Savant. Savant. SignalCalc. Power in Numbers input channels. Networked chassis with 1 Gigabit Ethernet to host

Similar documents
Next Generation Software Solution for Sound Engineering

Sound and Vibration Data Acquisition

Getting Started with the LabVIEW Sound and Vibration Toolkit

Sound and Vibration Data Acquisition

DT9857E. Key Features: Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Datasheet. Dual-Band airmax ac Radio with Dedicated Wi-Fi Management. Model: B-DB-AC. airmax ac Technology for 300+ Mbps Throughput at 5 GHz

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

DAC Express Release 3.4 (VT9801B)

Ultra-Wideband Scanning Receiver with Signal Activity Detection, Real-Time Recording, IF Playback & Data Analysis Capabilities

Major Differences Between the DT9847 Series Modules

EngineDiag. The Reciprocating Machines Diagnostics Module. Introduction DATASHEET

EngineDiag. The Reciprocating Machines Diagnostics Module. Introduction DATASHEET

860 DSP Digital Field Analyzer

The Design of Teaching Experiment System Based on Virtual Instrument Technology. Dayong Huo

Using the BHM binaural head microphone

SIDC-5009 Series VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

Put your sound where it belongs: Numerical optimization of sound systems. Stefan Feistel, Bruce C. Olson, Ana M. Jaramillo AFMG Technologies GmbH

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

HEAD. HEAD VISOR (Code 7500ff) Overview. Features. System for online localization of sound sources in real time

Torsional vibration analysis in ArtemiS SUITE 1

4 MHz Lock-In Amplifier

CATV & DOCSIS3.0 Meter / Analyzer. Purchase from:

MULTIMIX 8/4 DIGITAL AUDIO-PROCESSING

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

R&S TSMx Radio Network Analyzers Powerful scanner family for mobile applications

SOUND DISTRIBUTION AND DISTANCE CONFERENCING

Geode DZ. Distributed Seismic Acquisition System. 3-D Data Acquisition Simplified and Streamlined

Agilent PN Time-Capture Capabilities of the Agilent Series Vector Signal Analyzers Product Note

Spec Sheet R&S SpycerBox family

Digital Audio Design Validation and Debugging Using PGY-I2C

innovative technology to keep you a step ahead 24/7 Monitoring Detects Problems Early by Automatically Scanning Levels and other Key Parameters

Precision DeEsser Users Guide

Synthesized Block Up- and Downconverter Indoor / Outdoor

2 MHz Lock-In Amplifier

HCS-4100/20 Series Application Software

Transporting NV Standardized Testing from the Lab to the Production Environment

Fieldbus Testing with Online Physical Layer Diagnostics

A New "Duration-Adapted TR" Waveform Capture Method Eliminates Severe Limitations

DT9837 Series. High Performance, USB Powered Modules for Sound & Vibration Analysis. Key Features:

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

2 MHz Lock-In Amplifier

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

Fa m i l y o f PXI Do w n c o n v e r t e r Mo d u l e s Br i n g s 26.5 GHz RF/MW

DESIGN PHILOSOPHY We had a Dream...

Meeting Embedded Design Challenges with Mixed Signal Oscilloscopes

Scanning A/D Converters, Waveform Digitizers, and Oscilloscopes

DS2460Q QAM Analysis Meter

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

EMI/EMC diagnostic and debugging

innovative technology to keep you a step ahead Tailored to Simplify Installation and Troubleshooting of RF Signals

DOCSIS 3.1 roll Out First Lessons Learned DOCSIS 3.1 roll Out First Lessons Learned

PAK 5.9. Interacting with live data.

