USER MANUAL Table of Contents Safety Information. 2 Specifications.. 3 Product Overview 4 Power & Signal Connection... 6 Installation... 7 Rigging the Fixture.2 Service...2 Maintenance.3 Parts List... 3 Software 4
Check that the unit has not been damaged during transport Protection against fire. Maintain a minimum of 2 foot distance from any type of flame. 2. Replace fuse only with the specified type and rating. 3. o not install the unit to close to a heat source. 4. Make sure cable are properly secured. 5. Protect the power and data cords from being walked on or pinched Protection against electrical hazards. isconnect power before servicing. 2. For Connection to power supply proceed to page 7 3. This unit must be earthed (electronically) 4. o not expose to rain or moisture. 5. o not extend power supply cable. Protection against mechanical hazards. Use safety chain when hanging unit. 2. Make sure all clips are securely clipped together. 2
47.25 / 200mm Specifications Fixture EL-37-Linx 37.5 Panel Flight Case EL-37case2 Mechanical Specifications Pixel Pitch: 37.5mm.8 / 300mm Section Resolution: Brightness: Viewing Angel: 8x32, 256 pixel per Links 2300C-m2 20 Vertical 20 Horizontal IP Rating: IP 63 Transparency: 57% Connection: OU 5 pin signal connection, OU 2 pin power connection Weight / imensions In:47.25 x.8 x / mm: 200 x 300 x 25 Weight: 5.8lbs Electrical Specifications LE Type: SM tri color Led Quantity: 256 LE Lifetime: Power input Power output 00,000 hours estimated Manually Switchable 0V or 220V Power Consumption: 75 Watts 3
Product Overview LX-37 Enigma LINX The Enigma Linxs is made up of 32 strips that hold 8 LE pixels totaling 256 LE per Links. The connection starts at the top side of the links. Each panel of Links has a male and female mounting connection allowing you to connect to the panel below with a limitation of 8 panels below and 4 across per Links Power river (LX P2). EL-river Enigma Linx rive System 00-240V 50/60 USB ATA OUT A VI INPUT The Enigma Linx rive System is a interface device that will convert the signal that is coming out of your PC s VI output. Into a signal that can be sent to the Enigma Linx Power Sub rive Box 0V AC INPUT ata IN ata ata 2 ata 3 ata 4 ata Out 0V AC EL-P8 Enigma Linx Power Sub rive The Enigma Links Power Sub rive System will connect to the Enigma rive System via Ether Conn Cable and send signal and power to the Linx panel. Power Max limitation is 4 panels across by 2 Panels down. 0V AC INPUT 0V AC EL-P6 Enigma Linx Power Sub rive ata ata 2 ata 3 ata 4 The Enigma Linx Power Sub rive System will connect to the Enigma rive System via Ether Conn Cable and send signal and power to the Linx panel. ata IN ata 5 ata 6 ata 7 ata 8 ata Out Power Max limitation is 4 panels across by 4 Panels down or 6 panels across by 3 Panels down or 8 panels across by 2 Panels down 4
EL-BUM4 / Enigma Linxs4 Unit Bumper EL-BUM2 / Enigma Linx 2 Unit Bumper EL-BUM / Enigma Linx Unit Bumper 5
L L Power Cable Connection Caution!. o not connect Enigma Linx Power supplies to a immer System 2. This unit must be earthed. (electronically grounded) 3. Replace fuse only with the specified type and rating. Power must be internally switched to desired setting. 0V Connection Cable (USA) Cable (EU) Pin Connection Black Brown Live L White Light Blue Neutral N N Green Yellow/Green Ground 220V Connection Cable (USA) Cable (EU) Pin Connection Black White Brown Light Blue Live Live L L L Green Yellow/Green Neutral N N Signal Cable Connection The fixture is equipped with panel mount Neutrik Ether Conn Connection (RJ-45) for signal input and output. 6
Installation The main design advantage to the Enigma Linx is the ability to flexible in use. The unit is designed to be able to hinge on the sides and on the top and bottom giving you the ability to be more creative in your set designs. The Linx is a flexible LE video screen with a solid display performance. The unit can bend, wrap and fold to conform to even the most unusual designs; yet it s equally functional when quickly rolled out to create an even video screen. The Linx ultra thin grid construction gives curtain like flexibility with out the pixel alignment problems of the cloth-based curtain products. urable and light weight, The Linx screen quickly rolls up for shipping and unrolls for rapid installation. Multiple rigging options are available for permanent or temporary installations Curved Mounting Bend Mounting Removed Panels Large Screen 7
Wiring Instructions Install software prior to connecting USB cable Image must come from a digital source not from a converted adapter EL-RIVER 00-240V 50/60 USB ATA OUT A VI INPUT 0/220 AC INPUT ata IN ata ata 2 ata 3 ata 4 ata Out 0/220 AC EL-P8 0/220 AC INPUT 0V maximum of 3 LX-P2 / 220V maximum of 6 LX-P2 ATA Single EL-P8 limitation is 2 Panels own Single EL-P8 limitation is 4 Panels Across 8
