RGA13, 12/10/17 Ultra High Resolution 20mm Quadrupole with Dual Zone operation

Similar documents
Quadrupoles have become the most widely used

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

How Quadrupole Size Affects Research

SC24 Magnetic Field Cancelling System

SC24 Magnetic Field Cancelling System

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

Perfecting the Package Bare and Overmolded Stacked Dies. Understanding Ultrasonic Technology for Advanced Package Inspection. A Sonix White Paper

Tutorial on Technical and Performance Benefits of AD719x Family

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

m RSC Chromatographie Integration Methods Second Edition CHROMATOGRAPHY MONOGRAPHS Norman Dyson Dyson Instruments Ltd., UK

2 MHz Lock-In Amplifier

Advanced Test Equipment Rentals ATEC (2832)

MODE FIELD DIAMETER AND EFFECTIVE AREA MEASUREMENT OF DISPERSION COMPENSATION OPTICAL DEVICES

Application Note: Using the Turner Designs Model 10-AU Fluorometer to Perform Flow Measurements in Sanitary Sewers by Dye Dilution

Non-Invasive Energy Spread Monitoring for the JLAB Experimental Program via Synchrotron Light Interferometers

FAST MOBILITY PARTICLE SIZER SPECTROMETER MODEL 3091

CHAPTER 3 SEPARATION OF CONDUCTED EMI

32 Channel Auto Searching Wireless FPV Monitor with Dual Receiver LCD Monitor. User Manual

XC-77 (EIA), XC-77CE (CCIR)

OPTICAL POWER METER WITH SMART DETECTOR HEAD

SUMMARY OF THE METHOD SAMPLE PREPARATION

Agilent 7000 Series Triple Quadrupole GC/MS System

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

Timing Modules. Connect Frequency Control Timing Modules

SMT Encoder for High Performance, High Volume Designs Small Size High Resolution Low Cost ChipEncoder Reflective Surface Mount Encoder Features

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

technical note flicker measurement display & lighting measurement

GC/LC-MS: data acquisition rate and peak reconstruction

LHC Beam Instrumentation Further Discussion

SC26 Magnetic Field Cancelling System

EMC-Scanner. HR-series

TABLE OF CONTENTS. Instructions:

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 65 MSPS DUAL ADC

vacuum analysis surface science plasma diagnostics gas analysis

Layout Analysis Analog Block

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

The PEFP 20-MeV Proton Linear Accelerator

EDDY CURRENT IMAGE PROCESSING FOR CRACK SIZE CHARACTERIZATION

Figure 2: components reduce board area by 57% over 0201 components, which themselves reduced board area by 66% over 0402 types (source Murata).

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

MAXIMUM PRODUCTIVITY DUE TO SHORTEST CONVERSION TIMES

Principles of Electrostatic Chucks 6 Rf Chuck Edge Design

Electro-Optic Beam Deflectors

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

Organic light emitting diode (OLED) displays

Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

Interface Practices Subcommittee SCTE STANDARD SCTE Composite Distortion Measurements (CSO & CTB)

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 3rd Edition

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

METROTOM. Visible Metrology.

Engineering Note. 1 Introduction Basics of Light Propagation in Multi-Mode Fiber... 2

I n d u s t r i a l M e t r o l o g y f r o m C a r l Z e i s s. METROTOM. Visible Metrology.

E X P E R I M E N T 1

DELTA MODULATION AND DPCM CODING OF COLOR SIGNALS

ZONE PLATE SIGNALS 525 Lines Standard M/NTSC

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

Fusion CD64 CD Player Digital Engine in Depth

Using the new psychoacoustic tonality analyses Tonality (Hearing Model) 1

New Filling Pattern for SLS-FEMTO

Electrospray-MS Charge Deconvolutions without Compromise an Enhanced Data Reconstruction Algorithm utilising Variable Peak Modelling

35058-TE. PLJ-6LED-A LED Frequency Display Module Manual

456 SOLID STATE ANALOGUE TAPE + A80 RECORDER MODELS

How smart dimming technologies can help to optimise visual impact and power consumption of new HDR TVs

HOT LINKS Trade Show Schedule ISO Certification Contact

Gas Analysis. Microvision 2 STABILITY, ACCURACY AND SPEED THE RGA YOUR PROCESS CAN RELY ON

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Signal Stability Analyser

Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

Experiment 13 Sampling and reconstruction

ELECTRICAL TESTING FOR:

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Spectrum Analyser Basics

Power Amplifier 0.5 W 2.4 GHz AM TR Features. Functional Schematic. Description. Pin Configuration 1. Ordering Information

Investigation of Radio Frequency Breakdown in Fusion Experiments

Investigation of Digital Signal Processing of High-speed DACs Signals for Settling Time Testing

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

HD RANGER Revolutionising the market. Again.

Universal High Current Implanter for Surface Modifications with ion beams Extensive range of ion species, including refractory metals Magnetic mass

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION

ThinkRF D GHz RF Downconverter

This work was supported by FINEP (Research and Projects Financing) under contract

EMC Test Report. Client: Continental Automotive Systems, Inc. Tested by: Fendy Liauw, Engineering Technician

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Full Disclosure Monitoring

Characterization and improvement of unpatterned wafer defect review on SEMs

User s Manual. Log Scale (/LG) GX10/GP10/GX20/GP20 IM 04L51B01-06EN. 1st Edition

Time Domain Simulations

Compressed Air Management Systems SIGMA AIR MANAGER Pressure flexibility Switching losses Control losses next.