Real-Time Spectrogram (RTS tm )

An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR

USER S GUIDE DSR-1 DE-ESSER. Plug-in for Mackie Digital Mixers

MAP Optical Power Meter Module (mopm-b1)

Radar signal interception moves into the digital age. Innovative ELINT solution from Rohde & Schwarz. Radar signal interception

Instrumentation Grade RF & Microwave Subsystems

February 2013 Volume 7 - Number 2 Inside the Insider Welcome to the Insider Corporate News SignalCalc and SignalStar SignalForce and SignalSound

innovative technology to keep you a step ahead Tailored to Simplify Installation and Troubleshooting of RF Signals

SAGE Instruments UCTT 8901 Release Notes

Datasheet. High-Performance airmax Bridge. Models: PBE-M5-620, PBE-M5-400, PBE-M5-300, PBE-M Uniform Beamwidth Maximizes Noise Immunity

dsunzh; Je lalfkku,u-,l- eadhdj ekxz] सञयन] म

DNT0212 Network Processor

Flexible High Speed Recording. Wideband recording of IF & RF signals

Linrad On-Screen Controls K1JT

Agilent CSA Spectrum Analyzer N1996A

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

StepArray+ Self-powered digitally steerable column loudspeakers

MTS/T-BERD Platforms WDMPMD Module

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

DNT0212 Network Processor

VR5 HD Spatial Channel Emulator

4T2-Portable test set DVB terrestrial analyser system

SNG-2150C User s Guide

R e c e i v e r. Receiver

OMNISTAR GX2. GX2-LM1000E Series 1310 nm Broadcast Transmitter DATA SHEET BENEFITS. 1 GHz bandwidth

Agilent E3238 VHF/UHF Voice Activity Detection System

THE DIAGNOSTICS BACK END SYSTEM BASED ON THE IN HOUSE DEVELOPED A DA AND A D O BOARDS

Pre-processing of revolution speed data in ArtemiS SUITE 1

Solutions to Embedded System Design Challenges Part II

DESIGNING OPTIMIZED MICROPHONE BEAMFORMERS

High Performance Real-Time Software Asynchronous Sample Rate Converter Kernel

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

Work no. 2. Doru TURCAN - dr.ing. SKF Romania Gabriel KRAFT - dr.ing. SKF Romania

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

4T2 Content-Analyser

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules

MTS/T-BERD 8000 Platform

Qs7-1 DEVELOPMENT OF AN IMAGE COMPRESSION AND AUTHENTICATION MODULE FOR VIDEO SURVEILLANCE SYSTEMS. DlSTRlBUllON OF THIS DOCUMENT IS UNLlditEb,d

The Turbomachinery Vibration Software

CEDAR Series. To learn more about Ogden CEDAR series signal processing platform and modular products, please visit

Building Video and Audio Test Systems. NI Technical Symposium 2008

Multiroom Multimedia Distribution

Selecting a High Performance Multi-Touch Display

HIGH SPEED ASYNCHRONOUS DATA MULTIPLEXER/ DEMULTIPLEXER FOR HIGH DENSITY DIGITAL RECORDERS

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

Transcription:

Power in Numbers Savant SignalCalc 40-1024 input channels Networked chassis with 1 Gigabit Ethernet to host 49 khz analysis bandwidth, all channels with simultaneous storage to disk SignalCalc Dynamic Signal Analyzers Savant

SignalCalc Dynamic Signal Analyzers Savant Catering to the challenges of large channel count applications SignalCalc Savant maintains realtime analysis, accurate cross channel measurement and recording rate performances for thousand channel systems. The distributed architecture further allows you to place data acquisition close to the measuring transducers thereby eliminating the error due to mismatched transducer cables. Standard Features Auto Power Spectrum Transfer Function (FRF) Synchronous Average Correlation Histogram Realtime Zoom Optional: Multiple Input Multiple Output (MIMO) Shock Response Spectrum (SRS) Stepped Sine RPM Based Measurements Order Tracking Demodulation Rotordynamics Waterfall and Spectrogram Realtime Octave Acoustic Intensity Sound Quality - Loudness Disk Recording, Analysis and DAC Playback Event Capture Environmental Data Reduction, Notching Prediction, Alarm & Abort

