ing Posts are pro vided for the Out put sig nal. Fig ure 2.1 Rear Panel Panel 2.4.2.2 Chas sis/float ing Ground Switch The CHASSIS/FLOATING GROUND switch is a 2-position slide switch that disconnects the amplifier s sig nal ground from its chas sis ground when used in the FLOAT ING mode. 2.4.2.3 Fuse Re cep ta cle The am pli fier s fuse rat ing is a 3A slow-blow for both 120V and 230V op er a tion. 2.4.2.4 AC Power Re cep ta cle The AC power receptacle is a standard 3-wire AC con nector. 2.4.2.5 Line Switches A de scrip tion of the AC line switches are in para graph 2.3. 2-6

Section 3 - Incoming Acceptance SECTION 3 INCOMING ACCEPTANCE 3.1 IN TRO DUC TION The following procedure should be used to verify that the Model 7600 and 7602 is operating within specifi ca tions., both for in com ing in spec tion and rou tine ser vic ing. Tests should be made with the cov ers in place, and the pro ce dure given be low should be fol lowed in se quence. 3.2 TEST EQUIP MENT RE QUIRED a. DC volt meter capable of measuring 1mV to 200V with 0.1% accuracy at 200V. Fluke Model 8010A or equivalent. b. AC Volt me ter ca pa ble of mea sur ing 100mV to 150V rms with a 1MHz band width. Fluke Model 8920A rms volt meter or equivalent. c. Dual Chan nel Os cil lo scope with X10 probes and a 50MHz band width. Tektronix Model 2245A or equivalent. d. 1000 ohm dummy load capable of dissipating 40 Watts. e. Sinewave source from 10Hz to 1MHz. Krohn-Hite Model 4200B/4300B or equiv a lent. f. Sinewave source with <0.01% dis tor tion at 1kHz. Krohn-Hite Model 4400A or equiv a lent. g. Squarewave source from 1kHz to 200kHz with 40ns rise and fall time and 5% ab er ra tions. Krohn-Hite Model 4300 or equiv a lent. h. Dis tor tion an a lyzer that can mea sure down to 0.005%. Krohn-Hite Model 6900B or equiv a lent. In the fol low ing pro ce dure the main out put is marked with a sinewave and the in verted out put is marked with an in verted sinewave on the front panel. 3.3 IN COM ING PRO CE DURE 3.3.1 DC Off set and Peak Volts Me ter Cal i bra tion Check Set the MODE to OFF. Set ME TER SELECT to PEAK VOLTS. Con nect the DVM to the main out put. Set the DC OFF SET con trol to +200 po si tion. Ad just the off set con trol pot for a +199.0V read ing on the DVM. 3-1

Section 3 - Incoming Acceptance The 7600/7602 me ter should read 199.0V ±0.5V. For the 7602 mea sure the in verted out put for 199.0V ±0.4V. Set the DC OFF SET to 200 po si tion. Ad just the off set con trol pot for a 199.0V read ing on the DVM. The 7600/7602 me ter should read 199.0V ±0.5V. The High Volt age LED should be lit and the CLIP PING LED out for both po lar i ties of out put off set. Re duce the DC off set us ing the off set con trol pot un til the HV LED goes out. The volt age it goes out at should be 12V to 15V. Dis con nect the DVM from the 7600/7602. 3.3.2 Squarewave Broad Band ing Check The CLIP PING LED should not come on dur ing steps 2 and 3. Con nect a 1kHz, 2.0V p-p (1.0V peak) squarewave to the A and B in puts. Set the os cil lo scope gain for 0.5V/cm with probes on both chan nels. Con nect both os cil lo scope chan nels one and two through X10 probes (probe must be broad banded) to the input signal and adjust them to give an optimum matched waveform. Connect oscilloscope channel two to the main output. Set scope gain on chan nel two to 10V/cm, DC cou pled. Set the 7600/7602 for AC cou pling and a gain of 28dB (GAIN db to 28, gain pot to 0 end stop), MODE to A. The wave form on the os cil lo scope should be 50V p-p (5 cm). Waveform aberrations such as droop, slant or over shoot should be less than 2.5V or 0.25cm. Adjust the oscil lo scope vari able gain con trol knob so that the out put am pli tude dis played matches the in put am pli tude. The two wave forms should look the same within 0.2cm. Set the MODE to B. Set the oscilloscope channel two invert on. The two wave forms should look the same within 0.2cm. Set the GAIN db for 14. Set the chan nel one gain to 2V/cm. Set the 1kHz square wave form am pli tude to 10.0V p-p (5.0V peak). Readjust the oscilloscope channel two variable gain control so that the output amplitude displayed matches the input amplitude. The two wave forms should look the same within 0.2cm. 3-2

