Linear flow controls VFC Linear flow controls with actuator IFC

Similar documents
Linear flow control with actuator IFC

Actuators IC 20, IC 40

Actuators IC 20, IC 30, IC 50

SQM40/41 Actuators for air and gas dampers

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

820 NOVA 820 NOVA. 1 Control knob. 2 Pressure regulator cap screw 3 Pilot gas rate adjuster 4 Thermocouple connection

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

LED Driver Linear / area fixed output

Datasheet - SRB301LC 24VAC/DC

Level Measurement silometer FMC 420, FMC 423

Capacitance Limit Detection nivotester FTC 420/421/422

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

LED control gear Compact fixed output

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Single Point Flow Monitor SW118 SW119

LED Driver Compact dimming

Modular Lube Lubrication Systems System Controls

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

02/11/2015

Part-Turn Electric Multi-Turn Electric

Process transmitter RMA422

Ordering details. Approval. Classification

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Kuhnke Technical Data. Contact Details

LAUREL ELECTRONICS, INC.

LED Driver Compact fixed output

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

LED Driver Compact fixed output

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Solenoid valves VZWD, directly actuated

Type: DILM25 10(24V50HZ) Article No.:

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Product Data Sheet 4656 ZW

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Type: DILM12 10(24VDC) Article No.:

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Sensor technologies Proximity sensors Series ST4. Brochure

Product Data Sheet 4656 EZ

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Datasheet - SRB-E-201ST

RKSlimlift / EM. Two-stage lifting column

MICROMASTER Encoder Module

Minicontactorrelay,2NO/2NC,DCoperated

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Lt DELTA USA, Inc

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Pendant Light Fitting IEC Series 6470/2

LED Driver Compact fixed output

PROPORTIONAL VALVES Sentronic plus

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

Mechanical flow switch for On/Off control

7 Lighting Technology

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Operating instructions

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Product Data Sheet 8506 VW-691

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

GRUNDFOS alldos product information. The solution for complex dosing tasks

Solenoid valves VZWD, directly actuated

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

4-in-1 Motor Controller CAN

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Model Number Structure

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Process Transmitter RMA 422

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Photoelectrics Through-beam Type PA18C.T..., DC

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Pluggable interface relays CR-M Miniature relays

DATA SHEET Panorama Rudder Indicator, TRI-2

Inductive sensor NI3-EG08K-Y1-H1341

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

DMP 331i / DMP 333i LMP 331 i

Inductive sensor BI1.5-EG08K-Y1

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Electric Rotary Modules. Rotary Actuators

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

Revision 1.0 Parts List Minor

Transcription:

Linear flow controls VFC Linear flow controls with actuator Product brochure GB 3 Edition 01.16 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 Actuators IC 20 or IC 40 mounted directly Actuator IC 30 (24 V DC) can be mounted For gas and air Low leakage rates High control accuracy EU certified

2 VFC, Edition 01.16 Application VFC VFC with IC 30 The is composed of linear flow control VFC and actuator IC 20 or IC 40. It is designed to adjust volumes of gas and cold air on various appliances. The is designed for control ratios up to 25:1 and is suitable for regulating flow rates for modulating or stage-controlled combustion processes. Actuator IC 20 is controlled by a modulating signal or three-point step signal. Actuator IC 40 offers additional functions. It can be adjusted using the BCSoft programming software via an optical interface. The control type (two-point signal, three-point step signal or continuous control), running times, angles of rotation and intermediate positions can thus be programmed. Actuator IC 30 (24 V DC) can also be combined with a VFC. VFC IC 20, IC 40

VFC, Edition 01.16 3 Examples of application Lambda control If the burner is to be operated with different lambda values for process reasons, the can be used to correct the lambda value. VAS VAG IC + BVA BVA Adjusting the burner capacity In pneumatic ratio control systems, the with actuator IC 20..E determines the air volume for the required burner capacity. The fine-adjusting valve VV is used to adjust the high-fire rate. VAS VAG 4 20 ma VV

4 VFC, Edition 01.16 Zone control After initiating the burner control unit, the gas solenoid valves open and the is set to ignition position. The burner is ignited by the burner control unit BCU. The gas flow rate can be adjusted continuously using the. The air flow rate remains constant. AKT AKT VAS EKO BIC..L EKO LEH BCU Excess air burner After initiating the burner control unit, the moves to the ignition position. The burner is ignited by the burner control unit BCU. The gas flow rate can be adjusted continuously using the. The air flow rate remains constant. AKT VAS EKO PBG BCU BVA

