Department of Radiology

Similar documents
CARDIAC OT INSTURMENTS

Corrigendum-II. Up to 30 th October 2018 till 17:00 Hrs. 31 st October 2018 till 17:00 Hrs. 2 nd November 2018 till 14:00 Hrs.

Comed Medical Systems Co., Ltd. Office 707, Woolim Lion s Valley I, 311-3, Sangdaewon-dong, Seongnam-si, Gyeonggi-do, Korea Tel:

Ergonomic design packed with powerful performance MULTIMOBIL 5C. Answers for life.

Delivery, installation, commissioning and warranty of multi-channel Programmable High Voltage Supply System

INSTRUCTIONS TO BIDDERS

Intra-oral X-ray unit with high frequency DC generator. Product Data

E-Tender Form (E-Tender enquiry for Supply and Installation of X-ray Units of 300mA & 600 ma at GGS Medical College & Hospital, Faridkot.

BCA 9R. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode

BCA 9S. ELECTRICAL CHARACTERISTICS Voltage 230 Vac ±10% monophase standard 105 / 115 / 125 / 220 / 240 Vac ±10% monophase on request

X-ray Tube Housing Assembly H1076X H1076Y Print No.HA Release Date:

JEFFERSON COLLEGE. Image Intensification & Equipment

Page 1 of 6 PROCUREMENT PROCEDURE OF CPRI (NON WORKS) Revision No. : 03 Issue No : 2 Dt of Revision : Issue Dt. :

Tender Notification for the procurement of a Scanning Electron Microscope" at IISc (Last Date for submission of tenders: 3 rd October 2018)

Request for Proposals

High Frequency X-Ray Technology. Wide Screen Control with Touch-Technology

INSTRUCTIONS TO BIDDERS

Block No. 12, CGO Complex Lodhi Road, New Delhi Dated: TENDER NOTICE NO.12/SSC(NR)/2015

HIGH COURT OF BOMBAY AT GOA

ziehm imaging ... dedicated to clinical innovation Ziehm Vista. TECHNICAL SPECIFICATIONS Most Versatile C-arm.

Practix. Mobile Radiography. All a Bucky station needs plus mobility. Practix 400

Imaging solutions for any size patient and any size budget.

FDA MAMMOSCAN FULL FIELD DIGITAL MAMMOGRAPHY SYSTEM MAMMOGRAPHY

ALL INDIA INSTITUTE OF SPEECH AND HEARING, MYSURU E-PROCUREMENT NOTIFICATION FOR SUPPLY OF ENDOVISION SYSTEM

ENGINEERING PROJECTS (INDIA) LTD (A Government of India Enterprises) Short Tender Notice

6. Fax Tender or Tender without EMD and Tender Fee will be summarily rejected.

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

UArm. Series. Analog or Digital U-Arm System

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

SHOWLINE SL BEAM 100 LED LUMINAIRE SPECIFICATIONS.

AaN~. ~?4. f-~m1m{f OJ -,U- Q()I~ JtfJlD~ J'k(.)JJ (Designation) .~ ~. ~~ J?SE C GeNZALEs, M.D. JAN Director }& ~ ~ NOTICE OF AWARD

SUBJECT :- REVISED BID NOTICE FOR PROCUREMENT OF DIGITAL SURROUND SOUND PROCESSOR WITH SURROUND SOUND SYSTEM FOR 5.

Portable Otoacoustic Emission Screener [Under Buyback]

CARESTREAM DIRECTVIEW Elite CR System

SEAMLESS INTEGRATION MULTIPLE SOLUTIONS ONE PRODUCT ONE COMPANY

CARESTREAM DIRECTVIEW Elite CR System

Toronto Hydro - Electric System

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

Identification - electrical services

OFFICE OF THE PRINCIPAL & SECRETARY MORIDHAL COLLEGE P.O. MORIDHAL, DIST. DHEMAJI From :

COUNTY OF LOS ANGELES SPECIFICATIONS For SHERIFF'S DEPARTMENT

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

DirectView Elite CR System. Improve workflow, productivity, and patient throughput.