Section 3 - Incoming Acceptance Set the MODE to A. Set the oscilloscope channel two invert off. The two wave forms should look the same within 0.2cm. Set the GAIN db for 0, gain con trol pot to 0 end stop. The two wave forms should look the same within 0.2cm. Set the MODE to B. Set the oscilloscope channel two invert on. The two wave forms should look the same within 0.2cm. For the 7602 con nect the scope to the in verted out put. Set the oscilloscope channel two invert off. The two wave forms should look the same within 0.2cm. Re con nect the scope to the main out put. 3.3.3 Squarewave Rise And Fall Time Check Con nect the scope probe to the main out put and set it s gain for 10V/cm, vari able gain con trol pot to cal. po si tion. Set the in put squarewave fre quency to 200kHz. Set the in put am pli tude to 2.0V p-p (1.0V peak). Set the 7600/7602 GAIN db for 14, am pli tude con trol pot to 14 end stop. Set the scope sweep time to 0.5mS/cm. Set the scope for neg a tive slope trig ger. One full cy cle of a 50V p-p square wave should be on the screen with the ris ing edge in the cen ter of the screen. The wave form ab er ra tions should be <5% or 2.5V ( 1 4cm). Set the sweep X10 mag ni fier on and recenter the ris ing edge us ing the hor i zon tal po si tion con trol. Mea sure the rise time from the 10% to the 90% points on the ris ing edge. It should be <120ns (2.4cm). Set the scope trig ger to pos i tive slope. Locate the falling edge using the horizontal position control. Mea sure the fall time from the 90% to the 10% points on the fall ing edge. It should be <120nsec (2.4cm). For the 7602 re peat the step for the in verted out put. 3-3

Section 3 - Incoming Acceptance 3.3.4 Slew Rate Check Set the MODE to A. Set the GAIN db for 28, gain con trol pot for 0 end stop. Set the scope sweep X10 mag ni fier to off. Set the scope gain to 50V/cm. Set the sweep time to 1mS/cm. Set the in put squarewave fre quency to 200kHz. Set the input amplitude to 3.0V p-p. The out put am pli tude should be 375V p-p. Set the sweep X10 Mag on. Mea sure the ris ing edge slew time from the 150V point on the scope (3rd cm be low cen ter line) to the +150V point (3rd cm above cen ter line). It should be ms (5cm). Set the scope trig ger slope to neg a tive. Mea sure the fall ing edge slew time from the +150V point on the scope (3rd cm above cen ter line) to the 150V point (3rd cm be low cen ter line). It should be <0.5mS (5cm). For the 7602 re peat the step for the in verted out put. 3.3.5 Gain Cal i bra tion Check Set the input waveform to sine wave and connect it to both A and B inputs using two T adapters. Set the in put sig nal to a 1kHz. Set the input amplitude to 1V p-p. Con nect the scope to the out put(s) set for a gain of 20V/cm. Con nect the Fluke model 8920A true RMS volt me ter to the in put via a T adapter. Set it for db rel a tive op er a tion. Zero reference the meter. Set the 7600/7602 for: MODE B and AC. GAIN db to 28 and gain con trol pot to 0 end stop. DC OFF SET OFF. ME TER SE LECT to PEAK VOLTS. 3-4

