REPORT 545 E. Algonquin Rd., Arlington Heights, IL 65 Project No. G113575 Date: February 4, 214 REPORT NO. 113575CHI-1 TEST OF ONE LOW VOLTAGE LED TAPE LIGHT - ONE FOOT MODEL NO. DI-V-AV3-9** RENDERED TO ELEMENTAL LED, INC. DBA DIODE LED 1195 PARK AVENUE, STE. 211 EMERYVILLE, CA 98 TEST: Electrical and Photometric tests as required to the IESNA test standard. STATEMENT OF LIMITATION: AUTHORIZATION: STANDARDS USED: This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The testing performed was authorized by signed quote number 554193. The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen: IESNA LM-79 - : Electrical and Photometric Measurements of Solid State Lighting ANSI NEMA ANSLG C78.377: 212: Specifications of the of Solid State Lighting Products DESCRIPTION OF SAMPLE: The client submitted one production sample of model number DI-V-AV3-9**. The sample was received by Intertek on January 29, 214, in undamaged condition and one sample was tested as received. The sample designation was 12921413C. DATES OF TESTS: January 3, 214 through February 4, 214. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
SUMMARY Model No.: Description: DI-V-AV3-9** Low Voltage LED Tape Light - One Foot Criteria Total Lumen Output (Lumens) Total (W) Luminaire Efficacy (LPW) Sphere 2.9 2.113 72.36 Result Goniometer 1.5 2.81 72.8 Criteria Factor Current ATHD % Correlated Color Temperature (CCT - K) Color Rendering Index (CRI - Ra) Color Rendering Index (CRI - R9) DUV Coordinate (x) Coordinate (y) Coordinate (u') Coordinate (v') Result 1. n/a 2968 92.3 67.3.3.435.396.253.8 EQUIPMENT LIST Equipment Used Labsphere Spectroradiometer, 2M Sphere Omega Thermometer Yokogawa Meter Sorenson DC Supply Sorenson DC Supply Newport Thermohygrometer Yokogawa Meter Omega Thermometer LSI High Speed Mirror Goniometer Newport Hygrometer Elgar, AC Supply Cole-Parmer Triple Timer Model Number Control Number Last Date Calibrated Calibration Due Date CDS11 1137 MDSi8 WT16 XFR-8 XFR35-35 1873 1767 1847 185 8/26/13 5/18/13 8/26/14 5/18/14 THX-M 1382 8/26/13 8/26/14 WT21 DPI8-C 6T iserver CW12P 94-1919 192 19 1956 1918 CHI41 9/6/13 12/4/13 1/2/14 6/2/13 9/6/14 12/4/14 1/2/ 6/2/14 Report No. 113575CHI-1 2 of 7 Date: February 4, 214
TEST METHODS Seasoning in Sample Orientation LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical Measurements Integrating Sphere Method A Labsphere Model CDS 11 CCD Array Spectroradiometer and Two Meter Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Analyzer. The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of Standards and Technology. Photometric and Electrical Measurements Distribution Method A LSI Type C High Speed Model 6 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Analyzer. Some graphics were created with Photometrics Plus software. Report No. 113575CHI-1 3 of 7 Date: February 4, 214
RESULTS OF TEST Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) - Integrating Sphere Method Intertek Sample No. 12921413C Base Orientation UP Voltage {Vdc}. Current (ma) (Watts) Factor Current ATHD (%) Luminous Flux (Lumens) 88.3 2.113 1. n/a 2.9 Lumen Efficacy (LPW) 72.36 Correlated Color Temperature (K) 2968 CRI CRI -Ra -R9 DUV 92.3 67.3.3 CIE 31 Coordinate (x).435 CIE 31 Coordinate (y).396 CIE 76 Coordinate (u ).253 CIE 76 Coordinate (v ).8 Spectral Distribution over Visible Wavelengths nm mw/nm nm mw/nm nm mw/nm nm mw/nm nm 35.1.892 53 1.593 62 2.888 71 355.12 5 1.389 535 1.672 625 2.918 7 36.1 45 1.577 54 1.754 63 2.925 72 365.11 455 1.331 545 1.834 635 2.97 725 37.9 1.8 55 1.911 64 2.862 73 375.9 5.92 555 1.988 645 2.788 735 38.8 47.739 56 2.62 65 2.689 74 385.7 475.639 565 2.139 655 2.572 745 39.8.619 57 2.211 66 2.433 75 395.8 5.6 575 2. 665 2.278 755 4.1.73 58 2.354 67 2.114 76 45. 5.8 585 2.6 675 1.95 765 41.29 5.982 59 2.7 68 1.786 77 4.55 55 1.11 595 2.568 685 1.62 775. 1.227 6 2.645 69 1.459 78 5.188 5 1.334 65 2.72 695 1.35 43.3 52 1.43 61 2.786 7 1.165 435.8 525 1.1 6 2.847 75 1.31 mw/nm.911.8.71.612.5.1.397.3.295.254.219.189.162.138.118 Spectral Data Over Visible Wavelengths 3.5 3. 2.5 (mw/nm) 2. 1.5 1..5. 35 4 45 5 55 6 65 7 75 8 Nanometers Report No. 113575CHI-1 4 of 7 Date: February 4, 214
RESULTS OF TEST (cont'd) Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) Distribution Method Intertek Sample No. 12921413C Base Orientation UP Voltage {Vdc}. Current (ma) 86.7 (Watts) 2.81 Factor 1. Absolute Luminous Flux (Lumens) 1.5 Lumen Efficacy (Lumens Per Watt) 72.8 Intensity (Candlepower) Summary at 25 C - Candelas Angle 5 1 2 25 3 35 4 45 5 55 6 65 7 75 8 85 9 45 5 5 5 47 45 43 4 36 2 11 6 2 22.5 5 39 36 2 16 11 6 3 5 5 39 36 2 67.5 5 39 35 2 11 11 6 7 3 3 1 1 9 5 38 35 19 11 7 3 Report No. 113575CHI-1 5 of 7 Date: February 4, 214
RESULTS OF TEST (cont'd) Illumination Plots Illuminance - Cone of Light Mounting Height: 1 ft. Isoillumination Plot Zonal Lumen Summary and Percentages at 25 C Zonal Lumens and Percentages at 25 C Zone -3-4 -6 6-9 -9 9-18 -18 Lumens 39.9 65.8 117.7 33.6 1.3.2 1.5 % Luminaire 26.4 43.4 77.7 22.2 99.9.1 1. Zone -1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-9 9-1 Lumens 4.8 13.9 21.2 25.9 27.1.8 19.2 11.1 3.4.2 % Luminaire 3.2 9.2 14. 17.1 17.9 16.4 12.6 7.3 2.2.1 Report No. 113575CHI-1 6 of 7 Date: February 4, 214
PICTURE (not to scale) X CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report. In Charge Of Tests: Report Reviewed By: Tim Quigley Engineer Lighting Division Joe Schledorn Project Engineer Lighting Division Attachment: None Report No. 113575CHI-1 7 of 7 Date: February 4, 214