REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Similar documents
REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

LM - 79 Reporting. Laboratory Information. Date of test report July 31 st, Product Information

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK Project No. G Date: October 29, 2010 REPORT NO CRT-001 TEST OF ONE LED DESK LAMP

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Bartco Lighting 5761 Research Drive, Huntington Beach, CA

Fixture is tested with no special conditions. No seasoning was performed in accordance with IESNA LM-79. PS-AC02 CD-SN03-S2 MT-SC01-S2 2MR97 SPR-3000

Revolution Lighting Technologies (RVLT) 2280 Ward Ave. Docks 5&6, Simi Valley, CA 93065

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

Test Report. Report Number: L15159 Date: Jan 6, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Number Eight Lighting Company 526 Portal Street, Cotati, CA 94931

ZipTwo LED - Zipper board with Diffuse Batwing Lens, High Output. IES File Performance Summary

IESNA LM79: 2008 Photometric Test Report

Number Eight Lighting Company 803/K2-HI-25-XX/DIM /FS-P-1-WH

Infinilux 5349 Zambrano St, Commerce, CA Electrical and Photometric tests as required by the IESNA test standards.

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

PHONE: (303) FAX: (970) WEBSITE:

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Fuel Pump Canopy Luminaires

NVLAP LAB CODE:

NVLAP LAB CODE:

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

Photometric Test Report

Report of Test LLIA A-R01*

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

Product testing and evaluation to IES LM-79-08

NVLAP LAB CODE LM Test Report. For. EiKO Global, LLC. (Brand Name: EiKO) W. 84th St, Shawnee, KS USA

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL35-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL28-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV50-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV24-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV20-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

Photometric Test Report

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX60

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX27

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24V-BLBSC1-30-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-12-BLBSC2-50-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24-BLBSC2-30-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE Basics 100 LED Tape Light - DI-24V-BLBSC1-63-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-27-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-50-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU DI-24V-ES30-BK 3000K BLACK.

Report of Test LLIA

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L

American National Standard

Guidelines for Specification of LED Lighting Products 2010

Vaya Cove, Color. Data sheet. Philips Lighting Rev Burlington Woods Drive Burlington, MA 01803

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

PHONE: (303) FAX: (970) WEBSITE:

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED DALI

Technical Report No Dated

NOXLITE LED SPOT. Product family datasheet. Outdoor LED wall luminaires. Areas of application _ Outdoor _ Garages _ Patios, balconies

IESNA LM-79: Measurement and Test Report for Venture Lighting International Aurora Road, Suite A, Solon, OH 44139,United states

REPORT NO CRT-001h SOUND OUTPUT MEASUREMENTS ON SIX INVERTER GENERATOR SAMPLES RENDERED TO

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED

T5 LED Integrated Lamp

Evaluating and Specifying LED Lighting

PRODUCT FAMILY DATASHEET LEDVANCE SPOT LED

Transcription:

. REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: January 25, 2017 REPORT NO. 102748333CHI-019 TEST OF ONE LED AREA LIGHT MODEL NO. HPAL-NW200-BP9 LED MODEL NO. OSRAM GW PSLPS1.EC-KTLP-5H7I-1 DRIVER MODEL NO. SOSEN SS-180R-50 RENDERED TO SUPER BRIGHT LEDS, INC. 4400 EARTH CITY EPRESSWAY SAINT LOUIS, MO 63045 TEST: Electrical and Photometric tests as required to the IESNA test standard. AUTHORIZATION: The testing performed was authorized by signed quote number Qu-00723537-3. STANDARDS USED: The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen: IESNA LM-79-2008: Electrical and Photometric Measurements of Solid State Lighting ANSI NEMA ANSLG C78.377: 2012: Specifications of the of Solid State Lighting Products DESCRIPTION OF SAMPLE: The client submitted one production sample of model number HPAL-NW200-BP9. The sample was received by Intertek on January 20, 2017, in undamaged condition and one sample was tested as received. The sample designation was AH01202017035722C. DATES OF TESTS: January 23, 2017 through January 25, 2017. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

SUMMARY Model No.: Description: HPAL-NW200-BP9 LED Area Light Criteria Total Lumen Output (Lumens) Result 21814 Total Power (W) 191.3 Luminaire Efficacy (LPW) 114.0 Power Factor at 120Vac 0.998 Power Factor at 277Vac 0.936 Current ATHD % at 120Vac 4.19 Current ATHD % at 277Vac 12.64 Correlated Color Temperature (CCT - K) 5065 Color Rendering Index (CRI - Ra) 85.9 Color Rendering Index (CRI - R9) 22.1 DUV 0.001 Coordinate (x) 0.344 Coordinate (y) 0.354 Coordinate (u') 0.209 Coordinate (v') 0.486 EQUIPMENT LIST Equipment Used Yokogawa Power Meter Omega Newport Thermometer LSI High Speed Mirror Goniometer Newport Thermohygrometer Pacific, AC power supply Labsphere Spectroradiometer 3 Meter Sphere Elgar AC Power Supply Sorenson DC Power Supply Newport Humidity Recorder Yokogawa Power Meter Fluke K/J Thermometer Model Control Last Date Calibration Number Number Calibrated Due Date WT210 146919 07/11/16 07/11/17 DPI8-C24 146920 10/07/16 10/07/17 6440T 146928 VBU VBU iserver 146956 01/06/17 01/06/18 118-AC CHI0358 VBU VBU CDS1100 CHI0091 VBU VBU SPR600 CHI0088 VBU VBU CW1251M 146112 VBU VBU FR150-8 146846 VBU VBU ith-sd 146382 06/27/16 06/27/17 WT1600 146768 01/10/17 01/10/18 52 146004 01/10/17 01/10/18 Date Used Report No. 102748333CHI-019 2 of 7 Date: January 25, 2017