Section 3 - Incoming Acceptance The wave form on the scope should be a clean sinewave. With the Fluke zero ref er enced on the in put con nect the Fluke to the main out put. Mea sure the gain. It should be 42dB ±0.1dB. For the 7602 mea sure the gain to the in verted out put. It should be 42dB ±0.1dB. The 7600/7602 me ter should read 62.5 ±0.5. Set the db GAIN con trol to 14. The Fluke me ter should read 28dB ±0.1dB. The 7600/7602 me ter should read 12.5 ±0.5. Set the db GAIN con trol to 0. The me ter should read 14dB ±0.1dB. The 7600/7602 me ter should read 2.5 ±0.5. Set the 7600/7602 gain con trol pot to the 0 end stop. The me ter should read 0dB ±0.1dB. Re peat the step with the MODE switch set for A. 3.3.6 Fre quency Re sponse Check Use a flat re sponse sig nal source such as a Krohn-Hite Model 4200 os cil la tor for this test. For the 7602 mea sure the in verted out put for each step. Con nect a 1kHz sig nal source to both A and B in puts. Set the in put am pli tude for 4.0V p-p (2.0V peak) or 1.5V rms (its not crit i cal in how pre cise it is). Con nect the Fluke 8920A set to volts to the main out put. The 7600/7602 should be set for: MODE to B and AC. Set db GAIN to 28. Gain con trol pot to 0 end stop. DC OFF SET to OFF. ME TER SE LECT to PEAK VOLTS. Ad just the 7600/7602 gain con trol pot for a 130V ±1V rms read ing on the Fluke. Set the Fluke to db relative operation and zero reference the reading. Set the fre quency to 10kHz and mea sure the change in out put am pli tude on the Fluke. 3-5

Section 3 - Incoming Acceptance Should be <±0.1dB. Set the fre quency to 100Hz. The change in out put am pli tude should be <±0.1dB. Set the fre quency to 200kHz. The change in out put am pli tude should be <±0.25dB. Set the fre quency to 500kHz. The change in out put am pli tude should be <±0.5dB. Re peat the step with the MODE switch set for A. 3.3.7 1K Load Max i mum Power Set the in put sinewave am pli tude to 4V p-p (2V peak or 1.5V rms, not crit i cal) fre quency to 1kHz. Con nect the 1000 ohm dummy load to the main out put. Connect the oscilloscope to the main output. The 7600/7602 should be set for: MODE to A and AC. Set db GAIN to 28. Gain con trol pot to 0 end stop. DC OFF SET to OFF. ME TER SE LECT to PEAK VOLTS. In crease the 7600/7602 gain con trol pot to the point of ob serv able clip ping on the out put. With the Fluke mea sure the rms volt age at which clip ping oc curs. It should be >130V rms. Set the fre quency to 500kHz. In crease the 7600/7602 gain con trol pot to the point of ob serv able clip ping. With the Fluke mea sure the rms volt age at which clip ping oc curs. It should be >130V rms. For the 7602 re peat the step for the in verted out put ex cept the dummy load must be con nected to the in - verted out put. 3-6

Section 3 - Incoming Acceptance 3.3.8 Dis tor tion Check Con nect a low dis tor tion sine wave source such as the Krohn-Hite model 4400 os cil la tor to the A in put. Set the fre quency to 5KHz. Set the input amplitude for approximately 2V RMS. Set the 7600/7602 for: MODE to A and AC. GAIN db for 28, gain con trol pot to 0 end stop. DC OFF SET to OFF. ME TER SE LECT to PEAK VOLTS. Connect the distortion analyzer meter to the main output. Ad just the gain con trol pot for a 175V read ing on the 7600/7602 me ter. The distortion analyzer should read <0.01% dis tor tion. Set the fre quency to 100kHz. Dis tor tion read ing should be <0.1%. 3-7

Section 3 - Incoming Acceptance This page in ten tion ally left blank. 3-8