LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Similar documents
LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

GV2ME. Main. Device short name. Device application

GV2P05. Main. Device short name. Device application

GV2ME. Main. Device short name. Device application

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

AS09..S 3-pole Contactors - Spring Terminals

A V 50Hz / V 60Hz

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Magnecraft Power Relays

Series CT7N Bimetallic Overload Relays

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Safety dialogue solutions

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Datasheet - SRB301LC 24VAC/DC

Type: DILM25 10(24V50HZ) Article No.:

Type: DILM12 10(24VDC) Article No.:

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

Minicontactorrelay,2NO/2NC,DCoperated

02/11/2015

Ordering details. Approval. Classification

16 A and 25 A power contactors with or without handle

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Datasheet - SRB-E-201ST

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Modular pulse operated latching relay 16 A

Data Sheet Definite Purpose Contactors Ex9CK Series

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Circuit-Breakers for Motor Protection Series 8523/8

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

AC1036. Definite Purpose Contactors

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Bulletin 190 IEC Modular Starter System

ALLEN BRADLEY TIMING RELAY

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Interface Relays and Optocouplers Product group picture

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

llen-bradley 194R-HM4-NFPA3

Kuhnke Technical Data. Contact Details

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Series CDP2 Definite Purpose Contactors

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Series CDP2 Definite Purpose Contactors

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Pluggable interface relays CR-M Miniature relays

Panel-mounting thermostats, type series EM

Manual Motor Starter Specifcations

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

Data Pattern Generator

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Magnetic and Hydraulic-Magnetic Circuit Breaker

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Bulletin 100-G IEC Contactors

LED control gear Compact fixed output

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

DMX and 4000 air circuit breakers from 800 to 4000 A

POWER FACTOR CORRECTION

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

TeSys circuit-breakers

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

LED Driver Compact dimming

Transcription:

Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 120 V AC coil Product availability: Stock - Normally stocked in distribution facility Jun 19, 2014 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. *Prices are indicative

Price*: 696.00 USD Main Commercial Status Range of product Product or component type Device short name Contactor application Utilisation category Poles description Pole contact composition [Ue] rated operational voltage [Ie] rated operational current Motor power kw Motor power hp Control circuit type Control circuit voltage Auxiliary contact composition [Uimp] rated impulse withstand voltage Overvoltage category [Ith] conventional free air thermal current Irms rated making capacity Rated breaking capacity [Icw] rated short-time withstand current Associated fuse rating Average impedance Commercialised TeSys D Contactor LC1D Motor control Resistive load AC-1 AC-3 3P 3 NO <= 300 V DC for power circuit <= 1000 V AC 25...400 Hz for power circuit 150 A (<= 140 F (60 C)) at <= 440 V AC AC-3 for power circuit 200 A (<= 140 F (60 C)) at <= 440 V AC AC-1 for power circuit 75 kw at 1000 V AC 50/60 Hz 100 kw at 660...690 V AC 50/60 Hz 90 kw at 500 V AC 50/60 Hz 80 kw at 415...440 V AC 50/60 Hz 75 kw at 380...400 V AC 50/60 Hz 40 kw at 220...230 V AC 50/60 Hz 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors AC 50/60 Hz 120 V AC 50/60 Hz 1 NO + 1 NC 8 kv conforming to IEC 60947 III 200 A at <= 140 F (60 C) for power circuit 1660 A at 440 V for power circuit conforming to IEC 60947 250 A DC for signalling circuit conforming to IEC 140 A AC for signalling circuit conforming to IEC 1400 A at 440 V for power circuit conforming to IEC 60947 1400 A <= 104 F (40 C) 1 s power circuit 1200 A <= 104 F (40 C) 10 s power circuit 580 A <= 104 F (40 C) 1 min power circuit 140 A 100 ms signalling circuit 120 A 500 ms signalling circuit 100 A 1 s signalling circuit 250 A <= 104 F (40 C) 10 min power circuit 250 A gg at <= 690 V coordination type 2 for power circuit 315 A gg at <= 690 V coordination type 1 for power circuit 10 A gg for signalling circuit conforming to IEC 0.6 mohm at 50 Hz - Ith 200 A for power circuit 2