SPECIAL SPECIFICATION 2344 TMC Support Equipment

SmartCrystal Cinema Neo

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

SPECIFICATION NO NOTE

TENSIONED ELPRO CONCEPT Motorized projection screen for wall or ceiling installations

CARESTREAM VITA/VITA LE/VITA SE CR System Long Length Imaging User Guide

-Technical Specifications-

FLIR Daylight and Thermal Surveillance (P/T/Z) Multi-Sensor systems

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment

SPECIFICATION NO Model 207 Automatic GTAW Welding System

BRIGHT BRIGHTER BRIGHTEST ONE ILLUMINATOR DESIGN THREE LIGHT SOURCES. featuring the EvenVue Reflector System

Purchasing Department Finance Group INVITATION TO BID

Procurement of IC TESTER & TRAINER KITS, OSCILLOSCOPES, FG S, DECADE BOXES AND ANALOG METERS

NATIONAL FILM ARCHIVE OF INDIA MINISTRY OF INFORMATION AND BROADCASTING GOVT OF INDIA LAW COLLEGE ROAD, PUNE NOTICE INVITING TENDER

TOSHIBA Industrial Magnetron E3328

SmartCrystal Cinema Neo

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

Cosmos2 The Economical X-ray Solution with the Best Image Quality and High Reliability

Portable Filter Cart Type SPFC

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

BUREAU OF ENERGY EFFICIENCY

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

CAPTURE CAPTURE. VERSiON 1.2. Specialists in Medical. Digital Imaging Solutions

Coronis Uniti (MDMC-12133) 12MP diagnostic display system for PACS and breast imaging

SPECIAL SPECIFICATION 6713 Ethernet Video Decoder (MPEG-4)

Dental Line. High frequency intraoral x-ray unit. radiology ahead

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

(Raj Kumar Jha) Deputy Secretary, DACY

10.4" LCD Monitor with Aluminum Front Bezel YPM1040PHB

Equipment Quality Control for Digital Radiography February 22, Imaging Physics CancerCare Manitoba

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

High performance circuit breakers

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Rural Development Department Old secretariat, Patna. Sub: - Invitation for Quotations for Printing & Supply of Booklets and Pamphlets To

Series description: Wilo-Sub TWU 3 HS

No. MME/INS/153/ Date: 27 August 2018 NOTICE INVITING TENDER

HIGH COURT OF HIMACHAL PRADESH, SHIMLA

Department of Planning & Development (Directorate of Economics & Statistics) Government of Bihar

Australian/New Zealand Standard

Winmate Communication INC.

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

SMART CINEMAHORIZONTAL. User Guide VPSP Projector side. model. Notice SmartCrystal Cinema MUV V1R0

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

THE CABLE TRAY SYSTEM

LCD VALUE SERIES (32 inches)

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Transcription:

KASTURBA HEALTH SOCIETY'S MAHATMA GANDHI INSTITUTE OF MEDICAL SCIENCES, P.O. SEVAGRAM, WARDHA (DISTT.) MAHARASHTRA STATE - 442 102 Specifications for Instruments/Equipment Department of Radiology 1. Upgradation of 500mA X-Ray Machine into 800mA X-Ray Machine with IITV Technical Specifications: 1 Unit The supplier should upgrade the existing 500mA machine into 800mA machine with IITV as per following specifications. It should have 800mA, 150KV high frequency x-ray machine with floor to ceiling stand, rotating anode x-ray tubes (2 in numbers), floor to ceiling stand, all position motorized examination table and 9 image intensifier system. Sr. Specifications No. 1 X-RAY MACHINE: 800 ma, 150KVP, High frequency x-ray generator for radiography and fluoroscopy. 2 RATING: RADIOGRAPHY: 40 to 150 KVP. FLOUROSCOPY: 40 to 120 KVP 3 Frequency Of Generator : 40 KHz. 4 Output Power: Minimum 50 KW. ma Range : Radiography : upto 800 ma Fluoroscopy : upto 20 ma (Pulse) 5 mas Range : 1-200 mas 6 CONTROL : Control should have having following features : Machine ON/OFF switch Digital display of KV and mas. KV and mas increase and decrease switches. Ready and x-ray on switch with indicators Bucky selection switch. Stand by and exposure release switch. Self-diagnostic program with indicators for:- Earth fault error KV error, filament error Filament error Tube Head thermal overload. X-Ray ON indicator. Incoming voltage indicator. Compliance Yes/No Detail specifications 1

