CAN/LIN Measurements (Option AMS) for Agilent s InfiniiVision Series Oscilloscopes

Similar documents
Keysight Technologies CAN/LIN Measurements (Option AMS) for InfiniiVision Series Oscilloscopes

RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes

Agilent Technologies N5454A Segmented Memory Acquisition for Agilent InfiniiVision Series Oscilloscopes

Keysight Technologies RS-232/UART Triggering and Hardware-Based Decode (N5457A) for InfiniiVision Oscilloscopes

FlexRay Measurements (Option FLX) for Agilent s InfiniiVision Series Oscilloscopes

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster

Memory-Depth Requirements for Serial Data Analysis in a Real-Time Oscilloscope

Keysight Technologies Segmented Memory Acquisition for InfiniiVision Series Oscilloscopes. Data Sheet

Keysight Technologies Using Oscilloscope Segmented Memory for Serial Bus Applications. Application Note

Agilent N5183A MXG Microwave Signal Generator

Time-Saving Features in Economy Oscilloscopes Streamline Test

Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details

Evaluating Oscilloscopes for Best Signal Visibility

Mixed Analog and Digital Signal Debug and Analysis Using a Mixed-Signal Oscilloscope Wireless LAN Example Application

Keysight Technologies FlexRay Measurements (Option FLX) for Keysight s InfiniiVision Series Oscilloscopes. Data Sheet

Agilent Understanding the Agilent 34405A DMM Operation Application Note

Keysight Technologies Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster. Application Note

Evaluating Oscilloscope Mask Testing for Six Sigma Quality Standards

Keysight Technologies Decoding Automotive Key Fob Communication based on Manchester-encoded ASK Modulation

Selecting the Right Oscilloscope for Protocol Analysis Applications

5 Series MSO Serial Triggering and Analysis Applications 5-SRAUDIO, 5-SRAUTO, 5-SRCOMP, and 5-SREMBD Datasheet Serial triggering

FlexRay Physical Layer Eye-diagram Mask Testing

Keysight Technologies Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details. Application Note

Agilent Migration from 8712/8714 Series to ENA-L Network Analyzers

Agilent N4876A 28 Gb/s Multiplexer 2:1

Evaluating Oscilloscope Vertical Noise Characteristics

Agilent I 2 C Debugging

Keysight Technologies Oscilloscope Memory Architectures Why All Acquisition Memory is Not Created Equal. Application Note

Low-speed serial buses are used in wide variety of electronics products. Various low-speed buses exist in different

Agilent ESA Series Spectrum Analyzers

Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope APPLICATION NOTE

Serial Triggering and Analysis Applications. Bus display. Bus decoding. Key features. Results table. Wave Inspector search

Troubleshooting Analog to Digital Converter Offset using a Mixed Signal Oscilloscope APPLICATION NOTE

Keysight Technologies Achieve High-Quality Compliance Test Results Using A Top-Quality Test Fixture. Application Note

Agilent CSA Spectrum Analyzer N1996A

Debugging a Mixed Signal Design with a Tektronix Mixed Signal Oscilloscope

Exceptional performance

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

Logic Analysis Fundamentals

Keysight Technologies Mixed Analog and Digital Signal Debug and Analysis Using a Mixed-Signal Oscilloscope

Agilent 87405C 100 MHz to 18 GHz Preamplifier

Quick Signal Integrity Troubleshooting with Integrated Logic Analyzers & Oscilloscopes

Agilent M9362A-D01-F26 PXIe Quad Downconverter

Analyzing 8b/10b Encoded Signals with a Real-time Oscilloscope Real-time triggering up to 6.25 Gb/s on 8b/10b encoded data streams

Debugging Embedded Mixed-Signal Designs Using Mixed Signal Oscilloscopes

Agilent Series Harmonic Mixers

Agilent 83000A Series Microwave System Amplifiers

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Serial Triggering and Analysis Application Modules