VFC, Edition 01.16 5, VFC type code Code Description VFC Linear fl ow control Linear fl ow control with actuator 1 Size 1 3 Size 3 T T-product 10, 15, 20, 25, 40, 50, 65 Inlet fl ange nominal size - No inlet fl ange /10, /15, /20, /25, /40, Outlet fl ange nominal size /50, /65 /- No outlet fl ange R Rp internal thread N NPT internal thread F ISO fl ange 05 p u max. 500 mbar -08-15 -20 Cylinder -25-32 -40 P 1 2 3 4 - P 1 2 3 4 - Accessories, right, inlet Plug Pressure test point Pressure switch for gas DG 17VC Pressure switch for gas DG 40VC Pressure switch for gas DG 110VC Pressure switch for gas DG 300VC No accessories Accessories, right, outlet Plug Pressure test point Pressure switch for gas DG 17VC Pressure switch for gas DG 40VC Pressure switch for gas DG 110VC Pressure switch for gas DG 300VC No accessories Code Description The same accessories can be selected for the left- or right-hand side. /20 Actuator IC 20 /40 Actuator IC 40 Running time [s]/90 : -07 7.5-15 15-30 30-60 60 W Q A 2 3 T E D A R10 no specifi cation -I ains voltage: 230 V AC, 50/60 Hz 120 V AC, 50/60 Hz 100 230 V AC, 50/60 Hz Torque: 2.5 Nm 3 Nm Three-point step control 0 (4) 20 ma, 0 10 V continuous control Digital input 4 20 ma analogue input 1000 Ohm feedback potentiometer ounting actuator with electrical connection: outlet side inlet side Flow rate p [mbar] 400 200 100 VFC 1.., 0 VFC 3..-25 / VFC 3..-32, 0 VFC 3..-40, 0 VFC 115..-08, 90 VFC 120..-15, 90 VFC 125..-20, 90 VFC 340..-25, 90 VFC 350..-32, 90 VFC 350..-40, 90 20 10 4 2 1 0,1 2 4 10 20 100 200 1000 Q n [m 3 /h]

6 VFC, Edition 01.16 Technical data VFC Gas types: natural gas, LPG (gaseous), biogas (max. 0.1 %-by-vol. H 2 S) or clean air; other types of gas on request. The gas must be dry in all temperature conditions and must not contain condensate. Control ratio: 25:1. Leakage rate: < 2% of k VS value. ax. inlet pressure p u max. : 500 mbar (7.25 psi). Connection flanges: Rp internal thread pursuant to ISO 7-1. Housing material: aluminium, control cylinder: aluminium, flow restricting cylinder: PO, seal: HNBR/NBR. Ambient temperature: -20 to +60 C (-4 to +140 F). Storage temperature: -20 to +40 C (-4 to +104 F). Installation position as required; in conjunction with IC in the vertical upright position or tilted up to the horizontal, not upside down. IC 20, IC 20..E Line entrance for electrical connection: 3 x 20 plastic cable glands. Screw terminals using the elevator principles for cables up to 4 mm 2 (single core cables) and for cables up to 2.5 mm 2 with wire end ferrules. Typical designed lifetime: Switching current Switching cycles cos ϕ = 1 cos ϕ = 0.3 1 ma 1,000,000 22 ma 1) 1,000,000 100 ma 1,000,000 2 A 100,000 1) Typical contactor application (230 V, 50/60 Hz, 22 ma, cos ϕ = 0.3) Three-point step signal to terminals 1 and 2: minimum pulse duration: 100 ms, minimum pause between 2 pulses: 100 ms. Enclosure: IP 65, safety class: I. Ambient temperature: -20 to +60 C (-4 to +140 F), no condensation permitted. Storage temperature: -20 to +40 C (-4 to +104 F). ains voltage: 120 V AC, -15/+10%, 50/60 Hz, 230 V AC, -15/+10%, 50/60 Hz. Running time [s/90 ] Torque [Nm] Type 50 Hz 60 Hz 50 Hz 60 Hz IC 20-07 7.5 6.25 2.5 2 IC 20-15 15 12.5 3 3 IC 20-30 30 25 3 3 IC 20-60 60 50 3 3 IC 20 Power consumption: 4.9 VA at 50 Hz, 5.8 VA at 60 Hz. Resistance of the feedback potentiometer: 1 kω, max. 1 W. IC 20..E Power consumption: terminals 1, 2 and 5: 4.9 VA at 50 Hz, 5.8 VA at 60 Hz, terminal 3: 8.4 VA at 50 Hz, 9.5 VA at 60 Hz, in total not exceeding: 8.4 VA at 50 Hz, 9.5 VA at 60 Hz. Position feedback output: 4 20 ma, electrically isolated, max. 500 Ω load impedance. The output is always active when supply voltage is applied to terminals 3 and 4. Input: electrically isolated, 0 (4) 20 ma: load impedance switchable between 50 Ω and 250 Ω, 0 10 V: 100 kω input resistance. IC 30 ains voltage: 24 V DC, ±20%. Line entrance: 3 x 16 plastic cable glands (enclosed). Screw terminals using the elevator principles for cables up to 2.5 mm 2 with wire end ferrules. The running time changes depending on the load. It refers to the torque, see type label. Contact rating of the cam switches: in. current Voltage (resistive load) ax. current (resistive load) 24 230 V, 50/60 Hz 1 ma 2 A 24 V DC 1 ma 100 ma Enclosure: IP 65. Duty cycle: 100%. Ambient temperature: -15 to +60 C (5 to 140 F), no condensation permitted. Storage temperature: -15 to +40 C (5 to 104 F). Resistance of the feedback potentiometer: 1 kω, < 50 V, recommended wiper current: 0.2 μa.