Install software prior to connecting USB cable Image must come from a digital source not from a converted adapter EL-RIVER 00-240V 50/60 USB ATA OUT A VI INPUT 0/220 AC INPUT ata ata ata ata 0/220 AC EL-P6 ata IN ata ata ata ata ata 0/220 AC INPUT 0V maximum of 2 LX-P24 / 220V maximum of 2 LX-P24 ATA Single EL-P6 limitation is 4 Panels own with 6 panels total. Single EL-P6 limitation is 8 Panels Across with 6 panels total. 9
Multiple Unit Installation Install software prior to connecting USB cable Image must come from a digital source not from a converted adapter EL-RIVER 00-240V 50/60 USB ATA OUT A VI INPUT 2 own Total 0
Multiple Unit Installation Install software prior to connecting USB cable Image must come from a digital source not from a converted adapter EL-RIVER 00-240V 50/60 USB ATA OUT A VI INPUT 4 own Total
Rigging the fixture Caution!. The installations must be carried out by an authorized dealer or trained professional. 2. Unit may cause severe injures if you have doubts concerning the safety do not install. 3. Unit is to be 24inches away from flammable materials (decoration material) 4. Use high quality installation equipment to hang unit.. When rigging a unit it is very important that you follow common safety procedures. Rigging requires extensive experience including but not limited to calculating working loads, material being used and periodic safety inspections. If you lack these qualifications, do not attempt the installation yourself, instead use a professional structural rigger. 2. When rigging the unit always be secured with a secondary safety attachment. The installation location of the projector has got to be built in the way that it can hold 0 times the weight for hour with out any harming. Installation should be checked at least one time a year by a skilled person. Service The Linx LE modules are designed so if there is a failure you are able to easily remove. 2
Maintenance Installation Maintenance: The operator has to make sure that the unit is operating safely and has the installations and electronics checked by an expert every 2 years. The following points have to be considered during the inspection: ) All screws used for installing the device or part of the device have to be tightly connected and must not be corroded. 2) There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing). 3) The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed. 4) Make sure the fans are not blocked from air flow. 5) Make sure signal cables and LX-driver and LX-P2 are not placed near any magnetic interference. isconnect from mains before starting maintenance operation! Caution anger to life! We recommend a frequent cleaning of the device. Please use a moist, lint free cloth. Never use alcohol or solvents! ) The objective lens will require periodic cleaning on usage and environment. Environment with foggers will require more periodic cleaning as fog fluid tends to build up residues, reducing the light output. 2) The cooling-fans should be cleaned monthly. O NOT blow high pressure air into fans as incorrect rotation can damage the fans operation. Note: There is no serviceable parts inside the device except for the lamp and the fuse. Maintenance and service operations are to be carried out by authorized dealers. Replacing the power cable: If the power cable of this device becomes damaged, it has to be replaced by authorized dealers only In order to avoid hazards. Should you have further questions, please contact your dealer. Parts List EL-RIVER Linx river EL-P8 Linx Power Supply & river 8 EL-P6 Linx Power Supply & river 6 EL-R river Card EL-RC Receiving Card EL-RPS Linx river Power Supply EN-C-A-3 3 Foot ata Cable OU Connection EN-C-A-3 3 Foot ata Cable OU Connection EN-C-PW-5 5 Foot Power Cable Neutrik to OU EN-CPW-3 3 Foot Power Cable Neutrik to OU EL-MO EL-BUM EL-BUM2 EL-BUM4 EL-PS Links Replacement LE module Linx Unit Bumper Linx 2 Unit Bumper Linx 4 Unit Bumper Power Supply 3
Software Mega-Lite s Enigma Linx Software is a easy to use, and easy learning software. The software will allow you to make effect looks and to play back almost any type of format. System Requirements Operating System: Windows XP, Windows Vista Video Card: Video Card with VI output Memory: 52M CPU:Pentium 300Mhz Windows Media Player 4
Video Monitor Settings. Right click on your desktop screen scroll to Properties.2 On your setting window of your isplay Properties. Click on window 2..3 Your screen resolution for monitor 2 should be set to 024 by 768.4 Check to Extend my Windows desktop onto this monitor 5
Mega-Lite 578 Kenwick St San Antonio, TX 78238 Ph 20-684-2600 Fax 20-855-6279 www.mega-lite.com / info@mega-lite.com