Debugging Digital Cameras: Detecting Redundant Pixels

Agilent InfiniiVision 7000 Series Oscilloscopes

A Simple, Yet Powerful Method to Characterize Differential Interconnects

Agilent MSO and CEBus PL Communications Testing Application Note 1352

Automated Limit Testing

Keysight Technologies Multi-Channel Audio Test using the Keysight U8903A Audio Analyzer

Agilent Series Preselected Millimeter Mixers

Agilent N4876A 28 Gb/s Multiplexer 2:1

Debugging Memory Interfaces using Visual Trigger on Tektronix Oscilloscopes

Keysight Technologies ad Integrated RF Test Solution

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

Agilent E6701G GSM/GPRS and E6704A EGPRS Lab Applications

Electrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV

Agilent InfiniiVision 7000B Series Oscilloscopes

Keysight Technologies Evaluating Oscilloscope Vertical Noise Characteristics. Application Note

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Evaluating Oscilloscopes to Debug Mixed-Signal Designs

Keysight Technologies N4974A PRBS Generator 44 Gb/s. Data Sheet

Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note

Tektronix Logic Analyzer Probes P6900 Series Datasheet for DDR Memory Applications

Scope of the art Scope Rider Handheld digital oscilloscope

Choosing an Oscilloscope

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Advanced Troubleshooting with Oscilloscopes 9000 Scope Hands-on Labs

Limit and Mask Test Application Module

Agilent 11713A Attenuator/Switch Driver

Meeting Embedded Design Challenges with Mixed Signal Oscilloscopes

C-PHY Essentials Transmitter Test Solution TekExpress C-PHY Essentials Tx

Viewing Serial Data on the Keysight Oscilloscopes

Memory Interface Electrical Verification and Debug

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors. Data Sheet

Oscilloscopes for debugging automotive Ethernet networks

Logic Analyzer Triggering Techniques to Capture Elusive Problems

Viewing Serial Data on the Keysight Oscilloscopes

Agilent E4887A HDMI TMDS Signal Generator Platform

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Full-featured CW Microwave Counters for Field, Factory or Lab

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Memory Interface Electrical Verification and Debug

Logic Analysis Basics

Logic Analysis Basics

Troubleshooting Your Design with Tektronix MSO and DPO Series Oscilloscopes

Keysight Technologies

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Debugging Embedded Mixed-Signal Designs Using Mixed Signal Oscilloscopes

Keysight Technologies ad Waveform Generation & Analysis Testbed, Reference Solution

Keysight N1085A PAM-4 Measurement Application For 86100D DCA-X Series Oscilloscopes. Data Sheet

Agilent Test Solutions for HDMI Thorough characterization and validation of HDMI-based designs

The use of Time Code within a Broadcast Facility

Keysight E4729A SystemVue Consulting Services

Transcription:

CAN/LIN Measurements (Option AMS) for Agilent s InfiniiVision Series Oscilloscopes Data Sheet Debug the signal integrity of your CAN and LIN designs faster Introduction The Agilent Technologies InfiniiVision Series digital storage oscilloscopes (DSOs) and mixed signal oscilloscopes (MSOs) offer integrated serial triggering and hardware-accelerated protocol decoding solutions that give you the tools you need to efficiently and effectively debug your embedded automotive or industrial equipment designs. Option AMS provides extended CAN and LIN triggering and decoding in all four-channel DSOs and MSOs. Features: Integrated serial triggering for testing your CAN and LIN serial buses Real-time protocol decode update rates using hardware-accelerated protocol decoding Precision differential active probes Mixed-signal measurements across analog sensors, serial buses, and digital ECU signals Compatible with Segmented Memory option to capture and decode up to 2000 consecutive frames