TEST METHODS Seasoning in Sample Orientation LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical Measurements Integrating Sphere Method A Labsphere Model CDS 1100 CCD Array Spectroradiometer and Two Meter or Ten Foot Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the itron or Yokogawa Power Analyzer. The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of Standards and Technology. Photometric and Electrical Measurements Distribution Method A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the itron or Yokogawa Power Analyzer. Some graphics were created with Photometrics Plus software. Report No. 102748333CHI-019 3 of 7 Date: January 25, 2017

RESULTS OF TEST Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) - Integrating Sphere Method Intertek Sample No. AH01202017035722C Base Orientation Up Input Input Input Input Voltage Current Power Power {Vac} (ma) (Watts) Factor 120.0 1600 191.54 0.998 277.0 726.3 188.4 0.936 Current ATHD (%) 4.19 12.64 Correlated Color CRI CRI CIE 31 CIE 31 CIE 76 CIE 76 Temperature (K) -Ra -R9 DUV Coordinate (x) Coordinate (y) Coordinate (u ) Coordinate (v ) 5065 85.9 22.1 0.001 0.344 0.354 0.209 0.486 Spectral Distribution over Visible Wavelengths nm mw/nm nm mw/nm nm mw/nm nm mw/nm nm mw/nm 350 1.910 440 229.5 530 260.2 620 245.7 710 30.17 355 1.819 445 366.3 535 266.4 625 231.8 715 26.07 360 1.986 450 438.4 540 270.7 630 216.4 720 22.56 365 1.766 455 365.4 545 274.2 635 200.2 725 19.48 370 1.657 460 282.7 550 276.4 640 183.4 730 16.78 375 1.562 465 233.5 555 278.3 645 166.6 735 14.45 380 1.604 470 184.4 560 279.8 650 150.2 740 12.45 385 1.633 475 154.5 565 281.3 655 134.7 745 10.75 390 1.835 480 148.3 570 283.2 660 119.9 750 9.333 395 2.360 485 151.3 575 285.3 665 105.8 755 8.091 400 3.396 490 160.5 580 287.3 670 93.39 760 7.070 405 410 415 420 425 430 5.589 9.667 17.01 29.39 50.77 84.36 495 500 505 510 515 520 175.4 191.3 206.6 219.7 232.7 243.8 585 590 595 600 605 610 288.0 287.8 285.7 282.4 276.8 268.5 675 680 685 690 695 700 81.83 71.58 62.33 54.08 46.95 40.62 765 770 775 780 6.144 5.322 4.588 4.010 435 138.1 525 253.0 615 258.2 705 35.01 Spectral Data Over Visible Wavelengths 500.000 450.000 400.000 350.000 300.000 250.000 200.000 150.000 100.000 50.000 0.000 350 400 450 500 550 600 650 700 750 800 (mw/nm) Nanometers Report No. 102748333CHI-019 4 of 7 Date: January 25, 2017

RESULTS OF TEST (cont'd) Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) Distribution Method Input Input Input Input Absolute Intertek Sample No. Base Orientation Voltage {Vac} Current (ma) Power (Watts) Power Factor Luminous Flux (Lumens) AH01202017035722C Up 120.1 1597 191.3 0.998 21814 Lumen Efficacy (LPW) 114.0 Intensity (Candlepower) Summary at 25 C - Candelas Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 0 22.5 45 67.5 90 11717 11717 11717 11717 11717 11645 11610 11656 11655 11654 11466 11427 11472 11473 11464 11186 11194 11172 11178 11188 10788 10772 10752 10762 10764 10204 10163 10177 10174 10181 9442 9360 9398 9395 9401 8495 8446 8448 8438 8446 7369 7311 7301 7315 7310 6074 6020 6012 6011 6016 4561 4493 4468 4464 4455 2794 2759 2751 2745 2726 1042 992 1017 1048 1042 103 108 158 175 189 72 71 74 81 82 53 51 51 56 57 41 39 35 37 38 24 22 19 18 16 0 0 0 0 0 Report No. 102748333CHI-019 5 of 7 Date: January 25, 2017

RESULTS OF TEST (cont'd) Illumination Plots Illuminance - Cone of Light Mounting Height: 10 ft. Isoillumination Plot Zonal Lumen Summary and Percentages at 25 C Zonal Lumens and Percentages at 25 C Zone 0-30 0-40 0-60 60-90 0-90 90-180 0-180 Lumens % Luminaire Zone Lumens % Luminaire 8998 41.2 0-10 1108 5.1 14317 65.6 10-20 3169 14.5 21422 98.2 20-30 4721 21.6 392.6 1.8 30-40 5319 24.4 21814 100.0 40-50 4638 21.3 0.0 0.0 50-60 2466 11.3 21814 100.0 60-70 312.6 1.4 70-80 60.5 0.3 80-90 19.5 0.1 Report No. 102748333CHI-019 6 of 7 Date: January 25, 2017

PICTURES (not to scale) CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report. In Charge Of Tests: Report Reviewed By: Jehue Williams Associate Engineer Lighting Division Timothy Quigley Engineer Lighting Division Attachment: None Report No. 102748333CHI-019 7 of 7 Date: January 25, 2017