Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Similar documents
Minicontactorrelay,2NO/2NC,DCoperated

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Type: DILM25 10(24V50HZ) Article No.:

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Type: DILM12 10(24VDC) Article No.:

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

AS09..S 3-pole Contactors - Spring Terminals

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Series CT7N Bimetallic Overload Relays

Datasheet - SRB301LC 24VAC/DC

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Bulletin 190 IEC Modular Starter System

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

02/11/2015

A V 50Hz / V 60Hz

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Datasheet - SRB-E-201ST

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Ordering details. Approval. Classification

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

Magnecraft Power Relays

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

ALLEN BRADLEY TIMING RELAY

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

AC1036. Definite Purpose Contactors

Data Sheet Definite Purpose Contactors Ex9CK Series

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Pluggable interface relays CR-M Miniature relays

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Modular pulse operated latching relay 16 A

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV2ME. Main. Device short name. Device application

Manual Motor Starter Specifcations

Type Contact form Model

Product Data Sheet 8506 VW-691

8 Installation Equipment

LED Driver Compact fixed output

llen-bradley 194R-HM4-NFPA3

Bulletin 100-G IEC Contactors

Circuit-Breakers for Motor Protection Series 8523/8

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Series CDP2 Definite Purpose Contactors

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Interface Relays and Optocouplers Product group picture

Generator protection relay

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

GV2ME. Main. Device short name. Device application

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Magnetic and Hydraulic-Magnetic Circuit Breaker

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

.1 Product Overview The XT line of IEC power control offers starting and protection solutions ideal for control panels. Innovations in the design and

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

Series CDP2 Definite Purpose Contactors

LED Driver Compact fixed output

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

LED Driver Compact dimming

LED MODULES READYLINE DL

High performance circuit breakers

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

Product Data Sheet 4656 ZW

Process Transmitter RMA 422

Kuhnke Technical Data. Contact Details

Transcription:

Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with interlocked opposing contacts Connection technique Screw terminals Ratedoperationalcurrent Conventional free air thermal current, 3 pole, 50-60 Hz AC-15 Open Contacts at 50 C I th =I e A 10 220 V 230 V 240 V I e A 6 380 V 400 V 415 V I e A 3 N/O = Normally open 3 N/O N/C = Normally closed 1 NC Contact sequence Codenumberandversionofcombination Distinctive number 31E For use with DILE Actuating voltage 230 V 50 Hz, 240 V 60 Hz Voltage AC/DC AC operation Instructions Contact numbers to EN 50011 Coil terminal markings to EN 50005 Technicaldata General Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated Operations x 10 6 10 Maximum operating frequency Operations/h 9000 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open C -25 - +50 Enclosed C - 25-40 Mounting position Mounting position As required, except vertical with terminals A1/A2 at the bottom Mounting position 02/25/2016 051768 - HPL-ED2016 V19.0 EN 1 / 7

Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock, 10 ms Basic unit with auxiliary contact module g N/O contact g 10 N/C contact g 8 Degree of Protection IP20 Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Weight AC operated kg 0.17 Terminal capacities mm 2 Screw terminals Solid 2 mm 1 x (0.75-2.5) 2 x (0.75-2.5) Flexible with ferrule 2 mm 1 x (0.75-1.5) 2 x (0.75-1.5) Solid or stranded AWG 18-14 Terminal screw M3.5 Pozidriv screwdriver Size 2 Standard screwdriver mm 0.8 x 5.5 1 x 6 Max. tightening torque Nm 1.2 Contacts Positive operating contacts to EN 60947-5-1 appendix L, including auxiliary contact module Rated impulse withstand voltage U imp V AC 6000 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V AC 690 Rated operational voltage U e V AC 600 Safe isolation to EN 61140 between coil and auxiliary contacts V AC 300 between the auxiliary contacts V AC 300 Rated operational current A Conventional free air thermal current, 3 pole, 50-60 Hz AC-15 Open at 50 C I th =I e A 10 220 V 230 V 240 V I e A 6 380 V 400 V 415 V I e A 3 500 V I e A 1.5 DC current Notes Switch-on and switch-off conditions based on DC-13, time constant as specified. DC-13 L/R - 15 ms Contacts in series: A 1 24 V A 2.5 2 60 V A 2.5 3 110 V A 1.5 3 220 V A 0.5 Control circuit reliability Failure rate λ <10-8, < one failure at 100 million operations (at U e = 24 V DC, U min = 17 V, I min = 5.4 ma) Short-circuit rating without welding Maximum overcurrent protective device 220 V 230 V 240 V PKZM0 4 380 V 400 V 415 V PKZM0 4 Short-circuit protection maximum fuse 500 V A gg/gl 6 500 V A fast 10 Yes 02/25/2016 051768 - HPL-ED2016 V19.0 EN 2 / 7