Performance Evaluation of Proposed OFDM. What are important issues?

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

Precision testing methods of Event Timer A032-ET

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

TMT data acquisition on the LTQ-Orbitrap XL Mass Spectrometer

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

MAMX Sub-Harmonic Pumped Mixer GHz Rev. V1. Functional Schematic. Features. Description. Pin Configuration 1

Transcription:

RGA13, 12/10/17 Ultra High Resolution 20mm Quadrupole with Dual Zone operation

The DLS-20 Hiden s 20mm Triple Filter Quadrupole By comparison, 6mm Triple Filter Quadrupole

Quadrupole High resolution Quadrupoles are challenged by species with similar m/z For example, He and D 2 are separated by just 0.026u Separation requires a quadrupole with high resolving power

Factors contributing to high resolution Residence time of ions in the quadrupole field - e.g. ion energy Increased time yields greater rejection of unwanted m/z Field imperfections e.g. variation in rod diameter Reduce influence of mechanical tolerance by increasing rod diameter Number of RF cycles experienced by the ion e.g. frequency Resolution improves by square of number of cycles Pre and post filters 3F analysers Stability zone e.g. Zone I Optimise choice of stability zone to reduce peak tailing

Field Radius Filter scatter, degrades resolution Scatter, dm/m = 2 * dr 0 / r 0 Rod and yolk manufacturing tolerances contribute to dr 0 The larger the rod (& yolk) diameter, the lower the scatter. Conclusion - choose large, 20mm, rod size for high resolution rod r. r 0 yolk

Minimising Field imperfections High resolving power requires high mechanical precision to reduce scatter Hiden s investment - air gauge metrology Metrology data feedback to both yolk and rod suppliers is part of our ongoing performance management procedure Air gauge measurement as part of the quality control system enables precision in manufacture. Deviation of less than 1 µm (< 50 PPB) is confirmed along the entire quadrupole assembly length Hiden s Quadrupole air gauging tool

Maximise Frequency Frequency is a determinant of number of RF cycles But increase frequency raises [RF Power]^5 Hiden s High Power RF Generator provides >150W of electrical power to create High Frequency. Result DLS-20 Electronics maximises RF frequency - and RF Cycles

Resolution and Stability Regions Regions of stability for x and y motions in a quadrupole, defined by Mathieu equation parameters a and q. Transmission of an ion occurs when a and q values are within both stable x and stable y boundaries Quadrupoles are normally operated within Stability Zone I, but other zones exist Zone III gives opportunity to increase resolving power Hiden designation Zone H Zone H

Resolution and Stability Regions In electrical terms the stability regions can be defined by their RF:DC ratio and their Volts per amu, for any rod diameter and frequency. For the DLS-20, Zone I needs 14.6v of RF per u and a ratio 5.96 Zone H needs 66.7v of RF per u and a ratio 2.04 Quadrupoles are normally operated in Zone I Lowest volts per amu and good sensitivity make it suitable for all masses Zone H offers higher resolving power High voltage requirements confine its use to lower masses

signal Stability Zone I Arrange volts within red boundary to create stable paths through quadrupole yields He transmission (Log) The sum of the DC and RF volts shown in the graph is applied to the quadrupole rod pairs, with 180 o of phase shift Raise the scan line to increase resolution and achieve separation from D 2 gives D 2 rejection mass He Stability by Rod Voltage, Zone I

Stability Zone I Linear plot indicates separation Log plot reveals significant peak tailing, that is, incomplete rejection at adjacent mass The contribution of the D 2 tail (abundance sensitivity) imposes a limitation on the level of He detection Sensitivity at this resolution of > 2e-7A/Torr Lin Log

signal Stability Zone H Arrange volts within yellow boundary for He transmission LOG H Raise scan line to Upper Tip of boundary for least peak tailing Reduced Tailing yields improved rejection of D 2 He Stability by Rod Voltage, Zone 1 and H mass H

Stability Zone H Linear plot shows separation achieved Log plot reveals minimal peak tailing high D 2 rejection Lin The contribution of D 2 (abundance sensitivity) to He is <1ppm Detection limit of He in D 2 increased by four orders of magnitude Log Sensitivity of >1e-6A/Torr

Hiden software gives full control Hiden s software enables Zone I and H scans in the same event sequence. Zone H Zone H 1 Select Zone 2 Define instrument parameters (emission, etc) Set mass range Zone H Zone H Scan 1 Scan 2 He D2 H20 Zone I 3 Zone I Scan 3 He Ar++

DLS-20 in Fusion Research 3He and HD separated by 0.006u Deuterated species, 16, 17, 18 amu with 0.033 to 0.036u separations He He D2 4He and D2 separated by 0.026u Data collected at Fusion Research centre

DLS-20 - Zone I to 200amu LOG Zoom 25 to 35 amu LIN

DLS-20 - Summary Quadrupoles with high mechanical precision yield increased resolving power Quadrupoles operated in Zone H improve detection limits of species subject to interference from adjacent mass The DLS-20 dual zone offers the choice of Zone I or Zone H The DLS-20 dual zone offers significant performance advantages for Fusion Research