[Ui] rated insulation voltage Electrical durability Power dissipation per pole Protective cover Mounting support 1000 V for power circuit conforming to IEC 60947-4-1 600 V for signalling circuit certifications UL 600 V for signalling circuit certifications CSA 690 V for signalling circuit conforming to IEC 60947-1 600 V for power circuit certifications UL 600 V for power circuit certifications CSA 1 Mcycles 200 A AC-1 at Ue <= 440 V 0.85 Mcycles 150 A AC-3 at Ue <= 440 V AC-3 AC-1 With Plate Rail Standards EN 60947-4-1 EN IEC 60947-4-1 IEC UL 508 CSA C22.2 No 14 Product certifications BV CCC CSA DNV GL GOST RINA UL LROS Connections - terminals Power circuit: connector 2 cable(s) 0.02...0.08 in² (10...50 mm²) - cable stiffness: solid - without cable end (10...120 mm²) - cable stiffness: solid - without cable end Power circuit: connector 2 cable(s) 0.02...0.08 in² (10...50 mm²) - cable stiffness: flexible - with cable end (10...120 mm²) - cable stiffness: flexible - with cable end Power circuit: connector 2 cable(s) 0.02...0.08 in² (10...50 mm²) - cable stiffness: flexible - without cable end (10...120 mm²) - cable stiffness: flexible - without cable end (1...2.5 mm²) - cable stiffness: solid - without cable end (1...2.5 mm²) - cable stiffness: solid - without cable end (1...2.5 mm²) - cable stiffness: flexible - without cable end (1...2.5 mm²) - cable stiffness: flexible - without cable end (1...2.5 mm²) - cable stiffness: flexible - with cable end (1...2.5 mm²) - cable stiffness: flexible - with cable end Tightening torque Operating time Safety reliability level Mechanical durability Operating rate Power circuit: 106.19 lbf.in (12 N.m) - on connector hexagonal 0.16 in (4 mm) Control circuit: 10.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 10.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm 40...75 ms opening 20...35 ms closing B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 8 Mcycles 1200 cyc/h at <= 140 F (60 C) 3

Complementary Coil technology Control circuit voltage limits Inrush power in VA Hold-in power consumption in VA Heat dissipation Built-in bidirectional peak limiting diode suppressor 0.8...1.15 Uc at 131 F (55 C) operational 50/60 Hz 0.3...0.5 Uc at 131 F (55 C) drop-out 50/60 Hz 280...350 VA at 20 C (cos? 0.9) 50 Hz 280...350 VA at 20 C (cos? 0.9) 60 Hz 2...18 VA at 20 C (cos? 0.9) 50 Hz 2...18 VA at 20 C (cos? 0.9) 60 Hz 3...4.5 W at 50/60 Hz Auxiliary contacts type Type mirror contact (1 NC) conforming to IEC 60947-4-1 Type mechanically linked (1 NO + 1 NC) conforming to IEC Signalling circuit frequency Minimum switching current Minimum switching voltage Non-overlap time Insulation resistance 25...400 Hz 5 ma for signalling circuit 17 V for signalling circuit 1.5 ms on energisation (between NC and NO contact) 1.5 ms on de-energisation (between NC and NO contact) > 10 MOhm for signalling circuit Environment IP degree of protection IP2x front face conforming to IEC 60529 Protective treatment TH conforming to IEC 60068-2-30 Pollution degree 3 Ambient air temperature for operation Ambient air temperature for storage Permissible ambient air temperature around the device Operating altitude 23...140 F (-5...60 C) -76...176 F (-60...80 C) -40...158 F (-40...70 C) at Uc 9842.52 ft (3000 m) without derating in temperature Fire resistance 1562 F (850 C) conforming to IEC 60695-2-1 Flame retardance V1 conforming to UL 94 Mechanical robustness Height Width Depth Product weight Shocks contactor open 6 Gn for 11 ms Shocks contactor closed 15 Gn for 11 ms Vibrations contactor closed 4 Gn, 5...300 Hz Vibrations contactor open 2 Gn, 5...300 Hz 6.22 in (158 mm) 4.72 in (120 mm) 5.35 in (136 mm) 5.51 lb(us) (2.5 kg) Ordering and shipping details Category 22345 - CTR,D-LINE,OPEN,NONREV-NEW Discount Schedule I12 GTIN 00785901214519 Nbr. of units in pkg. 1 Package weight(lbs) 5.48 Product availability Stock - Normally stocked in distribution facility Returnability Y Country of origin CZ 4

Offer Sustainability Sustainable offer status Green Premium product RoHS Compliant - since 0932 - Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Product environmental profile Available Download Product Environmental Product end of life instructions Need no specific recycling operations Contractual warranty Period 18 months 5