LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Similar documents
LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

GV2ME. Main. Device short name. Device application

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2P05. Main. Device short name. Device application

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV2ME. Main. Device short name. Device application

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

A V 50Hz / V 60Hz

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

AS09..S 3-pole Contactors - Spring Terminals

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

Magnecraft Power Relays

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Series CT7N Bimetallic Overload Relays

Datasheet - SRB301LC 24VAC/DC

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Type: DILM25 10(24V50HZ) Article No.:

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Type: DILM12 10(24VDC) Article No.:

Safety dialogue solutions

Minicontactorrelay,2NO/2NC,DCoperated

02/11/2015

Ordering details. Approval. Classification

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Datasheet - SRB-E-201ST

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

16 A and 25 A power contactors with or without handle

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

AC1036. Definite Purpose Contactors

Modular pulse operated latching relay 16 A

Bulletin 190 IEC Modular Starter System

Circuit-Breakers for Motor Protection Series 8523/8

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Data Sheet Definite Purpose Contactors Ex9CK Series

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Interface Relays and Optocouplers Product group picture

ALLEN BRADLEY TIMING RELAY

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Panel-mounting thermostats, type series EM

Kuhnke Technical Data. Contact Details

Series CDP2 Definite Purpose Contactors

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Series CDP2 Definite Purpose Contactors

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Manual Motor Starter Specifcations

TeSys circuit-breakers

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Pluggable interface relays CR-M Miniature relays

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

llen-bradley 194R-HM4-NFPA3

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

Bulletin 100-G IEC Contactors

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Data Pattern Generator

LED control gear Compact fixed output

Magnetic and Hydraulic-Magnetic Circuit Breaker

Definite Purpose Contactors

Panel-Mounted Thermostat

TRISHALA ELECTROLYTICS PVT LTD BANGALORE

Bulletin 100-G IEC Contactors

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Connecting cables NEBS, for sensors

Transcription:

Product data sheet Characteristics LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil Product availability : Stock - Normally stocked in distribution facility Price* : 696.00 USD Main Range Product name Product or component type Device short name Contactor application Utilisation category Poles description Power pole contact composition System Voltage [Ie] rated operational current Motor power kw Motor power HP (UL / CSA) Control circuit type [Uc] control circuit voltage Auxiliary contact composition TeSys TeSys D Contactor LC1D Motor control Resistive load AC-1 AC-3 AC-4 3P 3 NO <= 300 V DC power circuit <= 1000 V AC 25...400 Hz power circuit 200 A (<= 140 F (60 C)) at <= 440 V AC AC-1 power circuit 150 A (<= 140 F (60 C)) at <= 440 V AC AC-3 power circuit 40 kw at 220...230 V AC 50/60 Hz AC-3 75 kw at 380...400 V AC 50/60 Hz AC-3 80 kw at 415...440 V AC 50/60 Hz AC-3 90 kw at 500 V AC 50/60 Hz AC-3 100 kw at 660...690 V AC 50/60 Hz AC-3 75 kw at 1000 V AC 50/60 Hz AC-3 22 kw at 400 V AC 50/60 Hz AC-4 40 hp at 200/208 V AC 50/60 Hz 3 phases motors 50 hp at 230/240 V AC 50/60 Hz 3 phases motors 100 hp at 460/480 V AC 50/60 Hz 3 phases motors 125 hp at 575/600 V AC 50/60 Hz 3 phases motors AC 50/60 Hz 24 V AC 50/60 Hz 1 NO + 1 NC [Uimp] rated impulse withstand voltage Conforming to IEC 60947 Mar 17, 2019 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Overvoltage category [Ith] conventional free air thermal current III 200 A at <= 140 F (60 C) power circuit Irms rated making capacity 1660 A at 440 V power circuit conforming to IEC 60947 140 A AC signalling circuit conforming to IEC 60947-5-1 250 A DC signalling circuit conforming to IEC 60947-5-1 Rated breaking capacity 1400 A at 440 V power circuit conforming to IEC 60947 [Icw] rated short-time withstand current Associated fuse rating Average impedance 100 A 1 s signalling circuit 120 A 500 ms signalling circuit 140 A 100 ms signalling circuit 250 A <= 104 F (40 C) 10 min power circuit 580 A <= 104 F (40 C) 1 min power circuit 1200 A <= 104 F (40 C) 10 s power circuit 1400 A <= 104 F (40 C) 1 s power circuit 250 A gg at <= 690 V coordination type 2 power circuit 315 A gg at <= 690 V coordination type 1 power circuit 10 A gg signalling circuit conforming to IEC 60947-5-1 0.6 mohm at 50 Hz - Ith 200 A power circuit [Ui] rated insulation voltage 1000 V power circuit conforming to IEC 60947-4-1 600 V power circuit certifications CSA 600 V power circuit certifications UL 690 V signalling circuit conforming to IEC 60947-1 600 V signalling circuit certifications CSA 600 V signalling circuit certifications UL Electrical durability Power dissipation per pole Safety cover Mounting support 0.85 Mcycles 150 A AC-3 at Ue <= 440 V 1 Mcycles 200 A AC-1 at Ue <= 440 V 24 W AC-1 13.5 W AC-3 With Plate Rail Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 Product certifications BV CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UL Connections - terminals Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - without Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: solid - without Control circuit: screw clamp terminals 1 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with Control circuit: screw clamp terminals 1 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - without Control circuit: screw clamp terminals 1 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: solid - without Power circuit: connector 1 cable(s) 0.02...0.19 in² (10...120 mm²) - cable stiffness: flexible - without Power circuit: connector 2 cable(s) 0.02...0.08 in² (10...50 mm²) - cable stiffness: flexible - without Power circuit: connector 1 cable(s) 0.02...0.19 in² (10...120 mm²) - cable stiffness: flexible - with cable end Power circuit: connector 2 cable(s) 0.02...0.08 in² (10...50 mm²) - cable stiffness: flexible - with cable end Power circuit: connector 1 cable(s) 0.02...0.19 in² (10...120 mm²) - cable stiffness: solid - without 2