A two-step hand switch with dual action for exposure release with retractable cord is provided for taking images from a safer distance. Please specify additional special features, if any. 7 X-RAY TUBE : Two (2) Rotating anode Dual focus 32/77 KW rating. The X-Ray tubes should be thermally protected and have focal spots of 0.6mm and 1.2 mm. Please specify. Better configuration will be preferred. Anode Heat Storage Capacity Minimum 250KHU. Higher will be preferred. Please specify. 8 HV TANK: Compact heavy duty transformer comprising HV silicon rectifiers, HT transformer, filament transformer, federal bushings all immersed in high dielectric strength transformer oil with high voltage cables. 9 COLLIMATOR : One manual (geared) for over couch One motorized for under couch collimator is provided. 10 HV CABLE: Two Pairs of 8 meter high voltage cables with straight sleevings. 11 TUBE STAND: Floor to ceiling tube stand mounted on floor with ceiling rails for convenient movement. The tube stand should be 360 rotatable and should have a counter balanced tube head. The tube head should be ±180 rotatable. Standard locks should be provided for longitudinal, vertical and transverse movements. 11 TABLE: Motorised table having motorised bucky and spot film device (semi-automatic) capable of doing all routine spot filming (4 on 1, 2 on 1, 1 on 1) for use with 8 x 10, 10 x 12, 14 x 14 cassettes respectively. Grid size 15 x 15, 6:1 ratio, 103 lines per inch. Stray radiation lead rubber flaps, Motorized bucky consisting of bucky grid of size 17 ¼ x 18⅞, 8:1 rao, 85 lines/inch. The movement of table is from 90 degree vertical to minimum 12 degree Trendelenberg with automatic stop at horizontal. Please specify the range. Stainless steel cassette tray, hand grips, foot rest and foot step should be provided. Digital display of Fluro parameters on spot film device will be preferred. Please specify. The entire fluoro procedure should be recordable on hard disk and be reviewed frame by frame. Operating voltage: 440 V A.C, three phase. 12 POWER SUPPLY: 3 Phase, 440Volts AC 50Hz with line resistance: <0.4 Ohms. Line requirement regulation ±10% with proper independent earthing. IITV SYSTEM: 2

1 IMAGE INTENSIFIER : 9 I.I mounted directly on SFD with motorized up/down movement. Facility to remotely control fluoro KV and ma from spot film device will be preferred. 2 CAMERA: State of art high resolution compact CCD camera, minimum ½ size of standard make. Total pixels: 752(H) X 582(V). 3 MONITOR: High resolution two (2) medical grade TV monitors, 19 size (Flat panel) along with the trolley. DIGITAL IMAGE MEMORY SYSTEMS: Monitor for images. Permanent image storage capacity of approx. 50,000 images. Up to 75 temporary image storage for quick review. DVD writer to store images on CD/DVD for giving it to patients. Flicker free images. 32 bit image storage for resolution at 800 x 600.Higher resolution will be preferred. Please specify. Image sharpening (real-time or stored images). Image rotation. Image EMBOSS for three-dimensional relief presentation. Colorized images. Dynamic contrast control (Gray Level Stretch). Negative images (Gray Level Invert). Frames averaging for smoothing of images. (Real time) up to 256 frames. Tile view (multiple images on the screen up to 8 x 8). Cine loop of atleast 500 frames (Multiple cine loops should be stored permanently). Variable frame rate of 2, 5, 10, 15 & 27 frames per second for cine loop. Image orientation: Left/ Right Top/ Bottom. Patient s Name, operator name, hospital name, date and time display on monitor. Images should be stored in folders of individual patient s name. Quick exploration of stored images. ON screen help mode. ON screen measurements Length (X and Y) and Area. Area of interest marker. Contrast enhancement of area of interest. Histogram of area of interest. Facility for image printing. Text annotations and provision of removal of all text from the image. Automatic capture and storage of cine loop with cine foot switch Offset and gain adjustments for improved image quality. Thumb nail use of complete study Frame by frame review. Printing options in different formats (frames of different loops can be printed on the same sheet, 1x1, 1x2, 1x4,1 x 6 3

and 1x8 formats) LAN connectivity. Digital zoom Panning Flip DICOM Compatible. System should be compatible and transferable with existing HIS and PACS system of institute. Processing unit should be branded. Best configuration will be preferred. AERB AERB approval is a must. All the approval and licensing formalities to be completed by the company after installation. Regular radiation monitoring as per AERB norms should be done by the company and should be included in the AMC/CMC. Cabling if required should be provided by the company. Warranty/CMC : Warranty will start after successful and complete installation of unit. CMC includes, machine, X-Ray tube, accessories, electrical fixtures, and all items supplied for next 8 years. All software upgrades should be provided free of cost for 7 years after installation. The supplier should provide the service for minimum 7 years after installation. The AMC and CMC rates must be quoted for a minimum of 7 years Important Note about existing machine to be upgraded: The existing radiography machine to be upgraded is Allengers 525/FC/ALLPOSE/DT machine and is in working condition. Interested parties can obtain the further details from the Department of Radiodiagnosis, MGIMS, Sevagram about the same before quoting the price bid if needed. 4