Enhance your ability to capture random and infrequent error conditions Other oscilloscope solutions with automotive serial bus triggering and protocol decode typically use software post-processing techniques to decode serial packets/frames. Using these software techniques, waveform- and decode-update rates tend to be slow (sometimes seconds per update), especially when you use deep memory, which is often required to capture multiple packetized serial signals in today s automotive applications. Agilent s automotive serial bus options are based on hardware technology to provide real-time protocol decode update rates. Hardware-accelerated decoding enhances your ability to capture random and infrequent error conditions so that you can debug your automotive designs faster. The Agilent CAN/LIN option on InfiniiVision Series scopes allows you to trigger on either standard or extended CAN message IDs, including the message ID of a remote transfer request frame. It supports triggering on a data frame, and allows you to specify message IDs, data and data length for filtering messages of interest. Triggering on active error frames are also supported. Decode information for the CAN and LIN buses is timecorrelated with each specific digitized packet waveform. To make the information easier to interpret, the decoded serial data is provided in a color-coded format, as shown in Figure 1. With the real-time update of decoded frames, your ability to find random and infrequent signal integrity problems is greatly enhanced. In this particular screen image, we can see that the scope captured and displayed an error frame (ERR) color-coded in red indicating an error caused by a system glitch coupling into the differential CAN signal. Bus quality and efficiency totalize function In addition to flagging CAN error frames in real-time, Option AMS also provides real-time CAN bus quality and efficiency measurements. The totalize function provides a complete count of all CAN frames, all active error frames (with %), all overload frames (with %), and a measure of bus utilization (in percent), sometimes called bus load, as shown in Figure 2. This unique totalize function, which is not available in other oscilloscopes currently on the market, is not related to the scope s acquisition or triggering. In addition, these CAN bus quality measurements are not affected by either the oscilloscope s acquisition window or scope dead-time. Totalize counts run continuously, even when the scope s acquisition is stopped. This provides an accurate measure of your CAN system s bus efficiency and quality. Figure 1. Random errors observed in CAN decode while triggering on data frame ID: 07F HEX Figure 2. Real-time totalize functions provide CAN bus efficiency and quality measurement statistics. 2

Segmented Memory captures more frames The Segmented Memory Option for Agilent s InfiniiVision series oscilloscopes can optimize your scope s acquisition memory allowing you to capture more CAN and/or LIN frames using less memory. Segmented memory acquisition optimizes the number of packetized serial communication frames that can be captured consecutively by selectively ignoring (not digitizing) unimportant idle time between frames. And with a minimum 250 picosecond time-tagging resolution, you will know the precise time between each frame. turned on, the scope easily captures 1000 consecutive CAN error frames for a total acquisition time of 127.3 seconds. After acquiring the 1000 segments/can error frames, we can easily scroll through all frames individually to look for physical layer issues that may be inducing these errors. Agilent s InfiniiVision series oscilloscopes are the only scopes on the market today that can not only acquire segments of up to four analog channels of acquisition, but also capture time-correlated segments on digital channels of acquisition (using an MSO model), along with hardwarebased serial bus protocol decoding. Figure 3 shows a CAN bus measurement with the scope setup to trigger on CAN error frames. Using this triggering condition with the segmented memory acquisition mode Figure 3. Capturing 1000 consecutive decoded CAN frames using segmented memory. 3

