80G1 PRODUCT SPECIFICATIONS GAS FURNACE SINGLE STAGE CONFIGURATIONS HEAT EXCHANGER DESIGN CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

Similar documents
A801D PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE INSTALLATION FEATURES

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Chinook Gas Furnace Multi-Position High Efficiency Condensing Furnace

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 120,000 BTUH S9V2D120D5-SUB-1-EN. March 2016 S9V2D120D5PSAA TAG:

Ultra Quiet Series Electric Air Handler

Split System Air Conditioner


P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating

TECHNICAL SERVICE. DATE: August 02, 2007 ST

P65-5. Output Ratings. Dimensions and Weights. Prime Rating

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

P Output Ratings. Dimensions and Weights. Prime Rating

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

P1000P1/P1100E1 50Hz

P Output Ratings. Dimensions and Weights. Prime Rating

P800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

Series 8800 Radial Tip Fans Design 8812

P1350P1/P1500E1 50Hz

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

ITherrnolék BI-T UTILITY SET - GENERAL DUTY (800) Cootmetcat Ver iarisn Syse. ns. cfm

TX33 Models 28 W/ F (50 W/ C) TX23 Models 14 W/ F (25 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C)

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

Series 7600 Centrifugal Airfoil Fan

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow

Agilent High Capacity RV Pumps & Roots Pumping Systems

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

Features. Specifications. Finish. Notes

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

Twin City Fan & Blower

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

DOWNDRAFT SANDING TABLES

APQ Series Type C Power Factor Correction Banks

ModuMAX SSPA Systems C, X, and Ku-Bands

T BTU/Hr Watts. T BTU/Hr Watts. Finish. Accessories. Options

SPECIFICATION NO Model 207 Automatic GTAW Welding System

THE XZIEX INDUSTRIAL / COMMERCIAL ATMOSPHERIC WATER GENERATOR SYSTEMS Technical Specifications

AS09..S 3-pole Contactors - Spring Terminals

E-VENT. The turnkey plasma cutting machine. Technica l progress in the design

Please take a few minutes to read this manual so that you will better understand the featues and capabilities of your MF80. MF80 Owner s Manual 1

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

CR BTU/Hr. 469 Watt. CR and 4000 BTU/Hr. 791 and 1172 Watts CR & 8000 BTU/Hr and 2344 Watts.

Bulletin IND05 INDUSTRACON

Air Flow Static Pressure Characteristics MU1238A MU1238B MU1238L. Static Pressure. Static Pressure. Speed [r/min] [Pa] Speed

T BTU/Hr Watts

Model KBF P 240 Humidity test chambers with ICH-compliant light source

ModuMAX SSPA Systems. C, X, and Ku Bands. Completely modular solid-state power amplifier systems for world-wide satellite communications

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

PLANNING GUIDE VENTILATION

Okta 1000, Roots pump without motor

AC1036. Definite Purpose Contactors

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

YLAA YLAA0175 AIR-COOLED SCROLL CHILLERS STYLE A, B or C (60 Hz) TON KW

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE MIXED FLOW INDUCED FLOW EXHAUST FANS. Model TVIFE

GENESIS Indoor Air Conditioners

T-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

10 PDUs 19 PDUs Zero-U PDUs

M BTU/Hr Watts. Finish. Options

Variable speed drives Altivar 38 Mastering elements for more comfort

WCHE BTU/Hr Watts

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

Model KBF 115 Constant climate chambers with large temperature / humidity range

SPECIFICATION NO NOTE

Tube Rotator. User Guide. Version 1.2

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

MHB BTU/Hr Watt

Direct PWM. 1000/2000 Series POWERBLOK MODULE

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

PRIMEROYAL Series. Metering Pump. Model PN

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Series. Processes TIG (GTAW) MIG (GMAW) Plasma Cutting Resistance Welding. Coolmate V3. Coolant systems are warranted for 1 year, parts and labor.