VFC, Edition 01.16 7 IC 40 ains voltage: 100 230 V AC, ±10%, 50/60 Hz, the actuator automatically adjusts to the respective mains voltage. Power consumption: 8.4 W, switch-on peak current: max. 8 A for max. 10 ms. Screw terminals using the elevator principles for cables up to 4 mm 2 (single core cables) and for cables up to 2.5 mm 2 with wire end ferrules. Angle of rotation: 0 90. Holding torque = torque as long as permanent supply voltage is applied. 2 digital inputs: 24 V DC or 100 230 V AC each. Current requirement of digital inputs: 3 ma ± 1.5 ma. 1 analogue input (optional): 4 20 ma (internal load impedance: max. 500 Ω at 20 ma). Potentiometer (optional): 1000 Ω +/- 20%, linearity tolerance +/- 2%, max. capacity 0.25 W, conductive plastic element. 2 digital outputs: Signalling contacts designed as relay change-over contacts. Contact current of digital outputs: min. 5 ma (resistive) and max. 2 A. The relay contacts can be connected to 100 230 V AC or 24 V DC. If the contacts have been connected with a voltage > 24 V and a current > 0.1 A once, the gold plating on the contacts will have been burnt through. This contact can then only be connected with this power rating or higher power rating. 2 LED status displays: Blue LED for operation ON ; actuator in motion = slow flashing light; manual operation = fast flashing light; actuator stopped = permanent light. Red LED for warnings and faults; warning = permanent light; fault = flashing light. Red and blue LED simultaneously, calibration in progress = flashing light. Enclosure: IP 65. Safety class: I. Line entrance for electrical connection: 3 x 20 plastic cable glands. Ambient temperature: -20 to +60 C (-4 to +140 F), no condensation permitted. Storage temperature: -20 to +40 C (-4 to +104 F). Running times and torques Type Running time [s/90 ] Torque [Nm] 50 Hz 60 Hz 50 Hz 60 Hz IC 40 4.5 76.5 4.5 76.5 2.5 2.5 On the IC 40, the running time and torque are independent of the mains frequency. The running time can be freely programmed between the limits of 4.5 and 76.5 s.

8 VFC, Edition 01.16 Detailed information on this product Contact www.kromschroeder.com Sales Elster GmbH Postfach 2809 49018 Osnabrück Strotheweg 1 49504 Lotte (Büren) Germany T +49 541 1214-0 F +49 541 1214-370 info@kromschroeder.com www.kromschroeder.com http://docuthek.kromschroeder.com/doclib/main.php?language=1&folderid=401140&by_class=6 We reserve the right to make technical modifications in the interests of progress. Copyright 2016 Elster GmbH All rights reserved. 03251371