Check List (to be submitted with Technical Bid) The Vendor should submit following documents (duly attested) with Technical Bid (Please give Annexure No. for submitted Documents as mentioned below) Name of Company: Sr. No. Name of the Document Documents Submitted (Yes / No) Annexure No. Reason (for non submitted documents) 1. FDA / BIS Approval I 2. CE Certification II 3. ISO Certification (ISO 9001 & ISO 13485) III 4. VAT Registration & CST Registration IV 5. Manufacturing Certificate of Manufacturer Company V 6. Authorized Distributor Certificate (Current Year's) VI 7. Last 3 years Tax Assessment & Turn Over Certificates VII 8. User List (wherever Equipments / Instruments supplied & installed) VIII 9. PAN Card IX 10. Contact Person Name with Mobile No. X Signature with Company Seal 5

Kasturba Health Society's Mahatma Gandhi Institute of Medical Sciences Sevagram, Wardha (Dist), Maharashtra - 442 102 Terms and Conditions for the tenders Any non compliance of the following will amount to disqualification of the tender 1. Sealed tender should be addressed to the DEAN, Mahatma Gandhi Institute of Medical Sciences, Sevagram, (P.O.) Wardha (Dist), Maharashtra - 442 102 2. Tender should be submitted on or before 20/02/2017 up to 3.00 P.M. Tender received after the last date will not be accepted. Separate tenders are to be submitted for each instrument. Mention on the envelope "Tender for. (instrument name) of the Dept...(Dept name)". 3. Tender should be in two separate envelopes one for Technical Bid and other for Price Bid 4. The technical bid must contain the following (duly attested) along with Check List: a) Detailed technical specifications of equipment quoted (Catalogue / illustrated literature) and options / other model. b) A soft copy (CD) in Microsoft Word / Excel Format showing compliance with our given Technical Specifications (i.e. Compliance chart). c) Authorized dealer certificate (Current year's) from the Principal of manufacturing company for supply and service d) List of users / institutional installations / Govt. supply orders / Reputed private hospitals and copy of Manufacturing License from the manufacturer. e) Income Tax and annual returns of Last three years f) FDA Approval Certificate for the equipment / item & FDA Registration of the manufacturer. g) VAT & CST Registration Certificate h) PAN Card copy i) Country of Origin of the equipment j) If you are registered firm under Micro, Small Enterprises (MSEs), please submit a copy of the Registration Certificate. 6. For equipment to be imported the prices should to be quoted in both a) Foreign Currency - CIF Mumbai and also b) INR Delivery at Sevagram including all taxes and levies 6

Note: a) FOR CIF prices, the duty, transportation from Mumbai port to Sevagram, insurance will be borne by the buyer. b) FOR INR prices-- no excise duty, sales tax, VAT, transportation, insurance will be paid by the buyer. c) MGIMS is holding a DSIR Certificate for Custom Duty concession and excise duty exemption. d) For ease of computation you may furnish the import duty structure of your equipment and classification HSN code no of custom tariff. Import License and IEC code should also be submitted. e) Kindly quote the prices strictly as per the scope of the supply written in the tender without offering your special features and accessories prices. f) You have to provide Performance Bank Guarantee covering the Warranty period g) Penalty clause for delay in supplying will be applicable. 7. Payment terms: a) For CIF: L/C will be opened by the buyer on the condition of payment on successful installation of the equipment. b) For INR quote: Payment will be against successful installation of the equipment c) No advances are given with Purchase Order (PO). 8. Delivery period from date of Purchase Order (PO) to be written clearly in days. Penalty clause can be levied on case to case basis. Installation of the equipment should be free and to the satisfaction of the buyer. 9. Service and Guarantee conditions: a) Equipment will be under guarantee of two years from the date of installation. On case to case basis Performance Bank Guarantee may be sought. b) Mention the charges and terms of AMC & CMC (Labour + Part) applicable from 3rd year onwards. c) Mention about the nearest facility/office where service personnel are available. d) Mention about the facility for training of personnel safety and quality standards. 10. Dean M.G.I.M.S. reserves the right to reject all or any tender without assigning any reason. ***** 7