SignalCalc Savant is powered by Abacus, the modular DSPcentric signal analysis engine designed for high bandwidth and high precision. Savant incorporates the SignalCalc user interface acclaimed for its intuitive operation and ability to make the expert productive while allowing the novice to be comfortable. Facilitating Large Applications Extensive Functionality Flexible and Scalable The data acquisition and signal analysis system is at the heart of large channel count applications. It Savant features the SignalCalc user interface and analysis software packed with usability features. The The distributed network architecture of Abacus, allows Savant to spread its 32 channel measurement needs to be able to acquire 100 s of channels of response transducers simultaneously while outputting extensive functionality of the SignalCalc user interface provides you with easy, flexible set-up, display, and units over large distances, by as much as 30 meters between units. Savant delivers high precision multiple drive signals when external excitation to the structure is needed. It also requires sophisticated networking. Control panels, where test set-up parameters can be quickly entered into pop-up dialog results over a 120dB to 150dB dynamic range and brings superior DSP power to handle the challenges displays and automation features geared towards simplification of the data visualization and analysis. boxes, can float or dock to a convenient location for easy access. Powerful graphics allow viewing of of signal analysis applications requiring large number of channels. Last but not least, it requires data exchange with other software applications to compare and validate results with complete flexibility of screen organization. The sizes, locations, contents, and formats of analytical models. control panels and graphics are entirely up to you. To facilitate exchange of data in a global test Any SignalCalc Savant system may be upgraded in the field to add new hardware and software environment, Savant exports measurements, waterfalls, and test parameters to popular third-party capabilities. Input and output channel count may be expanded without returning the module to the formats. factory. Every software module may be subsequently added to expand the repertoire of a system initially purchased for more limited applications. Setting up measurements is made easy by the inclusion of a transducer database and, TEDS support for automatic entry of transducer sensitivities, overall data management is simplified by the SignalMap and effective data visualization is achieved through the layout manager that provides unlimited personal display layouts. Scalable Architecture The architecture allows 8 channel boards to be combined to make 32 channel subsystems which in turn can be connected on a 1 Gigabit network to make a thousand channel system. The modularity allows a dynamics laboratory to use portable instruments of varying sizes which can be united to form a large channel count system for occasional use in larger applications. High End Noise & Vibration Solution No mater what size of system you choose Savant provides the same realtime bandwidth, the same Savant comes with the full suite of noise and vibration measurement you can expect from SignalCalc. Over high accuracy for cross channel measurements and the same gap free recording to disk during the years, SignalCalc has grown to a comprehensive set of measurement types covering general FFT analysis, measurement. data recording and playback analysis, environmental testing, structural analysis, acoustics, machinery diagnostics and reporting. Powered by

SignalCalc Savant is powered by Abacus, the modular DSPcentric signal analysis engine designed for high bandwidth and high precision. Savant incorporates the SignalCalc user interface acclaimed for its intuitive operation and ability to make the expert productive while allowing the novice to be comfortable. Facilitating Large Applications Extensive Functionality Flexible and Scalable The data acquisition and signal analysis system is at the heart of large channel count applications. It Savant features the SignalCalc user interface and analysis software packed with usability features. The The distributed network architecture of Abacus, allows Savant to spread its 32 channel measurement needs to be able to acquire 100 s of channels of response transducers simultaneously while outputting extensive functionality of the SignalCalc user interface provides you with easy, flexible set-up, display, and units over large distances, by as much as 30 meters between units. Savant delivers high precision multiple drive signals when external excitation to the structure is needed. It also requires sophisticated networking. Control panels, where test set-up parameters can be quickly entered into pop-up dialog results over a 120dB to 150dB dynamic range and brings superior DSP power to handle the challenges displays and automation features geared towards simplification of the data visualization and analysis. boxes, can float or dock to a convenient location for easy access. Powerful graphics allow viewing of of signal analysis applications requiring large number of channels. Last but not least, it requires data exchange with other software applications to compare and validate results with complete flexibility of screen organization. The sizes, locations, contents, and formats of analytical models. control panels and graphics are entirely up to you. To facilitate exchange of data in a global test Any SignalCalc Savant system may be upgraded in the field to add new hardware and software environment, Savant exports measurements, waterfalls, and test parameters to popular third-party capabilities. Input and output channel count may be expanded without returning the module to the formats. factory. Every software module may be subsequently added to expand the repertoire of a system initially purchased for more limited applications. Setting up measurements is made easy by the inclusion of a transducer database and, TEDS support for automatic entry of transducer sensitivities, overall data management is simplified by the SignalMap and effective data visualization is achieved through the layout manager that provides unlimited personal display layouts. Scalable Architecture The architecture allows 8 channel boards to be combined to make 32 channel subsystems which in turn can be connected on a 1 Gigabit network to make a thousand channel system. The modularity allows a dynamics laboratory to use portable instruments of varying sizes which can be united to form a large channel count system for occasional use in larger applications. High End Noise & Vibration Solution No mater what size of system you choose Savant provides the same realtime bandwidth, the same Savant comes with the full suite of noise and vibration measurement you can expect from SignalCalc. Over high accuracy for cross channel measurements and the same gap free recording to disk during the years, SignalCalc has grown to a comprehensive set of measurement types covering general FFT analysis, measurement. data recording and playback analysis, environmental testing, structural analysis, acoustics, machinery diagnostics and reporting. Powered by