Probe automotive signals with precision even in environmental chambers Signal integrity measurements on CAN differential signals require differential active probing. Agilent offers a range of differential active probes for various bandwidths and dynamic range applications. For the most accurate measurements in automotive embedded systems, Agilent recommends the 1130 Series InfiniiMax active probes for either single-ended or differential applications. This family of active probes comes with a variety of interchangeable, passive probe heads for various probing use-models including browsing, solder-in, and socketed applications (see Figure 4). Automotive embedded designs must often be tested under simulated extreme conditions in environmental chambers. These extreme conditions may include testing ECUs and differential serial buses, such as CAN, at temperatures exceeding 150 degrees Celsius. Unfortunately, the active circuitry in today s typical active probes cannot tolerate temperatures exceeding 55 degrees C. However, with the unique electrical and physical architecture of the 1130 Series InfiniiMax active probes, the Extreme Temperature Cable Extension Kit (N5450A) can be used to extend and displace the probe s active amplifier to be outside of an environmental chamber (see Figure 6). With this configuration, InfiniiMax passive probe heads can be connected to test points within the chamber with temperatures ranging from 55 to +155 degrees C. Figure 4. Agilent 1130 Series differential active probes with interchangeable passive probe heads Figure 5. The Extreme Temperature Cable Extension Kit (N5450A) allows differential active probing within environmental chambers at extreme temperatures. When more robust probe point connections are required, the Agilent N2791A 25 MHz differential active probe may be a good low-cost solution for your probing applications (see Figure 5). Figure 6. Agilent N2791A 25 MHz differential active probe. Agilent also recommends the SI-200 differential active probe from Sapplive Instruments. For addition including a list of worldwide distributors, so to www.sapplive.com.tw Figure 7. Sapplive SI-200 differential active probe. 4

Easily make automotive mixed-signal measurements Today s automotive designs include a combination of analog, digital, and serial bus signals. The automotive embedded designer often needs to time-correlate signal activity across analog sensors, serial communication, and digital control and I/O signals within ECUs. Agilent InfiniiVision Series MSOs are the perfect fit for verifying and debugging these types of designs. Agilent MSOs that support automotive serial bus applications provide four channels of analog acquisition and up to sixteen channels of logic signal acquisition, as shown in Figure 8. Figure 8. Mixed-signal measurements in a mix-signal automotive system using an MSO Battery operation Evaluating CAN/LIN bus signal fidelity with an un-tethered oscilloscope requires a scope that performs CAN and LIN measurements under battery operation. Agilent InfiniiVision MSO6000 series oscilloscopes are the only battery-operated oscilloscopes on the market today that also support CAN and LIN, measurements. In addition to direct internal battery operation, the MSO6000 oscilloscopes can also be powered from an automobile s 12 V battery using an optional power adapter. Figure 9. Making remote CAN and LIN measurements with Agilent s battery option for InfiniiVision Series scopes. 5

CAN specifications/characteristics (N5424A or Option AMS) CAN source Analog channels 1, 2, 3, or 4 Baud rates 10 kbps up to 1 Mbps (user-selectable) Triggering Start-of-frame (SOF) 1 Remote frame ID (RMT) Data frame ID (~RMT) Remote or data frame ID Data frame ID and data Error frame ID length: 11 bits or 29 bits (extended) Color-coded, hardware-accelerated decode Totalize function Frame ID (hex digits in yellow) Remote frame (RMT in green) Data length code (DLC in blue) Data bytes (hex digits in white) CRC (hex digits in blue = valid, hex digits in red = error) Error frame (bi-level bus trace and ERR message in red) Overload frame ( OVRLD in blue) Idle bus (high bus trace in white) Active bus (bi-level bus trace in dark-blue) Total frames Total overload frames Total Error frames Bus utilization 1 Standard CAN triggering in all Agilent 6000 Series oscilloscopes LIN specifications/characteristics (N5424A or Option AMS) LIN source Analog channels 1, 2, 3, or 4 Logic channels D0 D15 LIN standards LIN 1.3 or LIN 2.0 Signal types Baud rates LIN single-ended Tx Rx 2400 bps, 9600 bps, 10.4 kbs, 19.2 kbs, 115.2 kbs or 625 kbs (user-selectable) Triggering Sync break 1 Frame ID (0X00 HEX to 0X3F HEX ) Frame ID AND Data Color-coded, hardware-accelerated decode Frame ID (6-bit hex digits in yellow) Frame ID and optional parity bits (8-bit hex digits in yellow) Data bytes (hex digits in white) Lin 2.0 check sum (hex digits in white) Lin 1.3 check sum (hex digits in blue = valid, hex digits in red = error) Sync error ( SYNC in red) T Header-Max ( THM in red) T Frame-max ( TFM in red) Parity error ( PAR in red) LIN 1.3 wake-up error ( WUP in red) Lin 1.3 idle bus (high bus trace in white) Active bus (bi-level bus trace in dark-blue) 1 Standard LIN triggering in all Agilent 6000 Series oscilloscopes 6