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

TeSys circuit-breakers

T BTU/Hr Watts

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

CME500 SERVICE PARTS

Installation Operation Maintenance

Prodigy Eclipse ECC and EH222 Service Parts EH222 Cabinet - C Series

Harmonic correction unit (HCU2)

Customer Responsibilities. Important Customer Information. Agilent 1260 Infinity Clinical ed. LC Site Preparation Checklist

ULTRALOW TEMPERATURE FREEZERS -86 C

Air Conditioners. CR Compact, Mid-Size and Full-Size Air Conditioners and Accessories

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Model KT 115 Cooling incubators with thermoelectric cooling

Compact Vacuum Systems

Fluid Cooling P-BAR b Industrial BOL Series

Chloride EDP Series Three-Phase UPS ( kva): The EDP Series UPS is designed

Transcription:

80G1 PRODUCT SPECIFICATIONS GAS FURNACE SINGLE STAGE FORM NO. 80G1-100 (10/2018) CONFIGURATIONS Upflow / Horizontal Downflow HEAT EXCHANGER DESIGN Crimped no-weld aluminized clam shell heat exchanger construction CABINET DESIGN Compact 33 height Standardized widths for easy coil fit AIR DELIVERY SYSTEM Multi-speed PSC blower motor Easily removable slide out blower design CONTROLS Single stage gas valve Self diagnostics saving last 5 fault codes regardless of power interruption VENTING Rotatable draft inducer for venting flexibility INSTALLATION FEATURES Left or right utility connections "L" designated models comply with California's South Coast Air Quality Management district Low NOx requirements Removable floor base for bottom return air Zero step horizontal conversion WARRANTY 10-Year limited parts warranty / lifetime heat exchanger warranty available. See limited warranty document for details. Note: Not Sold In Canada California Only If installed in South Coast Air Quality Management District (SCAQMD) only: This furnace does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/j), and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.cleanairfurnacerebate.com. If installed in San Joaquin Valley Air Pollution Control District (SJVAPCD) only: This furnace does not meet the SJVAPCD Rule 4905 NOx emission limit (14 ng/j), and thus is subject to a mitigation fee of up to $450. Page 1

MODEL NUMBER GUIDE 80 G 1 UH 110 C P 20 L 1 AFUE 80 = 80% EFFICENCY GAS G = GAS STAGES 1 = ONE STAGE CONFIGURATION UH = UPFLOW/HORIZONTAL BTUH INPUT HEATING INPUT X 1000 CABINET WIDTH A = 14.5 WIDTH B = 17.5 WIDTH C = 21.0 WIDTH REV CODE REVISION LOW NOx NOM. CFM X 100 08 = 2 TON ADD ON COOLING 12 = 3 TON ADD ON COOLING 16 = 4 TON ADD ON COOLING 20 = 5 TON ADD ON COOLING BLOWER DRIVE P = PSC E = HIGH EFFICENCY V= VARIABLE SPEED PHYSICAL AND ELECTRICAL DATA Model Input (Btuh) Output (Btuh) AFUE (ICS) % Nom. Cooling Capacity Gas Inlet (in.) Volts/ Hz/ Phase Max. Time Delay Breaker or Fuse Nominal F.L.A. Trans. (V.A.) Approx. Shipping Weight (lbs.) 80G1UH045AP12 44,000 35,000 80.0% 2-3 1/2 120-60-1 15 6.1 40 110 80G1UH070AP08 66,000 54,000 80.0% 1.5-2 1/2 120-60-1 15 3.1 40 114 80G1UH070AP12 66,000 54,000 80.0% 2-3 1/2 120-60-1 15 6.1 40 119 UPFLOW / HORIZONTAL 80G1UH090BP12 88,000 71,000 80.0% 2-3 1/2 120-60-1 15 6.1 40 131 80G1UH090BP16 88,000 71,000 80.0% 3-4 1/2 120-60-1 15 8.2 40 183 80G1UH110CP12 110,000 88,000 80.0% 2-3 1/2 120-60-1 15 6.1 40 144 80G1UH110CP16 110,000 89,000 80.0% 3-4 1/2 120-60-1 15 8.2 40 151 80G1UH110CP20 110,000 89,000 80.0% 4-5 1/2 120-60-1 15 10 40 161 80G1UH135DP20 132,000 107,000 80.0% 4-5 1/2 120-60-1 15 10 40 174 80G1UH045AP12L 44,000 35,000 80.0% 2-3 1/2 120-60-1 15 6.1 40 110 80G1UH070AP12L 66,000 54,000 80.0% 2-3 1/2 120-60-1 15 6.1 40 119 80G1UH090BP16L 88,000 71,000 80.0% 3-4 1/2 120-60-1 15 8.2 40 138 80G1UH110CP20L 110,000 89,000 80.0% 4-5 1/2 120-60-1 15 10 40 161 DOWNFLOW 80G1DF 045 AP12 44,000 35,200 80.0% 2-3 1/2 120-60-1 15 6.1 40 112 80G1DF 070 AP12 66,000 52,800 80.0% 2-3 1/2 120-60-1 15 6.1 40 121 80G1DF 090 BP16 88,000 70,400 80.0% 3-4 1/2 120-60-1 15 8.2 40 140 80G1DF 110 CP20 110,000 88,000 80.0% 4-5 1/2 120-60-1 15 10 40 163 Note: For vent length and clearances to combustibles, please reference installation instructions. Page 2