Tightening torque Operating time Power circuit: connector 2 cable(s) 0.02...0.08 in² (10...50 mm²) - cable stiffness: solid - without cable end Control circuit: 10.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 10.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 106.19 lbf.in (12 N.m) - on connector hexagonal 0.16 in (4 mm) 20...35 ms closing 40...75 ms opening Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability Operating rate 8 Mcycles 1200 cyc/h at <= 140 F (60 C) Complementary Coil technology Control circuit voltage limits Inrush power in VA Hold-in power consumption in VA Heat dissipation Built-in bidirectional peak limiting diode suppressor 0.3...0.5 Uc drop-out at 131 F (55 C), AC 50/60 Hz 0.8...1.15 Uc operational at 131 F (55 C), AC 50/60 Hz 280...350 VA at 68 F (20 C) (cos ϕ 0.9) 60 Hz 280...350 VA at 68 F (20 C) (cos ϕ 0.9) 50 Hz 2...18 VA at 68 F (20 C) (cos ϕ 0.9) 60 Hz 2...18 VA at 68 F (20 C) (cos ϕ 0.9) 50 Hz 3...4.5 W at 50/60 Hz Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1 Type mirror contact (1 NC) conforming to IEC 60947-4-1 Signalling circuit frequency Minimum switching current Minimum switching voltage Non-overlap time Insulation resistance 25...400 Hz 5 ma signalling circuit 17 V signalling circuit 1.5 ms on de-energisation (between NC and NO contact) 1.5 ms on energisation (between NC and NO contact) > 10 MOhm signalling circuit Environment IP degree of protection IP20 front face conforming to IEC 60529 Protective treatment TH conforming to IEC 60068-2-30 Pollution degree 3 Ambient air temperature for operation Ambient air temperature for storage Permissible ambient air temperature around the device Operating altitude 23...140 F (-5...60 C) -76...176 F (-60...80 C) -40...158 F (-40...70 C) at Uc 9842.52 ft (3000 m) without derating in temperature Fire resistance 1562 F (850 C) conforming to IEC 60695-2-1 Flame retardance V1 conforming to UL 94 Mechanical robustness Height Width Depth Product weight Vibrations contactor open 2 Gn, 5...300 Hz Vibrations contactor closed 4 Gn, 5...300 Hz Shocks contactor closed 15 Gn for 11 ms Shocks contactor open 6 Gn for 11 ms 6.22 in (158 mm) 4.72 in (120 mm) 5.35 in (136 mm) 5.51 lb(us) (2.5 kg) Ordering and shipping details Category 22345 - CTR,D-LINE,OPEN,NONREV-NEW Discount Schedule I12 GTIN 00785901475996 Nbr. of units in pkg. 1 Package weight(lbs) 5.4299999999999997 3

Returnability Country of origin Y CZ Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Green Premium product Compliant - since 0927 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Available Product Environmental Profile Product end of life instructions Available California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months 4

Product data sheet Dimensions Drawings LC1D150B7 Dimensions (1) Minimum electrical clearance LC1 D115 and D150 (3-pole) a 120 b1 with LA4 DA2 174 with LA4 DF, DT 185 with LA4 DM, DL 188 with LA4 DW 188 c without cover or add-on blocks 132 with cover, without add-on blocks 136 c1 with LAD N or C (2 or 4 contacts) 150 c2 with LA6 DK20 155 c3 with LAD T, R, S 168 with LAD T, R, S and sealing cover 172 5

Product data sheet Connections and Schema LC1D150B7 Wiring 6