Ordering information Option AMS (CAN/LIN) is compatible only with 4-channel DSOs and 4+16 channel MSO models in the InfiniiVision Series oscilloscopes, including the 5000, 6000, and 7000 Series scopes. If you already own a 4-channel InfiniiVision Series DSO or MSO and would like to upgrade your scope to support CAN and LIN measurements, order the N5424A after-purchase upgrade kit. Factory-installed User-installed option number option number Description Option AMS N5424A CAN/LIN triggering and decode (4 and 4+16 channel models only) Option LSS N5423A I 2 C/SPI serial decode option (4 and 4+16 channel models only) Option 232 N5457A RS-232/UART triggering and decode (4 and 4+16 channel models only) Option SND N5468A I2S triggering and decode (4 and 4+16 channel models only) Option SGM N5454A Segmented Memory N2772A 1130A N5450A 20-MHz differential active probe InfiniiMax 1.5-GHz differential active probe (probe heads must be ordered separately) Extreme Temperature Cable Extension Kit for 1130A InfiniiMax probes Note that additional options and accessories are available for Agilent InfiniiVision Series oscilloscopes. Refer to the appropriate 5000, 6000, or 7000 Series data sheet for ordering information about these additional options and accessories, as well as ordering information for specific oscilloscope models. 7

Related literature Publication title Publication type Publication number Agilent Technologies Oscilloscope Family Brochure Brochure 5989-7650EN Agilent 7000 Series InfiniiVision Oscilloscopes Data sheet 5989-7736EN Agilent 6000 Series InfiniiVision Oscilloscopes Data sheet 5989-2000EN Agilent InfiniiVision Series Oscilloscope Probes and Accessories Data sheet 5968-8153EN I 2 C and SPI triggering and hardware-based decode options for Data sheet 5989-5126EN InfiniiVision Series Oscilloscopes (N5423A) RS-232/UART triggering and hardware-based decode for Data sheet 5989-7832EN InfiniiVision Series Oscilloscopes (N5457A) Segmented Memory Acquisition for Agilent InfiniiVision Data sheet 5989-7833EN Oscilloscopes (N5454A) Agilent N5450A InfiniiMax Extreme Temperature Extension Cable Kit Data sheet 5989-7542EN Using an Agilent InfiniiVision MSO to Debug an Automotive CAN Bus Application note 5989-5049EN Evaluating Oscilloscopes for Best Signal Visibility Application note 5989-7885EN Debugging Embedded Mixed-Signal Designs Using Application note 5989-3702EN Mixed Signal Oscilloscopes Choosing an Oscilloscope with the Right Bandwidth for your Applications Application note 5989-5733EN Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity Application note 5989-5732EN Evaluating Oscilloscope Vertical Noise Characteristics Application note 5989-3020EN The Extending the Range of Agilent InfiniiMax Probes Application note 5989-7587EN To download these documents, insert the publication number in the URL: http://cp.literature.agilent.com/litweb/pdf/xxxx-xxxxen.pdf Product Web site For the most up-to-date and complete application and product information, please visit our product Web site at: www.agilent.com/find/scopes 8

Agilent Technologies Oscilloscopes Multiple form factors from 20 MHz to > 90 GHz Industry leading specs Powerful applications 9

Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. For information regarding self maintenance of this product, please contact your Agilent office. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/fi nd/removealldoubt www.agilent.com www.agilent.com/find/can-lin For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894-4414 Latin America 305 269 7500 United States (800) 829-4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 01 36027 71571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700 Germany 07031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: October 1, 2008 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2009 Printed in USA, September 2, 2009 5989-6220EN