BLOWER PERFORMANCE DATA CFM @ External Static Pressure - " w.c. Model Motor (hp) Temp Rise ( F) Speed 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 High 1571 1527 1472 1399 1329 1223 1137 1020 80G1UH045A12(L) 10 x 8 15-45 Med/High 1332 1314 1277 1233 1186 1136 1008 929 Med 1115 1139 1127 1086 1050 994 926 819 Low 950 952 944 924 887 842 783 648 High 1113 1086 1045 1014 964 891 811 713 80G1UH070A08 1/5 (3 spd) 10 x 7 30-60 Med/High 974 953 927 886 834 781 702 563 Low 822 791 775 733 702 637 562 422 High 1579 1522 1479 1402 1338 1247 1158 1047 80G1UH070A12(L) 10 x 8 30-60 Med/High 1357 1333 1300 1268 1205 1125 1045 942 Med 1137 1131 1102 1080 1037 977 913 828 Low 958 956 943 925 879 837 777 725 High 1724 1683 1631 1535 1469 1363 1257 1158 UPFLOW / HORIZONTAL 80G1UH090B12 80G1UH090B16(L) 80G1UH110C12 1/2 10 x 9 25-55 10 x 10 25-55 10 x 10 45-75 Med/High 1420 1410 1368 1314 1273 1183 1103 1002 Med 1171 1168 1150 1126 1084 1022 935 817 Low 973 978 957 927 908 840 784 680 High 1911 1840 1770 1663 1584 1469 1357 1198 Med/High 1738 1707 1634 1560 1468 1364 1232 1121 Med 1533 1502 1462 1408 1329 1262 1157 1019 Low 1303 1304 1281 1225 1192 1116 1018 918 High 1625 1605 1595 1550 1485 1385 1275 1040 Med/High 1300 1290 1305 1260 1225 1145 1010 875 Med 1045 1050 1045 1010 970 910 815 660 Low 880 880 830 835 800 730 635 535 High 2078 2017 1939 1848 1775 1679 1559 1425 80G1UH110C16 1/2 10 x 10 25-55 Med/High 1791 1746 1693 1635 1573 1469 1349 1192 Med 1542 1547 1507 1472 1395 1322 1203 1060 Low 1334 1333 1321 1293 1237 1172 1050 909 High 2420 2304 2247 2156 2067 1988 1890 1742 80G1UH110C20(L) 3/4 11 x 10 25-55 Med/High 2230 2173 2113 2056 1985 1891 1764 1653 Med 1987 1954 1901 1841 1800 1703 1618 1491 Low 1796 1759 1715 1674 1616 1552 1465 1359 High 2120 2042 1972 1863 1747 1618 1488 1336 80G1UH135D20 3/4 11 x 11 30-60 Med/High 2044 1948 1864 1790 1654 1563 1413 1312 Med 1886 1817 1762 1672 1603 1461 1357 1228 Low 1728 1664 1616 1526 1441 1366 1260 1136 Page 3