Current heat loss at I th AC operated W 0.2 Magnetsystems Voltage tolerance AC operated Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Pick-up x U c 0.8-1.1 Dual-frequency coil 50/60 Hz Pick-up x U c 0.85-1.1 Power consumption AC operation Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Pick-up VA 25 Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Sealing VA 4.6 Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Sealing W 1.3 Dual-frequency coil 50/60 Hz at 50 Hz Pick-up VA 25 Dual-frequency coil 50/60 Hz at 50 Hz Sealing VA 4.6 Dual-frequency coil 50/60 Hz at 50 Hz Sealing W 1.3 Dual-frequency coil 50/60 Hz at 60 Hz Pick-up VA 30 29 Dual-frequency coil 50/60 Hz at 60 Hz Sealing VA 5.4 3.9 Dual-frequency coil 50/60 Hz at 60 Hz Sealing W 1.6 1.1 duty factor % DF 100 Switching times at 100 % U c (approximate values) AC operated closing delay ms 14-21 AC operated N/O contact opening delay ms 8-18 AC operated With auxiliary contact module Max. closing delay ms 45 DesignverificationasperIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 6 Heat dissipation per pole, current-dependent P vid W 0.4 Equipment heat dissipation, current-dependent P vid W 0 Static heat dissipation, non-current-dependent P vs W 1.8 Heat dissipation capacity P diss W 0 Operating ambient temperature min. C -25 Operating ambient temperature max. C 50 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 02/25/2016 051768 - HPL-ED2016 V19.0 EN 3 / 7

10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TechnicaldataETIM6.0 Low-voltage industrial components (EG000017) / Contactor relay (EC000196) Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Contactor relay (ecl@ss8.1-27-37-10-01 [AAB716011]) Rated control supply voltage Us at AC 50HZ V 230-230 Rated control supply voltage Us at AC 60HZ V 240-240 Rated control supply voltage Us at DC V 0-0 Voltage type for actuating AC Rated operation current Ie, 400 V A 3 Connection type auxiliary circuit Screw connection Mounting method DIN-rail/screw Interface No Number of auxiliary contacts as normally closed contact 1 Number of auxiliary contacts as normally open contact 3 Number of auxiliary contacts as normally closed contact, delayed switching 0 Number of auxiliary contacts as normally open contact, leading 0 With LED indication No Number of auxiliary contacts as change-over contact 0 Manual operation possible No Approvals Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 012528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Specially designed for North America No 02/25/2016 051768 - HPL-ED2016 V19.0 EN 4 / 7

Characteristics 1: Suppressor 2: Auxiliary contact module 02/25/2016 051768 - HPL-ED2016 V19.0 EN 5 / 7

Component lifespan (operations) Ie = Rated operational current Dimensions DILER- DILER- -G(-C) 02/25/2016 051768 - HPL-ED2016 V19.0 EN 6 / 7

DILER- (-C) + DILE(-C) DILER- -G(-C) + DILE(-C) 2DILE- + MVDILE + DILE 2DILE- -G + MVDILE + DILE Additionalproductinformation(links) IL03407009Z(AWA2100-0882)Minicontactorrelay IL03407009Z (AWA2100-0882) Mini contactor relay UL/CSA: Approved rating data ftp://ftp.moeller.net/documentation/awa_instructions/il03407009z2010_10.pdf http://de.ecat.moeller.net/flip-cat/?edition=hplte&startpage=5.84 02/25/2016 Eaton Industries GmbH http://www.eaton.eu 02/2016 by Eaton Industries GmbH 051768 - HPL-ED2016 V19.0 EN 7 / 7