SignalCalc Savant is powered by Abacus, the modular DSPcentric signal analysis engine designed for high bandwidth and high precision. Savant incorporates the SignalCalc user interface acclaimed for its intuitive operation and ability to make the expert productive while allowing the novice to be comfortable. Facilitating Large Applications Extensive Functionality Flexible and Scalable The data acquisition and signal analysis system is at the heart of large channel count applications. It Savant features the SignalCalc user interface and analysis software packed with usability features. The The distributed network architecture of Abacus, allows Savant to spread its 32 channel measurement needs to be able to acquire 100 s of channels of response transducers simultaneously while outputting extensive functionality of the SignalCalc user interface provides you with easy, flexible set-up, display, and units over large distances, by as much as 30 meters between units. Savant delivers high precision multiple drive signals when external excitation to the structure is needed. It also requires sophisticated networking. Control panels, where test set-up parameters can be quickly entered into pop-up dialog results over a 120dB to 150dB dynamic range and brings superior DSP power to handle the challenges displays and automation features geared towards simplification of the data visualization and analysis. boxes, can float or dock to a convenient location for easy access. Powerful graphics allow viewing of of signal analysis applications requiring large number of channels. Last but not least, it requires data exchange with other software applications to compare and validate results with complete flexibility of screen organization. The sizes, locations, contents, and formats of analytical models. control panels and graphics are entirely up to you. To facilitate exchange of data in a global test Any SignalCalc Savant system may be upgraded in the field to add new hardware and software environment, Savant exports measurements, waterfalls, and test parameters to popular third-party capabilities. Input and output channel count may be expanded without returning the module to the formats. factory. Every software module may be subsequently added to expand the repertoire of a system initially purchased for more limited applications. Setting up measurements is made easy by the inclusion of a transducer database and, TEDS support for automatic entry of transducer sensitivities, overall data management is simplified by the SignalMap and effective data visualization is achieved through the layout manager that provides unlimited personal display layouts. Scalable Architecture The architecture allows 8 channel boards to be combined to make 32 channel subsystems which in turn can be connected on a 1 Gigabit network to make a thousand channel system. The modularity allows a dynamics laboratory to use portable instruments of varying sizes which can be united to form a large channel count system for occasional use in larger applications. High End Noise & Vibration Solution No mater what size of system you choose Savant provides the same realtime bandwidth, the same Savant comes with the full suite of noise and vibration measurement you can expect from SignalCalc. Over high accuracy for cross channel measurements and the same gap free recording to disk during the years, SignalCalc has grown to a comprehensive set of measurement types covering general FFT analysis, measurement. data recording and playback analysis, environmental testing, structural analysis, acoustics, machinery diagnostics and reporting. Powered by

Distributed by: Distributed by: Data Physics has been supplying high performance test and measurement solutions for over 20 years. With the addition of a full line of electrodynamic shakers to complement its vibration controllers and dynamic signal analyzers, Data Physics is a total solution supplier for noise and vibration applications.