BLOWER PERFORMANCE DATA (CONTINUED FROM PREVIOUS PAGE) CFM @ External Static Pressure - " w.c. Model Motor (hp) Temp Rise (F ) Speed 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 High 1465 1414 1343 1255 1205 1140 1031 926 80G1DF045BP12 10 x 8 15-45 Med/High 1351 1293 1236 1190 1106 1059 962 850 Med 1129 1111 1083 1038 999 943 870 764 Low 943 950 945 897 870 816 739 653 High 1506 1459 1390 1306 1213 1140 1038 927 DOWNFLOW 80G1DF070BP12 80G1DF090CP16 1/2 11 x 8 25-55 10 x 10 25-55 Med/High 1355 1314 1264 1200 1129 1066 975 865 Med 1149 1119 1082 1048 987 901 836 727 Low 953 941 915 904 849 798 717 628 High 1864 1779 1694 1596 1483 1340 1221 1065 Med/High 1745 1676 1600 1502 1413 1273 1138 1007 Med 1544 1496 1443 1363 1258 1148 1018 904 Low 1321 1296 1265 1212 1148 1042 917 812 High 2416 2328 2232 2149 2017 1920 1789 1657 80G1DF110CP20 3/4 11 x 10 30-60 Med/High 2248 2193 2122 2048 1923 1825 1728 1594 Med 2087 2021 1975 1905 1806 1727 1625 1487 Low 1861 1812 1771 1728 1648 1560 1471 1351 Page 4

DIMENSIONS (IN.) Model A B C D 80G1UH045AP12 14-1/2 13-3/8 13 4-3/4 80G1UH070AP08 14-1/2 13-3/8 13 4-3/4 Front 80G1UH070AP12 14-1/2 13-3/8 13 4-3/4 UPFLOW / HORIZONTAL 80G1UH090BP12 17-1/2 16-3/8 16 6-1/4 80G1UH090BP16 17-1/2 16-3/8 16 6-1/4 80G1UH110CP12 21 19-3/8 19-1/2 8 80G1UH110CP16 21 19-3/8 19-1/2 8 80G1UH110CP20 21 19-3/8 19-1/2 8 80G1UH135DP20 24-1/2 23-3/8 23 9-3/4 80G1UH045AP12L 14-1/2 13-3/8 13 4-3/4 80G1UH070AP12L 14-1/2 13-3/8 13 4-3/4 80G1UH090BP16L 17-1/2 16-3/8 16 6-1/4 80G1UH110CP20L 21 19-3/8 19-1/2 8 DOWNFLOW 80G1DF 045 AP12 14-1/2 13-3/8 13 4-3/4 80G1DF 070 AP12 14-1/2 13-3/8 13 4-3/4 80G1DF 090 BP16 17-1/2 16-3/8 16 6-1/4 80G1DF 110 CP20 21 19-7/8 19-1/2 8 Top Upflow / Horizontal Downflow Right Side Right Side Bottom Bottom Page 5

ACCESSORY LIST CATALOG NUMBER DESCRIPTION External Filter Rack kits 1.841018 1 Pack (16x25) 1.841039 10 Pack (16x25) Natural to LP Kits 11K50 1-Stage - 80 11K45 High Altitude 1-Stage (<4500ft.) Return Air Base 68W61 68W62 68W63 68W64 14.5", A Width 17.5, B Width 21.0, C Width 24.5", D Width Downflow Combustible Flooring Base 11M59 11M60 11M61 14.5", A Width 17.5, B Width 21.0, C Width Night Service Kits 68W80 Single Stage Horizontal Suspension Kit 51W10 80% & 90% Kit Note: For vent length and clearances to combustibles, please reference installation instructions. All specifications and illustrations subject to change without notice and without incurring obligations. 1-800-448-5872 FORM NO. 80G1-100 (10/2018) 2018 Allied Air Enterprises LLC, a Lennox International Inc. Company Printed in the U.S.A. Page 6